Carrier CRFLUEDS006A00 is a flue discharge deflector accessory designed to direct unit flue exhaust vertically instead of horizontally, allowing for smaller unit clearance due to flue exhaust. It is compatible with various Carrier, Bryant, and ICP rooftop units within specific size ranges. The deflector assembly is pre-assembled and includes all necessary hardware for installation. Installation involves removing the existing flue hood, aligning and fastening the deflector assembly to the unit's flue outlet, and restoring power to the unit.

Carrier CRFLUEDS006A00 is a flue discharge deflector accessory designed to direct unit flue exhaust vertically instead of horizontally, allowing for smaller unit clearance due to flue exhaust. It is compatible with various Carrier, Bryant, and ICP rooftop units within specific size ranges. The deflector assembly is pre-assembled and includes all necessary hardware for installation. Installation involves removing the existing flue hood, aligning and fastening the deflector assembly to the unit's flue outlet, and restoring power to the unit.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53480342-01 Printed in U.S.A. Form IIK-CRFLUEDS06-03 Rev. A Pg 1 5-22 Replaces: IIK-CRFLUEDS06-02
Installation Instructions
Part No. CRFLUEDS006A00
PRODUCT USAGE
Carrier Units
Bryant Units
ICP Units
NOTE: Not all unit sizes may be available at this time.
PACKAGE CONTENTS
SAFETY CONSIDERATIONS
Installation of this accessory can be hazardous due to system
pressures, electrical components, and equipment location (such as
a roof or elevated structure). Only trained, qualified installers and
service technicians should install, start-up, and service this
equipment.
When installing this accessory, observe precautions in the
literature, labels attached to the equipment, and any other safety
precautions that apply:
Follow all safety codes
Wear safety glasses and work gloves
Use care in handling and installing this accessory
It is important to recognize safety information. This is the safety-
alert symbol: . When you see this symbol on the unit and in
instructions or manuals, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
GENERAL
The accessory flue discharge deflector directs unit flue exhaust
vertically instead of horizontally. This allows for a smaller unit
clearance due to flue exhaust.
INSTALLATION
1. Close the manual shutoff valve on the gas supply piping.
2. Shut off power to unit and install lockout tag.
3. Remove existing flue hood from unit. Save screws. (See
Fig. 1.)
4. Align deflector assembly (Fig. 2) with outlet and remove
screw in center post that lines up with upper bracket. Save
screw.
5. Fasten deflector assembly inlet with screws removed in
Step 3 to unit flue outlet. (See Fig. 3.)
6. Align upper bracket with empty screw hole in center post.
Secure with screw removed in Step 4. (See Fig. 3.)
7. Return power to unit and remove lockout tag.
8. Open the manual shutoff valve on the gas supply piping.
SERVICE
Remove and clean the screen periodically to ensure proper airflow
and heating efficiency. Inspect full length of flue stack for any
blockages which could impair flue performance. Inspect every
fall, and periodically during heating season.
MODEL UNIT SIZES
48FC 20, 24, 28, 30
48GC 20, 24, 28
48HC 17, 20, 24, 28
48LC 14,17, 20, 24, 26
48TC 17,18, 20, 21, 24, 25, 28, 29, 30
MODEL UNIT SIZES
582K 20, 24, 28, 30
581K 20, 24, 28
581J 17, 20, 24, 28
580J 17, 18, 20, 21, 24, 25, 28, 29, 30
MODEL UNIT SIZES
RGV 210, 240, 300, 336
RGW 210, 240, 300
RGH 181, 183, 210, 213, 240, 243, 300, 303
RGS 210, 214, 240, 244, 300, 304, 333, 336
ACCESSORY PART NUMBER CONTENTS
CRFLUEDS006A00 Flue Deflector, pre-assembled
IMPORTANT: This book contains instructions for the
installation of accessory flue deflector assembly
CRFLUEDS006A00 on the models and sizes listed in the
Product Usage tables. Do not attempt to install this accessory on
any unit NOT INCLUDED in these tables.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
and/or death.
Before beginning any modification, close main gas supply
shutoff valve. Be certain that the main line electrical
disconnect switch is in the OFF position and the lockout tag is
installed. Tag disconnect switch and gas valve with suitable
warning labels.
Single Package Rooftop Units
Gas Heating/Electric Cooling
Select 12.5 to 27.5 Ton
Flue Discharge Deflector Accessory
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53480342-01 Printed in U.S.A. Form IIK-CRFLUEDS06-03 Rev. A Pg 2 5-22 Replaces: IIK-CRFLUEDS06-02
© 2022 Carrier
Fig. 1 — Existing Flue Outlet Hood Fig. 2 — Flue Deflector Assembly
Fig. 3 — Flue Discharge Deflector Installed on Unit
41.44"
4.16" 3.36"
9.72"
Short Chassis Tall Chassis
  • Page 1 1
  • Page 2 2

Carrier CRFLUEDS006A00 User manual

Type
User manual

Carrier CRFLUEDS006A00 is a flue discharge deflector accessory designed to direct unit flue exhaust vertically instead of horizontally, allowing for smaller unit clearance due to flue exhaust. It is compatible with various Carrier, Bryant, and ICP rooftop units within specific size ranges. The deflector assembly is pre-assembled and includes all necessary hardware for installation. Installation involves removing the existing flue hood, aligning and fastening the deflector assembly to the unit's flue outlet, and restoring power to the unit.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI