Toshiba RAV-HM301MUT-E Owner's manual

Category
Split-system air conditioners
Type
Owner's manual
AIR CONDITIONER (SPLIT TYPE)
Owner’s Manual R32
Indoor Unit
<Compact 4-Way type>
RAV-HM301MUT-E
RAV-HM401MUT-E
RAV-HM561MUT-E
Model name:
For commercial use
English
–1–
Original instruction
Contents
1 Precautions for safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Part names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3 Part names and functions of the remote controller . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5 OFF timer operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
6 Adjustment of wind direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9 Operations and performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
10 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
11 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Thank you very much for purchasing TOSHIBA Air Conditioner.
Please read this owner’s manual carefully before using your Air Conditioner.
Be sure to obtain the “Owner’s manual” and “Installation manual” from constructor (or dealer).
Request to constructor or dealer
Please clearly explain the contents of the Owner’s manual and hand over it.
ADOPTION OF R32 REFRIGERANT
This Air Conditioner has adopted a refrigerant HFC (R32) which does not destroy the ozone layer.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Thank you for purchasing this Toshiba air conditioner.
Please read carefully through these instructions that contain important information which complies with the
“Machinery Directive 2006 / 42 / EC”, and ensure that you understand them.
After reading these instructions, be sure to keep them in a safe place together with the Owner’s Manual and
Installation Manual supplied with your product.
Generic Denomination: Air Conditioner
Definition of Qualified Installer or Qualified Service Person
The air conditioner must be installed, maintained, repaired and removed by a qualified installer or qualified service
person. When any of these jobs is to be done, ask a qualified installer or qualified service person to do them.
A qualified installer or qualified service person is an agent who has the qualifications and knowledge described in
the table below.
Agent Qualifications and knowledge which the agent must have
Qualified installer
(*1)
The qualified installer is a person who installs, maintains, relocates and removes the air conditioners
made by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and
remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been
instructed in such operations by an individual or individuals who have been trained and is thus
thoroughly acquainted with the knowledge related to these operations.
The qualified installer who is allowed to do the electrical work involved in installation, relocation and
removal has the qualifications pertaining to this electrical work as stipulated by the local laws and
regulations, and he or she is a person who has been trained in matters relating to electrical work on
the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been
instructed in such matters by an individual or individuals who have been trained and is thus thoroughly
acquainted with the knowledge related to this work.
The qualified installer who is allowed to do the refrigerant handling and piping work involved in
installation, relocation and removal has the qualifications pertaining to this refrigerant handling and
piping work as stipulated by the local laws and regulations, and he or she is a person who has been
trained in matters relating to refrigerant handling and piping work on the air conditioners made by
Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an
individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge
related to this work.
The qualified installer who is allowed to work at heights has been trained in matters relating to working
at heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she
has been instructed in such matters by an individual or individuals who have been trained and is thus
thoroughly acquainted with the knowledge related to this work.
Qualified service
person (*1)
The qualified service person is a person who installs, repairs, maintains, relocates and removes the
air conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, repair,
maintain, relocate and remove the air conditioners made by Toshiba Carrier Corporation or,
alternatively, he or she has been instructed in such operations by an individual or individuals who have
been trained and is thus thoroughly acquainted with the knowledge related to these operations.
The qualified service person who is allowed to do the electrical work involved in installation, repair,
relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local
laws and regulations, and he or she is a person who has been trained in matters relating to electrical
work on the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been
instructed in such matters by an individual or individuals who have been trained and is thus thoroughly
acquainted with the knowledge related to this work.
The qualified service person who is allowed to do the refrigerant handling and piping work involved in
installation, repair, relocation and removal has the qualifications pertaining to this refrigerant handling
and piping work as stipulated by the local laws and regulations, and he or she is a person who has
been trained in matters relating to refrigerant handling and piping work on the air conditioners made
by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an
individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge
related to this work.
The qualified service person who is allowed to work at heights has been trained in matters relating to
working at heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he
or she has been instructed in such matters by an individual or individuals who have been trained and
is thus thoroughly acquainted with the knowledge related to this work.
1-EN 2-EN
–2–
Meanings of symbols displayed on the air conditioner
These safety cautions describe important matters concerning safety to prevent injury to users or other people and
damages to property. Please read through this manual after understanding the contents below (meanings of
indications), and be sure to follow the description.
MEANINGS OF SYMBOLS DISPLAYED ON THE UNIT
Indication Meaning of Indication
WARNING Text set off in this manner indicates that failure to adhere to the directions in the warning could result in
serious bodily harm (*1) or loss of life if the product is handled improperly.
CAUTION Text set off in this manner indicates that failure to adhere to the directions in the caution could result in
slight injury (*2) or damage (*3) to property if the product is handled improperly.
*1: Serious bodily harm indicates loss of eyesight, injury, burns, electric shock, bone fracture, poisoning, and other
injuries which leave aftereffect and require hospitalization or long-term treatment as an outpatient.
