Englander AC-16 Installation guide

Category
Wood stove
Type
Installation guide

Englander AC-16 is an optional heat circulation blower that can be installed to improve the heat distribution of your freestanding stove. It requires periodic lubrication, which should be performed no less than every three months of normal operation. The fan speed should be run on “Low” when the unit is operating at lower burn settings and set to “High” for high burns. When routing the power cord, be sure that the cord does not come into contact with any hot surface.

Englander AC-16 is an optional heat circulation blower that can be installed to improve the heat distribution of your freestanding stove. It requires periodic lubrication, which should be performed no less than every three months of normal operation. The fan speed should be run on “Low” when the unit is operating at lower burn settings and set to “High” for high burns. When routing the power cord, be sure that the cord does not come into contact with any hot surface.

P.O. Box 206 Monroe, VA 24574 www.heatredefined.com Phone: (800) 516-3636 Fax: (434) 929-4810
P.O. Box 206 Monroe, VA 24574 www.heatredefined.com Teléfono: (800) 516-3636 Fax: (434) 929-4810
Pellet Stoves Estufas a gránulos de madera Poêles à granules
Wood Stoves Estufas a leña Poêles à bois
Multi-Fuel Stoves Estufas multi-combustible Poêles multicombustibles
AC-16 Blower Installation Instruction Guide
Guía de instrucciones de instalación del ventilador AC-16
Guide d'installation du ventilateur AC-16
ALWAYS FOLLOW ALL CODES AND OWNER’S MANUALS!
¡SIEMPRE SIGA TODOS LOS CÓDIGOS Y MANUALES DEL PROPIETARIO!
TOUJOURS SUIVRE TOUS LES CODES ET LES MODES D'EMPLOI!
Install AC-16 Optional Blower as shown,
using the (4) supplied mounting screws.
Instale el ventilador opcional AC-16 como se
muestra, usando los tornillos de montaje
suministrados (4).
Installer le ventilateur optionnel AC-16
comme indiqué, à l'aide des (4) vis de fixation
fournies.
For our freestanding models with “12”, “13”or
“17” in model number (or 30 if 2011 and later)
Para nuestros modelos de pie con “12”, “13” o
“17” en el número de modelo (o 30 si el 2011 y
mas tarde)
Pour nos modèles sur pieds avec un numéro de
modèle “12”, “13” ou “17” (ou 30, si 2011 et
p
lus tard
)
For our older models with an external blower tunnel, install AC-16 Optional Blower
here, using the (4) supplied mounting screws.
Para nuestros modelos anteriores con un túnel externo del ventilador, instale el
ventilador opcional AC-16 aquí, usando los tornillos de montaje suministrados (4).
Pour nos modèles plus anciens avec un conduit externe de ventilateur, installer le
ventilateur optionnel AC-16 ici, à l'aide des (4) vis de fixation fournies.
The optional heat circulation blower on this stove requires periodic lubrication; this lubrication should be performed no less than
every three months of normal operation. To properly lubricate the blower, use an eye dropper or similar dispensing device to drip
5-7 droplets of SAE 20 oil into the oil port on the side of the blower motor.
El soplador de circulación de calor opcional en esta estufa requiere la lubricación periódica; esta lubricación no debería ser
realizada menos que cada tres meses de la operación normal. Para lubricar correctamente al soplador, use un cuentagotas o el
dispositivo de distribución similar para gotear 5-7 gotitas de SAE 20 petróleo en el puerto del aceite en el lado del motor de
soplador.
Le ventilateur en option de circulation de chaleur sur ce poêle nécessite un graissage périodique; cette lubrification doit être
effectuée au moins tous les trois mois de fonctionnement normal. Pour lubrifier correctement le ventilateur, utilisez un compte-
gouttes ou un dispositif semblable de distribution pour faire couler 5 à 7 gouttes d'huile SAE 20 dans l'orifice à cet effet, situé sur
le côté du moteur du ventilateur.
P.O. Box 206 Monroe, VA 24574 www.heatredefined.com Phone: (800) 516-3636 Fax: (434) 929-4810
P.O. Box 206 Monroe, VA 24574 www.heatredefined.com Teléfono: (800) 516-3636 Fax: (434) 929-4810
Pellet Stoves Estufas a gránulos de madera Poêles à granules
Wood Stoves Estufas a leña Poêles à bois
Multi-Fuel Stoves Estufas multi-combustible Poêles multicombustibles
AC-16 Blower Installation Instruction Guide – for Models with “30” in Model Number
-And- our ‘Smartstove’ units
Guía de instrucciones de instalación del ventilador AC-16
Guide d'installation du ventilateur AC-16
Install AC-16 Optional Blower as shown, using the (4)
supplied mounting screws.
Instale el ventilador opcional AC-16 como se muestra,
usando los tornillos de montaje suministrados (4).
Installer le ventilateur optionnel AC-16 comme indiqué,
à l'aide des (4) vis de fixation fournies.
The optional heat circulation blower on this stove requires periodic lubrication; this lubrication should be performed no less than
every three months of normal operation. To properly lubricate the blower, use an eye dropper or similar dispensing device to drip
5-7 droplets of SAE 20 oil into the oil port on the side of the blower motor.
El soplador de circulación de calor opcional en esta estufa requiere la lubricación periódica; esta lubricación no debería ser
realizada menos que cada tres meses de la operación normal. Para lubricar correctamente al soplador, use un cuentagotas o el
dispositivo de distribución similar para gotear 5-7 gotitas de SAE 20 petróleo en el puerto del aceite en el lado del motor de
soplador.
Le ventilateur en option de circulation de chaleur sur ce poêle nécessite un graissage périodique; cette lubrification doit être
effectuée au moins tous les trois mois de fonctionnement normal. Pour lubrifier correctement le ventilateur, utilisez un compte-
gouttes ou un dispositif semblable de distribution pour faire couler 5 à 7 gouttes d'huile SAE 20 dans l'orifice à cet effet, situé sur
le côté du moteur du ventilateur.
For our freestanding models with “30” in
model number and ‘Smartstove’ units
Para nuestros modelos de pie con “30” en el
número de modelo y ‘Smartstove’
Pour nos modèles sur pieds avec un numéro de
modèle “30”et ‘Smartstove’
Install AC-16 Blower here,
using the (4) supplied
mounting screws
120 VOLTS, 60Hz, 0.75 AMPS, 2900 RPM
DANGER: RISK OF ELECTRIC SHOCK.
DISCONNECT POWER BEFORE SERVICING
UNIT.
120 VOLTS, 60Hz, 0,75 AMPÈRE, 2900
TR/MIN
DANGER : RISQUE DE CHOC ÉLECTRIQUE.
BRANCHER L’ALIMENTATION AVANT
TOUTE INTERVENTION SUR L’APPAREIL.
OPERATING INSTRUCTIONS:
This unit is set up for
installation of an optional 2-speed
blower motor. The fan speed
should be run on “Low” when the
unit is operating at lower burn
settings, and set to “High” for high
burns. When routing the power
cord, be sure that the cord does
not come into contact with any hot
surface.
ALWAYS FOLLOW ALL CODES AND OWNER’S MANUALS!
¡SIEMPRE SIGA TODOS LOS CÓDIGOS Y MANUALES DEL PROPIETARIO!
TOUJOURS SUIVRE TOUS LES CODES ET LES MODES D'EMPLOI!
INSTRUCTIONS DE FONCTIONNEMENT : Cet appareil est prévu pour l'installation d'un moteur de soufflante en option à 2 vitesses. La vitesse
de la soufflante doit être réglée sur « Bas » quand le poêle fonctionne avec une combustion lente, et sur « Haut » quand le feu est vif. Pour le
cheminement du cordon d’alimentation, veillez à ce que celui-ci n'entre en contact avec aucune surface chaude.
  • Page 1 1
  • Page 2 2

Englander AC-16 Installation guide

Category
Wood stove
Type
Installation guide

Englander AC-16 is an optional heat circulation blower that can be installed to improve the heat distribution of your freestanding stove. It requires periodic lubrication, which should be performed no less than every three months of normal operation. The fan speed should be run on “Low” when the unit is operating at lower burn settings and set to “High” for high burns. When routing the power cord, be sure that the cord does not come into contact with any hot surface.