The Cooper Lighting PD6-V142 is a versatile and energy-efficient lighting system designed for a wide range of applications. With its modular design, it offers the flexibility to customize the system to meet specific lighting needs. The PD6-V142 combines visually comfortable optics with energy efficiency and modularity. The fixture is composed of three key elements: reflector, socket adapter, and frame.

The reflector boasts equal 55° cutoff to lamp and lamp image. The low-iridescent clear reflector with white-painted self-flange is the standard option. The socket adapters provide modular flexibility and proper lamp orientation and quantity. The electronic ballasts are standard. The frames are dedicated to each aperture size and are compatible with different light sources like compact fluorescent, metal halide, and incandescent sources.

Cooper Lighting PD6-V142

The Cooper Lighting PD6-V142 is a versatile and energy-efficient lighting system designed for a wide range of applications. With its modular design, it offers the flexibility to customize the system to meet specific lighting needs. The PD6-V142 combines visually comfortable optics with energy efficiency and modularity. The fixture is composed of three key elements: reflector, socket adapter, and frame.

The reflector boasts equal 55° cutoff to lamp and lamp image. The low-iridescent clear reflector with white-painted self-flange is the standard option. The socket adapters provide modular flexibility and proper lamp orientation and quantity. The electronic ballasts are standard. The frames are dedicated to each aperture size and are compatible with different light sources like compact fluorescent, metal halide, and incandescent sources.

DESCRIPTION SPECIFICATION FEATURES
6
OPEN DOWNLIGHT
OPEN WALL WASH
CATALOG# : TYPE:
PD6-V142
42W TTT
Compact Fluorescent
6"OPEN DOWNLIGHT
6"OPEN WALL WASH
COOPER LIGHTING
ADV995023
26 3/8"
[671mm]
10 5/8"
[268mm]
12 7/8"
[327mm]
Top View
6 1/4"
[158mm]
5 3/4"
[146mm]
7"
[176mm]
8 7/8"
[225mm]
C
E
D
G
F
A
B
V142E=(1) 42, 32 or 26W Triple tube
lamp, multi voltage ballast.
6VC =6" Vertical Clear
6VWC =6" Vertical Open Wall Wash, Clear
6VBB =6" Vertical Black Baffle
6VWB =6" Vertical White Baffle
ORDERING INFORMATION
SAMPLE NUMBER: PD6-V142E-6VC
Order frame, socket adapter and reflector separately for a complete unit.
PD6
PD6
Reflector
V142E
Socket AdapterFrame
The Performance Downlight
System (PDS) combines visually
comfortable optics, energy
efficiency and modularity with
availability. Three key elements—
reflector, socket adapter and
frame—combine to form a feature-
packed luminaire.
PDS reflectors boast equal 55°
cutoff to lamp and lamp image.
Low-iridescent clear reflector with
white-painted self flange is
standard.
PDS socket adapters provide
modular flexibility and assure
proper lamp orientation and lamp
quantity to be used with each
reflector. Lamp positions lock into
place ensuring photometric
performance. Electronic ballasts are
standard.
PDS frames are dedicated to each
aperture size and are used for
compact fluorescent, metal halide
and incandescent sources. No Fuss
Bar Hangers™ speed installation of
frames, minimizing labor costs on
the job site.
A...Reflector
One-piece optical reflector
minimizes internal losses and light
leaks. 5/8" overlapping flange
provides gap-free aperture.
Standard finish is low-iridescent
clear with white painted self-flange.
Torsion spring mounting pulls
flange tight to ceiling.
Wall wash reflector utilizes
injection-molded GRUVI,
mechanically fastened to the
reflector.
B
...
Baffles
One-piece black or white baffle.
Upper specular reflector maximizes
light output. Self-flange of each is
painted white.
C
...
Socket Cap
One-piece metal cap. Positive
connection between cap and
reflector is provided by a twist-and-
lock mechanism. Multiple slots
allow for precise lamp positions.
D
...
Socket and Socket Adapter
4-pin G24q base with stainless
steel spring for positive retention
of 42, 32, and 26W triples. Guide
post inserts rejects two-pin bases
to ensure proper lamping. Multi-
voltage ballast accommodates
120V thru 277V.
E
...
Frame
Galvanized steel frame with
1/2" plaster lip is standard.
Accommodates ceilings up
to 2" (50mm) thick.
F
...
No Fuss Bar Hanger
Bar hanger locks to T-bar with a
screwdriver or pliers. Centering
mechanism allows consistent
centering of fixtures. 2 1/2"
vertical adjustment. Can be
used with 1/2" EMT
G
...
Junction Box
Galvanized with (6) 1/2" and
(2) 3/4" KOs.
Insulation Detector
Thermal protection deactivates unit
if improper lamp type or wattage is
used, or if insulation is placed too
close to the fixture.
Labels
CUL Iisted, damp location, IBEW
union made.
Energy Data
V142E
Lamp System Open
Voltage wattage : wattage circuit
Input 120V, 42W : 47.0W, 0.39A
120V, 32W : 34.5W, 0.30A
120V, 26W : 26.0W, 0.22A
277V, 42W : 47.0W, 0.13A
277V, 32W : 34.5W, 0.13A
277V, 26W : 26.0W, 0.09A
Power Factor: >.98
THD: <10%:
Sound Rating: A
Min Starting Temp.: -0°C (20°F)
10/11/2007
PHOTOMETRICS
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
PD6-V142
5'6"
6'6"
8'0"
10'0"
12'0"
14'0"
6'
7'
9'
11'
13'
15'6"
22
16
10
6
5
4
Cone of Light
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADV995023
Note: Specifications and Dimensions subject to change without notice.
Visit our website at www.cooperlighting.com
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
5'6"
6'6"
8'0"
10'0"
12'0"
14'0"
6'
7'
9'
11'
13'
15'6"
24
17
11
7
5
4
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
5'6"
6'6"
8'0"
10'0"
12'0"
14'0"
6'
7'
9'
11'
13'
15'6"
23
16
11
7
5
4
Cone of Light
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
Cone of Light
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
5'6"
6'6"
8'0"
10'0"
12'0"
14'0"
6'
7'
9'
11'
13'
15'6"
24
17
11
7
5
4
Cone of Light
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
Candela
10/11/2007
Candlepower
Candlepower Distribution Single Unit Foot-candles
Avg Luminance CD/SQ M
Downlight Degree Wall Washer
549
520
436
345
271
189
127
50
19
3
0
0
5
15
25
35
45
55
65
75
85
90
549
572
602
570
499
443
281
92
34
5
0
2’6” Distance from wall
(single fixture)
DD
1
2
3
4
5
6
7
8
9
0
I 1' 2' 3' 4' 5' 6'
8642111
20 17 9 4 2 1 1
19 17 10 6 3 2 1
14 14 9 6 3 2 1
10 10 7 5 3 2 2
7764322
5543322
4433221
3332221
2222211
Downlight
120
240
360
480
600
Wall Washer
250
500
750
250
500
750
300
600
900
300
600
900
80°
60°
70°
40°
50°
30°10° 20°30° 10°20°
Efficiency = 35.6%
Test No. 12136
PD6-V142E-6VWC
Lamp = 42W TTT
Candlepower Distribution
Spacing Criteria = 1.1
Efficiency =
57.7%
Test No. H22342
PD6-V142E-6VC
Lamp = 26W PLT
Lumens = 1800
Deg. Downlight Wall Washer
45 29019 39074
55 22182 30555
65 7379 13577
75 4338 8193
85 2862 3578
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
0
1
2
18
232
440
637
701
685
663
Candelas
Candlepower Distribution
Spacing Criteria = 1.1
Efficiency = 46.9%
Test No. H22330
PD6-V142E-6VC
Lamp = 32W PLT CFL
Lumens = 2400
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
4
14
62
264
476
619
686
694
685
Candelas
Candlepower Distribution
Spacing Criteria = 1.1
Efficiency = 46.1%
Test No. H22331
PD6-V142E-6VWB
Lamp = 32W PLT CFL
Lumens = 2400
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
7
24
30
42
204
429
631
754
756
721
Candelas
Candlepower Distribution
Spacing Criteria = 1.1
Efficiency = 41.7%
Test No. H22332
PD6-V142E-6VBB
Lamp = 32W PLT CFL
Lumens = 2400
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
0
4
5
18
184
414
621
753
752
711
Candelas
  • Page 1 1
  • Page 2 2

Cooper Lighting PD6-V142 User manual

Type
User manual

Cooper Lighting PD6-V142

The Cooper Lighting PD6-V142 is a versatile and energy-efficient lighting system designed for a wide range of applications. With its modular design, it offers the flexibility to customize the system to meet specific lighting needs. The PD6-V142 combines visually comfortable optics with energy efficiency and modularity. The fixture is composed of three key elements: reflector, socket adapter, and frame.

The reflector boasts equal 55° cutoff to lamp and lamp image. The low-iridescent clear reflector with white-painted self-flange is the standard option. The socket adapters provide modular flexibility and proper lamp orientation and quantity. The electronic ballasts are standard. The frames are dedicated to each aperture size and are compatible with different light sources like compact fluorescent, metal halide, and incandescent sources.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI