Conditions for warranty, guarantee, liability
Conditions for warranty, guarantee, liability
We can only guarantee and accept liability for the
function of our boiler if it is properly installed and
operated.
Requirement for warranty, guarantee and liability
is that this boiler be used in accordance with its
intended purpose, only for heating and hot
water supply with no more than 2,000 full-
load hours annually, and, in particular, that the
following general conditions be observed during
installation and operation:
For set-up, a dry room is required. In particular,
only condensation dryers may be used as clothes
dryers in the same room.
Local building and fire protection regulations must
be observed.
The log wood boiler is suitable for use with
air-dried split logs with no more than 20%
water content and wood briquettes. Use with
unsuitable fuels, especially refuse, coal and coke,
and also wet wood, is not permitted.
The combustion air must be free of aggressive
substances such as chlorine and fluorine
from solvents, cleaning agents, adhesives and
propellants, or ammonia from cleaning agents,
to prevent corrosion of the boiler and chimney.
Water is the intended heat-transfer medium. For
special anti-frost requirements, up to 30% glycol
may be added. Softened water is required for
the initial fill-up of the heating system and for
refilling after repairs. For the initial fill-up, the
value of 20,000 lt°dH for the system volume in
litres multiplied by the hardness (in degrees of
German hardness) may not be exceeded. The
pH value should be set between 8 and 9.
Addition of hard water should be minimised to
limit limescale build-up in the boiler. Set enough
shut-off valves to avoid bleeding large amounts of
water during repairs. Any leaks in the system must
be repaired at once.
Ensure a minimum return temperature of 60°C
to the boiler.
A safety valve (3 bar) as protection against excess
pressure and a thermal relief valve (95°C) to
protect against overheating must be installed by
the contractor.
To protect against air suction if the system cools
off, an expert must provide a sufficiently large
expansion tank or a pressure maintenance
system. Sufficient air venting must also be
ensured. Open expansion tanks or underfloor
heating with permeable piping also have a
high air intake, resulting in above-average boiler
corrosion. Corrosion damage to the boiler due to
improper air venting or high air intake is excluded
from warranty, guarantee and liability.
Operation at lower power than the lowest power
specified on the type plate is not permitted.
Only components provided by us may be used
for expansion of the control system, except for
commonly used units such as thermostats.
Cleaning and maintenance are required as
specified in the user manual.
Repairs are only permitted with spare parts
provided by us. The only exceptions are common
standardised parts such as electrical fuses or
fastening materials, as long as they possess
the required features and do not restrict the
functionality of the system.