Generation Lighting HS586OPBZ1BMPT Installation guide

Type
Installation guide

This manual is also suitable for

1
Installation Instructions for
Fusion Jack 4" Square and Round Flush Canopy
1.7
001_-CK FJ
980 4FSJ RC
Install the Canopy
GP I :ENERAL RODUCT NFORMATION
This product is suitable for indoor dry locations only.
This fixture is intended to be used utilizing NEC compliant junction
boxes with enough room to house the transformer.
Halogen ballast dimensions: 2.66”L x 1.30”H x 0.83”D
LED driver dimensions: 2.76”L x 1.62”H x 0.91”D
Model numbers ending in “- ” or “- 277” can be dimmedLED LED
with a low-voltage electronic dimmer, have a rated maximum output
of 60 watts, and are compatible with elements.LED
All other model numbers can be dimmed with a standard
incandescent dimmer, have a rated maximum output of 60 watts,
and are not compatible with elements.LED
Turn the power to the electrical box off.
In accordance with local electrical codes, ground the canopy
braided copper wire and the green transformer wire (if
attached).
Connect the white transformer wire to the neutral power line
wire with a wire nut.
Connect the black transformer wire to the hot power line
wire with a wire nut.
Place the transformer and all the wires inside the electrical
box. Use the adhesive pad to secure the transformer in the
electrical box.
Connect the canopy wires to the red transformer wires with
wire nuts.
Mount the canopy crossbar to the electrical box with the two
long #8-32 screws.
POWER
LINE WIRES
12 VOLT
TRANSFORMER
WIRES
#8-32 SCREW
CANOPY
CROSSBAR
CEILING
ELECTRICAL BOX
Fusion Jack
1A
1
2
3
4
5
6
7
4
6
2
7 7
6
3
CAUTION RISK OF FIRE-
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
2
FUSION JACK PORT
FIXTURE
FUSION JACK
Screw the fixture Fusion Jack into the Fusion Jack port.
Turn the power on.
Place the canopy cover over the crossbar and screw the cap
onto the threaded crossbar post.
CEILING
THREADED POST
CAP
CANOPY
COVER
1B 1C
9
10
8
SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, 60077IL
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2016 Lighting.All rights reserved.The " Lighting" graphic is aLBL LBL
registered trademark of Lighting. Lighting reserves the right toLBL LBL
change specifications for product improvements without notification.