1. Select the installation location according to the require-
ment of this manual.(See the requirements in installation
part)
2. Handle unit transportation with care; the unit should not
be carried by only one person if it is more than 20kg.
:KHQLQVWDOOLQJWKHLQGRRUXQLWDQGRXWGRRUXQLWDVXI¿-
FLHQW¿[LQJEROWPXVWEHLQVWDOOHGPDNHVXUHWKHLQVWDOODWLRQ
VXSSRUWLV¿UP
4. Ware safety belt if the height of working is above 2m.
5. Use equipped components or appointed components dur-
ing installation.
0DNHVXUHQRIRUHLJQREMHFWV DUHOHIWLQ WKHXQLWDIWHU ¿Q-
ishing installation.
Electrical Safety Precautions:
7. Notes for Installation and Maintenance
Safety Precautions:
Important!
Please read the safety precautions carefully before
installation and maintenance.
The following contents are very important for installation
and maintenance.
Please follow the instructions below.
Ɣ7KHLQVWDOODWLRQRUPDLQWHQDQFHPXVWDFFRUGZLWKWKH
instructions.
Ɣ&RPSO\ZLWKDOOQDWLRQDOHOHFWULFDOFRGHVDQGORFDO
electrical codes.
Ɣ3D\DWWHQWLRQWRWKHZDUQLQJVDQGFDXWLRQVLQWKLV
manual.
Ɣ$OOLQVWDOODWLRQDQGPDLQWHQDQFHVKDOOEHSHUIRUPHGE\
GLVWULEXWRURUTXDOL¿HGSHUVRQ
Ɣ$OOHOHFWULFZRUNPXVWEHSHUIRUPHGE\DOLFHQVHG
technician according to local regulations and the
instructions given in this manual.
Ɣ%HFDXWLRQGXULQJLQVWDOODWLRQDQGPDLQWHQDQFH3URKLELW
incorrect operation to prevent electric shock, casualty and
other accidents.
1. Cut off the power supply of air conditioner before
checking and maintenance.
2. The air condition must apply specialized circuit and
prohibit share the same circuit with other appliances.
3. The air conditioner should be installed in suitable
location and ensure the power plug is touchable.
4. Make sure each wiring terminal is connected firmly
during installation and maintenance.
5. Have the unit adequately grounded. The grounding
wire can’t be used for other purposes.
6. Must apply protective accessories such as protective
boards, cable-cross loop and wire clip.
7. The live wire, neutral wire and grounding wire of
power supply must be corresponding to the live wire,
neutral wire and grounding wire of the air conditioner.
8. The power cord and power connection wires can’t be
pressed by hard objects.
9. If power cord or connection wire is broken, it must be
UHSODFHGE\DTXDOL¿HGSHUVRQ
$YRLGFRQWDFWEHWZHHQUHIULJHUDQWDQG¿UHDVLWJHQHUDWHV
poisonous gas; Prohibit prolong the connection pipe by
welding.
$SSO\VSHFL¿HGUHIULJHUDQWRQO\ 1HYHUKDYHLWPL[HGZLWK
any other refrigerant. Never have air remain in the refrigerant
line as it may lead to rupture or other hazards.
3. Make sure no refrigerant gas is leaking out when
installation is completed.
4. If there is refrigerant leakage, please take sufficient
measure to minimize the density of refrigerant.
5. Never touch the refrigerant piping or compressor without
wearing glove to avoid scald or frostbite.
Warnings
Refrigerant Safety Precautions:
,PSURSHULQVWDOODWLRQPD\OHDGWR¿UHKD]DUGH[SORVLRQ
electric shock or injury.
Installation Safety Precautions:
Part
ė
: Installation and Maintenance
10. If the power cord or connection wire is not long enough,
please get the specialized power cord or connection wire
from the manufacture or distributor. Prohibit prolong the wire
by yourself.
11. For the air conditioner without plug, an air switch must
be installed in the circuit. The air switch should be all-pole
parting and the contact parting distance should be more than
3mm.
12. Make sure all wires and pipes are connected properly and
the valves are opened before energizing.
13. Check if there is electric leakage on the unit body. If yes,
please eliminate the electric leakage.
5HSODFHWKHIXVHZLWKDQHZRQHRIWKHVDPHVSHFL¿FDWLRQ
if it is burnt down; don’t replace it with a cooper wire or
conducting wire.
15. If the unit is to be installed in a humid place, the circuit
breaker must be installed.
42
Installation and Maintenance
Service Manual
Main Tools for Installation and Maintenance
1. Level meter, measuring tape
4. Electroprobe
7. Electronic leakage detector
10. Pipe pliers, pipe cutter
2. Screw driver
5. Universal meter
8. Vacuum pump
11. Pipe expander, pipe bender
3. Impact drill, drill head, electric drill
6. Torque wrench, open-end wrench, inner
hexagon spanner
9. Pressure meter
12. Soldering appliance, refrigerant container
43
Installation and Maintenance
Service Manual
8. Installation
8.1 Installation Dimension Diagram
Space to the obstruction
Drainage pipe
Space to the wall
Space to the obstruction
Space to the obstruction
Space to the obstruction
At least 50cm
At least 200cm
At least 30cm
At least 30cm
At least 50cm
Space to the ceiling
Space to the wall
At least 15cm
At least 15cm
At least 15cm
At least 250cm
Space to the wall
Space to the obstruction
roolfehtotecapS
At least 300cm
44
Installation and Maintenance
Service Manual
Preparation before installation
Prepare tools
Read the requirements
for electric connection
select installation
location
Select indoor unit
installation location
Install wall-mounting
frame, drill wall holes
Connect pipes of indoor
unit and drainage pipe
Connect wires of indoor unit
Connect wires of outdoor unit
Bind up pipes and
hang the indoor unit
Make the bound pipes pass
through the wall hole and then
connect outdoor unit
Neaten the pipes
Vacuum pumping and leakage detection
Check after installation and test operation
Finish installation
Note: this flow is only for reference; please find the more detailed installation steps in this section.
Select outdoor unit
installation location
Install the support of outdoor unit
(select it according to the actual situation)
Install drainage joint of outdoor unit
(only for cooling and heating unit)
Connect pipes of outdoor unit
Start installation
Fix outdoor unit
Installation Procedures
45
Installation and Maintenance
Service Manual
No. Name No. Name
1 ,QGRRUXQLW 8 6HDOLQJJXP
2 2XWGRRUXQLW 9 Wrapping tape
3 Connection pipe 10
6XSSRUWRIRXWGRRU
XQLW
4 Drainage pipe 11 )L[LQJVFUHZ
5
:DOOPRXQWLQJ
frame
12
'UDLQDJHSOXJFRROLQJ
DQGKHDWLQJXQLW
6
Connecting
cable(power cord)
13
2ZQHUVPDQXDO
remote controller
7 Wall pipe
1. Safety Precaution
0XVWIROORZWKHHOHFWULFVDIHW\UHJXODWLRQVZKHQLQVWDOOLQJ
WKHXQLW
$FFRUGLQJWRWKHORFDOVDIHW\UHJXODWLRQVXVHTXDOLILHG
SRZHUVXSSO\FLUFXLWDQGDLUVZLWFK
0DNHVXUHWKHSRZHUVXSSO\PDWFKHVZLWKWKHUHTXLUHPHQW
RIDLUFRQGLWLRQHU8QVWDEOHSRZHUVXSSO\RULQFRUUHFWZLULQJ
PD\UHVXOWLQHOHFWULFVKRFN¿UHKD]DUGRUPDOIXQFWLRQ3OHDVH
LQVWDOOSURSHUSRZHUVXSSO\FDEOHVEHIRUHXVLQJWKHDLU
conditioner.
3URSHUO\FRQQHFWWKHOLYHZLUHQHXWUDOZLUHDQGJURXQGLQJ
ZLUHRISRZHUVRFNHW
%HVXUHWRFXWRIIWKHSRZHUVXSSO\EHIRUHSURFHHGLQJDQ\
ZRUNUHODWHGWRHOHFWULFLW\DQGVDIHW\
'RQRWSXWWKURXJKWKHSRZHUEHIRUH¿QLVKLQJLQVWDOODWLRQ
)RUDSSOLDQFHVZLWKW\SH<DWWDFKPHQWWKHLQVWUXFWLRQV
VKDOOFRQWDLQWKHVXEVWDQFHRIWKHIROORZLQJ,IWKHVXSSO\FRUGLV
GDPDJHGLWPXVWEHUHSODFHGE\WKHPDQXIDFWXUHULWVVHUYLFH
DJHQWRUVLPLODUO\TXDOL¿HGSHUVRQVLQRUGHUWRDYRLGDKD]DUG
7KHWHPSHUDWXUH RIUHIULJHUDQWFLUFXLWZLOOEHKLJKSOHDVH
NHHSWKHLQWHUFRQQHFWLRQFDEOHDZD\IURPWKHFRSSHUWXEH
8.2 Installation Parts-Checking
8.3 Selection of Installation Location
8.4 Electric Connection Requirement
8.5 Installation of Indoor Unit
Air-conditioner $LUVZLWFKFDSDFLW\
28K 25A
18/24K 16A
3OHDVHFRQWDFWWKHORFDODJHQWIRULQVWDOODWLRQ
'RQWXVHXQTXDOL¿HGSRZHUFRUG
1. Basic Requirement:
,QVWDOOLQJWKHXQLWLQWKHIROORZLQJSODFHVPD\FDXVH
PDOIXQFWLRQ,ILWLVXQDYRLGDEOHSOHDVHFRQVXOWWKHORFDOGHDOHU
7KHSODFHZLWKVWURQJKHDWVRXUFHVYDSRUVÀDPPDEOHRU
H[SORVLYHJDVRUYRODWLOHREMHFWVVSUHDGLQWKHDLU
7KHSODFH ZLWKKLJKIUHTXHQF\GHYLFHVVXFKDVZHOGLQJ
PDFKLQHPHGLFDOHTXLSPHQW
7KHSODFHQHDUFRDVWDUHD
7KHSODFHZLWKRLORUIXPHVLQWKHDLU
7KHSODFHZLWKVXOIXUHWHGJDV
2WKHUSODFHVZLWKVSHFLDOFLUFXPVWDQFHV
2. Grounding Requirement:
7KHDLUFRQGLWLRQHULV¿UVWFODVVHOHFWULFDSSOLDQFH,WPXVW
EHSURSHUO\JURXQGLQJZLWKVSHFLDOL]HGJURXQGLQJGHYLFH
E\DSURIHVVLRQDO3OHDVHPDNHVXUHLWLVDOZD\VJURXQGHG
HIIHFWLYHO\RWKHUZLVHLWPD\FDXVHHOHFWULFVKRFN
7KH\HOORZJUHHQZLUHLQDLUFRQGLWLRQHULVJURXQGLQJZLUH
ZKLFKFDQWEHXVHGIRURWKHUSXUSRVHV
7KHJURXQGLQJUHVLVWDQFHVKRXOGFRPSO\ZLWKQDWLRQDO
HOHFWULFVDIHW\UHJXODWLRQV
7KHDSSOLDQFHPXVWEHSRVLWLRQHGVRWKDWWKHSOXJLV
accessible.
$QDOOSROHGLVFRQQHFWLRQVZLWFKKDYLQJDFRQWDFWVHSDUDWLRQ
RIDWOHDVWPPLQDOOSROHVVKRXOGEHFRQQHFWHGLQ¿[HGZLULQJ
,QFOXGLQJDQDLUVZLWFKZLWKVXLWDEOHFDSDFLW\SOHDVHQRWH
WKHIROORZLQJWDEOH$LUVZLWFKVKRXOGEHLQFOXGHGPDJQHW
EXFNOHDQGKHDWLQJEXFNOHIXQFWLRQLWFDQSURWHFWWKHFLUFXLW
VKRUWDQGRYHUORDG&DXWLRQSOHDVHGRQRWXVHWKHIXVHRQO\
IRUSURWHFWWKHFLUFXLW
1. Choosing Installation Iocation
5HFRPPHQGWKHLQVWDOODWLRQORFDWLRQWR WKHFOLHQWDQGWKHQ
FRQ¿UPLWZLWKWKHFOLHQW
2. Install Wall-mounting Frame
+DQJWKHZDOOPRXQWLQJIUDPHRQWKHZDOODGMXVWLWLQ
KRUL]RQWDOSRVLWLRQZLWKWKHOHYHOPHWHUDQGWKHQSRLQWRXWWKH
VFUHZ¿[LQJKROHVRQWKHZDOO
'ULOOWKHVFUHZ¿[LQJKROHVRQWKHZDOOZLWKLPSDFWGULOOWKH
VSHFLILFDWLRQRIGULOOKHDGVKRXOGEHWKHVDPHDVWKHSODVWLF
H[SDQVLRQSDUWLFOHDQGWKHQ¿OOWKHSODVWLFH[SDQVLRQSDUWLFOHV
2. Indoor Unit:
7KHUHVKRXOGEHQRREVWUXFWLRQQHDUDLULQOHWDQGDLURXWOHW
6HOHFWDORFDWLRQZKHUH WKHFRQGHQVDWLRQZDWHUFDQEH
GLVSHUVHGHDVLO\DQGZRQWDIIHFWRWKHUSHRSOH
6HOHFWDORFDWLRQZKLFKLVFRQYHQLHQWWRFRQQHFWWKH
RXWGRRUXQLWDQGQHDUWKHSRZHUVRFNHW
6HOHFWDORFDWLRQZKLFKLVRXWRIUHDFKIRUFKLOGUHQ
7KHORFDWLRQVKRXOGEHDEOHWRZLWKVWDQGWKHZHLJKWRI
LQGRRUXQLWDQGZRQWLQFUHDVHQRLVHDQGYLEUDWLRQ
7KHDSSOLDQFHPXVWEHLQVWDOOHGPDERYHÀRRU
'RQWLQVWDOOWKHLQGRRUXQLWULJKWDERYHWKHHOHFWULF
appliance.
7KHDSSOLDQFHVKDOOQRWEHLQVWDOOHGLQWKHODXQGU\
3. Outdoor Unit:
6HOHFWDORFDWLRQZKHUHWKHQRLVHDQGRXWÀRZDLUHPLWWHGE\
WKHRXWGRRUXQLWZLOOQRWDIIHFWQHLJKERUKRRG
7KHORFDWLRQVKRXOGEHZHOOYHQWLODWHGDQGGU\LQZKLFKWKH
RXWGRRUXQLWZRQWEHH[SRVHGGLUHFWO\WRVXQOLJKWRUVWURQJ
wind.
7KHORFDWLRQVKRXOGEHDEOHWRZLWKVWDQGWKHZHLJKWRI
RXWGRRUXQLW
0DNHVXUHWKDWWKHLQVWDOODWLRQIROORZVWKHUHTXLUHPHQWRI
installation dimension diagram.
6HOHFWDORFDWLRQZKLFKLVRXWRIUHDFKIRUFKLOGUHQDQGIDU
DZD\IURPDQLPDOVRUSODQWV,ILWLVXQDYRLGDEOHSOHDVHDGG
IHQFHIRUVDIHW\SXUSRVH
Note:
46
Installation and Maintenance
Service Manual
Outlet
pipe
Drain hose
Drain hose
Ta
p
e
Outlet pipe
Insulating pipe
Torque wrench
Open-end
wrench
Indoor pipe
Pipe
Union nut
Union nutPipe joint
Pipe
+H[QXWGLDPHWHUPP 7LJKWHQLQJWRUTXH1P
ĭ 15~20
ĭ 30~40
ĭ 45~55
ĭ 60~65
ĭ 70~75
5HIHUWRWKHIROORZLQJWDEOHIRUZUHQFKPRPHQWRIIRUFH
:
Left
Rear left
Right
Rear right
Cut off
the hole
Left Right
Drain hose
Insulating pipe
5-10
°
Φ55/Φ70mm
Indoor
Outdoor
3D\DWWHQWLRQWRGXVW SUHYHQWLRQDQGWDNHUHOHYDQWVDIHW\
PHDVXUHVZKHQRSHQLQJWKHKROH
7KHSODVWLFH[SDQVLRQSDUWLFOHVDUHQRWSURYLGHGDQGVKRXOG
EHERXJKWORFDOO\
$GGLQVXODWLQJSLSHLQWKHLQGRRUGUDLQKRVHLQRUGHUWR
SUHYHQWFRQGHQVDWLRQ
7KHSODVWLF H[SDQVLRQSDUWLFOHVDUHQRW SURYLGHG$VVKRZ
LQ)LJ
)LJ
)LJ
)LJ )LJ
)LJ
)LJ
)LJ
)LJ
)LJ
)LJ
LQWKHKROHV
)L[WKHZDOOPRXQWLQJIUDPHRQWKHZDOOZLWKWDSSLQJVFUHZV
67;7$DQGWKHQFKHFNLIWKHIUDPHLV¿UPO\LQVWDOOHGE\
SXOOLQJWKHIUDPH,IWKH SODVWLFH[SDQVLRQSDUWLFOHLVORRVH
SOHDVHGULOODQRWKHU¿[LQJKROHQHDUE\
3. Install Wall-mounting Frame
&KRRVHWKHSRVLWLRQRISLSLQJKROHDFFRUGLQJWRWKHGLUHFWLRQ
RIRXWOHWSLSH7KHSRVLWLRQRISLSLQJKROHVKRXOGEHDOLWWOH
ORZHUWKDQWKHZDOOPRXQWHGIUDPH$VVKRZLQ)LJ
5. Connect the Pipe of Indoor Unit
$LPWKHSLSHMRLQWDWWKHFRUUHVSRQGLQJEHOOPRXWK$VVKRZ
LQ)LJ
3UHWLJKWHQLQJWKHXQLRQQXWZLWKKDQG
$GMXVWWKHWRUTXHIRUFHE\UHIHUULQJWRWKHIROORZLQJVKHHW
3ODFHWKHRSHQHQGZUHQFKRQWKHSLSHMRLQWDQGSODFHWKH
WRUTXHZUHQFKRQWKHXQLRQQXW7LJKWHQWKHXQLRQQXWZLWK
WRUTXHZUHQFK$VVKRZLQ)LJ
:UDSWKH LQGRRUSLSHDQGMRLQW RIFRQQHFWLRQSLSHZLWK
LQVXODWLQJSLSHDQGWKHQZUDSLWZLWKWDSH$VVKRZLQ)LJ
6. Install Drain Hose
&RQQHFWWKHGUDLQKRVHWRWKHRXWOHWSLSHRILQGRRUXQLW$V
VKRZLQ)LJ
%LQGWKHMRLQWZLWKWDSH$VVKRZLQ)LJ
4. Outlet Pipe
7KHSLSHFDQEHOHGRXWLQWKHGLUHFWLRQRIULJKWUHDUULJKW
OHIWRUUHDUOHIW$VVKRZLQ)LJ
:KHQVHOHFWLQJOHDGLQJRXWWKHSLSHIURPOHIWRUULJKWSOHDVH
FXWRIIWKHFRUUHVSRQGLQJKROHRQWKHERWWRPFDVH$VVKRZLQ
)LJ
2SHQDSLSLQJKROHZLWKWKHGLDPHWHURIĭPPRQWKH
VHOHFWHGRXWOHWSLSHSRVLWLRQ,QRUGHUWRGUDLQVPRRWKO\VODQW
WKHSLSLQJKROHRQWKHZDOOVOLJKWO\GRZQZDUGWRWKHRXWGRRU
VLGHZLWKWKHJUDGLHQWRI$VVKRZLQ)LJ
Note:
Note:
Left
Wall
Φ55/70mm
Φ55/70mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Rear piping hole
.
47
Installation and Maintenance
Service Manual
Wire clip
Wiring board
blue black brown yellow-
green
Connect to outdoor unit
2
N
(
1
)
3
2
3
3XWZLULQJFRYHUEDFNDQGWKHQWLJKWHQWKHVFUHZ
&ORVHWKHSDQHO
Indoor unit
Gas
pipe
Indoor and
outdoor power cord
Liquid
pipe
Drain hose
Band
Drain hose
Band
Connection pipe
Indoor power cord
Wiring cover
Screw
Panel
$OOZLUHVRILQGRRUXQLWDQGRXWGRRUXQLWVKRXOGEH
connected by a professional.
,IWKHOHQJWKRISRZHUFRQQHFWLRQZLUHLVLQVXI¿FLHQWSOHDVH
FRQWDFWWKHVXSSOLHUIRUDQHZRQH$YRLGH[WHQGLQJWKHZLUHE\
\RXUVHOI
)RUWKHDLUFRQGLWLRQHUZLWKSOXJWKHSOXJVKRXOGEH
UHDFKDEOHDIWHU¿QLVKLQJLQVWDOODWLRQ
)RUWKHDLUFRQGLWLRQHUZLWKRXWSOXJDQDLUVZLWFKPXVWEH
LQVWDOOHGLQWKHOLQH7KHDLUVZLWFKVKRXOG EHDOOSROHSDUWLQJ
DQGWKHFRQWDFWSDUWLQJGLVWDQFHVKRXOGEHPRUHWKDQPP
7KHSRZHU FRUGDQGFRQWUROZLUH FDQWEHFURVVHGRU
winding.
