CEL-MAR ADA-DNB400 User manual

  • Hello! I am an AI chatbot trained to assist you with the CEL-MAR ADA-DNB400 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
User manual
DNB-400
Passive 1-WIRE Bus Splitter
1
io_dnb-400_en_v0.15
DNB-400
Copyright © 2001-2013 CEL-MAR sp.j.
Contents
1. GENERAL INFORMATION...................................................................................................................................................................... 3
1.1. WARRANTED INFORMATION ...................................................................................................................................................... 3
1.2. GENERAL CONDITIONS FOR SAFE USE....................................................................................................................................3
1.3. CE LABEL....................................................................................................................................................................................... 3
1.4. ENVIRONMENTAL PRESERVATION.............................................................................................................................................3
1.5. SERVICE AND MAINTENANCE..................................................................................................................................................... 3
2. PROPERTIES.......................................................................................................................................................................................... 3
3. SOLUTIONS............................................................................................................................................................................................ 3
4. DNB-400-9P VIEW.................................................................................................................................................................................. 4
5. DNB-400-8PL VIEW................................................................................................................................................................................ 4
6. THE SIGNALS ON THE PINS OF MODULAR SOCKET: IN, OUT, LINK PORTS...................................................................................5
7. EXAMPLE SOLUTIONS.......................................................................................................................................................................... 5
7.1. EXAMPLE CONNECTION OF 3-WIRE BUS..................................................................................................................................5
7.2. EXAMPLE CONNECTION OF 2-WIRE BUS..................................................................................................................................6
7.3. EXAMPLE CONNECTION OF TWO SPLITTERS DNB-400-8PL AND DNB-4009P......................................................................7
8. SPECIFICATIONS................................................................................................................................................................................... 8
9. VERSIONS.............................................................................................................................................................................................. 8
2
DNB-400
1. GENERAL INFORMATION
Thank you for your purchase of CEL-MAR Company product. This product has been completely tested and is covered by two year
warranty on parts and operation from date of sale.
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48
41 362-12-46 or e-mail support@cel-mar.pl.
1.1. WARRANTED INFORMATION
CEL-MAR Company gives the two year guarantee on the DNB-400 splitter. In case of being damaged it will be repair or the
damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any
unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be
repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the CEL-MAR Company.
CEL-MAR Company under no circumstances won't be responsible for ensuing damage from improper using the product or as a result
of random causes: the lightning discharge, the flood, the fire and the like.
CEL-MAR Company is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing
from using or the impossibility of using this product.
In specific cases CEL-MAR Company discontinue all warranties and in particular do not follow the user manual and do not accept
terms of warranty by the user.
1.2. GENERAL CONDITIONS FOR SAFE USE
The device should be installed in a safe and stable places, the powering cable should be arranged so as not to be exposed to
trampling, attaching, or pulling out of the circuit.
Do not put device on the wet surface.
Do not connect devices for nondescript powering sources,
Do not damage or crush powering wires.
Do not make connection with wet hands.
Do not adapt, open or make holes in casings of the device!
Do not immerse device in water or no other liquid.
Do not put the fire opened on device sources: candles, an oil lamps and the like.
1.3. CE LABEL
The CE symbol on the device CEL-MAR means compatibility with electromagnetic compatibility Electromagnetic
Compatibility Directive EMC 89/336/EWG. Declaration of Conformity is available by contact with Technical Service
(email: support@cel-mar.pl; phone: +48 41 362-12-46).
1.4. ENVIRONMENTAL PRESERVATION
This sign on the device inform about putting expended device with other waste materials. Device should send to the
recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)
1.5. SERVICE AND MAINTENANCE
It is recommended to check the status of modular sockets and the sensors connecting cables, to eliminate the influence of mechanical
damage on the quality of measurement .
Technical support is available at number +48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail support@cel-mar.pl..
2. PROPERTIES
Supporting 1-WIRE bus of 2-wire (2W) and 3-wire (3W),
Separation of 1-Wire bus for 8+LINK/9 branches, with the total length should not exceed 260m for the 64 sensors,
Signalling of voltage on 1-WIRE Bus of 3-wire,
Bus connection via standard modular sockets for RJ45,
Designed to operating with structural cabling,
Casing adapt to rail mounting according to DIN35 / TS35, standard
Casing dimensions ( W x D x H) 88mm x 58mm x 90 mm.
3. SOLUTIONS
Splitter DNB-400 is used to for connection of digital sensors as: DES-300, DES-215, DES-200, DTS-103, DTS-107 to remote multi-
point measurement temperature system in:
premises with structured cabling,
automation cubicles,
data communication cubicles,
devices
and outside temperature via the serial bus 1-WIRE.
Application of 1-Wire bus enables:
the cooperation of many sensors connected to the same data lines,
the deployment of sensors in various locations up to 260m,
powering the sensors from the bus,
guarantee the correct transmission of measurement data secure checksum CRC
3
DNB-400
4. DNB-400-9P VIEW
On the below picture is shown the Passive 1-WIRE Bus Splitter DNB-400-9P in version with input IN port and 9 output ports.
5. DNB-400-8PL VIEW
On the below picture is shown the Passive 1-WIRE Bus Splitter DNB-400-8PL in version with input IN port and 8 output ports and one
LINK port for connection of another splitter.
4
DNB-400
9cm
5,8cm
OUT6 OUT7 OUT8 OUT9OUT5
OUT1 OUT2 OUT3 OUT4IN
VDD
8,8cm
PASSIVE 1-WIRE BUS SPLITTER
DNB - 400-9P
9cm
5,8cm
OUT5 OUT6 OUT7 OUT8OUT4
OUT1 OUT2 OUT3 LINKIN
VDD
8,8cm
PASSIVE 1-WIRE BUS SPLITTER
DNB - 400-8PL
6. THE SIGNALS ON THE PINS OF MODULAR SOCKET: IN, OUT, LINK PORTS
7. EXAMPLE SOLUTIONS
7.1. EXAMPLE CONNECTION OF 3-WIRE BUS
5
DNB-400
The signals on the pins of modular socket :
1. NW – not use (RJ45/8WIRE cable – white-orange)
2. NW – not use (RJ45/8WIRE cable - orange)
3. VDD – power +5VDC (RJ45/8WIRE cable - white-green)
4. DQ – data line (RJ45/8WIRE cable - blue)
5. GND – ground line (RJ45/8WIRE cable - white-blue)
6. NW - not use (RJ45/8WIRE cable - green)
7. NW - not use (RJ45/8WIRE cable - white-brown)
8. NW - not use (RJ45/8WIRE cable - brown)
81
V+
1-WIRERS485/422
ADA-401WP
GND
VDD
1-W
Rx+
10 – 30VDC
2W
Tx+ / A
Tx- / B
GND
Rx-
Power
Vss-
Vss+
V-
DNB-400-9P
12578
OUT7
1 2 5 7 8
OUT6
1 2 5 7 8
OUT5
1 2 5 7 8
OUT9
1 2 5 7 8
OUT8
34578
OUT2
3 4 5 7 8
OUT4
3 4 5 7 8
OUT3
3 4 5 7 8
IN
1-WIRE (3W) Bus
VDD
GND
DQ
DES-300-TTA
Sensor
DQ
VDD
DQ
DES-300-T
Sensor
GND
VDD
GNDGND
DQ
VDD
DQ
VDD
GND
VDD
GND
DQ
DES-300-TH
Sensor
1-WIRE (3W) Bus
VDD
GND
DQ
DES-300-T
Sensor
VDD
GND
DQ
DES-300-TTA
Sensor
1-WIRE (3W) Bus
VDD
GND
DQ
DES-300-TTA
Sensor
VDD
GND
DQ
DES-300-T
Sensor
VDD
GND
DQ
DES-300-TAPS
Sensor
3 4 5 7 8
OUT1
1-WIRE (3W) Bus
VDD
GND
DQ
DES-300-T
Sensor
VDD
GND
DQ
DES-300-T
Sensor
VDD
GND
DQ
DES-300-TH
Sensor
RJ45/8WIRE Cable
7.2. EXAMPLE CONNECTION OF 2-WIRE BUS
6
DNB-400
DNB-400-9P
12578
OUT7
1 2 5 7 8
OUT6
1 2 5 7 8
OUT5
1 2 5 7 8
OUT9
1 2 5 7 8
OUT8
34578
OUT2
3 4 5 7 8
OUT4
3 4 5 7 8
OUT3
3 4 5 7 8
IN
1-WIRE (3W) Bus
VDD
GND
DQ
DS18B20
Sensor
DQ
VDD
DQ
DS18B20
Sensor
GND
GNDGND
DQ DQ-R
GND-R
DQ
GND
DQ-R
GND-R
VDD
GND
DQ
DS18B20
Sensor
1-WIRE (2W) Bus
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
1-WIRE (3W) Bus
VDD
GND
DQ
Czujnik
DS18B20
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
3 4 5 7 8
OUT1
1-WIRE (2W) Bus
VDD
GND
DQ
Czujnik
DS18B20
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
RJ45/8WIRE Cable
V+
1-WIRERS485/422
ADA-401WP
GND
VDD
1-W
Rx+
10 – 30VDC
2W
Tx+ / A
Tx- / B
GND
Rx-
Power
Vss-
Vss+
V-
7.3. EXAMPLE CONNECTION OF TWO SPLITTERS DNB-400-8PL AND DNB-4009P
7
DNB-400
1-WIRE (3W) Bus
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
DNB-400-9P
1 2 5 7 8
OUT7
1 2 5 7 8
OUT6
1 2 5 7 8
OUT5
1 2 5 7 8
OUT9
1 2 5 7 8
OUT8
3 4 5 7 8
OUT2
3 4 5 7 8
OUT4
3 4 5 7 8
OUT3
3 4 5 7 8
IN
3 4 5 7 8
OUT1
1-WIRE (2W) Bus
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
LINK
DNB-400-8PL
1 2 5 7 8
OUT6
1 2 5 7 8
OUT5
1 2 5 7 8
OUT4
1 2 5 7 8
OUT8
1 2 5 7 8
OUT7
3 4 5 7 8
OUT2
3 4 5 7 8
LINK
3 4 5 7 8
OUT3
3 4 5 7 8
IN
3 4 5 7 8
OUT1
RJ45/8WIRE Cable
1-WIRE (2W) Bus
VDD
GND
DQ
DS18B20
Sensor
VDD
GND
DQ
DS18B20
Sensor
V+
1-WIRERS485/422
ADA-401WP
GND
VDD
1-W
Rx+
10 – 30VDC
2W
Tx+ / A
Tx- / B
GND
Rx-
Power
Vss-
Vss+
V-
8. SPECIFICATIONS
Parameters Data
casing material Noryl
Operating temperature from -30°C to +70°C
Degree of protection IP20
Dimensions 88 mm x 58 mm x 90 mm
Weight 0,1 kg
Storage and transport
outdoor temperature -30 ÷ +70°C
Relative air humidity 5 ÷ 95% - noncondensing
9. VERSIONS
DNB-400 - Order example:
Product symbol: DNB-400-8PL
8PL - Splitter with IN port and 8 OUT ports
and additionally LINK port for connection
other splitter.
Versions:
With IN port and with 9 OUT ports 9P
With IN port and 8 OUT port and additionally with LINK port for connection of other
splitter. 8PL
8
DNB-400
Dear Customer,
Thank you for purchasing CEL-MAR Company product.
We hope that this user manual help simplify your network of 1-Wire sensor for industrial applications. We also wish to remind you
that CEL-MAR Company are a manufacturer of the widest selections of data communications products in the world in applications
such as: data transmission converters in RS232, RS485, RS422, USB, Current Loop, Fibre-Optic and Ethernet Converters and many
others.
We welcome your feedback so please contact us to tell how you like our products and how we can satisfy you present and future
needs.
CEL-MAR sp.j.
Zakład Informatyki i Elektroniki
str. Ściegiennego 219C
25-116 Kielce, POLSKA
Tel.................................................... : +48 41 362-12-46
Tel/fax.............................................. : +48 41 361-07-70
Web................................................. : http://www.cel-mar.pl/en
Office................................................: office@cel-mar.pl
Sales department............................ : sales@cel-mar.pl
Technical information ..................... : support@cel-mar.pl
/