31141

V-ZUG 31141 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the V-ZUG 31141 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation instructions
Ventilation protective plate set
for glass ceramic hobs (induction)
Niche mounting
J402.48-5
29.10.14
4
These installation instructions are valid for:
Induction (without Wok), Teppan Yaki, Quicklight
Requirement with 3 mm ventilation gap at the front (version with integrated gasket)
Installing the ventilation protective plate:
A Remove the top drawer or front panel.
B Line up the template provided with the front side panel or the underside of the work surface.
Insert an awl to make the hole for the screw where indicated by the template and repeat on the opposite side panel.
C Turn in the screws, stopping when there is a gap of 1 mm underneath the screw head.
D Slide on the ventilation protective plate and position it so it juts out approx. 2 mm from the front of the side panel.
If you are installing the version of the plate that has a seal, check that the foam seal is in the correct position before tightening the
screws.
E Replace the drawer or front panel and check that the gap does not exceed 0.5 mm.
Validity
Ventilation protective plate set for installation above drawer
Article per model type Item no. Use Remark
- for all Quicklight models
- only for induktion models
GK26TIQ...,
GK47TIMPS..., GK46TIPS...,
GK46TIMPS...
H6.1082 For niche width 550 mm
Without integrated gasket for
induction with front air gap of 5 mm
H6.1083 For niche width 600 mm
H6.1084 For niche width 825 mm
H6.1085 For niche width 900 mm
For all other induction models
H6.1086 For niche width 550 mm
With integrated gasket for front air
gap of 3 mm
H6.1087 For niche width 600 mm
H6.1088 For niche width 825 mm
H6.1089 For niche width 900 mm
Installation
A ventilation protective plate is required to ensure sufficient ventilation for the hob.
There must be a distance of at least 17.5 mm between the underside of the unit and the ventilation protective plate.
39356
(2.5)
ø4
C
min. 15
(17.5)
(50)
Drawer/cabinet
Fan
E
A
m
ax.
0.
5
55.5
5..10
min. 67.5
(30)
min. 3
Example for work surface 30 mm thick
2
D
B
Caution:
Mains cable must not touch
the protective plate!
Air gap along entire width of
cabinet element min. 17.2 cm²
/