RISC GROUP RP432KP LCD Keypad and LCD Proximity Keypad User guide

Type
User guide
LCD Keypad &
LCD Proximity Keypad
(Models: RP432KP, RP432KPP)
2
Installing the LightSYS Keypad
Main Panel Back Side
2
1
4 5
6
3
3
Introduction
The user-friendly LightSYS LCD/LCD Proximity keypad enables simple operation and
programming of the LightSYS and ProSYS security systems.
The following instructions offer a brief keypad operation overview. For detailed
information on programming the system, refer to the LightSYS or ProSYS Installer and
User manuals.
Indicators
Power
On
System is operating properly from
AC power, its backup battery is in
good condition and there are no
troubles in the system.
Off No power.
Slow Flash System is in programming.
Rapid Flash System trouble (fault).
Ready
On System is ready to be armed.
Off System is not ready to be armed
Slow Flash System is ready to be armed (set)
while exit/entry zone is open.
Arm (Set)
On System is armed in Full Arm or Stay
Arm (Part Set) mode.
Off System is disarmed (unset).
Slow Flash System is in Exit Delay.
Rapid Flash Alarm condition.
Stay / Bypass
(Part Set/ Omit)
On System is in Stay Arm (Part Set) or
Zone Bypass (omit) mode.
Off No bypass zones in system.
Tamper
On Zone/keypad/external module has
been tampered.
Off All zones are operating normally.
Fire
On Fire alarm.
Off Normal operation.
Flashing Fire circuit problem.
LED (Red)
Arm / Alarm Behaves in the same manner as the indicator.
4
Keys
Control Keys
In Normal Operation mode: Used for Away (Full setting).
In User Functions menu: Used to change data.
In Normal Operation mode: Used for Stay arming (Part
Setting).
In User Functions menu: Used to change data.
Used to disarm (unset) the system after a user code is
entered;
/ OK is used to terminate commands and confirm data to be
stored.
Note:
The key is equivalent to the key on ProSYS
keypads.
Used to scroll up a list or to move the cursor to the left ;
Provides the system status.
Used to scroll down a list or to move the cursor to the
right.
Note:
The icon is equivalent to the icon on ProSYS
keypads.
In Normal Operation mode: Used to enter the User Functions
menu.
In User Functions menu: Used to move back one step in the
menu.
Emergency Keys
Pressing both keys simultaneously for at least two seconds
activates a Fire alarm.
Pressing both keys simultaneously for at least two
seconds activates an Emergency alarm.
Pressing both keys simultaneously for at least two seconds
activates a Police (Panic) alarm.
5
Function Keys
Used to arm (set) groups of zones (by default) or to
activate a prerecorded series of commands (macros).
To activate press for 2 seconds.
Numeric Keys
Used to input numbers when required.
Keypad Settings
Note:
The following settings must be defined individually for each keypad connected to the system.
To define keypad settings, follow this procedure:
1. Press for two seconds until the Keypad Settings menu appears.
2. Select the relevant icon using the and keys. To enter option, press:
Brightness
Contrast
Keypad's buzzer volume
Language (ProSYS mode only)
Note:
The LightSyS Language option can always be accessed by simultaneously
pressing and .
For ProSYS versions prior to 5, set the keypad language according to the panel
language.
Panel RP432/RP128 (ProSYS)
Note:
Select RP432 when the keypad is connected to the LightSYS (default) or RP128
when the keypad is connected to ProSYS.
6
3. Adjust settings with arrow keys. Confirm adjusted settings with .
4. Press to save the adjusted settings.
5. Press to exit the keypad settings menu.
Using the Proximity Tag
The proximity tag, used with the proximity LCD keypad (RP432
KPP) is correctly used by applying it within a 4 cm distance from
the front of the keypad bottom, as shown at right.
Automatic Upgrade Resulting from Panel Manual Upgrade
Upon initiation of the LightSYS panel remote upgrade (See LightSYS Installer Manual,
Appendix I: Remote Software Upgrade), the keypad software may automatically also be
upgraded. During this approximately three-minute process an upgrade icon ( ) and
the power icon ( ) are displayed on the keypad and the LED light flashes. Do not
disconnect during this period
Technical Specifications
Current consumption
RP432 KP
RP432 KPP
13.8V +/-10%, 48 mA typical/52 mA max.
13.8V +/-10%, 62 mA typical/130 mA max.
Main panel connection 4-wire BUS, up to 300 m (1000 ft) from Main Panel
Dimensions 153 x 84 x 28 mm (6.02 x 3.3 x 1.1 inch)
Operating temperature -10°C to 55°C (14°F to 131°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
Prox. RF frequency 13.56MHz
Complies with EN 50131-3 Grade 2 Class II
Ordering Information
Model Description
RP432 KP LightSYS LCD Keypad
RP432 KPP LightSYS LCD Keypad with Proximity 13.56MHz
RP200KT 10 prox keytags (13.56MHz)
7
FCC Note
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference and
2. This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: JE4RP432KPP
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
a. Reorient or relocate the receiving antenna.
b. Increase the separation between the equipment and receiver.
c. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
d. Consult the dealer or an experienced radio/TV technician.
FCC Warning
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
Such modifications could void the user's authority to operate the equipment.
RTTE Compliance Statement
Hereby, RISCO Group declares that this equipment is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC. For the EC Declaration of Conformity please refer to our
website: www.riscogroup.com.
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and
workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product
and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot guarantee the
performance of the security system which uses this product. Seller's obligation and liability under this warranty is expressly
limited to repairing and replacing, at Seller's option, within a reasonable time after the date of delivery, any product not meeting
the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness
for any particular purpose.
In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or
implied, or upon any other basis of liability whatsoever.
Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct,
indirect, or consequential damages or delay.
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any personal
injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or
protection.
Seller, in no event shall be liable for any direct or indirect damages or any other losses occurred due to any type of tampering,
whether intentional or unintentional such as masking, painting or spraying on the lenses, mirrors or any other part of the detector.
Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without
warning, but is not insurance or a guaranty that such event will not occur or that there will be no personal injury or property loss
as a result thereof.
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails
to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising under this limited
warranty or otherwise, regardless of cause or origin, seller's maximum liability shall not exceed the purchase price of the product,
which shall be complete and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.
8
Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can
contact us through our website www.riscogroup.com or as follows:
United Kingdom
Tel: +44-(0)-161-655-5500
E-mail: support-uk@riscogroup.com
France
Tel: +33-164-73-28-50
E-mail: support-fr@riscogroup.com
Italy
Tel: +39-02-66590054
E-mail: support-it@riscogroup.com
Spain
Tel: +34-91-490-2133
E-mail: support-es@riscogroup.com
Belgium (Benelux)
Tel: +32-2522-7622
E-mail: support-be@riscogroup.com
USA
Tel: +1-631-719-4400
E-mail: support-usa@riscogroup.com
China (Shanghai)
Tel: +86-21-52-39-0066
E-mail: support-cn@riscogroup.com
Israel
Tel: +972-3-963-7777
E-mail: support@riscogroup.com
RISCO product was purchased from
All rights reserved.
No part of this document may be reproduced in any form without prior written
permission from the publisher.
© RISCO Group 03/2015 5IN1425 G
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

RISC GROUP RP432KP LCD Keypad and LCD Proximity Keypad User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI