4
PL-PRO DMC OWNER’S MANUAL
FURMAN’s PL-PRO DMC FEATURES
SMP• (Series Mul-Stage Protecon) with EVS (Extreme Voltage Shutdown)
LiFT• (Linear Filtering Technology) with zero ground contaminaon
Switchable/Dimmable true RMS current and laboratory precise digital voltage meter
Front panel mounted USB charger
Two SmoothTrack retractable, long-life, low-heat, front panel LED lights with dimmer-power switch for rack illuminaon
BNC connector on the rear panel accepts any standard (12VAC 0.5 amp) gooseneck lamp to illuminate the rear of your rack
(Furman GN-I and GN-LED accessory gooseneck lamps are best for this applicaon)
Eight rear panel AC outlets (three with wide spacing and hook and loop straps to accommodate and secure transformers - wall
warts)
One front panel convenience outlet
20 amp (2400 wa)
Five year limited warranty
INTRODUCTION
Thank you for purchasing a Furman Classic Series power condioner, and congratulaons on your choice. Classic Series power
condioners feature Furman’s revoluonary Series Mul-Stage Protecon (SMP) circuit, Extreme Voltage Shutdown (EVS), and our
exclusive Linear Filtering Technology (LiFT). Together, these technologies comprise precisely what our customers have come to expect
from Furman - uncompromised AC protecon and puricaon. Our Classic Series has been precisely engineered to exceed the crical
demands of audio/video professionals, contractors, broadcasters, and musicians alike.
SMP (SERIES MULTI-STAGE PROTECTION)
Furman’s SMP surge suppression virtually eliminates service calls and costly “down me”. Tradional surge suppression circuits sacri-
ce themselves when exposed to mulple transient voltage spikes, requiring the dismantling of your system and repair of your surge
suppressor. Not so with Furman’s SMP. Damaging transient voltages are safely absorbed, clamped, and dissipated. Your connected
equipment is protected, while your Furman protects itself!
Unique to Furman’s SMP is its unparalleled clamping voltage, dened as the amount of voltage that is allowed to pass through to your
equipment when the protecon device is subjected to a transient surge or spike. While other designs oer clamping voltages that are
well above 330 Vpk, Furman’s SMP clamps at 188 Vpk, (133 VAC RMS) even when tested with mulple 6000 Vpk - 3000 amp surges!
This unprecedented level of protecon is only available with Furman’s SMP technology.
EVS (EXTREME VOLTAGE SHUTDOWN)
Furman’s trusted over-voltage (EVS) circuitry protects against prolonged overvoltage condions, such as accidental connecons to 208
or 240 VAC, or an intermient neutral. It does so by monitoring the incoming voltage and, when an unsafe condion is detected,
triggering a relay which shuts o the incoming power unl the overvoltage condion is corrected and the power switch is reset.
LIFT (LINEAR FILTERING TECHNOLOGY)
Unfortunately, tradional AC power condioners have been designed for unrealisc laboratory condions. Prior technologies, wheth-
er mulple-pole or convenonal series-mode lters, could actually harm audio and video performance more than they help, due to
the resonant peaking of their anquated, non-linear designs. Under certain condions, these designs can actually add more than 10
dB of noise to the incoming AC line! Worse sll, lost digital data, the need to reboot digital presets, or destrucon of sensive digital
converters are frequently caused by excessive voltage spikes and AC noise contaminang the equipment ground. Furman’s LiFT takes
a dierent approach, ensuring opmal performance through linear AC noise ltering with no ground contaminaon.
PL-PRO DMC ADDITIONAL FEATURES
The PL-PRO DMC features SmoothTrack LED rack lights which produce virtually no heat and provide an extremely long lifespan. A dim-
mer control for the rack lights allows the user to adjust the level of illuminaon (by rotang clockwise/counterclockwise) or switch the
lamps on and o (by pushing the knob in). A rear mounted BNC jack accepts any standard (12VAC 0.5 amp) gooseneck lamp for rear
rack illuminaon.
The PL-PRO DMC is equipped with a front panel convenience AC outlet and eight rear panel outlets in two isolated banks. The outlets
in Bank A are spaced to accommodate transformer plugs (wall warts) which may be secured with the included hook and loop straps.
5
FRANÇAIS
ENGLISH
ESPAÑOL
Since the banks are isolated from each other, it is recommended to connect analog equipment into Bank A and digital equipment
into Bank B (or vice versa). The PL-PRO Cs 20 amp (2400 wa) capacity is supplied from a robust 12 AWG, 10 foot AC cord.
Addionally, the PL-PRO DMC oers a switchable laboratory precision digital meter that displays incoming voltage in
1-volt steps or true RMS current in 0.1 amp steps. The voltmeters accuracy is ±1.5 volts and features a tri-color voltage range
indicator. This informs the user whether voltage is in or out of a safe range, even from a distance too great to accurately read the
displayed voltage.
SAFETY INFORMATION
To obtain best results from your Furman Classic Series power condioner, please read this manual carefully before using.
WARNING
To reduce the risk of electrical shock, do not expose this equipment to rain or moisture. Dangerous high voltages are present inside
the enclosure. Do not remove the cover. Refer servicing to qualied personnel only. The lightning ash with an arrowhead symbol
is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of
sucient magnitude to constute a risk of electric shock.
IMPORTANT SAFETY INSTRUCTIONS
(Please read prior to installaon)
1. Please read and observe all safety and operang instrucons before installing your Furman Classic Series power condioner.
Retain these instrucons for future reference.
2. Your Classic Series condioner should not be used near water – for example, near a bathtub, washbowl, kitchen sink, laundry tub,
in a wet basement, or near a swimming pool.
3. Do not place your Classic Series condioner near high heat sources such as radiators, heat registers, stoves, or other appliances
that produce extreme heat.
4. The Furman PL-PRO DMC should only be connected to a 120 VAC, 50Hz/60Hz, 20 amp grounded electrical outlet. Do not defeat
the ground or change polarizaon of the power plug.
5. Route the AC power cord and other cables so that they are not likely to be walked on, tripped over, or stressed. Pay parcular
aenon to the condion of the cords and cables at the plugs and at the point where they exit your Furman condioner. To
prevent risk of re or injury, damaged cords and cables should be replaced immediately.
6. Clean your Furman condioner with a damp cloth only. Do not use solvents or abrasive cleaners. Never pour liquid on or into the
unit.
7. Your Furman condioner should be serviced by qualied service personnel when:
• The power supply cord or the plug has been frayed, kinked, or cut.
• Objects have fallen or liquid has been spilled into the unit.
• The unit has been exposed to rain or extreme moisture.
• The unit does not appear to operate normally.
• The “Protecon OK” indicator is not lit.
• The unit has been dropped, or the enclosure has been damaged.
• The retractable LED lights have failed.
8. Your Furman condioner requires that a safety ground be present for proper operaon. Any aempt to operate the unit without
a safety ground is considered improper operaon and could invalidate the warranty.
9. Do not aempt to service your Furman condioner beyond what is described in this manual. All other servicing should be
referred to qualied service personnel.
OPERATION
RETRACTABLE SMOOTH TRACK RACK LIGHTS, REAR PANEL LAMP AND DIMMER CONTROL:
The Furman Classic Series power condioners ulize a dimmer control for the two retractable Smooth Track light tubes. The dim-
mer knob controls the brightness of both front panel lamps. Turn it clockwise to increase brightness; turn it counterclockwise to
decrease brightness. The knob is also a momentary power switch for the lamps: push it in to turn the lamps on or o. When the
6
PL-PRO DMC OWNER’S MANUAL
lamps are not in use, we recommend turning the dimmer fully counterclockwise, or pushing the knob to the o seng to maximize
the life of the LED’s. Whether the light tubes are fully extended or ush with the front panel, there will be no appreciable heat regard-
less of the dimmer seng due to the eciency of our full light spectrum LED’s.
All Furman Classic Series Condioners feature a rear rack BNC socket which will accept any 12 VAC (0.5A) gooseneck lamp assembly
(such as the Furman GN-LED or GN-I). Simply slide the BNC plug over the socket and rotate clockwise unl the connector snaps into
the locked posion. The rear rack lamp can be powered on or o with the rear light switch which is adjacent to the BNC connector.
ULTRA-LOW RESISTANCE MAGNETIC POWER SWITCH / CIRCUIT BREAKER:
Furman’s Classic Series 20 amp capacity power switch is specically designed to stand up to the enormous high in-rush current de-
mands of many power ampliers. Addionally, Furman magnec circuit breakers are not sensive to temperature, and will not raise
the AC impedance as do many, less costly thermal breaker. If the 20 amp RMS current capacity of the PL-PRO C is exceeded, the spring
tensioned-switch will immediately switch to the o posion. You will need to switch the toggle back to the on posion once the prob-
lem is corrected (typically by eliminang one component, or unl the RMS current does not exceed 20 amps or 2400 was).
EXTREME VOLTAGE SHUTDOWN (EVS) INDICATOR:
The Extreme Voltage LED indicator is normally o. It is located within the meter lens assembly directly above the blue voltage / cur-
rent LED’s, though during normal use it will NOT be visible.
