Equinox Systems Fusion 150 User manual

  • Hello! I am an AI chatbot trained to assist you with the Equinox Systems Fusion 150 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Order code: EQLED005
Fusion 150
12 x 12W Moving Head
User Manual
www.prolight.co.uk Fusion 150 User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablevoltageisbetween
100~240V,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• WARRANTY:Oneyearfromdateofpurchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
www.prolight.co.uk Fusion 150 User Manual
3
Product overview & technical specications
Housing12x12WquadcolourLEDs,theEquinoxFusion150movingheadwashgivessmoothcolourmixingfrom
richsaturatedhuestosubtlepastelshades.Thecompactandlightweightdesignallowsforeasytransportation
andinstallation.The4pushbuttonLEDmenuallowsforeasyaccesstothefunctionsincludingDMX,auto,sound
activeandmaster/slavemodes.LoadedwithadvancedinternalprogrammingbyEquinoxthesoundactiveand
automodesdeliverstunninglightshows.
•12x12Wquad-colourLEDs
•Beamangle:40°
•Pan:540°,Tilt:180°
•DMXchannels:1,4,7or10selectable
•Auto,soundactive,strobeandmasterslavemodes
•0-100%dimming
•4pushbuttonmenuwithLEDdisplay
•IECin/outsockets
•3-pinXLRin/outsocket
•Fancooled
•Suppliedwithhangingbracket
Fusion 150
Specications Fusion 150
Powerconsumption 180W
Powersupply 100~240V,50/60Hz
Dimensions 288x222x190mm
Weight 3.6kg
Ordercode EQLED005
0m 1m 2m 3m 4m 5m
45° - Lux 850 280 100
45°
40 16
222mm
288mm
190mm
www.prolight.co.uk Fusion 150 User Manual
4
Technical specications
01-LEDdisplay
02-Menubutton
03-Downbutton
04-Upbutton
05-Enterbutton
06-Poweroutsocket
07-Powerinsocket
08-Fuse5A250V
09-DMXin
10-On/offswitch
11-DMXout
Inthebox:1 x xture,
1 x power cable,
hanging bracket &
1 x user manual
DMX OUTDMX IN
ONOFF
POWER IN/OUT
01 09 100802 04
03 05
11
06
07
MENU DOWN UP ENTER
www.prolight.co.uk Fusion 150 User Manual
5
Operating instructions
DMX channel selection:
OperatinginDMXcontrolmodegivestheuserthegreatestexibilitywhenitcomestocustomisingor
creatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthextureandeach
xtureindependently.
ToaccesstheDMXchannelmode,pressthe“MODE”buttononthefontoftheunittoshowCHnd
ontheLEDdisplay.Nowpressthe“ENTER”buttonandthechannelmodewillbedisplayed.
Usethe“UP”and“DOWN”buttonstochooseoneofthe1,4,7,or10DMXchannelmodes.Pressthe
“ENTER” buttonagain,thiswillsettheDMXchannel.ThedisplaywillnowdisplayAddr.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
1 channel mode:
Channel Value Function
1 0-7 Blackout
8-127 Autorun(AT01)
128-255 Soundactive(128:lowsensitivity,255:highsensitivity)
www.prolight.co.uk Fusion 150 User Manual
6
Channel Value Function
1 0-255 Panadjustment
2 0-255 Tiltadjustment
3 0-255 0-100%dimming(0:lowbrightness,255:highbrightness)
4 0-255 Red(0:lowbrightness,255:highbrightness)
5 0-255 Green(0:lowbrightness,255:highbrightness)
6 0-255 Blue(0:lowbrightness,255:highbrightness)
7 0-255 White(0:lowbrightness,255:highbrightness)
Channel Value Function
1 0-255 Panadjustment
2 0-255 Tiltadjustment
3 0-255 0-100%dimming(0:lowbrightness,255:highbrightness)
4 0-4 Blackout
5-14 Red
15-24 Green
25-34 Blue
35-44 White
45-54 Cyan
55-64 Yellow
65-74 Orange
75-84 Pink
85-94 Purple
95-104 Pastlegreen(green&white)
105-114 Pastlered(red&white)
115-124 Pastleblue(blue&white)
125-134 Pastlepink(red,blue&white)
135-144 Warmwhite(orange&white)
145-150 Blackout
151-200 Colourfade(151:slowfade,200:fastfade)
201-255 Colourchange(201:slowchange,255:fastchange)
4 channel mode:
7 channel mode:
www.prolight.co.uk Fusion 150 User Manual
7
Operating instructions
Channel Value Function
1 0-255 Panadjustment
2 0-255 Tiltadjustment
3 0-255 Speed(pan&tilt)
4 0-255 0-100%dimming(0:lowbrightness,255:highbrightness)
5 0-255 Red(0:lowbrightness,255:highbrightness)
6 0-255 Green(0:lowbrightness,255:highbrightness)
7 0-255 Blue(0:lowbrightness,255:highbrightness)
8 0-255 White(0:lowbrightness,255:highbrightness)
9 0-4 Blackout
5-14 Red
15-24 Green
25-34 Blue
35-44 White
45-54 Cyan
55-64 Yellow
65-74 Orange
75-84 Pink
85-94 Purple
95-104 Pastlegreen(green&white)
105-144 Pastlered(red&white)
115-124 Pastleblue(blue&white)
125-134 Pastlepink(red,blue&white)
135-144 Warmwhite(orange&white)
145-150 Blackout
151-200 Colourfade(151:slowfade,200:fastfade)
201-255 Colourchange(201:slowchange,255:fastchange)
10 0-127 SoundcontrolviacontrollerisOFF
128-255 SoundcontrolviacontrollerisON
10 channel mode:
Changing the address:
Toaccesstheaddressmenu,pressthe“MODE”buttononthefrontoftheunittoshowAddr
isdisplayed.Pressthe“ENTER”button,theunitshouldnowdisplayA001.Usethe“UP”and“DOWN”
buttonstoselectA001throughA512.Pressthe“ENTER” buttonagain,thiswillsettheaddress.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
www.prolight.co.uk Fusion 150 User Manual
8
Slave mode:
Toaccessslavemodepress“MODE”untilthedisplayshowsSLnd.Pressthe“ENTER”button,theunit
shouldnowdisplaySL 1.Usethe“UP”and“DOWN”buttonstoselecteitherSL 1orSL 2.Press
the“ENTER” buttonagain,thiswillenableyourchosenslavemode.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Adjusting the sound sensitivity:
Toaccessthesoundsensitivitymenupress“MODE”untilthedisplayshowsSoUn.Pressthe“ENTER”
button,theunitshouldnowdisplaythesensitivityinthreedigits.Usethe“UP”and“DOWN”buttonsto
select001through100.Pressthe“ENTER” buttonagain,thiswillsetthesoundsensitivity.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Auto mode:
Toaccessautomodepress“MODE”untilthedisplayshowsAuto.Pressthe“ENTER”button.
Theunitwillnowdisplay At01.Usethe“UP”and“DOWN”buttonstoselecteitherAt01orSou1.
Pressthe“ENTER” buttonagain,thiswillenableyourchosenautomode.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Static colour mode (to use the xture as an uplighter):
Toaccessstaticcolourmodepress“MODE”untilthedisplayshowsAuto.Pressthe“ENTER”button
andusethe“UP”and“DOWN”buttonstoselecteitherStat.Pressthe“ENTER” buttonagain,
thiswillenableyoutochoosebetweenCL01-CL15orFade.
WhenusingtheFadefunctionpressthe“ENTER” buttonandusethe“UP”and“DOWN”buttons
toselectthedesiredfadespeedbetweenSP01-SP31.Pressthe“ENTER” buttontoconrm
thesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Other settings:
Operating instructions
PAn (Xmotorpositive/negativemoveset) YES/NO
tilt (Ymotorpositive/invertmoveset) YES/NO
Led (digitaldisplayON/OFFset) ON/OFF
diSp (digitaldisplayinvert) YES/NO
test (functiontest)
HoUr (totalxtureruntime)
rSEt (reset)
www.prolight.co.uk Fusion 150 User Manual
9
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
www.prolight.co.uk Fusion 150 User Manual
10
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
www.prolight.co.uk Fusion 150 User Manual
11
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
www.prolight.co.uk Fusion 150 User Manual
12
/