Conlan M1000 User manual

Type
User manual
Mifare reader
M1000
Art. No: 480060 (black), 480061 (white)
User manual
M1000_usermanual_ENGfeb19
2
Table of Contents
1. Introduction
2. Installation
3. Programming users
3.1 Mastertransponder
3.2 Programming user tags
3.3 Deleting user tags
4. Conguration
4.1 Programming mode
4.2 Backup/cloning
4.3 Settings
4.3.1 OC Split
4.3.2 OC Inverted
4.3.3 Timeout
4.3.4 Free locker
page 3
page 3
page 4
page 4
page 4
page 4
page 5
page 5
page 5
page 5
page 5
page 5
page 6
page 6
3
1. Introduction
M1000isaexibleMifarereaderformanyapplications.Thereaderhas3LED’s(yel-
low, green and red) for indication of approved/rejected tag and for navigation when
conguratingthereaderssettings.80users(possiblein2blocksforindividualout-
put).
InstandbytheyellowLEDislit( ○ ○)
ByapprovedtagorcardtheyellowandgreenLEDarelit( ○)
ByrejectedtagorcardtheredLEDislit(○ ○ )
2. Installation
Mount the reader on a even surface.
Connectthewirestopowersupply,lockingdevice,assemblyboxetc.
Note:Rightafterthevoltageisappliedlightsall3LED’sandthebuzzersounds.
RightaftertheyellowLEDashesandthebuzzerissilent.
3. Programming user tags
3.1 Master transponder
BeforeyoucanusetheM1000youhavetoprogramaMastertransponder
(indication = * ○ ○).ShowthattagyouwantasMastertransponder,agreenlight
conrmstheprogrammingandtheM1000isnowreadyforprogrammingusertags
andconguratingthesettings.
3.2 Programming new user tags
TheM1000has2outputs(yellowandwhitewire)thatcanactivateeachlockingdevice.
Bydefaultatcivatesalltagsoutput2.Tosplittheoutputssee“OCSplit”.
* ○ → ○ * ○ → ○
Toexittheprogramming,waitfor30secondsordisconnectandreconnectthe
voltage.
3.3 Deleting user tags
Deleting individual users
* *
The M1000 can also delete all users at once, delete a lost user and delete the master
transponder.Usetheenclosedcongurationschemeasaguide.
4
Show the Master tag
1 time
Show a Mifare tag
Show a Mifare tag
etc.
Show the Master tag
2 times
Show a Mifare tag
Show a Mifare tag
etc.
4.Conguration
4.1 Programming mode
ToconguretheM1000,thereadermustbedisconnectedandreconnected(forabout
2seconds).NowtheMastertranspondercanconguretheM1000’ssettings.Please
seethecongurationschema// markings.
RemembertoshowtheMasterTransponderwithin10secondstoallowyoutochange
theM1000’scongurations(timeout).
Thefollowingcongurationsonlyworkafterpoweron/oasdescribed.
4.2 Backup/cloning
TheM1000’sinformationcanbestoredandloadedwithaBackupcard
(Art.No.480080).Pleaseseetheenclosedcongurationschemeforfurther
information.
4.3 Settings
These settings can split the outputs, invert the outputs, and set the timeout.
Usetheenclosedcongurationscheme.
4.3.1 OC Split(1ashontheyellowLED)
Fromthefactory,theloadedtagsenablebothoutputs(userspace1to80).Thisset-
tingdividestheuserlocations.User1to40activatesoutput2(yellowwire)anduser
space 41 to 80 activates output 1 (white wire).
Show master transponder for toggle ( = split, = combined).
4.3.2 OC1 and OC2 inverted(2or3ashesontheyellowLED)
ThesefunctionsinverttheM1000’soutputs(2ashesforoutput1and3ashesfor
output 2).
( = inverted, = not inverted).
5
6
4.3.3 Timeout (4ashesontheyellowLED)
ThisfunctionsetstheM1000’stimeouttime.Showthemastertranspondertostart,
thebuzzergivesabeepforeverysecond,showthemastertransponderagaintoend
the count.
4.3.4 Free locker (5ashesontheyellowLED)
TheFreelockerfunctioncanbeusedforaccesscontrol,especiallywheretheuser
often switches.
Showthereaderacardortag,andifthecabinetisfree,itwilllockandcanonlybe
unlocked with the same card or tag.
Free locker timeout
Countforhours,soifyouwantittobesetto4hours,waitfor4seconds.
Save0forthereadernottoopenafterxhours,butonlywhenthecard/tagis
showed to the reader again. Default is set to 10 hours.
User position 1 resets free locker.
7
ThankyouforchoosingConlan’sproducts.
For further assistance, please contact
Our support service.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Conlan M1000 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI