1.
INTRODUCTION
The On-Q/Legrand Category 5 LCD Module (P/N CM1003) and LCD Flat Panel
Display (P/N CM1002-XX) (see Figure 1) integrate seamlesly with our Camera
Solution. The Display Module supplies power and video signals for up to two
Flat Panel Displays, allowing the homeowner to easily monitor various places
throughout the house, such as the front door area or a baby's room.
2.
DESCRIPTION
The Category 5 LCD Display Module acts as the interface between On-Q
Cameras and the On-Q LCD Flat Panel Display. Features include:
One wire installation — power and video are supplied
over a Cat 5e cable to each display
Built-in sleep timer which shuts off the connected LCD Display
Units after 1/2 hour (28 minutes)
Camera number markings which correspond with switch
on the LCD Display Unit
Easy to install and configure
Included One-Bay Module Mounting Bracket (P/N 364890-01) (see Figure 2)
3.
POWER REQUIREMENTS
The Cat 5 LCD Module and Display's power requirements are::
Voltage: +15 VDC
Current: 375 mA
Power: 5.6 W Max
Polarity: Tip (+) Barrel (-)
Note: On-Q/Legrand offers several options for power, which range from a
dedicated power cube designed to accommodate one module to power solutions
designed to accommodate multiple module installations.
Please refer to the On-Q/Legrand Catalog or the On-Q/Legrand website
(http://www.onqlegrand.com) for more information.
INSTRUCTION / INSTALLATION SHEET
Cat 5 LCD/ flat panel color monitor,3.5" and
LCD Display Module
IS-0359 Rev. O
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
©Copyright 2006 by On-Q/Legrand All Rights Reserved. Page 2 of 2
Figure 3
Figure 4
4.
INSTALLATION
Refer to Figure 4 during installation.
A. Home-run one Cat 5e cable from the enclosure to the Cat 5 LCD
Display, which is typically installed in a deep triple-gang box.
B. Terminate both ends of the Cat 5e line, using RJ-45 connectors,
from the LCD display module and monitor to the T568A wiring
standard shown in Figure 3.
C. Insert the RJ-45 plug at the Cat 5 LCD Display into the RJ-45 jack
located on the rear circuit board.
D. Insert the RJ-45 plugs at the Cat 5 LCD Display Module into either
of the two RJ-45 jacks labeled "Out To Display"
E. Connect up to two RCA cables from the Cat 5 Camera Module to
the LCD Display Module.
F. Make final connections, apply power to the Cat 5 LCD Module,
and verify system functionality.
Example: Figure 4 shows one way the Cat 5 LCD Display and Module can be integrated with various On-
Q/Legrand Cameras:
The video feed from the infrared camera is routed to the Cam1 input on the display module.
The video feeds from the two bullet cameras (and the infrared camera) are sequenced and
routed to the Cam 2 input on the display module.
In this case, flipping the toggle switch on the LCD monitor to "I" displays the infrared camera
video feed continuously.
Flipping the toggle switch to "II" displays and loops the sequenced video feeds from all three
cameras. The rate at which they sequence is controlled on the Cat 5 Camera Module.