ANSMANN ALCT 6-24/1, ALCT 6-24/2 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the ANSMANN ALCT 6-24/1 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!


Automatic charger for lead acid-/sealed lead acid batteries 6 V;12 V; 24 V.

> For automatic charging of all types of lead acid batteries and sealed lead acid batteries with
output voltage 6 V; 12 V; 24 V
> Protection against short circuit and wrong polarity
> Protection against overcharging
> Charging with IU-curve
> Suitable for float charging
> Trickle charging

> Please read the operating instructions before use.
> Keep your charger in a dry place (indoor use only)
> Only for use within this specification
> In order to avoid the risk of fire and /or electrical shock, the charger must be protected
against high humidity and water
> Do not open or reconstruct the charger
> In case of defect, please return to an authorised service center
> Do not subject the equipment to high temperatures or to high humidity.
> To clean the charger, please disconnect it from the mains
> Only use a dry cloth for cleaning
> Do not operate the device without adult supervision
> Keep out of reach of children.
If the safety instructions are not followed, this may cause damage to the device or serious
injury to the user.

green LED “POWER” on: ready for use
red LED “CHARGE” on: charging of the battery
red LED “CHARGE” off: end of charging / trickle charging

Only for charging rechargeable lead acid batteries with 6 V (3 cells); 12 V (6 cells) or 24 V (12
cells). Do not charge other types of batteries - Danger of explosion!

Connect the battery with the battery clips of the charger. Pay attention to the correct polarity.
The red clip with (+), the the black clip with (-). Plug the charger into a convenient mains
socket. After connecting the charger will start the charging procure automatically. The green
LED shows reday for use, the red LED indicates charging. After charging the red charging LED
switches off and the battery is provided with trickle charging. The battery is now fully charged
and ready for use.

When charging lead acid cells, explosive gases can develop. Avoid open fire and sparks.

Input: 230V 50Hz
Voltage of the battery end of charging voltage max. charging current
ALCT6-24/1 ALCT 6-24/2
6 Volt 6,9 V 1000 mA 1500 mA
12 Volt 13,8 V 1000 mA 2000 mA
24 Volt 27,6 V 700 mA 1000 mA
/