Danfoss 3060 Installation & User's Instructions

  • Hello! I am an AI chatbot trained to assist you with the Danfoss 3060 Installation & User's Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
3060
Installation & User Instructions
electro-mechanical
programmer for controlling
heating & hot water
This product complies with the following EC Directives:
Electro-Magnetic Compatibility Directive.
(EMC) (2004/108/EC)
Low Voltage Directive.
(LVD) (2006/95/EC)
2
INDEX
Index
Installation
Productspecication 3
Installation 4
Wiring 4-5
User
Yourprogrammer 6
Programmingtheunit 6-7
Settingtheclock 7
Usingtheprogrammer 8-9
Contactdetails 12
3
Please Note:
This product should only be installed by a qualied
electrician or competent heating installer, and
should be in accordance with the current edition of
the IEEE wiring regulations.
Specication
Power supply 230±15%Vac,50/60Hz
Switchaction 2xSPST,type1B
Switchrating
Max264Vac,50/60Hz,3(1)A
Timingaccuracy ±1min/month
Enclosurerating IP30
Max.ambienttemperature 55°C
Dimensions,mm(W,H,D) 102 x 210 x 60
Designstandard EN60730-2-7
Construction Class1
ControlPollutionSituation Degree 2
RatedImpulseVoltage 2.5kV
BallPressureTest 75°C
Product specication
Installation Instructions
Specication
4
3060
Installation
Installation
1. Removelowersettingdial.Setallfourtappetstotop
ofupperdial.Unscrew4BAscrewandremoveouter
case.
2. Slackentwoscrewssecuringplug-inmoduleto
backplateandseparatemodulefrombackplateby
pullingupwards.
3. Fixbackplatetowall(3holexing).
4. Referringtowiringdiagramsbelowandopposite
makeelectricalconnectionsasshown(asapplicable).
Thediagramsindicatethatterminals3and5arenot
internallyconnectedtotheprogrammerandmay
thereforebeusedassparewiringterminalsifrequired.
5. Easeofinstallationcanbeachievedbytheuseofthe
DanfossRandallWiringCentrewhichisobtainable
frommostBuildersMerchantsandDistributors.
NOTE: If a Wiring Centre is used follow the
installation instructions included with that unit and
not the following wiring diagrams.
6. Securecablecoresundercableclamp.
5
Wiring
Wiring
12345678910
S/L
LN
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Hot Water)
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Heating)
Flying lead
Flying
lead
2
4
1
(N)
12
3
4
5
6
7
Danfoss Randall
ATC Cylinder Stat
2
3
1
3 core
2 core3 core
Danfoss
Randall
RMT230
Room Stat
3060
Te rminals
Mains
Supply
N
L
2 core +
3 or 4 core
N
N
L
L
Boiler
Pump
Permanent line
supply for boiler
if required
12
3
4
5
6
7
2
4
1
N
L
Boiler
1
2
3
Danfoss Randall
ATC Cylinder Stat
Danfoss
Randall
RMT230
Room
Stat
N
L
Pump
3060
Te rminals
Mains
Supply
N
L
WIRING - FULLY PUMPED SYSTEM
WIRING - GRAVITY HOT WATER SYSTEM
NOTE: This unit is NOT suitable for use with fully motorised zone valves
requiring both ON and OFF electrical signals when used in the heating
circuit
12345678910
S/L
LN
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Hot Water)
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Heating)
Flying lead
Flying
lead
2
4
1
(N)
12
3
4
5
6
7
Danfoss Randall
ATC Cylinder Stat
2
3
1
3 core
2 core3 core
Danfoss
Randall
RMT230
Room Stat
3060
Te rminals
Mains
Supply
N
L
2 core +
3 or 4 core
N
N
L
L
Boiler
Pump
Permanent line
supply for boiler
if required
12
3
4
5
6
7
2
4
1
N
L
Boiler
1
2
3
Danfoss Randall
ATC Cylinder Stat
Danfoss
Randall
RMT230
Room
Stat
N
L
Pump
3060
Te rminals
Mains
Supply
N
L
WIRING - FULLY PUMPED SYSTEM
WIRING - GRAVITY HOT WATER SYSTEM
NOTE: This unit is NOT suitable for use with fully motorised zone valves
requiring both ON and OFF electrical signals when used in the heating
circuit
6
User Instructions
Your programmer
The3060programmerallowsyoutoswitchyourhotwater
andheatingonandoffattimesthatsuityou.
Fourtappetsonthetimingdialletyoudecidewhenyou
wantyourhotwaterandheatingtocomeonandgooff
eachday.Theprogrammerprovides2ONtimesand2
OFFtimesperday.
Usingthelowerdialyoucanchoosehowyoucontrolyour
HeatingandHotWater,eitheratthesettimes,constantly
ON,constantlyOFF(eachindifferentcombinations).
Duringthesummerthecentralheatingcanbeturnedoff,
whilststillcontrollingthehotwateratthesettimes.
Your Programmer & Programming the unit
Programming the unit
TherearefourTAPPETSonyourtimingdial,tworedand
twoblue:
o the redtappetsaretheON switches
o the bluetappetsaretheOFF switches
1. Holdthecentralblack&
silverknobwithonehand
andmovetheredtappet
marked‘Aclockwise to
thetimeyouwantyour
HEATING/HOTWATERto
switch oninthemorning.
NB.youmayndthetappetsquitestiff,soyoumay
havetopushthemquitermlytomovethem.
7
Setting the clock
2 Stillholdingthecentralknob,movethebluetappet
marked‘B’tothetimeyouwantyourHEATING/HOT
WATERtoswitchoffinthemorning.
3 Youcansetyourothertwotappetsinthesameway
tosetyourHEATING/HOTWATERfortheafternoon
orevening.
EXAMPLE
(NB.Clockisin24hourmode)
IfyouwantyourheatingandhotwaterONbetween
7amand10amandONagainbetween5pmand
11pm,settappetsasfollows:
Aat1stONtime=7
Bat1stOFFtime=10
Cat2ndONtime=17
Dat2ndOFFtime=23
Setting the Clock
o Turnthedialclockwise
until the correct time is
lined up with the dot
labelledTIME
NB.clockisin24hour
mode
REMEMBER
You will have to reset the time after a power
cut and also when the clocks change in
Spring and Autumn
!
8
Using the Programmer
Theselectorswitchisusedtoselecthowthe3060controls
yourhotwaterandheating.Theheatingandhotwatercanbe
operatedtogetherinvariouscombinations,orthewatercan
becontrolledonitsown(i.e.duringthesummerwhenonly
hotwaterisrequired).
Therearesixpositionsintowhichtheselectorswitchmay
beset.
1 - H OFF / W OFF
BothHeatingandHotWaterwillremainOFFuntilyou
changethesetting.
2 - H TWICE / W TWICE
InthispositiontheHeatingandHotWaterwillboth
comeonandgooffaccordingtothetimesyouhave
programmed(ONatA,OFFatB,ONatC,OFFatD).
3-H ONCE / W ONCE
ThissettingoverridestappetsBandC,soboth
HeatingandHotWaterwillswitchONatthetime
markedbytappetAandwillstayonuntilthetime
markedbytappetD.Bothserviceswillthenswitch
OFFuntil‘Athenextday.
Using the programmer
H+W
ON
H+W
OFF
H - TWICE
W - ONCE
H - ONCE
W - ONCE
H - TWICE
W - TWICE
H - OFF
W - TWICE
9
Using the programmer
4 - H ON / W ON
Thisisthe‘CONSTANT’positionandtheprogrammer
willremainpermanentlyONforbothHeatingandHot
Water,irrespectiveofthepositionofthetappets.
5 - H TWICE / W ONCE
Inthispositiontheheatingwillcomeonandgooff
accordingtothetimesyouhaveprogrammed(ONat
A,OFFatB,ONatC,OFFatD).
TheHotWaterwillcomeonatAandstayonuntilD.
6 - H OFF / W TWICE
InthispositiontheHeatingwillbepermanentlyOFF
andtheHotWaterwillcomeonandgooffaccordingto
thetimesyouhaveprogrammed(ONatA,OFFatB,
ONatC,OFFatD).
Note:
If hot water is required all day with the heating shut
off (i.e. heat off, water once)
o Turntheselectorswitchto‘Htwice/Wonce’and
turndowntheroomthermostattoitslowest
setting.
If constant hot water is required with heating off (i.e.
heat off, water on)
o Turntheselectorswitchto‘Hon/Won’andturn
theroomthermostattoitslowestsetting.
10
11
Danfoss Ltd
AmpthillRoad
Bedford
MK42 9ER
Tel:01234364621
Fax:01234219705
Still having problems?
Callyourlocalheatingengineer:
Name:
Tel:
Visitourwebsite:
www.heating.danfoss.co.uk
Emailourtechnicaldepartment:
Callourtechnicaldepartment
0845 121 7505
(8.45-5.00Mon-Thurs,8.45-4.30Fri)
For a large print version of these
instructions please contact the Marketing
Services Department on 0845 121 7400.
PartNo.7485v0306/08
/