7KHGUDLQKRVHVKRXOGEHERXQGDWWKHERWWRP
'RQRWEHQGWKHGUDLQKRVHWRRH[FHVVLYHO\LQRUGHUWRSUHYHQW
EORFNLQJ
7. Connect Wire of Indoor Unit
2SHQWKHSDQHOUHPRYHWKHVFUHZRQWKHZLULQJFRYHUDQG
WKHQWDNHGRZQWKHFRYHU$VVKRZLQ)LJ
8. Bind up Pipe
%LQGXSWKHFRQQHFWLRQ SLSHSRZHUFRUGDQGGUDLQKRVH
ZLWKWKHEDQG$VVKRZLQ)LJ
5HVHUYHDFHUWDLQOHQJWKRIGUDLQKRVHDQGSRZHUFRUG
IRULQVWDOODWLRQZKHQELQGLQJWKHP:KHQELQGLQJWRDFHUWDLQ
GHJUHHVHSDUDWHWKHLQGRRUSRZHUDQGWKHQVHSDUDWHWKHGUDLQ
KRVH$VVKRZLQ)LJ
%LQGWKHPHYHQO\
7KHOLTXLGSLSHDQGJDVSLSHVKRXOGEHERXQGVHSDUDWHO\DW
WKHHQG
9. Hang the Indoor Unit
3XWWKHERXQGSLSHVLQWKHZDOOSLSHDQGWKHQPDNHWKHP
SDVVWKURXJKWKHZDOOKROH
+DQJWKHLQGRRUXQLWRQWKHZDOOPRXQWLQJIUDPH
6WXIIWKHJDSEHWZHHQSLSHVDQGZDOOKROHZLWKVHDOLQJJXP
)L[WKHZDOOSLSH$VVKRZLQ)LJ
&KHFNLIWKHLQGRRUXQLWLVLQVWDOOHG¿UPO\DQGFORVHGWRWKH
ZDOO$VVKRZLQ)LJ
5HPRYHWKHZLUHFOLSFRQQHFWWKHSRZHUFRQQHFWLRQZLUH
WRWKHZLULQJWHUPLQDODFFRUGLQJWRWKHFRORUWLJKWHQWKHVFUHZ
DQGWKHQ¿[WKHSRZHUFRQQHFWLRQZLUHZLWKZLUHFOLS$VVKRZ
LQ)LJ
Note:
Note:
Note:
Indoor
Outdoor
Wall pipe
Sealing gum
Upper hook
Lower hook of
wall-mounting frame
)LJ
)LJ
)LJ
)LJ
)LJ
)LJ
Power connection
wire
Cable-cross
hole
(2) Make the power connection wire go through the cable-cross
hole at the back of indoor unit and then pull it out from the front
side.(As show in Fig.12)
48
Installation and Maintenance
Service Manual
7DNHVXIILFLHQWSURWHFWLYHPHDVXUHVZKHQLQVWDOOLQJWKH
RXWGRRUXQLW
0DNHVXUHWKHVXSSRUWFDQZLWKVWDQGDWOHDVWIRXUWLPHVWKH
XQLWZHLJKW
7KHRXWGRRUXQLWVKRXOGEHLQVWDOOHGDWOHDVWFPDERYHWKH
ÀRRULQRUGHUWRLQVWDOOGUDLQMRLQW$VVKRZLQ)LJ
)RUWKHXQLWZLWKFRROLQJFDSDFLW\RI:a:
H[SDQVLRQVFUHZVDUHQHHGHGIRUWKHXQLWZLWKFRROLQJFDSDFLW\
RI:a:H[SDQVLRQVFUHZVDUHQHHGHGIRUWKH
XQLWZLWKFRROLQJFDSDFLW\RI:a:H[SDQVLRQ
screws are needed.
$IWHUWLJKWHQLQJWKH VFUHZSXOOWKHSRZHUFRUGVOLJKWO\WR
FKHFNLILWLV¿UP
1HYHUFXWWKHSRZHUFRQQHFWLRQZLUHWRSURORQJRUVKRUWHQ
WKHGLVWDQFH
7KHWKURXJKZDOOKHLJKWRIGUDLQKRVHVKRXOGQWEHKLJKHU
WKDQWKHRXWOHWSLSHKROHRILQGRRUXQLW$VVKRZLQ)LJ
6ODQWWKHGUDLQKRVHVOLJKWO\GRZQZDUGV7KHGUDLQKRVH
FDQWEHFXUYHGUDLVHGDQGÀXFWXDQWHWF$VVKRZLQ)LJ
Note:
Note:
Note:
The drain hos
can't raise
upwards
gas pipe
Liquid pipe
Liquid
valve
gas valve
Union nut
Pipe joint
Foot holes
Foot holes
Chassis
Outdoor drain joint
Drain hose
Drain vent
8.6 Installation of Outdoor Unit
1. Fix the Support of Outdoor Unit(select it according to the
actual installation situation)
6HOHFWLQVWDOODWLRQORFDWLRQDFFRUGLQJWRWKHKRXVHVWUXFWXUH
)L[WKHVXSSRUWRIRXWGRRUXQLWRQWKHVHOHFWHGORFDWLRQZLWK
expansion screws.
5. Connect Outdoor Electric Wire
5HPRYHWKHZLUHFOLSFRQQHFWWKHSRZHUFRQQHFWLRQZLUH
DQGSRZHUFRUGWRWKHZLULQJWHUPLQDODFFRUGLQJWRWKHFRORU¿[
WKHPZLWKVFUHZV$VVKRZLQ)LJ
6. Neaten the Pipes
7KHSLSHVVKRXOGEHSODFHGDORQJWKHZDOOEHQWUHDVRQDEO\
DQGKLGGHQSRVVLEO\0LQVHPLGLDPHWHURIEHQGLQJWKHSLSHLV
10cm.
,IWKHRXWGRRUXQLWLVKLJKHUWKDQWKHZDOOKROH\RXPXVWVHW
D8VKDSHGFXUYHLQWKHSLSHEHIRUHSLSHJRHVLQWRWKHURRP
LQRUGHUWRSUHYHQWUDLQ IURPJHWWLQJLQWRWKHURRP$VVKRZLQ
)LJ
)L[WKHSRZHUFRQQHFWLRQZLUHDQGSRZHUFRUGZLWKZLUHFOLS
2. Install Drain Joint(Only for Cooling and Heating Unit)
&RQQHFWWKHRXWGRRUGUDLQMRLQWLQWRWKHKROHRQWKHFKDVVLV
&RQQHFWWKHGUDLQKRVHLQWRWKHGUDLQYHQW$VVKRZLQ
)LJ
3. Fix Outdoor Unit
3ODFHWKHRXWGRRUXQLWRQWKHVXSSRUW
)L[WKHIRRWKROHV RIRXWGRRUXQLWZLWKEROWV$VVKRZLQ
)LJ
4. Connect Indoor and Outdoor Pipes
5HPRYHWKHVFUHZRQWKHULJKWKDQGOHRIRXWGRRUXQLWDQG
WKHQUHPRYHWKHKDQGOH$VVKRZLQ)LJ
5HPRYHWKHVFUHZFDSRIYDOYHDQGDLPWKHSLSHMRLQWDWWKH
EHOOPRXWKRISLSH$VVKRZLQ)LJ
3UHWLJKWHQLQJWKHXQLRQQXWZLWKKDQG
7LJKWHQWKHXQLRQQXWZLWKWRUTXHZUHQFK
+H[QXWGLDPHWHUPP 7LJKWHQLQJWRUTXH1P
ĭ 15~20
ĭ 30~40
ĭ 45~55
ĭ 60~65
ĭ 70~75
5HIHUWRWKHIROORZLQJWDEOHIRUZUHQFKPRPHQWRIIRUFH
:
)LJ )LJ
)LJ )LJ
)LJ
)LJ
)LJ
)LJ
At least 3cm above the floor
Screw
Handle
U-shaped curve
Wall
Drain hose
.
Handle
Note: The wiring connect is for reference only,
please refer to the actual one.
N(1) 2 3 L
L
N
N
blue
blue
black
brown
brown
yellow-green
Indoor Unit
DRED
LN
POWER
49
Installation and Maintenance
Service Manual
7KHZDWHU RXWOHWFDQWEHSODFHG LQZDWHULQRUGHUWRGUDLQ
VPRRWKO\$VVKRZLQ)LJ
Liquid valve
Gas valve
Refrigerant charging
vent
Nut of refrigerant
Charging vent
Vacuum pump
Piezometer
Valve cap
Lo Hi
Inner hexagon
spanner
Open
Close
The drain hose can't be fluctuant
The drain hose
can't be fluctuant
The water
outlet can't be
fluctuant
NO. ,WHPVWREHFKHFNHG 3RVVLEOHPDOIXQFWLRQ
1
+DVWKHXQLWEHHQ
LQVWDOOHG¿UPO\"
7KHXQLWPD\GURSVKDNHRU
emit noise.
2
+DYH\RXGRQHWKH
UHIULJHUDQWOHDNDJHWHVW"
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
KHDWLQJFDSDFLW\
3
,VKHDWLQVXODWLRQRI
SLSHOLQHVXI¿FLHQW"
,WPD\FDXVHFRQGHQVDWLRQDQG
water dripping.
4 ,VZDWHUGUDLQHGZHOO"
,WPD\FDXVHFRQGHQVDWLRQDQG
water dripping.
5
,VWKHYROWDJHRISRZHU
VXSSO\DFFRUGLQJWRWKH
YROWDJHPDUNHGRQWKH
QDPHSODWH"
,WPD\FDXVHPDOIXQFWLRQRU
GDPDJHWKHSDUWV
6
Is electric wiring and
pipeline installed
FRUUHFWO\"
,WPD\FDXVHPDOIXQFWLRQRU
GDPDJHWKHSDUWV
7
,VWKHXQLWJURXQGHG
VHFXUHO\"
,WPD\FDXVHHOHFWULFOHDNDJH
8
'RHVWKHSRZHUFRUG
IROORZWKHVSHFL¿FDWLRQ"
,WPD\FDXVHPDOIXQFWLRQRU
GDPDJHWKHSDUWV
9
,VWKHUHDQ\REVWUXFWLRQ
LQDLULQOHWDQGDLURXWOHW"
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
KHDWLQJ
10
7KHGXVWDQG
VXQGULHVFDXVHG
GXULQJLQVWDOODWLRQDUH
UHPRYHG"
,WPD\FDXVHPDOIXQFWLRQRU
GDPDJLQJWKHSDUWV
11
7KHJDVYDOYHDQGOLTXLG
YDOYHRIFRQQHFWLRQSLSH
DUHRSHQFRPSOHWHO\"
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
KHDWLQJFDSDFLW\
The water outlet
can't be placed
in water
1. Use Vacuum Pump
5HPRYHWKHYDOYHFDSVRQWKHOLTXLGYDOYHDQGJDVYDOYH
DQGWKHQXWRIUHIULJHUDQWFKDUJLQJYHQW
&RQQHFWWKHFKDUJLQJKRVHRISLH]RPHWHUWRWKHUHIULJHUDQW
FKDUJLQJYHQWRIJDVYDOYHDQGWKHQFRQQHFWWKHRWKHUFKDUJLQJ
KRVHWRWKHYDFXXPSXPS
2SHQWKHSLH]RPHWHUFRPSOHWHO\DQGRSHUDWHIRUPLQ
WRFKHFNLIWKHSUHVVXUHRISLH]RPHWHUUHPDLQVLQ03D
&ORVHWKHYDFXXPSXPSDQGPDLQWDLQWKLVVWDWXVIRUPLQ
WRFKHFNLIWKHSUHVVXUHRISLH]RPHWHUUHPDLQVLQ03D,I
WKHSUHVVXUHGHFUHDVHVWKHUHPD\EHOHDNDJH
5HPRYHWKHSLH]RPHWHURSHQWKHYDOYHFRUHRIOLTXLGYDOYH
DQGJDVYDOYHFRPSOHWHO\ZLWKLQQHUKH[DJRQVSDQQHU
7LJKWHQWKHVFUHZFDSVRIYDOYHVDQGUHIULJHUDQWFKDUJLQJ
YHQW$VVKRZLQ)LJ
1. Check after Installation
&KHFNDFFRUGLQJWRWKHIROORZLQJUHTXLUHPHQWDIWHUILQLVKLQJ
installation.
2. Test Operation
(1) Preparation of test operation
Ɣ7KHFOLHQWDSSURYHVWKHDLUFRQGLWLRQHULQVWDOODWLRQ
Ɣ6SHFLI\WKHLPSRUWDQWQRWHVIRUDLUFRQGLWLRQHUWRWKHFOLHQW
0HWKRGRIWHVWRSHUDWLRQ
Ɣ3XWWKURXJKWKHSRZHUSUHVV212))EXWWRQRQWKHUHPRWH
controller to start operation.
Ɣ3UHVV02'(EXWWRQWRVHOHFW$872&22/'5<)$1DQG
+($7WRFKHFNZKHWKHUWKHRSHUDWLRQLVQRUPDORUQRW
Ɣ,IWKHDPELHQWWHPSHUDWXUHLVORZHUWKDQ
ć
WKHDLU
FRQGLWLRQHUFDQ¶WVWDUWFRROLQJ
2. Leakage Detection
:LWKOHDNDJHGHWHFWRU
&KHFNLIWKHUHLVOHDNDJHZLWKOHDNDJHGHWHFWRU
:LWKVRDSZDWHU
,IOHDNDJHGHWHFWRULVQRWDYDLODEOHSOHDVHXVHVRDSZDWHUIRU
OHDNDJHGHWHFWLRQ$SSO\VRDSZDWHUDWWKHVXVSHFWHGSRVLWLRQ
DQGNHHSWKHVRDSZDWHUIRUPRUHWKDQPLQ,IWKHUHDUHDLU
EXEEOHVFRPLQJRXWRIWKLVSRVLWLRQWKHUHVDOHDNDJH
8.7 Vacuum Pumping and Leak Detection
8.8 Check after Installation and Test
Operation
)LJ
)LJ
)LJ
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

GREE Cozy GWH18 24 28k Dreds Installation guide

Category
Split-system air conditioners
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI