Roberts 7350-0 User manual

Type
User manual

This manual is also suitable for

7350
UNIVERSAL Flooring Adhesive
1. PRODUCT NAME
ROBERTS
®
7350 UNIVERSAL Flooring Adhesive
2. MANUFACTURER
Roberts Consolidated Industries, Inc.
300 Cross Plains Blvd
Dalton, GA 30721
(866) 435-8665 / (706) 277-5294
3. DESCRIPTION
ROBERTS 7350 UNIVERSAL Flooring Adhesive is a high quality, high solids,
cross-linking formulation designed specifically for installing luxury/solid vinyl
tiles/planks. This powerhouse adhesive is ideal for use with large format
vinyl tiles. Can also be used to adhere carpet tiles and specialty vinyl flooring
underlayment, such as ROBERTS SoundBarricade, to the subfloor.
Features and Benefits
Moisture Control Adhesive –
Up to 10 lbs. MVER (ASTM F1869) / 90% RH (ASTM F2170)
Ideal for LVT, LVP, WPC and Solid Vinyl Tile
Rebondable pressure sensitive, aggressive bond, permanent tack
Excellent resistance to plasticizer migration
Enviro-Friendly – solvent-free and LEED
®
compliant; VOC 11 g/L,
SCAQMD Rule 1168
Non-flammable. NFPA Class A and UBC Class 1 fire resistance
ratings (ASTM E84)
CRI Green Label Plus
®
Certified – GLP #42613
GoldGuard
®
antimicrobial product protection
Traffic – Heavy Commercial
Uses
For the interior installation of luxury/solid vinyl tile, WPC (wood plastic
composite/waterproof core) flooring, SPC (stone plastic composite) flooring,
solid rubber-backed tiles, luxury vinyl planks, solid vinyl sheet flooring,
fiberglass-backed flooring, VCT, vinyl-backed carpet tile, cork tile, cork
underlayment, specialty underlayments such as ROBERTS SoundBarricade
Universal Sound Control Underlayment (70-197), homogeneous and
heterogeneous sheet flooring, tile-over-tile installations (well bonded and
limited to one layer).
Coverage and Trowel Options*
1/16" x 1/16" x 1/16"
Flooring (porous substrate): Luxury Vinyl Tile and Plank;
SPC/
WPC Flooring;
Vinyl Composition Tile; Carpet Tile;
Cork Underlayment
Coverage: 170-190 ft
2
per gallon
1/16" x 1/16" x 3/32"
Flooring (porous substrate): Luxury Vinyl Tile and Plank;
SPC/
WPC Flooring;
Cork Underlayment
Coverage: 160-180 ft
2
per gallon
1/16" x 1/32" x 1/32"
Flooring (non-porous substrate): Luxury Vinyl Tile and Plank;
SPC/
WPC Flooring;
Cork Underlayment
Coverage: 220-260 ft
2
per gallon
Medium Nap Roller (3/8)
Flooring (non-porous substrate): Luxury Vinyl Tile and Plank;
SPC/
WPC Flooring;
Carpet Tile; Cork Underlayment
Coverage: Up to 300 ft
2
per gallon
*The trowel notches referenced are those typically recommended for the type of
flooring being installed and are shown as a guide. Consult flooring manufacturer
for their specific trowel recommendations.
Substrates
Concrete, flooring grade APA rated plywood, steel, marble, terrazzo, existing
vinyl tile flooring (well-bonded; excludes self-stick), radiant heated suboors
(surface temperature not to exceed 85ºF).
Roberts Consolidated Industries, Inc. • www.robertsconsolidated.com
SUPERIOR
M
O
I
S
T
U
R
E
C
O
N
T
R
O
L
U
P
T
O
1
0
L
B
S
.
M
V
E
R
/
9
0
%
R
H
7350
Limitations
For interior installations only.
Ensure substrate, flooring material and adhesive are fully acclimated prior
to installation at the same temperature and humidity level expected during
normal use (between 65-95°F with a relative humidity of no greater than
65%). Maintain these conditions after the installation.
Ensure adequate ventilation during flooring installation.
Refer to Safety Data Sheet, www.robertsconsolidated.com, industry
standards, and manufacturer’s guidelines and specific recommendations
prior to installation for additional information.
4. TECHNICAL DATA
Product Type:
Acrylic Latex/PSA
Color:
Off white
Odor:
Very mild
PERMANENT Installations (Wet-set method)
Open Time:
Up to 20 minutes
Working Time:
Up to 40 minutes
RELEASABLE Installations (Tack-set Method)
Tack Time:
Up to 45 minutes
Working Time:
12 to 14 hours
VOC:
11 g/L
MVER:
10 lbs or less (ASTM F1869) / 90% RH or less (ASTM F2170)
pH:
Must not exceed 10
Shelf Life:
1 year in unopened container
Storage:
Protect from freezing. Does not require thinning.
5. INSTRUCTIONS
Preparation
Suboors must be structurally sound, dry, smooth, flat ( 3/16” within 10’),
level and free of excess moisture/alkali and all substances (oil, wax, grease,
paint, oil based sealers, adhesive residue, etc.) that may inhibit the bond of the
adhesive or the performance of the flooring or its installation.
Moisture Testing must be performed in accordance to ASTM F1869 with levels
not to exceed 10 lbs/1000 ft
2
/ 24 hrs and/or ASTM F2170 with levels not to
exceed 90% RH. Large temperature or humidity increases or decreases can
affect the flooring and the performance of the installation.
When installing over existing hard surface floors, remove finish to allow a
good mechanical bond. All substrate cracks, chips, holes, joints, high spots
and irregularities must be adequately repaired. Expansion or other moving
joints must not belled or covered with flooring. Patching compounds must
be suitable for the use application, cement based and polymer-modied, and
applied according to the manufacturer’s instructions.
Installation
Maintain the same temperature and humidity during the life of the installation
(between 65-95°F) with a maximum RH of 65% for 48 hours before and during
installation, as well as for 72 hours afterward.
Spread adhesive uniformly using a trowel or roller. Adhesive ridges should be
of sufficient height to achieve full coverage of the substrate and the deepest
recesses in the back of the flooring material.
When installing over a porous substrate, place flooring into semi-wet
adhesive for a permanent bond or allow adhesive to dry and become tacky to
the touch for a releasable bond. When installing over a non-porous substrate,
allow adhesive to dry and become tacky before placing the flooring.
Setup time will vary slightly with temperature, humidity and porosity of
substrate.
Curing
High temperature and low humidity will cause the adhesive to cure faster.
After installation, restrict foot traffic and moving of heavy objects for 24-48
hours to allow adhesive to cure properly. Premature trafc can cause
installation failure.
Clean-up
Fresh adhesive – warm, soapy water.
Dried adhesive – use mineral spirits sparingly with a clean, white cotton cloth.
DO NOT POUR DIRECTLY ONTO FLOORING.
6. AVAILABILITY
Packaging
4 U.S. gallon Plastic Pail 7350-4 075378735045
1 U.S. gallon Plastic Pail 7350-1 075378735014
1 U.S. quart Plastic Pail 7350-0 075378735008
7. WARRANTY
15-Year Moisture Control / 15-Year Direct Bond / 7-Year Double Bond
ROBERTS warrants that this product will be free from manufacturing defects
for 12 months from the date of manufacture, when applied in accordance with
ROBERTS’ instructions and industry standards. ROBERTS’ sole liability is to
either supply new product or refund the original purchase price. This limited
warranty excludes all other express warranties including the warranties
of merchantability for a particular use or purpose. Any implied warranties
arising by operation of law are limited to one year. ROBERTS will not be liable
for any incidental or consequential damages.
Visit www.robertsconsolidated.com for full warranty details.
8. MAINTENANCE
Not applicable.
9. TECHINCAL SERVICES
For technical assistance or installation questions not covered in this
document, please contact our Technical Services Department at
(706) 277-5294 or visit robertsconsolidated.com.
10. FILING SYSTEM
Division 9
11179
Q.E.P. Co., Inc.
1001 Broken Sound Parkway, NW
Boca Raton, FL 33487
www.qepcorporate.com
www.robertsconsolidated.com
Customer Service: (866) 435-8665
Technical Assistance: (905) 791-4444
Updated: November 27, 2018
ROBERTS
®
, GoldGuard
®
, and the e
®
logo are registered trademarks of Roberts Consolidated Industries, Inc. • Q.E.P.
®
is a registered trademark of Q.E.P. Co., Inc.
CRI Green Label +Plus
®
is a registered trademark of The Carpet and Rug Institute
LEED
®
, and its related logo, is a trademark owned by the U.S. Green Building Council
®
and is used with permission.
®
M
O
I
S
T
U
R
E
C
O
N
T
R
O
L
U
P
T
O
1
0
L
B
S
.
M
V
E
R
/
9
0
%
R
H
  • Page 1 1
  • Page 2 2

Roberts 7350-0 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI