Aeg-Electrolux EFC9020-1X User manual

  • Hello! I am an AI chatbot trained to assist you with the Aeg-Electrolux EFC9020-1X User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
EFC 9020X
Air purification center
Wall-mounted
With cord suspension
Installation and operating instructions
Status 03/2008
1. Hood body 10. Power cord exit
2. Cable suspension 11. Heat detector
3. Cable retainer 12. Grease collecting pan
4. Cover disc 13. Halogen lamps 20 watt EKL
5. Hanger bolt 14. Disinfection lamp (UV-C lamp) EKL
6. Dowel 15. Stainless steel/carbon filter 586 x 324 mm
7. Metal filters with ionizer sheet 16. Starter for UV-C lamp
with spring locking 17. Main switch
8. Cable for ionizer sheet 18. Retainer for cable suspension
9. Wall fixing rail
Page 2
EFA 9020X air purification center (wall-mounted) with cord suspension
Installation instructions – operating instructions
In order to utilize your exhaust hood in the best possible way, please read these instructions carefully
and keep them for later when you might need them.
1. Safety and general information
This exhaust hood may only be connected to a grounded socket outlet installed according to
regulations, or directly by a professional electrician. Fuse grounded socket outlet preferably direct
in the connection box. Electrical data are found inside the apparatus on the type plate after
opening the grease collecting pan (12) behind the steel filter (15). Before opening, disconnect the
device form the mains power supply by turning off main switch (17).
Connection and putting in operation may only be carried out by a professional electrician.
Never operate exhaust hood without filters (7/15) and/or open grease collecting pan (12).
Always use gas cooking area appropriately.
The flames of gas burners must always be covered by cookware. Otherwise the exhaust hood
may become damaged due to the strong generation of heat from open gas flames.
Before commencing any cleaning or maintenance work, the power supply to the exhaust hood
must be interrupted by unplugging the connector from the socket or by switching off main switch
(17).
Do not prepare any flambéed dishes under the exhaust hood. The open flame could cause a fire.
Never leave the pan unattended when you deep-fry food because the grease could catch on fire.
Constant maintenance assures unobjectionable operation and maximum performance of your
exhaust hood.
All dirty surfaces should be regularly cleaned and cleared from deposits. The filter must frequently
be removed and cleaned.
Wrong halogen lamps (13) may destroy the transformer.
Do not cause the heat sensor to react by using a flame.
Between ceiling and top of the hood a minimum distance of 300 mm must be observed.
Minimum distance to the cooking range: with electric range: 700 mm, with gas stove: 700 mm.
This appliance must not be used by persons, also children, with diminished psychological,
sensoric, or mental abilities, or by persons without any experience and knowledge unless they are
supervised and instructed in the use of the appliance by a person being responsible for their
safety.
Children must never stay around unattended near the appliance and in no case play with this
device.
Safety shutdown:
If one or more filters are removed, the appliance switches off automatically. The appliance is not
ready for use again before the filters are in place correctly.
!!! Operate this appliance only with filters (7/15) inserted and grease collecting pan (12) closed !!!
!!! Before opening this device disconnect it from the mains power supply
by turning off main switch (17) !
Do not operate appliance without filters (7/15)
(High voltage and UV-C radiation)
Do not look into the lit up disinfection radiation source (14) !!!
Page 3
2. Before mounting and installation
The package contains the following parts: hood body including wall fixing rail, stainless steel
filters, by-pack kit, and cleaning set (the suspension cables are inside the by-pack kit)
Verify that the exhaust hood has not been damaged during transport. Should any damage exist,
the appliance must not be installed.
Ensure that installation and electrical connections are made by a qualified technician in
accordance with the manufacturer's specifications and official rules and regulations.
Make sure that a 3-wire mains cable or a socket outlet is available on site. The power cord exit
(10) is located on the top at the right rear corner inside the hood body.
Caution: The electrical connection must be made by a licensed electrician. The plug connector
must remain accessible after installation. A type 12 or type 13 socket outlet is to be provided. The
length of the connecting cable is ca. 2.4 m.
3. Mounting
Caution! The connection to the 230 volt mains as well as the entire installation of this exhaust hood
is unconditionally to be made at zero potential by a professional electrician.
1. Determine the height at which the appliance should be hung.
2. Draw an auxiliary line on the wall, which is to represent the bottom edge of the hood body.
3. Mark out the five drill points according to the hole pattern (Sketch 1) on the wall.
4. Now drill the five holes for the size 8 mm dowels.
5. Take the five size 8 mm dowels out of the by-pack kit and stick them into the drilled holes.
6. Take the wall fixing rail off from the rear side of the hood by unscrewing the three screws on the
topside of the hood.
7. Now fasten the wall fixing rail using five 5 x 50 mm round-head screws from the by-pack kit.
8. For the cable suspension you have to copy two drill holes onto the ceiling. See Sketch 2.
9. Now drill the two 10 mm holes into the ceiling.
10. Now take the two dowels and the two hanger bolts out of out of the by-pack kit and place them into
the two holes. Screw the two cover discs from the by-pack kit onto the hanger bolts.
11. Thread-in the cable suspension together with the cable tightener into the hood body from the top.
Screw in the cable tensioner into the retainer and lock it by tightening the headless screw. One
cable suspension per each retainer. (Figures 1 + 2).
12. Now hang in the hood body into the wall fixing rail.
13. Now screw the two cable suspensions together with the cable retainers onto the hanger bolts. In
doing so the steel cable may twist, however it will unstring again during workstep 15.
(Figure 3).
14. Now turn the three screws you had unscrewed before back into the hood body.
15. By exerting pressure on the cable tensioner the cable suspension is released and the length of the
steel cable can be varied. Using a water level the hood can be leveled out. (Figure 4).
16. Connect power cord of hood to supply line on site.
17. Cover up hood after mounting so that no dirt particles can fall on the top. Do not uncover the
device until the kitchen is completely erected and furnished and the final cleaning has been
done.
Page 4
Figure 1 Figure 2
Figure 3 Figure 4
Page 5
Sketch 1:
Hole pattern for
drill holes – wall
Sketch 2:
Holes – ceiling
for cable suspensions
4. Before putting in operation
Ensure that the device is disconnected from the mains power supply respectively that the main
switch is switched off.
Remove protective cardboard from UV-C lamp (14)
Insert the stainless steel filter 586 x 324 mm (15) into the hood body (1)
Close grease collecting pan (12)
Switch on main switch (17) on top of the device
(LED mains indicator is lit up green)
The appliance is now ready for operation!
UV-C lamp (14) with Main switch UV-C lamp (14) without
protective cardboard protective cardboard
Hood body (11) with
Stainless steel/ carbon filter (15)
5. Operation 7-rocker control
Page 6
Heat detector
(11)
Rocker 1 = To switch the right and the left halogen lamp on and off
Rocker 2 = To switch both halogen lamps in the front and both
halogen lamps in the beck on and off
Rocker 3-5 = To switch the different power levels
Power 1 = low step
Power 2 = medium step
Power 3 = high step
Pushbutton 6 = After-running 1 = 30 minutes
Pushbutton 7 = After-running 2 = 60 minutes
LED mains (green) = Device is ready for operation
LED fan (red) = Motor is running
LED (yellow) = Disinfection lamp and ionizer are in operation
(lit up all the time while the motor is running respectively
only when the motor is running)
Disinfection lamp (14) and ionizer start operating automatically when the motor is switched on. They
cannot and do not need to be switched on and off separately.
After running:
Please hold the after running rocker depressed for at least 2 seconds in order to be able to assure the
desired after running time.
6. Exchanging halogen reflector lamps (13)
Pull out defect halogen lamps (13) and press new lamps into the socket! Do not pry out defect halogen
lamps using metal parts (e.g. screwdriver or knife) since thereby the hood body could be damaged.
7. Taking out metal filters with Ionizer sheet (7)
Before taking out metal filters, it is imperative to disconnect the device form the mains power supply by
turning off main switch (17)!
When removing the upper filter (7) the following must be regarded:
To also enable cleaning of the ionizer sheet, it is necessary to detach the supply cable from each filter
when removing the filters. To do so just pull cable off (see photographs below).
Supply cable is detached from View after taking out
the ionizer sheet metal filter
Page 7
!! Please make sure that the snap locks are pointing towards the center of the hood when reinserting
!! Please make sure that the snap locks are pointing towards the center of the hood when reinserting!! Please make sure that the snap locks are pointing towards the center of the hood when reinserting
!! Please make sure that the snap locks are pointing towards the center of the hood when reinserting
metal filters
metal filters metal filters
metal filters !!
!!
!
8. Cleaning – care – filters
Cleaning the outside of the stainless steel exhaust hood:
A care lotion is enclosed with each device for cleaning and care. Moisten a soft cloth with care lotion
and apply it to the surface using slight pressure, let dry, and polish afterwards in brush direction. In
case of tenacious stains clean in brush direction using a special sponge (Scotch-Brite 374 green). Do
not rub by circular motions or crosswise to brush direction, since otherwise the surface is getting
scratched. After this treatment seal again with care lotion (as described above).
! On stainless steel devices, it is imperative to observe the "brush direction"!
Cleaning the inside:
Before opening it is imperative to disconnect the device form the mains power supply by
turning off main switch (17)!
When exchanging activated carbon fleece / activated carbon respectively when cleaning the metal
grease filters (7/15), clean accessible enclosure parts from grease deposits. This is to prevent a fire
hazard and optimum functioning is maintained. Please only clean using a grease-dissolving
dishwashing detergent or the grease remover included in the scope of delivery and a moist cloth.
Filters:
Caution! With increasing saturation by greasy deposits flammability increases and functioning of the
device may be impaired.
! Clean metal filters (7/15) in due time !
Before cleaning it is imperative to remove the activated carbon attachment and knurled screws!
At normal operating conditions (2 to 3 hours daily), the metal grease filter (7/15) needs to be cleaned
every 8 to 10 weeks. Cleaning should be done using the cleaning agent, which is attached to the
exhaust hood, however cleaning the filters can also be done in the dishwasher, depending on size.
The cleaning intervals for the metal filters (7) on top of the hood body shorten in the pollen-rich season.
The inner layers of the metal grease filters consist of aluminum. This is of great resistance against
chemical influences (corrosion resistance). However it is affected by sodium carbonate and caustic
soda so that after cleaning in the dishwasher, brownish discolorations could appear. The frame and the
cover sheet of those metal filters are made of stainless steel.
Do not clean metal grease filters (7/15) together with other dishes or cookware.
When cleaning by hand, flush through filters strongly several times in hot water with dishwashing
detergent.
Exchanging activated carbon
Before opening it is imperative to disconnect the device form the mains power supply by
turning off main switch (17)!
Activated carbon is applied for the absorption of odorous substances. The exchange of activated
carbon happens in intervals from 3 months to 1 year, depending on contamination.
Under any circumstances make device currentless by switching off main switch (17)!
Flap down grease collecting pan (12)
Remove stainless steel filter (15)
Loosen both knurled screws
Take off stainless steel frame and take out carbon cartridge
Page 8
At the carbon cartridge again loosen 2 knurled screws and change old carbon against new carbon
Retighten knurled screws loosened before
Insert stainless steel filter (15) into hood body
Stainless steel filter with activated
carbon cartridge (rear side)
9. What to do if …
Hood crackles:
Some sporadic crackling in the hood is normal. It indicates that air is cleaned by the ionizer. When
crackling continues persistently, the upper metal filters and the ionize sheet must be cleaned.
Furthermore you should check if the connector of the supply cable is connected to the ionizer sheet
horizontally.
In case of undervoltage it can happen in power step 1 that the interconnecting relay for the ionizer and
for the UVC lamp switches on and off several times (flips). You can eliminate this by shortly activating
power step 3.
Hood cannot be switched on:
Check if all filters are inserted correctly, since each filter is provided with a microswitch, which interrupt
the circuit in the hood if any of the filters is not correctly in place.
Page 9
Carbon cartridge
detachable
Stainless steel
filter
Opening for emptying
loose activated carbon
10. Service
The well-extended Electrolux customer service is available to all our customers.
Before you call customer service:
Assure yourself that no operating error exists.
Check your exhaust hood following the chapter "What to do if …… "
If you engage customer service:
Note down the following information, which you'll find on the type plate of your device:
Serial number
Model identification
Product number
Please always quote these data in case of:
Calling customer service
Ordering spare parts or accessories
Technical queries
The type plate is located inside the hood body behind the filter.
Note down your observations precisely. This facilitates preparation and the work for our service
technician.
Call the service number at 0848 848 111. Your call will automatically be routed to your closest
service location.
Please be at home when the service technician comes, since he is dependent on your
information.
11. Spare parts – accessories:
Activated carbon refill pack 1 kg, A.-No. 407 14 38-29 / 7
Filter cleaning agent "Flamil 50 Super" 200 ml, A.-No. 407 14 38-30 / 5
Stainless steel cleaner 200 ml, A.-No. 407 14 38-31 / 3
12. Quality control
These devices are subjected to the following tests according to VDE 0701, part 1, and according to
EN60335-1:
Protective ground wire test
High voltage test
Insulation test
Functional and performance test
Mechanical visual inspection
An additional visual inspection is made and the completeness of accessories is verified.
This product has been designed, built, and put on the market in compliance with:
The safety objective of directive "Low Voltage" EG/73/23
The protection requirements of directive "EMC" EG/336/89, amended by directive EG/68/93.
Page 10
13. Warranty / customer service
Page 13
14. Information
Information regarding the heat detector (11):
We care about your safety. For that reason we have installed a thermo sensor (11) at this air
purification center that functions as follows.
If directly under the exhaust hood a temperature between 69 °C and 71 °C is reached, a siren sounds
automatically and the power supply to the device is interrupted. After cooling down to ca. 30 °C – 35 °C
the siren automatically goes of again.
Information regarding the ionizer:
The ionizer freshens the air. The negative ions clean the air from very fine dust particles, from bacteria
floating in the air on positive ions, from floating viruses and fungal spores. Through the airflow caused
by the built-in motor, particles are carried to a metal filter where they deposit. Those deposits are
removed by cleaning the upper metal filters (3) on a regular basis.
Using the ionizer is not hazardous! Even from high dose of negative ions doesn't do you any harm. A
high dose of positive ions however can make you sick, tired, slackly, sometimes even irritated and
aggressive.
Information regarding the disinfection radiator (14):
This disinfection radiator is a special low-pressure mercury vapor radiator emitting short-wave ultra
violet radiation whereas the disinfecting effect of which is by far superior to the one of natural solar
irradiation. It destroys effectively all microorganisms such as bacteria, viruses, spores, yeasts, algae,
protozoa, and mold fungi – and all that without ozone!
!! Since UV-C radiation is hazardous to the eye, never look directly into the turned on lamp !!
WARNING:
Touching the lamp with bare hands causes spots. Always use a clean cloth or wear clean gloves!
If quartz glass was touched by hands, it must be cleaned first using little alcohol before putting it in
operation.
Page 14
15. Note regarding correct disposal of the product
DISPOSAL
Packing material
The packing materials are environmental compatible and recyclable. Plastic parts are
marked, e.g. >PE<, >PS<, etc. Dispose of packing materials according to their respective
markings at municipal waste management locations into the collection dumpsters provided
for those materials.
Old appliance
This symbol on the product or on the packing indicates that this product must not be
treated as regular household garbage, but instead has to be delivered up at a collection
point for the recycling of electrical and electronic equipment. With your contribution to the
correct disposal of this product you protect the environment and your fellow human beings'
health. Environment and health are being jeopardized by incorrect disposal. Additional
information about the recycling of this product you will get at your city hall, your garbage
collection office, or at the shop where you had bought this product.
Where to dispose of the old appliances?
Everywhere where new appliances are sold, or delivering up at the official S.EN.S
collection points, or at official S.EN.S recycling firms.
A list of official S.EN.S recycling firms you will find at www.sens.ch.
Warning: To ensure that no hazard can arise from the worn out appliance anymore, render
it unusable before disposing of. To do so disconnect the device from the mains power
supply and remove the mains connection cable from it.
16. Technical data
External dimension: 900 x 600 mm
Minimum distance to cooking range: 700 mm
Supply voltage: 230 volt
Power consumption: 272 watt
Total weight: 29 kg
Page 13
/