9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
FLAME
TWIN
STATUS
L1
XFMR
EAC
COOL
HEAT
M3
M2
M1
HUM
NEUTRALS
EAC
COM
3 AMP FUSE
BLOWER OFF
24V
HUM
1
2
3
4
5
6
7
8
9
4
5
6
1
2
3
240V 208V
24V
COM
11
22
RC
HI LO
PRIMARY
GAS VALVE
C
L W2Y2
R C
Y1 G W1
54321
54321
VARIABLE
SPEED
BLOWER
MOTOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
13
R
R
W
W
11 7 5
7654321
RC YGW
R
S
C
R
S
C
CHF
TO 208/230 VAC
POWER SUPPLY
FLAME ROLL-OUT SWITCH LIMIT SWITCH
FLAME
SENSOR
PRESSURE
SWITCH
INDUCER MOTOR
IGNITOR
VARIABLE SPEED CONTROL
BOARD
LOW PRESSURE
SWITCH
HIGH
PRESSURE
SWITCH
L1L2
T1T2
RED
ECONOMIZER JUMPER
HARNESS ASSY. 8-WIRE
ECONOMIZER
PLUG
ECONOMIZER PLUG
AIR SENSOR
TO DISCHARGE RED
RED
BLACK
GREEN
WHITE
YELLOW
RED
ORANGE
ORANGE
YELLOW
BROWN
BROWN
BROWN
BLACK
GRAY
BLUE
BLUE
BLUE
TERMINAL BLOCK
OUTDOOR
FAN MOTOR
COMPRESSOR
DUAL
CAPACITOR
CONTACTOR
BROWN
BROWN
GROUND
RED
WHITE
WHITE
RED
GRAY
RED
YELLOW
YELLOW / BLACK
BLACK / WHITE
BLACK
YELLOW
BLACK
BLACK
TRANSFORMER
GREEN
YELLOW / BLACK
BLACK
YELLOW / BLACK
YELLOW
WHITE
GREEN
RED
ORANGE
ORANGE
BROWN
BLUE
BLUE
YELLOW
YELLOW
YELLOW
RED
RED
RED
ORANGE
BLUE
YELLOW
BLACK
GRAY
GREEN
YELLOW
BLUE BLUE
CONTROL WIRING LEADS
Refer to Installation
Instructions for Connection to
Indoor Thermostat
Note: See Installation instructions for specific
blower speed setting.
P1
Pin Numbers
3 2 1
6 5 4
9 8 7
P2
Pin Numbers
3 2 1
6 5 4
(YELLOW) (RED)
BROWN
GREEN
YELLOW
BLACK
BLUE
WHITE
GREEN
YELLOW
YELLOW
BLUE
BLACK
RED
BROWN
208/230 Volt Single PhasePackaged Two Stage Heat/Two Stage Electric Air Conditioner 60Hz
WIRING DIAGRAM
NOTES:
1. Disconnect power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
4. If any of the original wire as supplied with the furnace
must be replaced, it must be replaced with wiring
material having a temperature rating of at least 105°C.
NOTES:
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V
a la terre.
5. For supply wire ampacities and overcurrent protection,
see unit rating plate.
6. Ensure that wires from the blower remain connected to
the board thermostat terminals after making the field
thermostat connections.
7. Wiring shown for single stage operation. For two stage
operation move Brown wire from low side of Gas Valve
to W2 on the Terminal Block and remove Jumper from
W1 to W2.
708570B
(Replaces 708570A)
1206
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
FAULT CONDITION STATUS LIGHT (RED)
Limit Circuit Open 1 Flash
Pressure Switch Stuck Open with Inducer On 2 Flashes
Pressure Switch Stuck Open with Inducer Off 3 Flashes
Ignition Failure (Check Ground) 4 Flashes
230 VAC & Neutral Reversed nd 5 Flashes
False Flame or Gas Relay Shorted Continuous Flash
FAULT CONDITION STATUS LIGHT (YELLOW)
Low Flame Sensor Signal Continuous Flash
¢708570+¤