*2: Slight injury indicates injury, burns, electric shock, and other injuries which do not require hospitalization or long-
term treatment as an outpatient.
*3: Damage to property indicates damage extending to buildings, household effects, domestic livestock, and pets.
WARNING
(Risk of fire)
Read the OWNER’S MANUAL carefully before operation.
Service personnel are required to carefully read the OWNER’S MANUAL and INSTALLATION MANUAL
before operation.
Further information is available in the OWNER’S MANUAL, INSTALLATION MANUAL, and the like.
Warning indications on the air conditioner unit
Warning indication Description
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect all remote electric power supplies before servicing.
WARNING
Moving parts.
Do not operate unit with grille removed.
Stop the unit before the servicing.
CAUTION
High temperature parts.
You might get burned when removing this panel.
CAUTION
Do not touch the aluminum fins of the unit.
Doing so may result in injury.
CAUTION
BURST HAZARD
Open the service valves before the operation, otherwise there might be the
burst.
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect all remote
electric power supplies
before servicing.
WARNING
Moving parts.
Do not operate unit with grille
removed.
Stop the unit before the servicing.
CAUTION
High temperature parts.
You might get burned
when removing this panel.
CAUTION
Do not touch the aluminum
fins of the unit.
Doing so may result in injury.
CAUTION
BURST HAZARD
Open the service valves before
the operation, otherwise there
might be the burst.
3-EN 4-EN
–3–
1Precautions for safety
The manufacturer shall not assume any liability for the damage caused
by not observing the description of this manual.
General
• Carefully read Owner’s Manual before starting the air conditioner.
There are many important things to keep in mind for daily operation.
• Ask for installation to be performed by the dealer or a professional.
Only a Qualified installer (*1) is able to install an air conditioner. If a
non-qualified person installs an air conditioner, it may result in
problems such as fire, electric shock, injury, water leakage, noise and
vibration.
• Do not use any refrigerant different from the one specified for
complement or replacement. Otherwise, abnormally high pressure
may be generated in the refrigeration cycle, which may result in a
failure or explosion of the product or an injury to your body.
Do not install the air conditioner in a place where the operation sound
of the outdoor unit may cause a disturbance. (Especially at the
boundary line with a neighbor, install the air conditioner while
considering the noise.)
• This appliance is intended to be used by expert or trained users in
shops, in light industry, or for commercial use by lay persons.
Transportation and storage
To transport the air conditioner, wear shoes with protective toe caps,
protective gloves, and other protective clothing.
To transport the air conditioner, do not take hold of the bands around
the packing carton. You may injure yourself if the bands should break.
• Before stacking the packing cartons for storage or transportation,
heed the precautions written on the packing cartons. Failure to heed
the precautions may cause the stack to collapse.
The air conditioner must be transported in stable condition. If any part
of the product broken, contact your dealer.
When the air conditioner must be transported by hand, carry it by two
or more people.
WARNING
Installation
• Only a Qualified installer (*1) or Qualified service person (*1) is
allowed to carry out the electrical work of the air conditioner. Under
no circumstances must this work be done by an unqualified individual
since failure to carry out the work properly may result in electric
shocks and/or electrical leaks.
• After the installation work has been completed, have the installer
explain about the circuit breaker positions. In the event that trouble
has occurred in the air conditioner, set the circuit breaker to the OFF
position, and contact a service person.
• If the unit is installed in a small room, take appropriate measures to
prevent the refrigerant from exceeding the limit concentration even if
it leaks. Consult the dealer from whom you purchased the air
conditioner when you implement the measures. Accumulation of
highly concentrated refrigerant may cause an oxygen deficiency
accident.
Do not install the air conditioner in a location that may be subject to a
risk of expire to a combustible gas. If a combustible gas leaks and
becomes concentrated around the unit, a fire may occur.
• Use the company-specified products for the separately purchased
parts. Use of non-specified products may result in fire, electric shock,
water leakage or other trouble. Have the installation performed by a
professional.
• Confirm that earthing is performed correctly.
Operation
• Before opening the intake grille of the indoor unit or service panel of
the outdoor unit, set the circuit breaker to the OFF position. Failure to
set the circuit breaker to the OFF position may result in electric
shocks through contact with the interior parts. Only a Qualified
installer (*1) or Qualified service person (*1) is allowed to remove the
intake grille of the indoor unit or service panel of the outdoor unit and
do the work required.
• Inside the air conditioner are high-voltage areas and rotating parts.
Due to the danger of electric shocks or of your fingers or physical
objects becoming trapped in the rotating parts, do not remove service
panel of the outdoor unit. When work involving the removal of these
parts is required, contact a Qualified installer (*1) or a Qualified
service person (*1).
Do not move or repair any unit by yourself. Since there is high voltage
inside the unit, you may get electric shock when removing the cover
and main unit.
5-EN 6-EN
–4–
• Use of a stand more than 50 cm high to clean the filter of the indoor
unit or to carry out other such jobs constitutes working at heights. Due
to the danger of falling off the stand and injuring yourself while
working at heights, this kind of work should not be done by unqualified
individuals. When this kind of work must be carried out, do not do it
yourself but ask a qualified installer or a qualified service person to do
it for you.
• Do not touch the aluminum fin of the outdoor unit. You may injure
yourself if you do so. If the fin must be touched, do not touch it
yourself but contact a qualified installer or a qualified service person.
Do not climb onto or place objects on top of the outdoor unit. You may
fall or the objects may fall off of the outdoor unit and result in injury.
• Do not place any combustion appliance in a place where it is directly
exposed to the wind of air conditioner, otherwise it may cause
imperfect combustion.
• When the air conditioner is operated with a combustion appliance in
the same place, ventilate the room sufficiently. Poor ventilation
causes oxygen shortage.
• When the air conditioner is used in a closed room, sufficiently
ventilate the room. Poor ventilation causes oxygen shortage.
Do not expose your body to cool air directly for a long time and do not
cool yourself excessively. Doing so may result in deteriorated
physical condition and ill health.
• Do not insert your finger or a stick into the air intake or discharge.
Doing so may result injury as the fan is rotating at high speed inside
the unit.
• Consult the shop where you purchased the air conditioner if air
conditioning (cooling and heating) is not performed properly as a
refrigerant leakage may be the cause. Confirm the repair details with
a Qualified service person (*1) when the repair includes additional
charging of the refrigerant.
• Stop running the air conditioner and turn off the breaker before
cleaning. Otherwise, injury may result as the fan is rotating at high
speed inside the unit.
Repairs
• When you have noticed that some kind of trouble (such as when a
check display has appeared, there is a smell of burning, abnormal
sounds are heard, the air conditioner fails to cool or heat or water is
leaking) has occurred in the air conditioner, do not touch the air
conditioner yourself but set the circuit breaker to the OFF position,
and contact a qualified service person. Take steps to ensure that the
power will not be turned on (by marking “out of service” near the
circuit breaker, for instance) until qualified service person arrives.
Continuing to use the air conditioner in the abnormal status may
cause mechanical problems to escalate or result in electric shocks,
etc.
• If the fan grille is damaged, do not approach the outdoor unit but set
the circuit breaker to the OFF position, and contact a Qualified service
person (*1) to have the repairs done. Do not set the circuit breaker to
the ON position until the repairs are completed.
• If you have discovered that there is a danger of the indoor unit’s
falling, do not approach the indoor unit but set the circuit breaker to
the OFF position, and contact a Qualified installer (*1) or a Qualified
service person (*1) to refit the unit. Do not set the circuit breaker to
the ON position until the unit has been refitted.
• If there is a danger of the outdoor unit’s toppling over, do not
approach the outdoor unit but set the circuit breaker to the OFF
position, and contact a Qualified installer (*1) or a Qualified service
person (*1) to have the improvements or refitting done. Do not set the
circuit breaker to the ON position until the improvements or refitting is
completed.
• Do not customize the unit. Doing so may result in fire, electric shock
or other trouble.
Relocation
When the air conditioner is to be relocated, do not relocate it yourself
but contact a Qualified installer (*1) or a Qualified service person (*1).
Failure to relocate the air conditioner properly may result in electric
shocks and/or a fire.
(*1) Refer to the “Definition of Qualified Installer or Qualified Service Person”.
7-EN 8-EN
–5–
Installation
• Certainly lay the drain hose for perfect draining. Improper drainage
may cause flooding in the house and getting furniture wet.
Connect the air conditioner to an exclusive power supply of the rated
voltage, otherwise the unit may break down or cause a fire.
Confirm that the outdoor unit are fixed on the base. Otherwise, falling
down of the units or other accidents may occur.
Do not install the air conditioner in place where steam is generated,or
in place near the humidifier etc. Dew may form in the parts built in the
unit, causing trouble of the unit.
Operation
Do not use this air conditioner for special purpose such as preserving
food, precision instruments, art objects, breeding animals, car,
vessel.
• Do not touch any switches with wet finger, otherwise you may get an
electric shock.
If the air conditioner will not be used for a considerably long time, turn
off the main switch or the circuit breaker, for safety.
• To make the air conditioner operate in its original performance,
operate it within the range of the operating temperature specified in
the instructions. Otherwise it may cause a malfunction, or water leak
from the unit.
• Prevent any liquid from falling into the remote controller. Do not spill
juice, water or any kind of liquid.
Do not wash the air conditioner. Doing so may result in electric shock.
• Check whether the installation base and other equipment have
become deteriorated after being used for a long time. Leaving them
such condition may result in the unit’s falling down and causing injury.
Do not leave flammable sprays or other flammable materials near the
air conditioner, and do not spray flammable aerosol directly to the air
conditioner. They may catch fire.
• Stop running the air conditioner and turn off the breaker before
cleaning.
Otherwise, injury may result as the fan is rotating at high speed inside
the unit.
CAUTION
• Ask for cleaning of the air conditioner to be performed by the dealer.
Cleaning the air conditioner in an improper manner may cause
damage to plastic parts, insulation failure of electric parts or other
parts, and result in a malfunction. In the worst case, it may result in
water leakage, electric shock, smoke emission or fire.
9-EN 10-EN
–6–
Information on the transportation, handling and storage of the
carton
Examples of indication on the carton
Symbol Description Symbol Description
Keep dry Do not drop
Fragile Do not lay down
Stacking height
(12 cartons can be stacked in
this case)
Do not step
This side up Do not drop (corner)
Handle with care Do not roll
Other cautions Description
CAUTION
Injury possibility.
Don’t handle with packing band, or may get injured in case of broken
band.
Stacking notice.
In case that cardboard boxes protrude out of pallet when stacking.
Lay a 10 mm thick plywood over the pallet.
11 cartons
2Part names
Indoor unit
Horizontal louver / Vertical
grille / Air discharge
The air discharge direction can be
changed.
Air intake grille
Air is taken in through here.
Air filter
Filters out dust.
(Behind the air intake grille)
Earth screw
Inside the electrical box.
11-EN 12-EN
–7–
3Part names and functions of the remote
controller
Remote controller model name: RBC-ASCU1
LCD back-light lights for 15 seconds during remote controller operation.
All indicators are displayed in the display example below.
Actually, only the selected options will be displayed.
Operations
1ON/OFF button
Turns on the unit when pushed, and turns off when pushed again.
2Setting button
Sets setting temperature at the normal mode.
Changes each setting at the Operation mode, the Fan speed mode or the Wind direction mode.
3OFF timer button
Setting the OFF timer.
4Menu button
Selects the Operation mode select, the Fan speed select or the Wind direction select.
Each time you push the button, indicator is displayed as followings.
The Fan speed select or the Wind direction select is not displayed depending on indoor unit models.
1234
Operation lamp
Lights during operations.
Blinks when a check occurs or the
protective device activates.
Normal operation
mode
Operation mode
select Fan speed select Wind direction
select
Indicators
All icons on the display are shown for this explanation. Operations are not accepted when “SETTING” is flashing.
1Operation mode indicator
Indicates the operation mode selected.
2Central control indicator
Displayed when the air conditioner is controlled
centrally and used with central control devices
such as the central remote controller.
If the use of the remote controller is prohibited by
the central control, blinks when the ON/OFF,
MODE, or TEMP. button on the remote controller
is pushed, and the buttons do not function.
(Settings that can be configured on the remote
controller differ depending on the mode of the
central control. For details, read the Owner’s
Manual of the central remote controller.)
3Setting indicator
Indicates that the model is being checked
automatically after a breaker is thrown or some
other occurrence.
4Service indicator
Displayed while the protective device works or a
check occurs.
5Test run indicator
Displayed during test run.
6Temperature setting indicator
The selected set temperature is displayed.
7Swing indicator
Displayed during up/down movement of the
louver.
8Louver position indicator
Indicates the louver position.
9Louver lock indicator
Displayed when there is a louver-locked unit.
10
Fan speed indicator
Indicates the selected fan speed
11
OFF timer indicator
When a trouble occurs, a check code is displayed.
12
Pre-heat indicator
Displayed when the heating mode is energized or
defrost cycle is initiated.
While this indication is displayed, the indoor fan
stops or operate in fan mode.
13
Remote controller sensor indicator
Displayed while the sensor of the remote controller
is used.
14
Notice display
Displayed while notice code occurs.
For details, contact your dealer (distributor).
15
No function display
Displayed when the function requested is not
available on that model.
2
34
5
6
10
14
11
12
15
7
81
9
13
Auto
Low
Low +
Medium
Medium +
High
Fix
13-EN 14-EN
–8–
4Operation
When you use the air conditioner for the first time or change the settings, follow the procedures below. From next
time, pushing the ON/OFF button starts running of the air conditioner with the chosen settings.
Standby
Operations are not accepted when “SETTING” is blinking.
REQUIREMENT
Keep the power switch turned on during use.
When you resume using the air conditioner after a long period of disuse, turn on the power switch at least 12 hours
before starting running.
When the power is turned on, it takes about 1 minute before the remote controller becomes operable.
This is not a malfunction.
Running operation
Some operation modes are not available depending on the type of indoor unit.
1ON/OFF button
Push this button to light the operation lamp and
start operations.
When heating
The heated air comes out after a 3 to 5 minutes
of pre-heating with the indoor fan kept turned
off.
2Select the operation mode
Push the Menu button several times to select the
operation mode.
The current operation mode flashes.
Each time you push the setting button, the
operation mode and its icon change in the
following order:
If you do not push any button for 30s, the
operation mode finishes.
3Select the fan speed
Push the Menu button several times to select the
fan speed mode.
The current fan speed indicator flashes.
Each time you push the setting button, the fan
speed mode and its indication change in the
following order:
A selectable fan speed differs depending on
indoor units to be connected.
Auto” cannot be selected at the Fan
mode.
If you do not push any button for 30s, the fan
speed mode finishes.
4Select the temperature
Push the setting button to adjust the temperature.
The temperature setting range is 18.0°C to
29.0°C.
The temperature can be set in steps of 0.5°C.
Menu button Setting button ON/OFF button
Heat Dry Cool Fan
(Dehumidify)
Auto
NOTE
Auto Changeover
When in Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point
temperature.
If the Auto mode is uncomfortable, you can select the desired conditions manually.
Cooling
If there is a demand for cooling, unit will start approximately 1 minute after mode is selected.
When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at extremely
low speed.
Heating
If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.
After the heating operation has stopped, fan may continue to run for approx. 30 seconds.
When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at extremely
low speed.
During defrost operation, the fan stops so that cool air is not discharged. (“ ” Pre-heat is displayed.)
When restarting the operation after stop
When the unit is attempted to restart immediately after it was stopped, the unit can not start for approx. 3 minutes this is to
protect the compressor.
8°C Operation (For object pre-heating)
The air conditioner can control the heating temperature to about 8°C in the heating mode.
The 8°C heating operation requires settings with the wired remote controller. Ask the installer or dealer for the settings
according to the installation manual of the indoor unit.
Start
1Set the displayed temperature to 18°C in the heating mode by pushing [ ] setting button.
2Set the displayed temperature to 8°C by pushing [ ] setting button for at least four seconds.
Stop
1Set the displayed temperature to 18°C by pushing [ ] setting button.
The air conditioner returns to the normal Heat mode. Select a desired temperature and operation mode.
NOTE
The discharged air temperature is lower than that in the normal heating operation.
The room temperature may not be heated evenly depending on the remote controller installation location.
The room temperature may not reach 8°C depending on the room size or the installation conditions.
Setting for fan speed is available during the 8°C heating operation.
The 8°C heating operation is cancelled in the following cases.
•When operation is stopped with ON/OFF button.
•When another operation mode is selected.
•When temperature setting or operation mode is changed or operation is started / stopped by the wireless remote controller
or the central control remote controller.
When this operation mode is used, observe proper operating hours and periodic maintenance by service staff is
recommended.
15-EN 16-EN
–9–
5OFF timer operation
OFF timer: The indoor unit stops when the set time is reached.
1OFF timer button
Push the OFF timer button during air conditioning operation.
” and “OFF” light and “SETTING” and timer indicator flash.
2Select the OFF timer time
Push the setting button to set the time.
The OFF timer time can be set to 0.5 h (30 min), 1 h, 2 h, up to 24 h.
If you do not push any button for 30s, the OFF timer setting will be cancelled.
3Push the OFF timer button
“SETTING” disappears, the timer indicator changes from flashing to lighting, and the OFF timer starts.
The timer indicator on the OFF timer operation is displayed with countdown.
Cancelling the timer
1Push the OFF timer button
The timer indicator disappears.
NOTE
Even if air conditioning is turned on or off with the ON/OFF button during OFF timer operation, the OFF timer operation
continues.
6Adjustment of wind direction
To improve the cooling / heating performance,
change the louver angle for each operation.
Air characteristics: Cool air falls, and warm air
rises.
CAUTIONCAUTION
Point the louver horizontally during cooling
If pointing downward for cooling, dew may form on the
surface of the air discharge or louver and may drop
down.
NOTE
If pointing horizontally for heating, the room
temperature may be uneven.
Do not handle the louver manually. Doing so may
cause a failure. Use the remote controller to adjust the
angle.
To set the louver direction and auto swing
1Push the Menu button several times and select
the wind direction mode to blink the wind
direction.
2Push the setting button several times to display
the louver direction as shown in the figure
below.
If you do not push any button for 30s, the wind
direction mode finishes.
For heating
The louver can be adjusted to six steps.
Point the louver downward. If not pointing downward,
hot air may not reach the floor.
For cooling
The louver can be adjusted to four steps.
Point the louver horizontally. If pointing downward, dew
may form on the surface of the air discharge port and
may drop down.
If a louver lock setup is carried out in the position of (1),
fan speed will be restricted for prevention of ceiling
contamination.
For fan
The louver can be adjusted to six steps.
Select a wind direction.
Auto swing
The SWING indicator is displayed and the louver
begins swinging.
Initial (1) (2) (3) (4) (5) (6)
Operation mode Available directions
HEAT, FAN (1) (2) (3) (4) (5) (6)
(Swing)
Initial (1) (2) (3) (4)
Operation mode Available directions
COOL, DRY (1) (2) (3) (4)
(Swing)
Repeat
17-EN 18-EN
–10–
When cooling
Point the louver horizontally.
When heating
Point the louver downward.
The louver automatically closes when running is
stopped.
In pre-heating mode, the louver points upward.
The swing indication appears on the remote
controller even in pre-heating mode, but the actual
swing starts only after pre-heating is complete.
NOTE
When stopped, the louver closes automatically.
The louver automatically becomes horizontal or closed at the start of heating operation, defrosting operation, or when
the set temperature becomes the same as room temperature. If you set the swing or wind direction at this time, the
remote controller display will be the setting, but the louver will not move. When the normal heating operation that
blows warm air is started, the louver will be in the set wind direction.
When the defrosting operation is performed during heating, the louver automatically closes to reduce the cold air
falling from the indoor unit.
If the heating operation is performed less than 12 hours after the circuit breaker is turned on when the outside
temperature is low, the louver may automatically close immediately after the start of heating operation to reduce the
loss of cold air.
Information
The following functions require a connection with the RBC-AMTU*** and
RBC-AMSU*** remote controller. For details, consult the dealer where you
purchased this product.
Individual unit selection during group operation
Individual setting of louver position (wind direction)
Swing type setting
Louver lock (no swing) setting
7Maintenance
WARNING
Cleaning the air filter and other parts of the air filter involves dangerous work in high places, so be sure
to have a qualified installer or qualified service person to do it.
Do not attempt it by yourself.
CAUTIONCAUTION
Do not push buttons with wet hands.
Doing so may result in electric shock.
Cleaning the air filters
When the filter indicator is displayed on the remote controller, clean the air filters.
(Only for RBC-AMTU*** and RBC-AMSU*** remote controllers.)
Clogged filters may lower the cooling and heating performance.
When the unit will not be used for a long time
1. Perform the fan operation for a couple of hours to dry inside.
2. Stop the air conditioner with the remote controller and turn off the circuit breaker.
3. Clean the air filters and reinstall them.
Before the cooling season
Clean the drain pan
Contact the dealer where you purchased the product.
(Drain does not work if the drain pan or vent is clogged. In some cases the drain may overflow and wet the wall or floor. Be
sure to clean the drain pan before the cooling season.)
19-EN 20-EN
–11–
Check periodically
If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified water
depending on the heat, humidity, or dust.
In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the dealer where
you purchased it.
NOTE
For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in
use be cleaned and maintained regularly to ensure efficient operation of the air conditioner.
When the air conditioner is operated for a long time, periodic maintenance (once a year) is recommended.
Furthermore, regularly check the outdoor unit for rust and scratches, and remove them or apply rustproof treatment, if
necessary.
As a general rule, when an indoor unit is operated for 8 hours or more daily, clean the indoor unit and outdoor unit at
least once every 3 months. Ask a professional for this cleaning / maintenance work.
Such maintenance can extend the life of the product though it involves the owner’s expense.
Failure to clean the indoor and outdoor units regularly will result in poor performance, freezing, water leakage, and even
compressor failure.
Maintenance List
Part Unit Check (visual / auditory) Maintenance
Heat exchanger Indoor / outdoor Dust / dirt clogging, scratches Wash the heat exchanger when it is clogged.
Fan motor Indoor / outdoor Sound Take appropriate measures when abnormal sound
is generated.
Filter Indoor Dust / dirt, breakage Wash the filter with water when it is contaminated.
Replace it when it is damaged.
Fan Indoor
Vibration, balance
Dust / dirt, appearance
Replace the fan when vibration or balance is
terrible.
Brush or wash the fan when it is contaminated.
Air intake / discharge
grilles Indoor / outdoor Dust / dirt, scratches Fix or replace them when they are deformed or
damaged.
Drain pan Indoor Dust / dirt clogging, drain
contamination
Clean the drain pan and check the downward slope
for smooth drainage.
Ceiling panel,
louvers Indoor Dust / dirt, scratches Wash them when they are contaminated or apply
repair coating.
Exterior Outdoor Rust, peeling of insulator
Peeling / lift of coat Apply repair coating.
8Troubleshooting
Check the points described below before requesting repair.
If there is something unusual even after checking the above, stop running the unit, turn off the circuit breaker, and inform the
dealer where you purchased the product of the product number and symptom. Do not attempt to repair the unit by yourself as
doing so is dangerous. If the check indicator ( , , , etc.) is displayed on the remote controller LCD, inform the dealer
of its content as well.
If any of the following occur, stop running the unit immediately, turn off the circuit breaker, and contact the dealer where you
purchased the product.
The switch does not work properly.
The circuit breaker often blows out.
You unintentionally put a foreign object or water inside.
The unit cannot be run even after the cause of the protective device activation is removed.
Other unusual conditions are found.
Symptom Cause
It is not a malfunction.
Outdoor unit
White, misty, cold air or water comes out
Sometimes the noise of air leaking is heard.
A noise is heard when the power is turned
on.
The fan of the outdoor unit is automatically stopped and
defrosting is performed.
The solenoid valve works when defrosting starts or stops.
The outdoor unit is preparing for running.
Indoor unit
Sometimes a swishing is heard.
A clacking sound is heard.
Discharged air smells unusual.
Louvers close automatically during heating
When the unit starts running, during operation, or
immediately after the unit stops running, a sound such as
water flowing may be heard, or the operation sound may
become louder for a couple of minutes immediately after
the unit starts running. This is the sound of the refrigerant
flowing or the dehumidifier draining.
This is a sound generated when the heat exchanger, etc.
expands and contracts slightly due to temperature
change.
Various smells from the walls, carpet, clothes, cigarette,
cosmetics, etc. adhere to the air conditioner.
In the following cases, the louvers close automatically to
reduce the cold air falling from the indoor unit.
When defrosting during heating operation.
Immediately after starting heating operation less than 12
hours after turning on the circuit breaker when the outside
temperature is low.
Check again.
The unit does not run
Has a blackout occurred?
Has the circuit breaker blown?
Has the protective device been activated? (The operation
indicator and on the remote controller are blinking.)
The room does not cool down or warm up.
Is the air intake or discharge of the outdoor unit clogged?
Is a door or window open?
Is the air filter clogged with dust?
Is the air volume set to “Low”? Or is the operation mode
set to “Fan”?
Is the setup temperature appropriate?
21-EN 22-EN
–12–
Confirmation and check
Troubleshooting history and confirmation
You can check the troubleshooting history with the following procedure if a problem occurs with the air conditioner.
(The troubleshooting history records up to 4 incidents.)
You can check it during operation or when operation is stopped.
If you check the troubleshooting history during OFF timer operation, the OFF timer will be cancelled.
If a problem occurs with the air
conditioner, the OFF timer indicator
alternately shows the check code and
the indoor Unit No. in which the
problem occurred.
Procedure Description of operation
1
Push the OFF timer button for over 10 seconds and the
indicators appear as an image indicating the
troubleshooting history mode has been entered. If
[ Service check] is displayed, the mode enters in the
troubleshooting history mode.
[01: Order of troubleshooting history] appears in the
temperature indicator.
The OFF timer indicator alternately shows the [check
code] and the [indoor Unit No.] in which the problem
occurred.
2
Each time the setting button is pushed, the recorded
troubleshooting history is displayed in sequence.
The troubleshooting history appears in order from [01]
(newest) to [04] (oldest).
CAUTIONCAUTION
In the troubleshooting history mode, DO NOT push the
Menu button for over 10 seconds, doing so deletes the
entire troubleshooting history of the indoor unit.
3
After you have finished checking, push the ON/OFF button
to return to the regular mode.
If the air conditioner is operating, it remains operated
even after the ON/OFF button has been pushed.
To stop its operation, push the ON/OFF button again.
Check code The indoor Unit No. in which
the problem occurred.
312
9Operations and performance
Check before running
Check whether the earth wire is cut or disconnected.
Check whether the air filter is installed.
Turn on the circuit breaker 12 hours or more before starting
operation.
3 minutes protection function
3-minutes protection function prevents the air conditioner
from starting for initial 3 minutes after the main power switch
/ circuit breaker is turned on for re-starting the air conditioner.
Power failure
Power failure during operation will stop the unit completely.
To restart the operation, push the ON / OFF button on the
remote controller.
Lightning or a wireless car telephone operating nearby
may cause the unit to malfunction. Turn off the main power
switch or circuit breaker and then turn them on again. Push
the ON / OFF button on the remote controller to restart.
Defrosting operation
If the outdoor unit is frosted during the heating operation,
defrosting starts automatically (for approximately 2 to 10
minutes) to maintain the heating capacity.
The fans in both indoor and outdoor units will stop during
the defrosting operation.
During the defrosting operation, the fan of the indoor unit /
outdoor unit stops and the louver of the indoor unit closes.
During the defrosting operation, the defrosted water will be
drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, the heat is absorbed from the
outside and brought into the room. This way of heating is
called heat pump system. When the outside temperature is
too low, it is recommended to use another heating apparatus
in combination with the air conditioner.
Protective device
Stops operation when the air-conditioner is overloaded.
If the protective device is activated, the unit stops running,
and the operation indicator and check indicator on the
remote controller blink.
If the protective device is activated
Turn off the circuit breaker and perform a checkup.
Continued running may cause a malfunction.
Check whether the air filter is installed. If not, the heat
exchanger may be clogged with dust and water leakage
may occur.
During cooling
The air intake or discharge of the outdoor unit is
clogged.
Strong wind continuously blows against the discharge of
the outdoor unit.
During heating
The air filter is clogged with a large amount of dust.
The air intake or discharge of the indoor unit is clogged.
Do not turn off the circuit breaker
During the air-conditioning season, leave the circuit
breaker turned on, and use the ON / OFF key on the
remote controller.
Attention to snowfall and freeze on the
outdoor unit
In snowy areas, the air intake and air discharge of the
outdoor unit are often covered with snow or frozen up.
If snow or freeze on the outdoor unit is left as it is, it may
cause machine failure or poor warming.
In cold areas, pay attention to the drain hose so that it
perfectly drains water without water remaining inside for
freeze prevention. If water freezes in the drain hose or
inside the outdoor unit, it may cause machine failure or
poor warming.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions:
Refer to the combined outdoor unit installation manual for details about the outdoor temperature.
If air conditioner is used outside of the above conditions, safety protection may work.
Cooling operation
Room temperature : 21°C to 32°C (Dry bulb temp.), 15°C to 28°C (Wet bulb temp.)
[CAUTION] Room relative humidity – less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may cause dewing.
Heating operation Room temperature : 15°C to 28°C (Dry bulb temp.)
23-EN 24-EN
–13–
10 Installation
Do not install the air conditioner in the following places
Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. If the unit is installed in such place,
noise transmitted from the air conditioner affects the operation of these appliances.
Do not install the air conditioner near a high frequency appliance (sewing machine or massager for business use, etc.),
otherwise the air conditioner may malfunction.
Do not install the air conditioner in a humid or oily place, or in a place where steam, soot, or corrosive gas is generated.
Do not install the air conditioner in a salty place such as seaside area.
Do not install the air conditioner in a place where a great deal of machine oil is used.
Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside area.
Do not install the air conditioner in a place where sulfurous gas generated such as in a spa.
Do not install the air conditioner in a vessel or mobile crane.
Do not install the air conditioner in an acidic or alkaline atmosphere (in a hot-spring area or near a chemicals factory, or in a
place subject to combustion emissions). Corrosion may be generated on the aluminum fin and copper pipe of the heat
exchanger.
Do not install the air conditioner near an obstacle (air vent, lighting equipment, etc.) that disturbs discharge air. (Turbulent
airflow may reduce the performance or disable devices.)
Do not use the air conditioner for special purposes such as preserving food, precision instruments, or art objects, or where
breeding animals or growing plants are kept.
(This may degrade the quality of preserved materials.)
Do not install the air conditioner over an object that must not get wet. (Condensation may drop from the indoor unit at a
humidity of 80% or more or when the drain port is clogged.)
Do not install the air conditioner in a place where an organic solvent is used.
Do not install the air conditioner near a door or window subject to humid outside air.
Condensation may form on the air conditioner.
Do not install the air conditioner in a place where special spray is used frequently.
Be careful with noise or vibrations
Do not install the air conditioner in a place where noise by outdoor unit or hot air from its air discharge annoys your neighbors.
Install the air conditioner on a solid and stable foundation so that it prevents transmission of resonating, operation noise and
vibration.
If one indoor unit is operating, some sound may be audible from other indoor units that are not operating.
11 Specifications
* Under 70 dB(A)
Model Sound pressure level (dB(A)) Weight (Kg)
Main unit (Ceiling panel)
Cooling Heating
RAV-HM301MUT-E * * 15 (2.5)
RAV-HM401MUT-E * * 15 (2.5)
RAV-HM561MUT-E * * 15 (2.5)
Product information of ecodesign requirements. (Regulation (EU) 2016/2281)
http://ecodesign.toshiba-airconditioning.eu/en
25-EN 26-EN
–14–
Declaration of Conformity
NOTE
This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer’s
consent.
Manufacturer: TOSHIBA CARRIER CORPORATION
336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN
TCF holder: TOSHIBA CARRIER EUROPE S.A.S
Route de Thil
01120 Montluel FRANCE
Hereby declares that the machinery described below:
Generic Denomination: Air Conditioner
Model / type: RAV-HM301MUT-E
RAV-HM401MUT-E
RAV-HM561MUT-E
Commercial name: Super Digital Inverter Series Air Conditioner
Complies with the provisions of the “Machinery Directive 2006 / 42 / EC” and the regulations transposing into
national law
Name: Sato Kazuhisa
Position: Senior Manager
Quality Assurance & Service Engineering Dept.
Date: 07 April, 2022
Place Issued: Japan
Declaration of Conformity
NOTE
This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer’s
consent.
Manufacturer: TOSHIBA CARRIER CORPORATION
336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN
TCF holder: TOSHIBA CARRIER UK LTD.
Porsham Close Belliver Industrial Estate Roborough Plymouth Devon
PL6 7DB United Kingdom
Hereby declares that the machinery described below:
Generic Denomination: Air Conditioner
Model / type: RAV-HM301MUT-E
RAV-HM401MUT-E
RAV-HM561MUT-E
Commercial name: Super Digital Inverter Series Air Conditioner
Complies with the provisions of the Supply of Machinery (Safety) Regulations 2008
Name: Sato Kazuhisa
Position: Senior Manager
Quality Assurance & Service Engineering Dept.
Date: 07 April, 2022
Place Issued: Japan
27-EN 28-EN
EH99971001
(DH91308201)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Toshiba RAV-HM301MUT-E Owner's manual

Category
Split-system air conditioners
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI