White Rodgers 37-5148B User manual

Category
Thermostats
Type
User manual

This manual is also suitable for

PART NO. 37-5148B
Replaces 37-5148A
9607
Printed in U.S.A.
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
PRECAUTIONS
DESCRIPTION
This adaptor plate assembly is designed for mounting a
1F6X, 1F7X, or 1F9X series thermostat to the wall or to a
junction box. The wall cover plate covers the junction box,
wall damage, or old thermostat markings. The adaptor
plate is designed to allow horizontal thermostat mounting,
regardless of junction box orientation.
All kits may not have adaptor plate or all screws shown.
Wall Cover
Plate
Adaptor Plate
No. 6 X
5
16
” Phillips
pan-head screw (2)
6-19 X
3
8
” Phillips
pan-head screw (3)
6-32 X
3
4
” flat-head
machine screw (4)
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
CONTENTS
Description......................................................... 1
Precautions........................................................ 1
Installation.......................................................... 2
For 1F9X Digital Thermostats
For 1F7X Quartz Clock Thermostats
For 1F6X Thermostats
WHITE-RODGERS
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
F61 Series
Adaptor Plate Assembly
To prevent electrical shock and/or equip-
ment damage, disconnect electrical power
at main fuse or circuit breaker until installa-
tion is complete.
This instruction sheet is not intended as a wiring guide.
Refer to the thermostat installation instructions to ensure
proper wiring.
NOTE
CAUTION
!
2
INSTALLATION
Thermostat
Thermostat Subbase
(may have 2, 3, or
4 mounting holes)
Wall Cover Plate
Junction Box
Figure 1. Mounting 1F9X digital thermostat to horizontal junction box
No. 6 X
5
16
” Phillips
pan-head screws
6-32 X
3
4
” flat-head
machine screws
Thermostat
Thermostat Subbase
(may have 2, 3, or
4 mounting holes)
Wall Cover Plate
Junction Box
Adaptor Plate
Figure 2. Mounting 1F9X digital thermostat to vertical junction box
No. 6 X
5
16
” Phillips
pan-head screws
6-32 X
3
4
” flat-head
machine screws
Locate and drill two
clearance holes in wall
6-32 X
3
4
” flat-head
machine screws
FOR 1F9X DIGITAL THERMOSTATS
3
NOTE
Wall Cover Plate
Figure 3. Mounting 1F9X digital thermostat to wall
Wall
Thermostat
Thermostat Subbase
No. 6 X 1” pan-head screws
(supplied with thermostat)
Wall Cover Plate
Junction Box
50 60 70 80 90
9
1
2
3
6
9
1
2
3
6
DAY
90
80
70
60
50
HI
LO
Thermostat
AUTO
OFF
FAN
ON
SYSTEM
COOL HEAT
Thermostat
Subbase*
Wall Mounting
Plate*
Figure 4. Mounting 1F7X quartz clock thermostat to horizontal junction box
6-32 X
3
4
” flat-head
machine screws
*Do not use both subbase and wall
mounting plate – see note, above.
6-32 X
3
4
” flat-head
machine screws
When installing wall cover plate and thermostat directly to
wall, use the pointed screws supplied with the thermostat.
FOR 1F7X QUARTZ CLOCK THERMOSTATS
Do not install the wall mounting plate and subbase at the
same time. The thermostat will not operate properly if both
wall mounting plate and subbase are installed.
NOTE
4
Wall Cover Plate
50 60 70 80 90
9
1
2
3
6
9
1
2
3
6
DAY
90
80
70
60
50
HI
LO
Thermostat
AUTO
OFF
FAN
ON
SYSTEM
COOL HEAT
Thermostat
Subbase*
Wall Mounting
Plate*
Junction Box
Adaptor Plate
Figure 5. Mounting 1F7X quartz clock thermostat to vertical junction box
6-32 X
3
4
” flat-head
machine screws
6-32 X
3
4
” flat-head
machine screws
*Do not use both subbase and wall
mounting plate – see note, above.
Locate and drill two
clearance holes in wall
6-32 X
3
4
” flat-head
machine screws
50 60 70 80 90
9
1
2
3
6
9
1
2
3
6
DAY
90
80
70
60
50
HI
LO
Thermostat
AUTO
OFF
FAN
ON
SYSTEM
COOL HEAT
Thermostat
Subbase*
Wall Mounting
Plate*
Wall
Figure 6. Mounting 1F7X quartz clock thermostat to wall
No. 6 X 1” pan-head screws
(supplied with thermostat)
Wall Cover Plate
*Do not use both subbase and wall
mounting plate – see note, above.
No. 6 X 1” pan-head screws
(supplied with thermostat)
Do not install the wall mounting plate and subbase at the
same time. The thermostat will not operate properly if both
wall mounting plate and subbase are installed.
NOTE
Do not install the wall mounting plate and subbase at the
same time. The thermostat will not operate properly if both
wall mounting plate and subbase are installed.
NOTE
When installing wall cover plate and thermostat directly to
wall, use the pointed screws supplied with the thermostat.
NOTE
5
FOR 1F6X THERMOSTATS
Wall Cover Plate
Junction Box
Thermostat Cover
Thermostat
Instructions Inside Cover
Figure 7. Mounting 1F60 thermostat to horizontal junction box
No. 6 X
3
8
” Phillips
pan-head screws
6-32 X
3
4
” flat-head
machine screws
Wall Cover Plate
Thermostat Cover
Junction Box
Adaptor Plate
Thermostat
0 3 6 9°C
0 5 10 15°F
AUTO CONT.
FAN
COOL OFF HEAT
SET
BACK
TIME
SET
Figure 8. Mounting 1F60 thermostat to vertical junction box
No. 6 X
3
8
” Phillips
pan-head screws
6-32 X
3
4
” flat-head
machine screws
Locate and drill two
clearance holes in wall
6-32 X
3
4
” flat-head
machine screws
6
When installing wall cover plate and thermostat directly to
wall, use the pointed screws supplied with the thermostat.
Wall Cover Plate
Junction Box
Thermostat Cover
Thermostat Subbase
AM
PM
SETBACK
HEAT
COOL
Instructions Inside Cover
WHITE-RODGERS
COMPRESSOR
MALFUNCTION
EMERGENCY
HEAT
AUXILIARY
HEAT
10 50
55
60
65
70 21
75
80
85
90 32
°F °C
0 3 6 9°C
0 5 10 15°F
AUTO CONT.
FAN
COOL OFF HEAT EMHT
TIME
SET
SET
BACK
CLEAR
Thermostat
(connect harness –
snap onto subbase)
Figure 10. Mounting 1F62 thermostat to horizontal junction box
No. 6 X
3
8
” Phillips
pan-head screws
6-32 X
3
4
” flat-head
machine screws
Wall Cover Plate
Thermostat Cover
Thermostat
AM
PM
SETBACK
HEAT
COOL
Instructions Inside Cover
50 60 70 80 90
°F
10 21 32 °C
WHITE-RODGERS
0 3 6 9
°C
0 5 10 15
°F
AUTO CONT.
FAN
COOL OFF HEAT
SET
BACK
TIME
SET
Wall
Figure 9. Mounting 1F60 thermostat to wall
No. 6 X 1” pan-head screws
(supplied with thermostat)
No. 6 X
3
8
” Phillips
pan-head screws
NOTE
7
Wall Cover Plate
Thermostat Cover
Thermostat
Subbase
AM
PM
SETBACK
HEAT
COOL
Instructions Inside Cover
WHITE-RODGERS
COMPRESSOR
MALFUNCTION
EMERGENCY
HEAT
AUXILIARY
HEAT
10 50
55
60
65
70 21
75
80
85
90 32
°F °C
0 3 6 9°C
0 5 10 15°F
AUTO CONT.
FAN
COOL OFF HEAT EMHT
TIME
SET
SET
BACK
CLEAR
Wall
Figure 12. Mounting 1F62 thermostat to wall
No. 6 X 1” pan-head screws
(supplied with thermostat)
No. 6 X
3
8
” Phillips
pan-head screws
Thermostat
(connect harness –
snap onto subbase)
Wall Cover Plate
Junction Box
Adaptor Plate
Thermostat Cover
Thermostat
Subbase
AM
PM
SETBACK
HEAT
COOL
Instructions Inside Cover
WHITE-RODGERS
COMPRESSOR
MALFUNCTION
EMERGENCY
HEAT
AUXILIARY
HEAT
10 50
55
60
65
70 21
75
80
85
90 32
°F °C
0 3 6 9°C
0 5 10 15°F
AUTO CONT.
FAN
COOL OFF HEAT EMHT
TIME
SET
SET
BACK
CLEAR
Figure 11. Mounting 1F62 thermostat to vertical junction box
Locate and drill two
clearance holes in wall
6-32 X
3
4
” flat-head
machine screws
6-32 X
3
4
” flat-head
machine screws
No. 6 X
3
8
” Phillips
pan-head screws
Thermostat
(connect harness –
snap onto subbase)
NOTE
When installing wall cover plate and thermostat directly to
wall, use the pointed screws supplied with the thermostat.
If you need further information about this product, please write to
White-Rodgers Division, Emerson Electric Co.
9797 Reavis Road
St. Louis, MO 63123-5398
Attention: Technical Service Department
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

White Rodgers 37-5148B User manual

Category
Thermostats
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI