Thank You for buying automatic hot air pellet stove of series „Pony”.
This manual will help You to use and maintain the unit properly.
NOTE : the model “Pony PS9” is designed mainly for single room heating
purposes, while the model “Pony PS9D” is equipped with additional hat air
channel for supplying another room with hot air, prepared by the stove’s heat
exchanger.
ATTENTION!
IN INTEREST OF YOUR PERSONAL SECURITY IT IS
OBLIGATORY TO READ THOROUGHLY AND CAREFULLY THIS
INSTRUCTION MANUAL BEFORE PROCEEDING WITH ANY
ACTIONS WITH THE STOVE – MOUNTING, CONNECTING, ETC. IN
CASE THAT REQUIREMENTS, DEPICTED IN THIS MANUAL ARE
NOT SATISFIED, FAILURES OF THE UNIT COULD BE EXPECTED,
OR EVEN FATAL CONSEQUENCES, FOR WHICH THE STOVE
PRODUCER COMPANY DOES NOT TAKE RESPONSIBILITY.
Producer ZMM Haskovo Plc.
Address Bulgaria, Haskovo 6300, “Saedinenie” 67 blvd.
Phone +359 800 15 145
Fax +359 38 603070
home page www.greenecotherm.eu
User manual for automatic hot air pellet stove of series “Pony” (model “Pony PS9” and “Pony PS9D”);
(document version: 28.02.2012 10:40)
Page. 3/61
CONTENTS
Page
1. Description and advantages of automatic hot air pellet stove of series
“Pony”. ................................................................................................................. 5
2. Technical data of automatic hot air pellet stove of series “Pony”........ 7
Table 2.1 Thermal and technical data for hot air stove of series “Pony”,
utilizing wood pellets......................................................................................... 8
Table 2.2. Operating parameters of the heated air, supplied thought the ducts
to another room – valid for model “Pony PS9D” only, at totally closed air
distribution control flap...................................................................................... 8
Table 2.3 Dimensions and technical data of hot air stove of series “Pony”,
utilizing wood pellets......................................................................................... 9
Table 2.4 Recommended solid fuel properties – wood pellets ............................ 9
Table 2.5 ENplus - European standard for wood pellets; ............................... 10
3. Description of the construction of hot air automated pellet stove
“Pony PS9”......................................................................................................... 11
4. Installation process. ................................................................................ 21
4.1. Norms and recommendations :.............................................................. 21
4.2. Norms and recommendations ................................................................ 21
4.3. Installation process of the stove............................................................. 22
4.4. Appliance positioning in order to achieve comfortable maintenance....
................................................................................................................... 23
4.5. Connecting the stove to a chimney ........................................................ 25
4.6. Connection of the hot air pellet stove , model “Pony PS9D” with hot
air duct for heating another room in a dwelling ............................................ 29
5. Entering the appliance in service. ......................................................... 31
5.1. Basic fuel requirements....................................................................... 31
5.2. Starting hot air pellet stove of series “Pony” procedure. ................ 32
5.2.1. Interface control board of hot air pellet stove of series “Pony”
..................................................................................................... 33
5.2.2. Description of the function of the buttons of the interface
panel. ..................................................................................................... 34
5.2.3. Power supply of the stove ......................................................... 36
5.2.4. Turning ON the appliance........................................................ 36
5.2.5. Set up of the stoves operating parameters.............................. 38
Page. 4/61
5.2.6. Set up of the stove according to the thermal power needed.. 42
5.2.8. Adjustment of the operating parameters of the hot air,
supplied to a neighboring room – valid for model “Pony PS9D” only. ....... 43
5.2.9. Nominal operating mode of the stove...................................... 43
5.3. Adjustment of the thermal capacity of the stove.............................. 44
5.3.1. Decreasing the thermal capacity of the stove ......................... 44
5.3.2. Decreasing the thermal capacity of the stove ......................... 44
5.3.3. Adjustment of the thermal capacity of the hot air, supplied to
the neighboring room – valid for model “Ponu PS9D” only......................... 45
5.4. Stopping the operation of the stove.................................................... 45
5.5. Cleaning the stove................................................................................ 45
5.6. Turning OFF the stove........................................................................ 49
Emergency stop of the stove................................................................. 49
5.7. Showing and teaching the end user about the maintenance and
adjustment procedures. ................................................................................. 50
5.8. Safety and unexpected risks ............................................................... 50
5.9. Operation faults and their repairing from the end user.................. 52
5.10. Alarm messages, shown on the display of the stove ......................... 55
Table 5.8. Alarm messages, shown on the display of the stove ..................... 55
5.11. Operation faults and their repairing from the service personal
ONLY .............................................................................................................. 56
5.12. Hot air pellet stove of series „ Pony” warranty form completion. ... 59
5.13. Actions, after the unit is not in exploitation anymore...................... 59
6. Electrical scheme of the apliance........................................................... 60
WARRANTY CONDITIONS .......................................................................... 61
Page. 5/61
1. Description and advantages of automatic hot air pellet stove of
series “Pony”.
The unit of series “Pony PS9” is steel-plate hot air pellet stove, which uses
solid biomass fuel in shape of pellets. The stove is designed for local heating
of domestic and office spaces. The stove utilizes wood pellets, as well as
other type/shape of biomass; the resulting heat energy from thermo-chemical
conversion (i.e. combustion process) is transmitted from the heat-exchanging
surfaces to the surrounding air, both by convection as well as thermal
radiation. The model “Pony PS9D” is equipped with additional hot air duct
for heating more that a single room.
The complete set of the pellet stove consists of:
Automatic hot air pellet stove– 1 ct;
Battery – Toshiba 23A, 12v, V23GA – 1 ct;
Remote control - 1 ct;
Plastic heels M10 X 43 - 4 ct;
Handle - 1 ct;
PC power supply cable AC 220V - 1 ct;
Users guide for automatic hot air pellet stove of series “Pony” 1 ct;
The unit could utilize following types of fuel:
Wood pellets, having diameter 6 mm, covering the requirements of
class ENplus-A1 of standard EN 14961-2:2010;
Other solid biomass based pellets, but confirmation for these fuels
utilization need testing and approval by stove’s producer company
laboratory;
The unit is equipped with:
Steel plates welded heat exchanger for heating-up the surrounding air;
Flue gas fan;
Fan for forced convection and heating-up of the surrounding air;
Daily fuel hopper with capacity of about 19 kg;
Programmable operating module, which controls the functions of the
unit and is adjustable to the specific needs of the client;
Ash container with capacity of 0.5 kg;
Page. 6/61
The model “Pony PS9D” only : the unit is designed with additional air
flow control system, allowing hot air distribution control and hot air
supply duct fir heating another room;
The unit is supplied with:
Automatic fuel ignition system;
Automatic fuel feeding auger system;
Remote control;
Unit’s advantages:
The hot air stove gives you an incredible feel of warmth and comfort due
to a controlled and highly efficient combustion process;
The model “Pony PS9D” is redesigned in order to allow simultaneous hot
air supply to another room of the dwelling;
The hot air stove is designed to utilize solid biomass fuel, making it
environmentally friendly, CO2 neutral and does not contribute to the
global warming process – result of fossil fuel utilization;
The specific price of the heat energy, delivered by solid biomass
utilization is less dependent on the world fuel market trends and
practically the heat energy price is competitive to the conventional energy
sources;
The stove is automatic and the thermal comfort achieved is close to that,
originating from exploitation of fully automatic heaters, (for example
running on liquid or gas fuel, as well as electric heaters). The stove is
equipped with integrated programmable room thermostat (daily, weekly
and weekend programs);
The unit is equipped with automatic fuel ignition system and performs
burner’s ash cleaning procedure, controlled by the electronic module;
Remote control of the operating mode of the stove;
The stove utilizes wood pellets, covering the requirements of class
ENplus-A1 of standard ENplus, or other standards as ONORM M7135,
DIN 51731 и DINPlus;
High efficiency;
Low pollutant contents in the flue gases;
Automatic fuel feeding system, transported from the built-in “daily”
hopper to the burner;
Simplified maintenance and service procedures;
Minimized running costs;
Page. 7/61
2. Technical data of automatic hot air pellet stove of series
“Pony”
Thermal and technical data for hot air stove of series “Pony”, utilizing wood
pellets are given in Table 2.1;
Operating parameters of the hot air, heated up by pellet stove “Pony PS9D”
are given in Table 2.2;
Dimensions and technical data for hot air pellet stove of series “Pony” are
given in Table 2.3;
Recommended solid fuel properties – wood pellets, are given in Table 2.4;
The European standard for wood pellets properties is given in Table 2.5;
Page. 8/61
Parameter Dimension Value
Nominal thermal capacity kW 9
Thermal capacity operation range kW 3.5 – 9
Utilized solid fuel Wood pellets diameter d=6mm
Utilized pellets, complying ENplus ENplus – A1
Wood pellets fuel consumption rate at
nominal thermal capacity kg/h 2.1
kg/h 16 - 18
Fresh air flow rate, required for effective
combustion process m3/h 14 - 16
Averaged wood pellets consumption rate kg/h 1.2
Average refueling cycle h up to 20
Thermal efficiency at nominal capacity up to 90
Air excess ratio λ 1.6 – 1.9
Flue gases temperature at nominal thermal
capacity ºC 160 – 200
Solid fuel residue ash
The quantity depends
on the ash contents in
the raw fuel, as well
as operating
conditions
Table 2.1 Thermal and technical data for hot air stove of series
“Pony”, utilizing wood pellets.
Parameter Dimension Value
Temperature at nominal thermal
capacity 160 - 190
Temperature at minimal thermal
capacity
ºC
115 - 130
Heating capacity of the hot air at
nominal operating mode 4.0 - 4.4
Heating capacity of the hot air at
minimal operating mode
kW
1.8 - 2.0
Table 2.2. Operating parameters of the heated air, supplied thought the ducts to
another room – valid for model “Pony PS9D” only, at totally closed air
distribution control flap.
NOTE : the data, shown in above table should be considered tentative, as in
practice the temperature of the heated air, as well as the air flow rate are strong
function of the ambient air and mainly the hydraulic loses in the hot air duct,
Page. 9/61
which conducts the hot air to another room (mainly the length as well as the
number and configuration of the curves).
Parameter Dimension Value
Model - PS9 PS9D
Weight kg 91 105
dm³ 29
Fuel hopper capacity kg 19 kg (wood pellets
d=6mm)
Overall dimension of the unit (WxDxH) mm 470x612x1083
Class (according to EN 303-5) - 3
Recommended air temperature in the heated
space ºC 20
Minimum air temperature in the heated
space ºC 14
Draught Pa 4 - 10
Fresh air channel mm 35
Flue gases duct mm 80
Connections
Hot air duct mm --- 80
Electrical supply - 50Hz; 230V
Electrical power VA
<100
< 350 (at ignition
process)
Environment protection index - IP20
Table 2.3 Dimensions and technical data of hot air stove of series
“Pony”, utilizing wood pellets.
The recommended fuel for hot air stove of series “Pony”, utilizing pellets is:
wood pellets with specific size – diameter 6 mm. Main properties of the fuel are
given in the next table.
Parameter Dimension Value
Pellet’s characteristic size mm 6
Pellet’s characteristic length mm Max 30
MJ/kg >17.2 Recommended fuel net calorific value (low
heating value) kWh/kg >4.7
Wood pellet class according to ENplus ENplus-A1
Ash content % See Table 2.4.
Moisture content % Max. 8 – 10%
Table 2.4 Recommended solid fuel properties – wood pellets
Page. 10/61
The European wood pellets standard EN 14961-2:2010
defines wood pellets certificate ENplus for pellets, utilized
in boilers, stoves and appliances for domestic heating
systems. The certificate EN-B is applied for pellets, utilized
in industrial boilers. In principal the ENplus standard defines
two quality classes: А1 и А2. The class А1 is highly
restricted, considering the ash content. The class А2 the limit of the ash content
of the wood pellets is higher – up to 1.5%. For industrial boilers the certificate
EN-B is applicable, which defines fewer restrictions on the pellets quality.
Parameter Dimension ENplus-A1 ENplus-A2
Diameter mm 6 (± 1) 6 (± 1)
Length mm 3,15 L 40 1) 3,15 L 40 1)
Bulk density kg/m³ 600 600
Low calorific value MJ/kg 16.5 16.5
Moisture content % 10 10
Dust % 13) 1 3)
Mechanical durability % 97.5 4) 97.5 4)
Ash content % 2) 0,7 1.5
Ash melting point temperature °C 1200 1100
Cl %
2) 0.02 0.03
S % 2) 0.05 0.05
N %
2) 0.3 0.5
Cu mg/kg 2) 10 10
Cr mg/kg
2) 10 10
As mg/kg 2) 1 1
Cd mg/kg
2) 0.5 0.5
Hg mg/kg 2) 0.1 0.1
Pb mg/kg
2) 10 10
Ni mg/kg 2) 10 10
Zn mg/kg
2) 100 100
1) not more that 1% of the wood pellets should be with length of 40 mm, the maximal pellet
length is 45 mm ;
2) determined on dry mass;
3) the particles are <3.15 mm, fine particles, before fuel delivery;
4) in case the test measurements are performed with Lignotester, than the limit value is
97.7% m.w.;
Table 2.5 ENplus - European standard for wood pellets;
Page. 11/61
3. Description of the construction of hot air automated pellet
stove “Pony PS9”
The heat exchanger of the stove complies with the acting requirements for
such kind of units, defined in operating norm: EN 14785:2006 – „Heating units
for dwellings, utilizing wood pellets. Terminology, requirements, testing and
marking”.
The unit consists of:
Main part of the unit is heat exchanger. In the combustion chamber of
this exchanger is mounted specialized grate burner, designed for
horizontal fuel feeding;
The heat exchanger is welded construction of carbon steel plates. The
lower part of the exchanger is designed as combustion chamber. The
burner is mounted in this chamber and under is the ash container.
Combustion chamber: It is designed to provide conditions for optimal
burning process and helps for complete combustion of the fuel. The
chamber is closed by a door with heat-resistant (ceramic) glass, giving the
possibility to see the combustion process and also provides direct heat
radiation to the surrounding objects.
Stainless steel burner, mounted in the combustion chamber of the heat
exchanger;
Ash container, positioned in the lower part of the combustion chamber,
below the burner;
Fuel hopper is mounted right behind of the stoves’s burning chamber. In
the hopper (in the center and inclined) is mounted a fuel transport auger;
Fresh air for burning is provided by a pipe. The air for burning needs to
be with room temperature. Do not connect the pipe directly to the outside
of the building;
Flue gases exit duct is positioned in the lower rear side of the unit (after
the flue gases fan, concerning the flue gases flow direction), utilized for
forced flue gases extraction;
Hot air duct, which allows the heated ambient air to be convected to
another room – this is valid for model “Pony PS9D” only. The size of the
duct is shown in Table 2.2. The hot air distribution is controlled by a level
drive flap, installed in the front upper section on the unit;
Control unit it is placed in a cold zone of the stove and provides save
function of the appliance. The control is equipped with a lithium battery,
Page. 12/61
which has live time of 5 years – it is used to memorize the settings of the
control module in cases of interrupted main power supply. In order to
maintain safe function the stove is supplied with a pressure switch for
monitoring the functionality of the chimney. In cases of malfunction of
the chimney, the pressure switch stops the stove immediately, preventing
damages to the appliance and emergency situations. Also the stove is
monitoring the flue gases temperature. In cases of increased temperatures,
the controller of the stove goes in minimum power, or in case of excessive
values, it shuts down the unit;
Interface panel is used for set up of the control unit. And to monitor the
work parameters and massages;
The heat exchanger, fuel hopper and other modules of the stove are
covered with decorative covers , powder painted in different colors;
Page. 13/61
Figure 3.1. External view and description of the main modules of hot air stove
of series “Pony”;
The characteristic dimensions of the automatic hot air pellet stove of series
“Pony” are shown on the Figures 3.2 – 3.5.
Interface panel of the control
module of the stove
Fuel hopper lid
Decorative guiding grill for
the hot air
Door with fire-resistant glass
Handle
Cover of the ash container
Page. 14/61
Figure 3.2. Front side view of automatic hot air pellet stove of series “Pony”;
Page. 15/61
Figure 3.3. Back side view of automatic hot air pellet stove , model “Pony PS9”
Exhaust gases
outflow duct
Fresh air for
combustion inlet
Page. 16/61
Figure 3.4. Back side view of automatic hot air pellet stove, model “Pony
PS9D”
Hot air outflow duct
Exhaust gases
outflow duct
Fresh air for combustion
inlet
Page. 17/61
Figure 3.5. View of automatic hot air pellet stove of series “Pony” – top side
view and left side view;
Page. 18/61
Main modules/elements of hot air stove , model “Pony PS9” are given in figure
3.6.
Figure 3.6. Cross section view and description of the main modules/elements of
hot air stove, model “Pony PS9”.
Fuel hopper
Fuel transport auger
Interface panel of the control
module of the stove
Fuel transport auger motor
Pipe for fresh air
Hot air fan
(forced convection fan)
Stainless-steel burner
Flue-gas duct
Flue gas fan
Ash container
Combustion chamber door
Guiding plate – back of the combustion chamber
Page. 19/61
Figure 3.7. Cross section view and description of the main modules/elements of
hot air stove, model “Pony PS9D”;
Fuel hopper
Fuel transport auger
Interface panel of the control
module of the stove
Fuel transport auger
Pipe for fresh air
Hot air fan
Stainless-steel burner
Flue-gas duct
Flue-gas fan
Ash container
Combustion chamber door
Guiding plate – back of the
combustion chamber
Hot air duct (for heating
another room)
Page. 20/61
Figure 3.8. Side view of the lever for controlling air distribution flap of hot air
pellet stove , model “Pony PS9D” . In the given position of the lever (the lever is
pushed to the grill) the air flap is closed and to another room the hot air flow
rate is minimized;
Figure 3.9. Side view of the lever for controlling air distribution flap of hot air
pellet stove , model “Pony PS9D” . In the given position of the lever (the lever is
pulled from the grill) the air flap is opened and to another room the hot air flow
rate is maximized;
NOTE : the heat by the stove air is force convected by a centrifugal fan, which
is installed section on the basis of the heat exchanger. So in case of change of
the position of the lever for controlling the position of the air distribution flap,
the room, where the stove is installed, continues to receive heat energy, mainly
by radiation and natural convection;
The lever for air distribution flap
control flap is pushed to the unit
The lever for air distribution flap control
flap is pulled out from the unit
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63

green ecotherm Pony PS9 User manual

Category
Stoves
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI