Briteq PD-32SH/GERMAN, PD-32SH/FRA-BEL Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Briteq PD-32SH/GERMAN Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ENGLISH USER MANUAL
BRITEQ
®
1/27 PD-32SH
OPERATION MANUAL
Thank you for buying this BriteQ
®
product. To take full advantage of all possibilities, please read these
operating instructions very carefully.
FEATURES
This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.
This 3-phase power distributor is designed to improve safety in both mobile, rental and fixed installations.
Choice of different outputs for maximum flexibility (rental companies!):
o
6x earthed 16A mains outlet sockets: (2 sockets per phase, 3 different models available)
o
1x 16PIN industrial rectangular connector: output for use with standard wiring for rental multi-cables
o
1x 19PIN industrial round connector: output for use with standard wiring for rental multi-cables
Designed and build to the highest European and international safety standards.
Oversized internal wiring for increased reliability!
32A 4pole circuit breaker protects ALL outputs, including the 32A output to the next unit. In case of
emergency all 3 phases AND the neutral are disconnected!
The 30mA, 4pole residual current circuit breaker prevents electrical shocks
Accurate digital 3-digit voltmeters per phase
Accurate digital 3-digit ampere meters per phase
Two C16 (16A - 1P+N) automatic circuit breakers per phase
1,5m long mains input cable (3x 32A, 5wire), equipped with CEE (3P+N+E) 32A inlet plug
CEE (3P+N+E) outlet socket (3x 32A, 5wire) for bypass
3 different models available:
o
PD-32SH/FR: French/Belgian 16A blue mains sockets
o
PD-32SH/GE: German 16A blue schukos (CEE 7/4)
o
PD-32SH/SA: South African 16A blue mains sockets
Extremely robust 19”/3U metal housing
BEFORE USE
Check the contents:
Check that the carton contains the following items:
PD-32SH
User manual
Some important instructions:
Before you start using this unit, please check if there’s no transportation damage. Should there be any, do
not use the device and consult your dealer first.
Important: This device left our factory in perfect condition and well packaged. It is absolutely necessary
for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects
or problems caused by disregarding this user manual.
Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user
manual.
To protect the environment, please try to recycle the packing material as much as possible.
ENGLISH USER MANUAL
BRITEQ
®
2/27 PD-32SH
SAFETY INSTRUCTIONS:
To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance or may even cause damages.
This unit is for indoor use only.
Don’t place metal objects or spill liquid inside the unit. No objects filled with liquids, such as vases, shall be
placed on this appliance. Electric shock or malfunction may result. If a foreign object enters the unit,
immediately disconnect the mains power.
No naked flame sources, such as lighted candles, should be placed on the appliance.
Don’t cover any ventilation openings as this may result in overheating.
Prevent use in dusty environments and clean the unit regularly.
Keep the unit away from children.
Inexperienced persons should not operate this device.
Maximum save ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.
To be sure that the automatic circuit breakers work properly, the unit may not be used on altitudes above
2000m.
This unit should be operated with an alternating voltage between 380V and 400V / 50Hz.
Never exceed the maximum power indicated on this appliance!
Never use or connect this appliance during thunderstorms: the unit can be destroyed due to overvoltage!
Always unplug the unit when it is not used for a longer time or before you start servicing.
The electrical installation should be carried out by qualified personal only, according to the regulations for
electrical and mechanical safety in your country.
Check that the available voltage is not higher than the one stated on the rear panel of the unit.
The socket inlet shall remain operable for disconnection from the mains.
The power cord should always be in perfect condition: switch the unit immediately off when the power cord
is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard
Never let the power-cord come into contact with other cables!
This appliance must be earthed to in order comply with safety regulations.
In order to prevent electric shock, do not open the cover. Apart from the mains fuse there are no user
serviceable parts inside.
Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse of the same
type and electrical specifications!
In the event of serious operating problems, stop using the appliance and contact your dealer immediately.
Please use the original packing when the device is to be transported.
Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
CAUTION
CAUTION: To reduce the risk of electric shock, do not
remove the top cover. No user-serviceable parts inside.
Refer servicing to qualified service personnel only.
The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the
use or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may
be of sufficient magnitude to constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the user to the presence
of important operation and maintenance (servicing) instructions in the literature accompanying
this appliance.
This symbol means: indoor use only
This symbol means: Read instructions
The device is suitable for mounting on standard flammable surfaces. Standard flammable
surfaces include building materials such as wood and wood-based materials more than 2mm
thick.
ENGLISH USER MANUAL
BRITEQ
®
3/27 PD-32SH
FUNCTIONS
A. GENERAL CIRCUIT BREAKER: protects ALL outputs, including the 32A output to the next unit. In case
of emergency all 3 phases AND the neutral are disconnected.
B. RESIDUAL CURRENT CIRCUIT BREAKER: this is a vital security device of the power distributor!
When someone accidentally touches one of the mains conductors, a current leak through the body of
this person could result in a lethal (deadly) shock. As soon as such current leakage in the installation is
detected, the power distributor outputs will be disconnected. The maximum allowable current leakage is
set to 30mA. Under normal working conditions the lever on the right should be in upward position.
Important: the functions of this device should be tested every 30days by pushing the test button on top:
as a result the outputs should be immediately disconnected from the mains.
C. INDIVIDUAL CIRCUIT BREAKERS: each of the 3 phases is secured by two C16 automatic circuit
breakers. Under normal working conditions the lever should be in upward position.
D. VOLT & AMPERE METERS: each of the 3 phases (L1, L2 & L3) have their individual meters.
E. 32A INPUT: 1,5m long mains input cable (3x 32A, 5wire), equipped with CEE (3P+N+E) inlet plug.
F. 32A OUTPUT: CEE (3P+N+E) outlet socket (3x 32A, 5wire), can be used to feed-through up to 32A
3phase current. Make sure that the total input current will not be exceeded!
G. 16A OUTPUTS: Each output has its individual circuit breaker (C) on the front panel
Output 1: 230V/16A output socket connected to phase1 (L1) and protected by breaker 1 (C)
Output 2: 230V/16A output socket connected to phase1 (L1) and protected by breaker 2 (C)
Output 3: 230V/16A output socket connected to phase2 (L2) and protected by breaker 3 (C)
Output 4: 230V/16A output socket connected to phase2 (L2) and protected by breaker 4 (C)
Output 5: 230V/16A output socket connected to phase3 (L3) and protected by breaker 5 (C)
ENGLISH USER MANUAL
BRITEQ
®
4/27 PD-32SH
Output 6: 230V/16A output socket connected to phase3 (L3) and protected by breaker 6 (C)
H. Ground Connection of the housing
I. 16-pin connector:
Pin 1: output connected to phase1 (L1) and protected by breaker 1 (C)
Pin 2: output connected to phase1 (L1) and protected by breaker 2 (C)
Pin 3: output connected to phase2 (L2) and protected by breaker 3 (C)
Pin 4: output connected to phase2 (L2) and protected by breaker 4 (C)
Pin 5: output connected to phase3 (L3) and protected by breaker 5 (C)
Pin 6: output connected to phase3 (L3) and protected by breaker 6 (C)
Pin 9, 10, 11, 12, 13, 14 = Neutral
Pin 7, 8, 15, 16 = not used
Side connector (cover) = Ground
J. Round 19-pin connector:
Pin 1: 230V/16A output connected to phase1 (L1) and protected by breaker 1 (C)
Pin 3: 230V/16A output connected to phase1 (L1) and protected by breaker 2 (C)
Pin 5: 230V/16A output connected to phase2 (L2) and protected by breaker 3 (C)
Pin 7: 230V/16A output connected to phase2 (L2) and protected by breaker 4 (C)
Pin 9: 230V/16A output connected to phase3 (L3) and protected by breaker 5 (C)
Pin 11: 230V/16A output connected to phase3 (L3) and protected by breaker 6 (C)
Pin 2, 4, 6, 8, 10, 12 = Neutral
Pin 13, 14, 15, 16, 17, 18 = Ground
Pin 19 = not used
INSTALLATION GUIDELINES
DANGER TO LIFE / EQUIPMENT:
This unit may only be installed and electrically connected by an
authorized and qualified electrician!
Electrical installation should strictly follow all safety rules and
technical norms for electrical installations in your country!
The complete installation should be approved by an authorized
expert before it will be taken into operation! Each change to an
existing installation should be re-approved as well!
Before connecting ANY equipment you should ALWAYS check the
voltage on the 3 phases: not following this rule can cost you a lot
of money due to broken equipment. Briteq CANNOT be held
responsible in such cases!
MAINS INPUT: the unit should be connected to the mains via a 5pole 380-400V 32A CEE socket. The
maximum overall power is 22.080Watt which may never be exceeded!
OUTPUTS: each phase is connected via 2 separate 16A output sockets. The maximum power per phase
is 7.360Watt, each 16A output socket support maximum 3.680Watt which may never be exceeded!
ENGLISH USER MANUAL
BRITEQ
®
5/27 PD-32SH
MAINTENANCE
DANGER TO LIFE:
Switch the unit off and unplug the mains cable BEFORE servicing!
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
The unit and its installation conditions should be inspected and approved every 3 months by an authorized
expert!
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Power Input: IEC60309-standard, CEE-32A industrial plug
380V400V / 50Hz, 3phase, 5wire (3P+N+E)
Maximum overall power: 22.080Watt (3x 32A)
Maximum power per phase: 7.360Watt (32A)
Maximum power per output: 3.680Watt (16A)
Protection class: class I (only to be connected to class I outlets)
Max. Leakage current: 30mA
Automatic fuses / phase: 2x C16 (I
n
=16A, instantaneous tripping current = 5x I
n
)
Diameter Power cord: 5x 6mm² (H07RN-F 5G6)
Diameter internal wiring: 32A-wires: 10AWG (5,2mm²) 16A-wires: 14AWG (2,1mm²)
Size: see drawings
Weight: 8.8 kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
WWW.BRITEQ-LIGHTING.COM
Copyright © 2014 by BEGLEC NV
‘t Hofveld 2C ~ B1702 Groot-Bijgaarden ~ Belgium
Reproduction or publication of the content in any manner, without express permission of the publisher, is prohibited.
/