  • Hello! I am an AI chatbot trained to assist you with the Voyager ACRG12 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
14
DISPLAY CAU SE
SOLUTION
Er
E1
E2
E3
E4
E5
Lo
dF
Dip S witch position incorrect
Room Temp Sensor D efect
Indoor C oil Temp Sen sor D efect
Outdoor Coil Temp Sensor Defect
Outdoor Amb ient Temp Sensor Defect
Communication Defect w ith T-Stat and Relay K it
DC voltage is below 10 Volts (+/- 0 .5V)
Indoor o r Outdoor coil is frozen
Set D ip swithces to c orr ect p osition on back of T hermos tat
Replace The rmostat
Check wire connections and ensure s ensor is properly i nstall ed.
Replace Sen sor
Check wire connections and ensure s ensor is properly i nstall ed.
Replace Sen sor
Check wire connections and ensure s ensor is properly i nstall ed.
Replace Sen sor
Check wi re c onnections at T -Stat and r el ay k it
Check wi re c onnections an d ensure DC vo lt ag e is above 1 0 v olts
System i s d eicing a nd ca nn ot b e u sed f or 3 5 m inutes an d will restart