Lightolier Paraplus PPH1G6FW132 User manual

Category
Flat panel ceiling mounts
Type
User manual

This manual is also suitable for

Features
Direct/indirect louver appearance with soft contoured interior.
6 cell flat white louver with lens overlay.
Air return models meet UL 1598, Paragraph 12.2.2.3 requirements.
60.2% efficient (2 lamp T8 W lens).
63.6% efficient (2 lamp T8 V lens).
Only 4-31/32" deep.
Same fixture fits both G and T ceiling types.
Fits flush to face of slot grid (T) ceiling.
Static, optional.
Louver hinges from either side.
End of louver gasketed to eliminate light leak.
Can be continuous row mounted.
Wiring access plate standard.
Meets NYC Code requirements.
Construction to meet Chicago Plenum requirement is available.
Mounting Methods Dimensions
Paraplus PPH1G6FW132 or 232
Page 1 of 2 Direct/Indirect 1' x 4' Recessed Fluorescent
6 Cell White Parabolic Louver With Lens Overlay, 1 Lamp or 2 Lamp T8
exposed slot t-grid ceiling
Acoustical
material
by others
1-7/8"
max.
Exposed T-bar
by others
9/16"
24"
air return flow
louver hinges
from either side
hold-down clips (1 at each end)
exposed t-grid ceiling
Exposed T-bar
by others
1-1/2"
max.
Acoustical
material
by others
15/16" *
24"
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group Section 5/Folio M10-12 Rev. A
Lightolier is a Philips group brand
05/08
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group Section 5/Folio M10-12 Rev. A
Job Information Type:
-
Lightolier is a Philips group brand
Ordering Information
Explanation of Catalog Number. Example: PPH1G6FW232UNVHI
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK91X4.
Electrical Wiring Options: Consult factory.
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .67. To reduce glare the average brightness at 65° shall not exceed
1941 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 63.5%.
Materials: Chassis parts are die-formed 20 gauge steel. Housing has all edges
turned for safe-handling.
Finish: Chassis exterior – baked white powder coated polyester enamel.
Cavity – baked white powder coated polyester enamel. Louver – baked white
powder coated polyester enamel, minimum 86% reflectance. Rust preventative
undercoating.
Specifications (continued)
Overlay: M=Matte white acrylic .040 thick. W=Pattern 20 prismatic .140 thick. O=K20 with white
overlay. V=.095 acrylic pattern 12.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
Body Style:
H = Air Return
S = Static
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
6
Number
of Cells:
1 row of 6 cells
32
Lamp:
(By Others)
32=T8
(Nominal 48")
Ballast Type:
<20THD <10THD
1 or 2 Lamp Elec. T8 SO * H
I *
LOL Dimming T8 PS *
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
I
Ballast Code.
0.0 45.0 90.0 FLUX
0 1701 1701 1701
5 1673 1686 1699 160
15 1583 1583 1583 447
25 1444 1393 1376 646
35 1235 1154 1146 734
45 920 829 726 631
55 550 419 356 404
65 347 220 198 251
75 183 106 91 125
85 36 27 25 32
90 000
Model No. PPH1G6FW232UNVHI
LER = FP - 46.6 IW - 64.1 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $5.15
Report Number: G01076
Catalog Number: PPH1G6FW232120SO
Lamps: (2) F32/T8
Luminaire: Paraplus with white painted
interior, white painted 6 cell parabolic
louver with .140 prismatic overlay
Ballast: Howard Industries E3-32/120
Report is based on 2850 Lumens per lamp.
Efficiency: 60.2%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.1
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.920 10.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3935. 3545. 3105.
55 2900. 2209. 1877.
65 2483. 1574. 1417.
75 02138. 1239. 1063.
85 01249. 937. 867.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01666462605957585755
02615754545149525048
03575147484542474441
04524641444037423936
05494237403633393532
06453833363229353229
07423530332926322926
08393227312724302623
09372925282421282421
10 35 27 23 26 22 20 26 22 20
ZONE LUMENS % LAMP % FIXT
00-030 1253 22.0 36.5
00-040 1987 34.9 57.9
00-060 3021 53.0 88.1
00-090 3429 60.2 100.0
90-180 0000 0.0 000.0
00-180 3429 60.2 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
Paraplus PPH1G6FW132 or 232
Page 2 of 2 Direct/Indirect 1' x 4' Recessed Fluorescent
6 Cell White Parabolic Louver With Lens Overlay, 1 Lamp or 2 Lamp T8
F
Flat White
Louver
and Body
Lamp
Quantity
1=1 Lamp
2=2 Lamp
Paraplus
PP
Standard Paraplus
PN
For NYC Code – Local 3 Manufactured
Lens
Overlay:
M =Matte White
Acrylic .040
Thick
W =Pattern 20
Prismatic
.140 Thick
O =K20 with
White
Overlay
V =.095 Pattern
12
Model No. PPH1G6FV232UNVHI
LER = FP - 56.1 IW - 56.9 BF - 0.88
Comparative yearly lighting energy cost per
1000 lumens = $4.28
Report Number: G2007095
Catalog Number: PPH1G6FV232UNVHI
Lamps: (2) F32/T8
Luminaire: Paraplus with white painted
interior, white painted 6 cell parabolic
louver with .095 prismatic overlay.
Ballast: B232IUNVHP-B (Triad)
Report is based on 2850 Lumens per lamp.
Efficiency: 63.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.1
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 47.040 11.040
0.0 45.0 90.0 FLUX
0 1612 1612 1612
5 1582 1600 1613 152
15 1488 1511 1526 426
25 1341 1348 1340 620
35 1155 1119 1065 697
45 939 843 790 660
55 709 573 540 534
65 464 330 275 343
75 218 134 119 158
85 40 31 29 36
90 433
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3962. 3557. 3333.
55 3688. 2981. 2809.
65 3276. 2330. 1941.
75 2513. 1545. 1372.
85 1369. 1061. 993.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01706765636160615958
02645955565350545149
03595348504643484542
04544742454137434037
05504237403633393532
06463833373229363229
07433530342926332926
08403227312623302623
09383025282421282421
10 35 27 22 26 22 19 26 24 19
ZONE LUMENS % LAMP % FIXT
00-030 1197 21.0 33.0
00-040 1894 33.2 52.2
00-060 3088 54.2 85.2
00-090 3625 63.6 100.0
90-180 0000 00.0 000.0
00-180 3625 63.6 100.0
ZONAL LUMEN SUMMARY
  • Page 1 1
  • Page 2 2