The Extreme Voltage indicator monitors a hazard common in the entertainment, remote broadcast, and AV contractor industries: wir-
ing faults. For example: accidental connecon to 208VAC where 120VAC is expected, or an open series neutral from a 208 to 240VAC
electrical service. The Furman EVS circuit senses voltages that are so high that operaon would be impossible and shuts the power
down before damage can occur.
Upon inially applying power to these units, the Extreme Voltage indicator will light and a red “Extreme Voltage” label will appear at
the top of the meter lens if the input voltage is above the extreme voltage cuto.
NOTE: If the mains power is above the high cuto voltage and has caused the EVS circuit to remove power from the PL-PRO DMCs
outlets, it cannot restore power without the operator manually turning the unit o, then on again. Avoid turning the unit back on
without rst checking the source of the problem and changing the AC source (if necessary).
PROTECTION OK INDICATOR:
Although the Furman SMP circuit assures virtually maintenance-free protecon from transient voltage spikes and surges, nature has a
way of occasionally creang electrical forces that are beyond the capabilies of ANY surge suppression device to absorb without some
degree of damage (such as a direct lightning hit in an outdoor applicaon). In the rare instance that this occurs, the green “Protecon
OK” LED indicator, located at the boom right of the meter lens assembly, will dim. If this happens, some level of protecon from volt-
age surges will remain, but the PL-PRO DMCs clamping voltage rang will be compromised and the unit must be returned to Furman
for service.
NOTE: Furman’s Classic Series power condioners do not compensate for high or low AC line voltage. If you frequently move your
rack to dierent locaons, derive power from generators, use very long extension cords, travel internaonally, or are in an area prone
to brownouts, you may benet from the use of one of Furman’s AC Voltage Regulators.
SWITCHABLE DIGITAL VOLTAGE AND TRUE RMS CURRENT METER:
Furman’s laboratory precision AC digital voltmeter connually measures incoming voltages within a typical tolerance of +/-1.5VAC. It
should be noted that the voltage reading is incoming.
Furman’s laboratory precision True RMS digital current meter connually measures the total circuit AC load, within a typical tolerance
of +/- 0.5 amp. Because these meters feature true RMS technology, the current readings are accurate regardless of load condions
(capacive, inducve, or resisve). To switch between voltage and current, press the buon labeled “Line Voltage/Current. Hold this
buon down for two seconds to dim the brightness of the display.
VOLTAGE RANGE INDICATOR:
This indicator is located in the lower le corner of the digital volt / amp meter lens assembly. When AC voltage is within 5 volts (+/-) of
a nominal 120VAC source, this tri-color indicator will be green (opmal). However, if the voltage is between 110 to 114VAC or be-
tween 126 to 130VAC, the indicator will turn amber (cauon - not opmal). If the incoming voltage is in an extreme range (below 110
or above 130), the indicator will turn red. This range is far from opmal, and may be potenally damaging to some equipment.
USB CHARGER:
The Furman PL-PRO Cs USB charger provides an easy way to recharge many popular electronic accessories as well as cellular com-
7
FRANÇAIS
ENGLISH
ESPAÑOL
126 VAC, consider installing a Furman voltage regulator.
SERVICE
If you require technical support or equipment service, please contact the Furman Service Department at 707-763-1010. You may
also email [email protected].
All equipment being returned for repair must have a Return Authorizaon (RA) number. To get an RA number, please call the
Furman Customer Service Department.
Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment,
and that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please pro-
vide a note giving your name, address, phone number, RA number and a descripon of the problem.
5 YEAR LIMITED WARRANTY
SAVEYOURSALESRECEIPT!The receipt is your proof of purchase and conrms the product was purchased at an authorized Furman
dealer. It will need to be submied to Furman in order to process any warranty claims.
Furman, a brand of Panamax Inc., warrants its PL-PRODMC (the “Product”) as follows:
Furman warrants to the original purchaser of the product that the product sold hereunder will be free from defects in material and
workmanship for a period of ve years from the date of purchase. If the product does not conform to this Limited Warranty during
the warranty period (as herein above specied), purchaser shall nofy Furman of the claimed defects by calling 707-763-1010 or
via email ([email protected]). If the defects are of such type and nature as to be covered by this warranty, Furman
shall authorize purchaser to return the product to Furman headquarters. Warranty claims MUST be accompanied by a copy of the
original purchase invoice or receipt showing the purchase date. Shipping charges to Furman headquarters must be prepaid by the
purchaser of the product. Furman shall, at its own expense, furnish a replacement product or, at Furman’s opon, repair the defec-
ve product. Return shipping charges back to purchaser will be paid by Furman.
THEFOREGOINGISINLIEUOFALLOTHERWARRANTIES,EXPRESSORIMPLIED,INCLUDINGBUTNOTLIMITEDTOTHEIMPLIED
municaon devices by simply plugging the re-charge cord into the front panel socket. Please note that as there are currently many
standards for USB, some devices may not be compable with our charger.
TRANSFORMER PLUG (WALL WART) SECURING LOOPS:
Your 20 amp Furman Classic Pro Series condioner features rear panel AC outlets that are widely spaced for plug transformers (wall
warts). Addionally, these may be secured for transport with hook and loop straps (included). Each outlet has threaded screw
holes on either side to accommodate the hook and loop straps.
TROUBLESHOOTING
1.)Symptom: No power to the AC outlets.
PossibleCause: The circuit breaker (located on the front panel) has tripped due to excessive load.
AconNeeded: Unplug one piece of equipment from the Furman condioner and manually turn the unit o, then on again.
2.)Symptom: No power to the AC outlets, “Protecon OK” indicator is not lit.
PossibleCause: Either the AC outlet to which your Furman condioner is connected has no AC voltage present, or the protecon
circuitry in your unit has been compromised.
AconNeeded: Plug the Furman condioner into an AC receptacle where a nominal 120 VAC is present. If the problem persists,
contact Furman for service.
3.)Symptom: Extreme Voltage (EVS) indicator lit.
PossibleCause: Input voltage is above 140V causing power to the units outlets to be shut down. Addionally, if the voltage is
below 85V – 90V at turn on, the unit will not allow AC voltage to reach the outlets.
AconNeeded: Correct the line voltage, then turn the Furman condioner on. If the voltage present is below 114 VAC or above
8
PL-PRO DMC OWNER’S MANUAL
WARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE.
Furman does not warrant against damages or defects arising out of improper use or abnormal handling of the product, or against
defects or damages arising from improper installaon. This warranty shall be cancelable by Furman at its sole discreon if the product
is modied in any way without wrien authorizaon from Furman or Panamax Inc. This warranty also does not apply to products upon
which repairs have been aected or aempted by persons other than pursuant to wrien authorizaon by Furman or Panamax Inc.
THISWARRANTYISEXCLUSIVE. The sole and exclusive obligaon of Furman shall be to repair or replace the defecve product in
the manner and for the period provided above. Furman shall not have any other obligaon with respect to the products or any part
thereof, whether based on contract, tort, strict liability or otherwise. Under no circumstances, whether based on this Limited Warranty
or otherwise, shall Furman be liable for incidental, special, or consequenal damages. This Limited Warranty states the enre obliga-
on of Furman with respect to the product. If any part of this Limited Warranty is determined to be void or illegal, the remainder shall
remain in full force and eect.
SPECIFICATIONS
CURRENTRATING:
20 amps
OPERATINGVOLTAGE:
90 to 139 VAC
OVERVOLTAGESHUTDOWN:
140 VAC typically
SPIKEPROTECTIONMODES:
Line to neutral, zero ground leakage
SPIKECLAMPINGVOLTAGE:
188 VAC peak @ 3,000 Amps, 133 VAC RMS
RESPONSETIME:
1 nanosecond
MAXIMUMSURGECURRENT:
6,500 amps
NOISEATTENUATION:
10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz
Linear aenuaon curve from 0.05 - 100 Ohms line impedance
DIMENSIONS:
1.75” H x 19” W x 10.5” D.
WEIGHT:
12 lbs. (5.5 kg.)
CONSTRUCTION:
Steel chassis, .120” brushed and black anodized aluminum front panel; glass epoxy printed circuit boards
POWERCONSUMPTION:
15 VA
SAFETYAGENCYLISTING:
TUV
9
FRANÇAIS
ENGLISH
ESPAÑOL
PL-PRO DMC FRONT PANEL
PL-PRO DMC REAR PANEL
convenience outlet
dual pull-out lamps
wall wart spacing for
large transformers
bnc lamp connector
bnc lamp power switchisolated ac outlet banks
10 ft. 12 gauge power cable
front lamp dimmer
meter control
button
master
power switch
digital led voltmeter/
ammeter and status
indicators
usb
charger
22
PL-PRO DMC OWNER’S MANUAL
Notes:
1690 Corporate Circle • Petaluma, California, USA 94954
Phone: 877-486-4738 • Fax: 707-763-1310
www.FurmanSound.com
PL-PRODMC_RevA
/