De Dietrich KALIKO TWH Split FS 200 E User manual

Category
Heat pumps
Type
User manual

This manual is also suitable for

EASYLIFE
S U S T A I N A B L E C O M F O R T
®
KALIKO SPLIT
MW-1000590-4
en
User Guide
Thermodynamic water heater
KALIKO SPLIT
TWH Split FS 200 E
TWH Split FS 270 E
Serv. ref. SODU 2 M R1
Dear Customer,
Thank you very much for buying this appliance.
Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to
ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer
service organisation can assist with this.
We hope you enjoy years of problem-free operation with the product.
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3 Specific safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4 Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4.1 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
1.4.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4.3 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.5 Safety data sheet: refrigerant fluid R-134a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.5.1 Product identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.5.2 Hazard identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.5.3 Composition of/Information on the ingredients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.5.4 First aid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.5.5 Fire prevention measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.5.6 In the event of accidental spillage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.5.7 Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
1.5.8 Personal protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.5.9 Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.1 Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.1 Symbols used in the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.2 Symbols used on the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1 Homologations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1.1 Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1.2 2014/68/UE Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.1.3 Ecodesign Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1.4 Factory test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.2.1 Technical data - Heat pump water heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.2 Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2.1 Thermodynamic water heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2.2 Operating principle for the thermodynamic water heater with outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2.3 Operation of various MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2.4 Limit temperatures of the thermodynamic water heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.3 Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.3.1 Domestic hot water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.3.2 Outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
4.4 Control panel description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.4.1 Description of the control panel keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4.4.2 Description of the control panel display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
5.1 Initial commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
5.2 Installation shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.3 Frost Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
6 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.1 List of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.2 Setting the parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.2.1 Selecting the operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.2.2 Setting the time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.2.3 Programming the operating ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.2.4 Setting the domestic hot water temperature setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.2.5 Activate forced electrical back-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.3 Displaying the measured values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Contents
7679542 - v03 - 29102018 TWH Split FS 3
7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
8.1 Resolving error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
8.1.1 List of error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
8.2 Checks after a disconnection of the mains supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9 Disposal/recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
9.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
10 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10.1 EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10.2 ErP information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Contents
4 TWH Split FS 7679542 - v03 - 29102018
1 Safety
1.1 General safety instructions
Danger
This appliance is not intended for use by persons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety. Children should be supervised to
ensure that they do not play with the appliance.
Caution
In the event of a refrigerant leakage:
1. Switch off the appliance.
2. Open the windows.
3. Do not use a naked flame, do not smoke, do
not operate electrical contacts or switches
(doorbell, light, motor, lift, etc.).
4. Avoid contact with the refrigerant. Danger of
frost injuries.
5. Evacuate the property.
6. Contact a qualified professional.
Danger of electric shock
Before any work, switch off the mains supply to
the thermodynamic water heater.
Important
Only qualified professionals are permitted to
install the thermodynamic water heater, in
accordance with prevailing local and national
regulations.
Warning
Do not touch the refrigeration connection pipes
with your bare hands while the heat pump is
running. Danger of burn or frost injury.
Caution
Take precautions with the domestic hot water.
Depending on the settings of the thermodynamic
water heater, the domestic hot water temperature
may exceed 65°C.
Caution
Only genuine spare parts may be used.
1 Safety
7679542 - v03 - 29102018 TWH Split FS 5
Important
Only qualified professionals are authorised to
assemble, connect, commission and service the
installation.
1.2 Recommendations
Important
The thermodynamic water heater is intended to
be permanently connected to the domestic water
mains network.
Important
Respect the minimum and maximum water inlet
pressure to ensure correct operation of the
domestic hot water tank: refer to the chapter
Technical Specifications.
Caution
The pressure limiter device must be regularly
operated in order to remove limescale deposits
and ensure that it is not blocked.
A pressure reducer (not provided) is necessary
when the supply pressure exceeds 80% of the
calibration of the safety valve which must be
located upstream of the appliance.
As water may flow out of the discharge pipe on
the pressure limiter device, this latter must be
kept clear and open to the air.
Connect the pressure limiter device to a drain
pipe, kept open to the air, in a frost-free
environment, and at a continuous downward
gradient.
Caution
Draining the domestic hot water tank:
1. Shut off the domestic cold water inlet.
2. Open a hot water tap in the installation.
3. Open a valve on the safety unit.
4. When the water stops flowing, the domestic
hot water tank has been drained.
Caution
Install the thermodynamic water heater in a frost-
free environment.
1 Safety
6 TWH Split FS 7679542 - v03 - 29102018
Caution
Do not neglect to service the thermodynamic
water heater. Contact a qualified professional or
take out a maintenance contract for the obligatory
annual servicing of the thermodynamic water
heater.
Failure to service the appliance voids the
warranty.
Caution
Have the domestic hot water tank and heating
system drained by a qualified professional if the
home is left empty for a long period of time and
there is a chance of frost.
Important
Keep the domestic hot water tank and the
outdoor unit accessible at all times.
Important
Never remove or cover labels and data plates
affixed to the thermodynamic water heater.
Labels and data plates must be legible
throughout the entire lifetime of the
thermodynamic water heater. Immediately
replace damaged or illegible instructions and
warning labels.
Caution
Remove the thermodynamic water heater casing
only to perform maintenance and repair work.
Always put the casing back in place after such
work.
Important
Keep this document close to the place where the
appliance is installed.
Caution
To benefit from extended warranty cover, no
modifications must be made to the appliance.
Warning
In accordance with the NFC 15.100 electrical
safety standard, only qualified professionals are
permitted access to the inside of the appliance.
1 Safety
7679542 - v03 - 29102018 TWH Split FS 7
Caution
The electric part of the domestic hot water tank
must always be connected to the protective
earthing.
Earthing must comply with the prevailing
installation standards.
Earth the appliance before making any electrical
connections.
For the type and calibre of the protective
equipment, refer to the chapter Electrical
Connections in the Installation and Service
Manual.
Caution
Install the outdoor unit on a solid, stable structure
capable of bearing its weight.
Caution
Do not install the thermodynamic water heater in
a place that has an atmosphere with a high salt
content.
Caution
Do not install the thermodynamic water heater in
a place exposed to steam or combustion gases.
Warning
Do not bring the heating water and the domestic
water into contact with each other in the the
heating system.
1 Safety
8 TWH Split FS 7679542 - v03 - 29102018
1.3 Specific safety instructions
Warning
Refrigerant fluid and pipes:
Only use R-134a refrigerant fluid to fill the
system.
Use tools and pipe components especially
designed for use with
R-134a refrigerant fluid.
Use copper pipes deoxidised with phosphorus
to carry the refrigerant fluid.
Use beading to guarantee the tightness of the
connections.
Store the refrigerant connection pipes away
from dust and humidity (risk of damage to the
compressor).
Cover both ends of the pipes until the beading
process.
Do not use a load cylinder.
Regarding information on installation on the
appliance, electrical connection and connection
of the water circuit, refer to the paragraphs
below in this manual.
Regarding information on handling, servicing
and scrapping the appliance, refer to the
paragraphs below in this manual.
Caution
In order to limit the risk of being scalded, the
installation of a thermostatic mixing valve on the
domestic hot water flow pipes is recommended.
1.4
Liabilities
1.4.1
User's liability
To guarantee optimum operation of the system, you
must abide by the following instructions:
Read and follow the instructions given in the manuals
provided with the appliance.
Call on a qualified professional to carry out installation
and initial commissioning.
Get your installer to explain your installation to you.
Have the required inspections and maintenance
carried out by a qualified installer.
Keep the instruction manuals in good condition close
to the appliance.
1 Safety
7679542 - v03 - 29102018 TWH Split FS 9
1.4.2
Installer's liability
The installer is responsible for the installation and initial
commissioning of the appliance. The installer must
observe the following instructions:
Read and follow the instructions given in the manuals
provided with the appliance.
Install the appliance in compliance with prevailing
legislation and standards.
Carry out initial commissioning and any checks
necessary.
Explain the installation to the user.
If maintenance is necessary, warn the user of the
obligation to check the appliance and keep it in good
working order.
Give all the instruction manuals to the user.
1.4.3
Manufacturer's liability
Our products are manufactured in compliance with the
requirements of the various Directives applicable. They
are therefore delivered with the
marking and any
documents necessary. In the interests of the quality of
our products, we strive constantly to improve them. We
therefore reserve the right to modify the specifications
given in this document.
Our liability as manufacturer may not be invoked in the
following cases:
Failure to abide by the instructions on installing and
maintaining the appliance.
Failure to abide by the instructions on using the
appliance.
Faulty or insufficient maintenance of the appliance.
1.5 Safety data sheet: refrigerant fluid R-134a
1.5.1
Product identification
Name of the refrigerant fluid: R–134a.
1.5.2
Hazard identification
Effects harmful to health:
The vapours are heavier than air and may lead to
asphyxia owing to reduced oxygen levels.
Liquefied gas: contact with the liquid may cause
serious frost burn and eye injuries.
Product classification:
1 Safety
10 TWH Split FS 7679542 - v03 - 29102018
This product is not classified as a "hazardous
preparation" according to European Union regulations.
1.5.3 Composition of/Information on the
ingredients
Chemical nature:
1,1,1,2 - Tetrafluoroethane R-134a.
Ingredients that may lead to hazardous situations:
Tab.1 Fluid ingredients R-134a
Substance name Concentra
tion
Number CAS Number CE Classification PRP
1,1,1,2 - Tetra
fluoroethane
R-134a
100% 811-97-2 212-377-0 1430
1.5.4
First aid
If inhaled:
Evacuate the subject from the contaminated area and
take him into the open air.
If feeling unwell: call a doctor.
In the event of contact with the skin:
Treat frost injuries like burns. Rinse with copious
amounts of tepid water, do not remove clothing (risk of
adhesion to the skin).
If skin burns appear, call a doctor immediately.
In the event of contact with the eyes:
Rinse immediately in water, holding the eyelids well
apart (at least 15 minutes).
Consult an ophthalmologist immediately.
1.5.5
Fire prevention measures
Appropriate extinguishing agents:
All extinguishing agents can be used.
Inappropriate extinguishing agents:
None to our knowledge. In the event of fire nearby,
use the appropriate extinguishing agents.
Specific hazards:
Pressure elevation: in the presence of air, an
inflammable mixture may form under certain
temperature and pressure conditions.
Effect of heat: release of toxic and corrosive vapours.
1 Safety
7679542 - v03 - 29102018 TWH Split FS 11
Special intervention methods:
Cool the volumes exposed to heat with water spray.
Protection of the firemen:
Full self-contained breathing apparatus.
Complete body protection.
1.5.6 In the event of accidental spillage
Individual precautions:
Avoid contact with the skin and eyes.
Do not intervene without appropriate protective
equipment.
Do not inhale the vapours.
Evacuate the hazardous area.
Stop the leakage.
Eradicate all sources of ignition.
Ventilate the spillage area mechanically (risk of
asphyxia).
Cleaning / Decontamination:
Allow residual product to evaporate.
1.5.7 Handling
Technical measures:
Ventilation.
Precautions to be taken:
No smoking.
Prevent the build-up of electrostatic charges.
Work in a well ventilated place.
1.5.8 Personal protection
Respiratory protection:
If ventilation is insufficient: AX type cartridge mask.
In confined spaces: self-contained breathing
apparatus.
Hand protection:
Protective gloves in leather or nitrile rubber.
Eye protection:
Safety glasses with side protection.
Skin protection:
Clothing made mostly of cotton.
Industrial hygiene:
Do not drink, eat or smoke in the work place.
1 Safety
12 TWH Split FS 7679542 - v03 - 29102018
1.5.9
Regulations
Regulation (EU) No. 517/2014 of the European
Parliament and of the Council of 16 April 2014 on
fluorinated greenhouse gases and repealing
Regulation (EC) No. 842/2006.
Classified installations No. 1185.
1 Safety
7679542 - v03 - 29102018 TWH Split FS 13
2 About this manual
2.1 Website
The user manual can also be found on our website.
2.2 General
This manual is intended for the end user of a TWH Split FS 200 E or TWH
Split FS 270 E thermodynamic water heater comprising a SFS 200 E or
SFS 270 E domestic hot water tank and an SODU 2 M outdoor unit with
display.
2.3
Symbols used
2.3.1 Symbols used in the manual
This manual uses various danger levels to draw attention to special
instructions. We do this to improve user safety, to prevent problems and to
guarantee correct operation of the appliance.
Danger
Risk of dangerous situations that may result in serious personal
injury.
Danger of electric shock
Risk of electric shock.
Warning
Risk of dangerous situations that may result in minor personal
injury.
Caution
Risk of material damage.
Important
Please note: important information.
See
Reference to other manuals or pages in this manual.
2.3.2 Symbols used on the appliance
1 Alternating current
2 Protective earthing
3 Before installing and commissioning the appliance, carefully read
the instruction manuals provided.
4 Dispose of used products through an appropriate recovery and
recycling structure.
5 Caution: danger of electric shock, live parts. Disconnect the mains
power prior to carrying out any work.
6 Electrical back-up
7 CE Marking: equipment conforming to European legislation
8 NF Marking: equipment that respects French safety and
performance criteria
9 Protection rating.
Fig.1 Symbols used on the appliance
MW-4000099-1
1
2
3
4
5
6
7
8
9
IPX1B
2 About this manual
14 TWH Split FS 7679542 - v03 - 29102018
3 Technical specifications
3.1 Homologations
3.1.1 Certifications
NF certification
Specifications LCIE 103–15/B (July 2011) for NF Electricity Performance
Marking
This product complies with the requirements of the following NF
Electricity Standards:
EN 60335-1:2012 + A11:2014
EN 60335-2-21:2003 + A1:2005 + A2:2008
EN 60335-2-40:2003 + A11:2004 + A12:2005 + A1:2006 + A2:2009 +
A13:2012
EN 62233:2008
EN 16147:2011
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
Electrical Conformity / CE Marking
This product complies with the requirements of the following European
Directives and Standards:
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standards: EN 60335-2-21, EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014
3.1.2 2014/68/UE Directive
This product conforms to the requirements of European Directive
2014/68/UE, article 4, paragraph 3, on pressure equipment.
3.1.3 Ecodesign Directive
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
3.1.4 Factory test
Before leaving the factory, each appliance is tested for the following:
Water tightness
Air tightness
Electrical tests (components, safety).
3.2
Technical data
3.2.1
Technical data - Heat pump water heaters
Tab.2 Technical parameters for heat pump water heaters
Parameters Unit TWH Split FS 200 E TWH Split FS 270 E
Daily electricity consumption (
Q
elec
) kWh 3.578 5.617
Declared load profile - L XL
Sound pressure level at 1 m indoors (
L
WA
)
(1)
dB(A) 17 17
3 Technical specifications
7679542 - v03 - 29102018 TWH Split FS 15
Parameters Unit TWH Split FS 200 E TWH Split FS 270 E
Daily fuel consumption (
Q
fuel
) kWh
Emissions of nitrogen oxides (
NO
X
) mg/kWh
Weekly fuel consumption with smart controls (
Qfuel,
week
,
smart
) kWh - -
Weekly electricity consumption with smart controls (
Q
elec
,
week
,
smart
)
kWh - -
Weekly fuel consumption without smart controls (
Q
fuel
,
week
,
smart
) kWh - -
Weekly electricity consumption without smart controls (
Q
elec
,
week
,
smart
)
kWh - -
Storage volume (V) l 215.0 270.0
Mixed water at 40°C (V40)
(2)
l 300 373
Sound power level (L
WA
) outdoors
(1)
dB(A) 57 57
Output (outdoor unit) with air temperature = 7°C W 1750 1750
Absorbed electrical power (outdoor unit) W 900 900
Heating time (10-54°C)
(3)
hours 5.5 7.1
COP in accordance with the EN16147 standard
(3)
- 3.30 3.42
Pes (Power)
(3)(4)
W 26.5 28.5
Air flow rate - maximum
m
3
/h
1300 1300
Immersion heater output W 2400 2400
Operating pressure MPa (bar) 1.0 (10) 1.0 (10)
Power supply voltage V 230 230
Circuit breaker A 16 16
R134a refrigerant kg 1.60 1.60
R-134a refrigerant
(5)
tCO
2
e 2.28 2.28
Length of the refrigeration connection (minimum / maximum) m 2 / 20 2 / 20
Maximum difference in height on the refrigeration connection m 10 10
Weight of the domestic hot water tank (empty) kg 70 82
Protection of the domestic hot water tank IP X1B X1B
Weight of the outdoor unit kg 33 33
Protection of the outdoor unit IP 24 24
Limit operating temperatures of the outdoor unit °C -15 / 42 -15 / 42
Settings range for the domestic hot water set point °C 38 / 75 38 / 75
(1) Value obtained at average air temperature of 20°C when heating from 10°C to 55°C.
(2) The equivalent volume of hot water at 40 °C.
(3) Value obtained with an air temperature of 7°C and a cold water temperature of 10°C, according to LCIE Specifications No. 103-15/
B:2011 based on the NF EN 16147 standard, with a 5-m long refrigeration connection with 0 m difference in height.
(4) Electrical power consumed with no hot water use.
(5) Quantity of refrigerant calculated in tonnes of CO
2
equivalent.
Important
The values in tonnes of CO
2
equivalent are calculated using the
following formula: quantity (in kg) of refrigerant fluid x GWP/1000.
GWP = Global Warming Potential. The GWP of R-134a is 1430.
3 Technical specifications
16 TWH Split FS 7679542 - v03 - 29102018
4 Description of the product
4.1 General description
The thermodynamic water heaters in the KALIKO SPLIT range have the
following specifications:
Floor-standing thermodynamic storage water heater,
Heat pump extracting energy from the outside air,
Control panel used to:
display the domestic hot water temperature,
adjust the timer program.
2.4 kW steatite immersion heater,
Glass-lined tank protected by magnesium anode,
Very thick insulation (0% CFCs).
The domestic hot water tank can be heated by:
The outdoor unit,
The immersion heater (up to 75°C).
4.2
Operating principle
4.2.1 Thermodynamic water heater
The thermodynamic water heater uses the outside air to produce domestic
hot water.
The refrigerant circuit is a closed circuit in which the R134a refrigerant
plays the role of an energy carrier.
The heat from the intake air is transferred to the refrigerant in the finned
heat exchanger at a low evaporation temperature.
The refrigerant is drawn in in vapour form by a compressor, which raises it
to a higher pressure and temperature and sends it to the condenser. In the
condenser, the heat extracted in the evaporator and some of the energy
absorbed by the compressor are released into the water.
The refrigerant is depressurised in the expansion valve and then cooled.
The refrigerant fluid can again extract the heat contained in the intake air
from the evaporator.
1
Domestic hot water tank
2
Outdoor unit
3
Condenser
4
Evaporator
5
Compressor
6
Expansion valve
7
Fan
8
Air flow
Fig.2 Schematic diagram
MW-4000108-1
1
6
7 4 5 3
8
2
4 Description of the product
7679542 - v03 - 29102018 TWH Split FS 17
4.2.2 Operating principle for the thermodynamic water heater
with outdoor unit
Depending on the source of energy used to heat the water in the
thermodynamic water heater (heat pump only, immersion heater only, or
heat pump and immersion heater combined), the heating time for the
thermodynamic water heater varies according to the room temperature.
Only half the capacity of the domestic hot water tank is heated when the
energy source is immersion heater only.
X Room temperature (°C)
Y Heating time (hours)
1 Source of energy: heat pump and immersion heater combined
2 Source of energy: immersion heater
3 Source of energy: heat pump
X Room temperature (°C)
Y Heating time (hours)
1 Source of energy: heat pump and immersion heater combined
2 Source of energy: immersion heater
3 Source of energy: heat pump
4.2.3 Operation of various MODES
The main and default heat source for the thermodynamic water heater is
the heat pump.
If the room temperature is outside the heat pump's operating range, it will
cease the function. The water heater automatically activates the
immersion heater and the code bA is shown on the control panel display.
The room temperature range adapted for this operating mode is between
-15°C and +43°C.
For the 3 operating modes:
the thermodynamic water heater can heat the domestic hot water to a
maximum temperature of 65°C,
the domestic hot water temperature set point can be set to between 25
and 75°C.
Operation in AUTO MODE = AUTOMATIC MODE
The thermodynamic water heater can heat the water using the following
sources of energy:
the heat pump,
the immersion heater
or both systems simultaneously.
Fig.3 Model TWH Split FS 200 E
y
x
0
-20 -10 0 10 20 30 40 50
5
10
15
MW-1000861-1
1
2
3
Fig.4 Model TWH Split FS 270 E
y
x
1
2
3
0
-20 -10 0 10 20 30 40 50
5
10
15
18
MW-1000862-1
4 Description of the product
18 TWH Split FS 7679542 - v03 - 29102018
Tab.3
T = Ambient temperature Source(s) of energy used
At least one of the following 3 con
ditions must be true:
T < –15 °C
Water temperature > variable
temperature set point according
to the outdoor temperature
T > +43 °C
Immersion heater
–15 °C < T < Td Heat pump and immersion heater
operate simultaneously if necessa
ry
The following 2 conditions must be
true:
T > Td
Water temperature < 65°C
Heat pump
Operation in HYBRID MODE = HYBRID MODE
Important
HYBRID MODE = HYBRID MODE: heat pump with compulsory
coupling to an instant boiler.
The thermodynamic water heater can heat the water using 2 sources of
energy: heat pump and instant boiler:
the heat pump is intended to preheat the domestic hot water,
the instant boiler is used to heat the domestic hot water to the required
temperature for use.
No electrical back-up for this mode.
Tab.4
T = Ambient temperature Source(s) of energy used
T < T4 Instant boiler
T4 < T < 43 °C
Water temperature < 65°C
Heat pump + instant boiler
Operation in OPT.BACKUP = OFF-PEAK RATE/PEAK RATE
OPTIMISATION MODE
The thermodynamic water heater can only heat the water during:
the programmed timer range,
or when the off-peak rate signal is present.
The thermodynamic water heater can heat the water using the heat pump
or the immersion heater:
the heat pump operates as the priority source,
the immersion heater starts when the heat pump is operating, to enable
the required temperature set point to be reached before the end of the
period.
4 Description of the product
7679542 - v03 - 29102018 TWH Split FS 19
Tab.5
T = Ambient temperature Source(s) of energy used
T < –15 °C
Water temperature > variable
temperature set point according
to the outdoor temperature
T > +43 °C
Immersion heater
-15°C < T < 43°C Heat pump and immersion heater
operate simultaneously if necessa
ry
4.2.4 Limit temperatures of the thermodynamic water heater
X
Air temperature (°C)
Y
Domestic hot water temperature (°C)
The graph opposite shows the maximum temperature at which the outdoor
unit can heat up the water in the domestic hot water tank according to air
temperature.
To preserve the components and maintain an optimal service life of the
thermodynamic water heater, the outdoor unit works at temperatures of
between -15°C and +42 °C. Outside of this temperature range, the surplus
heating of the domestic hot water is provided by the immersion heater.
Fig.5
MW-4000102-3
40
35
-15 -10
-7
2 32 4337
X
58
55
60
62
65
Y
-2
4 Description of the product
20 TWH Split FS 7679542 - v03 - 29102018
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

De Dietrich KALIKO TWH Split FS 200 E User manual

Category
Heat pumps
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI