Honeywell R8184G4009 User manual

  • Hello! I am an AI chatbot trained to assist you with the Honeywell R8184G4009 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
R8184G Protectorelay Oil
Primary Addendum
24 V, 50/60 Hz.
Follow the instructions provided in 69-0617—1 for
installation and checkout. Wire the control system as
shown in Fig. 1.
TRADELINE
The R8184G4082 (45 sec.) and R8184G4090 (15 sec.)
are equipped with dry contacts for remote alarm. When
the safety switch opens, the alarm switch contacts close to
initiate alarm. The alarm contact rating is 25 VA at
Fig. 1—Typical hookup for TRADELINE R8184G4082 and R8184G4090.
Home and Building Control Home and Building Control Helping You Control Your World
Honeywell Inc. Honeywell Limited—Honeywell Limitée
1985 Douglas Drive North 740 Ellesmere Road
Golden Valley, Minnesota 55422 Scarborough, Ontario
M1P 2V9
QUALITY IS KEY
G.G. • 5-92 • © Honeywell Inc. 1992 • Printed in U.S.A. • Form Number 69-A0617—1
JUNCTION BOX
BLACK
L1
(HOT)
L2
LIMIT
BURNER
MOTOR
IGNITION
OIL VALVE
(OPTIONAL)
ORANGE
WHITE
BILATERAL
SWITCH
CAPACITOR
TRIAC
1K1
R2
R8184G PROTECTORELAY CONTROL
SAFETY
SWITCH
R1
1K2
M5172
SAFETY
SWITCH
HEATER
1K
CAD CELL
1
F
F
T
T
THERMOSTAT
2
LINE VOLTAGE
THERMOSTAT
2
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
TO USE R8184 WITH LINE VOLTAGE CONTROLLER, JUMPER T-T TERMINALS AND CONNECT LINE VOLTAGE THERMOSTAT IN
SERIES WITH LIMIT CONTROLLER.
1
2
RED
RED
SAFETY
SWITCH
TO REMOTE
ALARM CIRCUIT
/