Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
1
CONTENTS
Insideyouwillfindmanyhelpfulhintsonhowtouseandmaintainyourairconditioner
properly.Justalittlepreventivecareonyourpartcansaveyouagreatdealoftime
andmoneyoverthelifeofyourairconditioner. You'llfindmanyanswerstocommon
problemsinthechartoftroubleshootingtips.Ifyoureviewourchartof Troubleshooting
Tipsfirst,youmaynotneedtocallforserviceatall.
Contacttheauthorisedservicetechnicianforrepairormaintenanceofthisunit.
Contacttheinstallerforinstallationofthisunit.
Theairconditionerisnotintendedforusebyyoungchildrenorinfirmpersons
withoutsupervision.
Youngchildrenshouldbesupervisedtoensurethattheydonotplaywiththeair
conditioner.
Ifthepowercordistobereplaced,replacementworkshallbeperformedby
authorisedpersonnelonly.
Installationworkmustbeperformedinaccordancewiththenationalwiring
standardsbyauthorisedpersonnelonly.
!
CAUTION
Read ThisManual
1
1.SAFETY PRECAUTIONS..................................................................2
2.IMPORTANTSAFETY INSTRUCTIONS..........................................4
3.NORMAL SOUNDS...........................................................................5
4. AIRCONDITIONERFEATURES.......................................................5
5.INSTALLATIONINSTRUCTIONS......................................................10
6.CARE ANDCLEANING....................................................................14
7.TROUBLESHOOTINGTIPS...............................................................15
Contact an authorized service technician for repair or maintenance of this unit.
Contact an authorized installer for installation of this unit.
If the power cord needs to be replaced, replacement work shall be performed by
authorized service personnel only.
Installation work must be performed in accordance with the national and local
electric codes and must be performed by authorized personnel only.
19
20
Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual
4
IMPORTANTSAFETY INSTRUCTIONS
Besuretheelectricalserviceisadequateforthemodelyouhave
chosen. Thisinformationcanbefoundontheserialplate,which
islocatedonthesideofthecabinetandbehindthegrille.
Besuretheairconditionerisproperlygrounded. Tominimize
shockandfirehazards,propergroundingisimportant. Thepower
cordisequippedwithathree-pronggroundingplugforprotection
againstshockhazards.
Yourairconditionermustbeusedinaproperlygroundedwall
receptacle.Ifthewallreceptacleyouintendtouseisnotadequately
groundedorprotectedbyatimedelayfuseorcircuitbreaker,
haveaqualifiedelectricianinstalltheproperreceptacle.
Ensurethereceptacleisaccessibleaftertheunitinstallation.
Donotrunairconditionerwithoutsideprotectivecoverinplace.
Thiscouldresultinmechanicaldamagewithintheairconditioner.
Donotuseanextensioncordoranadapterplug.
WARNING
Foryoursafety
Donotstoreorusegasolineorotherflammablevaporsandliquidsin
thevicinityofthisoranyotherappliance.
Avoidfirehazardorelectricshock.Donotuseanextensioncordoran
adaptorplug.Donotremoveanyprongfromthepowercord.
WARNING
ElectricalInfor mation
NOTE Forsomemodels,thepower
supplycordwiththisairconditioner
containsacurrentdetectiondevice
designedtoreducetheriskoffire.
PleaserefertothesectionOperation
ofCurrentDevicefordetails.
Intheeventthatthepowersupply
cordisdamaged,itcannotbe
repaired-itmustbereplacedwitha
cordfromtheProductManufacturer.
,
,
Donot,underany
circumstances,cut,
remove,orbypass
thegroundingprong.
Powersupplycord
with3-pronggroundingplug
andcurrentdetectiondevice
Operationof Cur rentDevice
(Applicabletotheunitadoptscurrentdetectiondeviceonly)
Thepowersupplycordcontainsacurrentdevicethatsensesdamagetothepowercord. Totestyourpower
supplycorddothefollowing:
1.Pluginthe AirConditioner.
2. Thepowersupplycordwillhave TWObuttonsontheplughead.Pressthe TEST button,youwillnoticea
clickastheRESET buttonpopsout.
3.PresstheRESET button,againyouwillnoticeaclickasthebuttonengages.
4. Thepowersupplycordisnowsupplyingelectricitytotheunit.(Onsomeproductsthisitalsoindicatedby
alightontheplughead.)
Donotusethisdevicetoturntheunitonoroff.
AlwaysmakesuretheRESET buttonispushedinforcorrectoperation.
Thepowersupplymustbereplacedifitfailsresetwheneitherthe TEST buttonispushed,oritcannotbe
reset. A newonecanbeobtainedfromtheproductmanufacturer.
Ifpowersupplycordisdamaged,itcannotberepaired.ItMUST bereplacedbyone
NOTES:
obtainedfromthe
productmanufacturer.
4
Please refer to the section “Operation
of Current Device” for details.
IMPORTANTSAFETY INSTRUCTIONS
Besuretheelectricalserviceisadequateforthemodelyouhave
chosen. Thisinformationcanbefoundontheserialplate,which
islocatedonthesideofthecabinetandbehindthegrille.
Besuretheairconditionerisproperlygrounded. Tominimize
shockandfirehazards,propergroundingisimportant. Thepower
cordisequippedwithathree-pronggroundingplugforprotection
againstshockhazards.
Yourairconditionermustbeusedinaproperlygroundedwall
receptacle.Ifthewallreceptacleyouintendtouseisnotadequately
groundedorprotectedbyatimedelayfuseorcircuitbreaker,
haveaqualifiedelectricianinstalltheproperreceptacle.
Ensurethereceptacleisaccessibleaftertheunitinstallation.
Donotrunairconditionerwithoutsideprotectivecoverinplace.
Thiscouldresultinmechanicaldamagewithintheairconditioner.
Donotuseanextensioncordoranadapterplug.
WARNING
Foryoursafety
Donotstoreorusegasolineorotherflammablevaporsandliquidsin
thevicinityofthisoranyotherappliance.
Avoidfirehazardorelectricshock.Donotuseanextensioncordoran
adaptorplug.Donotremoveanyprongfromthepowercord.
WARNING
ElectricalInfor mation
NOTE Thepowersupplycordwith
thisairconditionercontainsacurrent
detectiondevicedesignedtoreduce
theriskoffire.
PleaserefertothesectionOperation
ofCurrentDevicefordetails.
Intheeventthatthepowersupply
cordisdamaged,itcannotbe
repaired-itmustbereplacedwitha
cordfromtheProductManufacturer.
,
,
Operationof Cur rentDevice
Thepowersupplycordcontainsacurrentdevicethatsensesdamagetothepowercord. Totestyourpower
supplycorddothefollowing:
1.Pluginthe AirConditioner.
2. Thepowersupplycordwillhave TWObuttonsontheplughead.
Pressthe TEST button,youwillnoticeaclickastheRESET
buttonpopsout.
3.PresstheRESET button,againyouwillnoticeaclickasthebutton
engages.
4. Thepowersupplycordisnowsupplyingelectricitytotheunit.
(Onsomeproductsthisitalsoindicatedbyalightontheplughead.)
Donotusethisdevicetoturntheunitonoroff.
AlwaysmakesuretheRESET buttonispushedinforcorrectoperation.
Thepowersupplymustbereplacedifitfailsresetwheneitherthe TEST buttonispushed,oritcannotbe
reset. A newonecanbeobtainedfromtheproductmanufacturer.
Ifpowersupplycordisdamaged,itcannotberepaired.ItMUST bereplacedbyone
NOTES:
obtainedfromthe
productmanufacturer.
4
TEST
RESET
Plugin&
pressRESET
NOTE:Someplugshave
buttonsonthetop.
Donot,underany
circumstances,cut,
remove,orbypass
thegroundingprong.
Powersupplycord
with3-pronggroundingplug
andcurrentdetectiondevice
NORMAL SOUNDS
AIRCONDITIONERFEATURES
SoundofRushing Air
Atthefrontoftheunit,youmay
hearthesoundofrushingair
beingmovedbythefan
HighPitchedChatter
Highefficiencycompressors
mayhaveahighpitchedchatter
duringthecoolingcycle.
Gurgle/Hiss
Gurglingorhissingnoisemay
beheardduetorefrigerant
passingthroughevaporator
duringnormaloperation.
PingingorSwitching
Dropletsofwaterhittingcondenser
duringnormaloperationmaycause
pingingorswitchingsounds.
Beforeyoubegin,thoroughlyfamiliarizeyourselfwiththecontrolpanelandremoteasshownbelow
andallitsfunctions,thenfollowthesymbolforthefunctionsyoudesire. Theunitcanbecontrolled
bytheunitcontrolaloneorwiththeremote.
Vibration
Unitmayvibrateandmakenoise
becauseofpoorwallorwindow
constructionorincorrectinstallation.
ELECTRONICCONTROLOPERATINGINSTRUCTIONS
ADJUSTS
TEMPERATURE
ORTIME
ADJUSTS
TEMPERATURE
ORTIME
DISPLAYS
TEMPERATURE
ORTIME
ACTIVATES
TIMER
CHECKFILTER
RESETBUTTON
SETSMODE
ENERGY
SAVERMODE
SLEEP MODE
CLEAN AIRMODE
(onsomemodels)
SETFANSPEED
TURNSUNIT
ONOROFF
UNITCONTROL
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
5
FOLLOWMEINDICATOR
(onsomemodels)
Beforeusingyourairconditioner,pleaseread
thismanualcarefullyandkeepitforfuturereference.
WINDOW/WALL TYPE
ROOM AIRCONDITIONER
-
MULTI-STEPSPEEDELECTRONICCONTROL
THIS AIRCONDITIONERISEQUIPPEDWITH A NEWINDUSTRY
STANDARDPOWERSUPPLY CORDWITH A TEST-RESETFUNCTION
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
5
Unit may vibrate and make noise
because of poor wall or window
construction or incorrect installation.
Swishing
swishing
Normal sounds
Sound of Rushing Air
At the front of the unit, you may
hear the sound of rushing air
being moved by the fan
High Pitched Chatter
High efficiency compressors
may have a high pitched chatter
during the cooling cycle.
Gurgle/Hiss
Gurgling or hissing noise may
be heard due to refrigerant
passing through evaporator
during normal operation.
Pinging or Switching
Droplets of water hitting condenser
during normal operation may cause
pinging or switching sounds.
Before you begin, thoroughly familiarize yourself with the control panels as shown below and all the
functions, then follow the symbol for the functions you desire. The unit can be controlled by the
unit control alone or with the remote controller.
Vibration
Unit may vibrate and make noise
because of poor wall or window
construction or incorrect installation.
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
Exhaust Selector
Sets Mode
Temp./Timer
Adjustment
Energy Saver
Mode
Activates Timer
Sleep Mode
Activates Check
Filter
Sets Fan
Speed
Turns Unit
On/ Off
Remote Signal
Receptor
6
AIR CONDITIONER FEATURES
EXHAUST
Closed
Open
MODE
ENERGY
SAVER
SLEEP
CLEAN
UP
DOWN
FAN
ON/
OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
Auto
Cool
Dry
Fan
ON
OFF
S
EXHAUST
Closed
Open
MODE
ENERGY
SAVER
SLEEP
CLEAN
AIR
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
Auto
Cool
Dry
Fan
ON OFF
S
Clean air mode
(on some models)
Follow me
Indicator
(on some models)
EXHAUST
Closed
Open
MODE
SLEEP
CLEAN
AIR
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
Auto
Cool
Dry
Fan
ENERGY
SAVER
On Off
S
Unit control panel(1)
Unit control panel(2)
Before you begin, thoroughly familiarize yourself with the control panel as shown below and all
its functions, then follow the symbol for the functions you desire. The unit can be controlled by
the unit control alone or with the remote.
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
7
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
DOTHIS:
Tochooseoperatingmode,presstheMode
button.Eachtimeyoupressthebutton,amode
isselectedinasequencethatgoesfrom Auto,
Cool,DryandFan. Theindicatorlightbeside
willbeilluminatedandremainedononcethe
modeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,
itstartsautomaticallyataspeedaccordingto
theroomtemperature.Iftheroomdoesnotget
toowarm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnot
desired,suchasforroomaircirculationorto
exhauststaleair(onsomemodels).
(Remembertoopentheventduringthisfunction,
butkeepitclosedduringcoolingformaximum
coolingefficiency.) Youcanchooseanyfan
speedyouprefer.
Duringthis function,thedisplaywillshowthe
actualroomtemperature
,notthesettemper-
atureasinthecoolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
DOTHIS:
Inthismode,thefanwillcontinuetorunfor
3minutesafterthecompressorshutsoff. The
fanthencyclesonfor2minutesat10minute
intervalsuntilthe roomtemperatureisabove
thesettemperature,atwhichtimethe
compressorturnsbackonandcoolingstars.
NOTE:
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewill
increaseby2degreesF30minutesafterthe
modeisselected. Thetemperaturewillthen
increasebyanother2degreesFafteran
additional30minutes. Thisnewtemperature
willbemaintainedfor7hoursbeforeitreturns
totheoriginallyselectedtemperature. This
endstheSleepmodeandtheunitwillcontinue
tooperateasoriginallyprogrammed. The
Sleepmodeprogramcanbecancelledatany
timeduringoperationbyagainpressingthe
Sleepbutton.
NOTE:
7
Timer
Temp.
S
Exhaust
closed
open
Mode
Energy
Saver
Tim er
on
Tim er
off
Timer
Temp.
Auto Cool Dry Fan
Timer
Temp.
S
Exhaust
closed
open
Mode
Energy
Saver
Tim er
on
Tim er
off
Timer
Temp.
Auto Cool Dry Fan
Timer
Temp.
Timer
Temp.
Sleep
Check
Filter
ON/
OFF
Follow
Me
Auto
Med
Low
High
Fan
Clean
Air
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sincethe
conditionedspaceisaclosedorsealedarea,
somedegreeofcoolingwillcontinue.
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
DOTHIS:
Tochooseoperatingmode,presstheMode
button.Eachtimeyoupressthebutton,amode
isselectedinasequencethatgoesfrom Auto,
Cool,DryandFan. Theindicatorlightbeside
willbeilluminatedandremainedononcethe
modeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,
itstartsautomaticallyataspeedaccordingto
theroomtemperature.Iftheroomdoesnotget
toowarm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnot
desired,suchasforroomaircirculationorto
exhauststaleair(onsomemodels).
(Remembertoopentheventduringthisfunction,
butkeepitclosedduringcoolingformaximum
coolingefficiency.) Youcanchooseanyfan
speedyouprefer.
Duringthis function,thedisplaywillshowthe
actualroomtemperature
,notthesettemper-
atureasinthecoolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
DOTHIS:
Inthismode,thefanwillcontinuetorunfor
3minutesafterthecompressorshutsoff. The
fanthencyclesonfor2minutesat10minute
intervalsuntilthe roomtemperatureisabove
thesettemperature,atwhichtimethe
compressorturnsbackonandcoolingstars.
NOTE:
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewill
increaseby2degreesF30minutesafterthe
modeisselected. Thetemperaturewillthen
increasebyanother2degreesFafteran
additional30minutes. Thisnewtemperature
willbemaintainedfor7hoursbeforeitreturns
totheoriginallyselectedtemperature. This
endstheSleepmodeandtheunitwillcontinue
tooperateasoriginallyprogrammed. The
Sleepmodeprogramcanbecancelledatany
timeduringoperationbyagainpressingthe
Sleepbutton.
NOTE:
7
Timer
Temp.
S
Exhaust
closed
open
Mode
Energy
Saver
Tim er
on
Tim er
off
Timer
Temp.
Auto Cool Dry Fan
Timer
Temp.
S
Exhaust
closed
open
Mode
Energy
Saver
Tim er
on
Tim er
off
Timer
Temp.
Auto Cool Dry Fan
Timer
Temp.
Timer
Temp.
Sleep
Check
Filter
ON/
OFF
Follow
Me
Auto
Med
Low
High
Fan
Clean
Air
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sincethe
conditionedspaceisaclosedorsealedarea,
somedegreeofcoolingwillcontinue.
Inthismode,thefanwillcontinuetorunfor3minutes
afterthecompressorshutsoff. Thefanthencycles
onfor2minutesat10minuteintervalsuntiltheroom
temperatureisabovethesettemperature,atwhich
timethecompressorturnsbackonandCoolingStars.
NOTE:
starts.
In the mode, the air conditioner will generally operate in
the form of a dehumidier to remove moisture from the air.
Since the conditioned space is a closed or sealed area,
some degree of cooling will continue.
Cool, Dry and Fan. The indicator light beside each
mode will be illumniated and remain on once the mode
is selected.
TO USE THE ENERGY
SAVER FEATURE:
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
DOTHIS:
Tochooseoperatingmode,presstheMode
button.Eachtimeyoupressthebutton,amode
isselectedinasequencethatgoesfrom Auto,
Cool,DryandFan. Theindicatorlightbeside
willbeilluminatedandremainedononcethe
modeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,
itstartsautomaticallyataspeedaccordingto
theroomtemperature.Iftheroomdoesnotget
toowarm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnot
desired,suchasforroomaircirculationorto
exhauststaleair(onsomemodels).
(Remembertoopentheventduringthisfunction,
butkeepitclosedduringcoolingformaximum
coolingefficiency.) Youcanchooseanyfan
speedyouprefer.
Duringthis function,thedisplaywillshowthe
actualroomtemperature
,notthesettemper-
atureasinthecoolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
DOTHIS:
Inthismode,thefanwillcontinuetorunfor
3minutesafterthecompressorshutsoff. The
fanthencyclesonfor2minutesat10minute
intervalsuntilthe roomtemperatureisabove
thesettemperature,atwhichtimethe
compressorturnsbackonandcoolingstars.
NOTE:
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewill
increaseby2degreesF30minutesafterthe
modeisselected. Thetemperaturewillthen
increasebyanother2degreesFafteran
additional30minutes. Thisnewtemperature
willbemaintainedfor7hoursbeforeitreturns
totheoriginallyselectedtemperature. This
endstheSleepmodeandtheunitwillcontinue
tooperateasoriginallyprogrammed. The
Sleepmodeprogramcanbecancelledatany
timeduringoperationbyagainpressingthe
Sleepbutton.
NOTE:
7
Timer
Temp.
S
Exhaust
closed
open
Mode
Energy
Saver
Tim er
on
Tim er
off
Timer
Temp.
Auto Cool Dry Fan
Timer
Temp.
S
Exhaust
closed
open
Mode
Energy
Saver
Tim er
on
Tim er
off
Timer
Temp.
Auto Cool Dry Fan
Timer
Temp.
Timer
Temp.
Sleep
Check
Filter
ON/
OFF
Follow
Me
Auto
Med
Low
High
Fan
Clean
Air
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sincethe
conditionedspaceisaclosedorsealedarea,
somedegreeofcoolingwillcontinue.
TO SELECT THE
OPERATING MODE:
Press the Mode
button.
DO THIS:
To choose operating mode, press the Mode
button. Each time you press the button, a mode
is selected in a sequence that goes from Auto,
Cool, Dry and Fan. The indicator light beside
will be illuminated and remained on once the
mode is selected.
NOTE:
To operate on Auto feature:
In this mode, the fan speed cannot be adjusted,
it starts automatically at a speed according to
the room temperature. If the room does not get
too warm, it will stay at Low speed.
To operate on Fan Only:
Use this function only when cooling is not
desired, such as for room air circulation or to
exhaust stale air(on some models).
(Remember to open the vent during this function,
but keep it closed during cooling for maximum
cooling efficiency.) You can choose any fan
speed you prefer.
During this function, the display will show the
actual room temperature, not the set temper-
ature as in the cooling mode.
TO USE THE ENERGY
SAVER FEATURE:
Press the button
DO THIS:
In this mode, the fan will continue to run for
3 minutes after the compressor shuts off. The
fan then cycles on for 2 minutes at 10 minute
intervals until the room temperature is above
the set temperature, at which time the
compressor turns back on and cooling stars.
NOTE:
SLEEP FEATURE:
Press Sleep
button
DO THIS:
In this mode the selected temperature will
increase by 2 degrees F 30 minutes after the
mode is selected. The temperature will then
increase by another 2 degrees F after an
additional 30 minutes. This new temperature
will be maintained for 7 hours before it returns
to the originally selected temperature. This
ends the Sleep mode and the unit will continue
to operate as originally programmed. The
Sleep mode program can be cancelled at any
time during operation by again pressing the
Sleep button.
NOTE:
8
AIR CONDITIONER FEATURES
MODE
ENERGY
SAVER
SLEEP
DOWN
ON/OFF
Follow me
Auto
Cool
Dry
Fan
S
MODE
ENERGY
SAVER
SLEEP
DOWN
ON/OFF
Follow me
Auto
Cool
Dry
Fan
S
MODE
ENERGY
SAVER
SLEEP
DOWN
ON/OFF
Follow me
Auto
Cool
Dry
Fan
S
To operate on Dry mode:
In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since
the conditioned space is a closed or sealed
area, some degree of cooling will continue.
TO SELECT THE
OPERATING MODE:
Press the Mode
button.
DO THIS:
To choose operating mode, press the Mode
button. Each time you press the button, a mode
is selected in a sequence that goes from Auto,
Cool, Dry and Fan. The indicator light beside
will be illuminated and remained on once the
mode is selected.
NOTE:
To operate on Auto feature:
In this mode, the fan speed cannot be adjusted,
it starts automatically at a speed according to
the room temperature. If the room does not get
too warm, it will stay at Low speed.
To operate on Fan Only:
Use this function only when cooling is not
desired, such as for room air circulation or to
exhaust stale air(on some models).
(Remember to open the vent during this function,
but keep it closed during cooling for maximum
cooling efficiency.) You can choose any fan
speed you prefer.
During this function, the display will show the
actual room temperature, not the set temper-
ature as in the cooling mode.
TO USE THE ENERGY
SAVER FEATURE:
Press the button
DO THIS:
In this mode, the fan will continue to run for
3 minutes after the compressor shuts off. The
fan then cycles on for 2 minutes at 10 minute
intervals until the room temperature is above
the set temperature, at which time the
compressor turns back on and cooling stars.
NOTE:
SLEEP FEATURE:
Press Sleep
button
DO THIS:
In this mode the selected temperature will
increase by 2 degrees F 30 minutes after the
mode is selected. The temperature will then
increase by another 2 degrees F after an
additional 30 minutes. This new temperature
will be maintained for 7 hours before it returns
to the originally selected temperature. This
ends the Sleep mode and the unit will continue
to operate as originally programmed. The
Sleep mode program can be cancelled at any
time during operation by again pressing the
Sleep button.
NOTE:
8
AIR CONDITIONER FEATURES
MODE
ENERGY
SAVER
SLEEP
DOWN
ON/OFF
Follow me
Auto
Cool
Dry
Fan
S
MODE
ENERGY
SAVER
SLEEP
DOWN
ON/OFF
Follow me
Auto
Cool
Dry
Fan
S
MODE
ENERGY
SAVER
SLEEP
DOWN
ON/OFF
Follow me
Auto
Cool
Dry
Fan
S
To operate on Dry mode:
In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since
the conditioned space is a closed or sealed
area, some degree of cooling will continue.
Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual
8
AIR CONDITIONER FEATURES (CONTINUED)
TIMER:AUTOSTART/
STOPFEATURE:
Press Timer
button
DOTHIS:
AIRCONDITIONERFEATURES(CONTINUED)
Firstpressthe Timerbutton,the Timeronindicator
lightilluminates.Itindicatesthe AutoStartprogram
isinitiated.
PressorholdtheLeftarroworRightarrowtochange
the Autotimeby0.5hourincrements,upto10hours,
thenat1hourincrementsupto24hours. Thecontrol
willcountdownthe timeremaininguntilstart.
Theselectedtimewillregisterin5secondandthe
systemwillautomaticallyrevertbacktodisplaythe
previoustemperaturesetting.
Performthesameproceduresasabovetosetthe
Timeroffsettings.
Pressthe Temp./Timeradjustbuttontoadjus
tthe
settingtimeto0.0atanytimewillcancelthe
AutoStart/Stopfunction.
NOTE:
CHECKFILTERFEATURE:
PressCheck
Filterbutton
DOTHIS:
Thisfeatureisaremindertocleanthe AirFilterfor
moreefficientoperation. TheLED(light)willillumi-
nateafter250hoursofoperation. Toresetafter
cleaningthefilter,presstheCheckFilterbuttonand
thelightwillgooff.
NOTE:
8
Timer
Temp.
S
Exhaust
closed
open
Mode
Energy
Saver
Tim er
on
Tim er
off
Timer
Temp.
Auto Coo l Dry Fan
Timer
Temp.
Timer
Temp.
Sleep
Check
Filter
ON/
OFF
Follow
Me
Auto
Med
Low
High
Fan
FOLLOWMEFEATURE:
(onsomemodels)
Lightflashing
NOTE:
ToactivatetheFollowMefeature,pointtheremote
controltowardstheunitandpresstheFollowMe
button. Thelightontheunitcontrolpanelwillpulse
toindicateitreceivedthesignal.Itwillcontinueto
sendthissignaluntilthefeatureisdeactivatedby
pressingtheFollowMebuttonagain.If theunitdoes
notreceivetheFollowMesignalduringany7minutes
interval,theunitwillbeeptoindicatetheFollowMe
modehasended. Thedisplayontheremotecontrol
indicatesthetemperatureattheremoteONLY.
Theactualtemperaturecanbedisplayedattheunit
bypressingt
heFanOnlymode.WhenintheCool
mode,theunitdisplayindicatesthesettemperature.
Thisfeaturecanbeactivatedfromtheremote
controlONLY.Theremotecontrolservesasa
remotethermostatallowingfortheprecise
temperaturecontrolatitslocation.
Timer
Temp.
Timer
Temp.
Slee p
Chec k
Filt er
ON/
OFF
Follow
Me
Auto
Med
Low
High
Fan
Clean
Air
Clean
Air
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
TIMER:AUTOSTART/
STOPFEATURE:
Press Timer
button
DOTHIS:
AIRCONDITIONERFEATURES(CONTINUED)
Firstpressthe Timerbutton,theindicatorlight
besideswordOnilluminates.Itindicatesthe Auto
Startprogramisinitiated.
PressorholdtheLeftarroworRightarrowtochange
the Autotimeby0.5hourincrements,upto10hours,
thenat1hourincrementsupto24hours. Thecontrol
willcountdownthetimeremaininguntilstart.
Theselectedtimewillregisterin5secondandthe
systemwillautomaticallyrevertbacktodisplaythe
previoustemperaturesetting.
TurningtheunitONorOFFatanytimewillcancelthe
AutoStart/Stopfunction.
NOTE:
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
CHECKFILTERFEATURE:
PressCheck
Filterbutton
DOTHIS:
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
M ed
H igh
Clean
Air
CLEANAIRFEATURE:
(onsomemodels)
PressClean
Airbutton
DOTHIS:
Thisfeatureisaremindertocleanthe AirFilterfor
moreefficientoperation. TheLED(light)willillumi-
nateafter250hoursofoperation. Toresetafter
cleaningthefilter,presstheCheckFilterbuttonand
thelightwillgooff.
NOTE:
PresstheClean Airbutton,theiongeneratorisener-
gizedandwillhelptoremovepollenandimpurities
fromtheair,andtraptheminthefilter.
NOTE:
8
Press the Timer button, the indicator light
the time by 0.5 hour increments, up to 10 hours
seconds and the
TIMER: AUTO START/
STOP FEATURE:
Press Timer
button
DO THIS:
First press the Timer button, the Timer on indicator
light illuminates. It indicates the Auto Start program
is initiated.
Press or hold the UP arrow or DOWN arrow to change
the Auto time by 0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24 hours. The control
will count down the time remaining until start.
The selected time will register in 5 second and the
system will automatically revert back to display the
previous temperature setting.
Perform the same procedures as above to set the
Timer off settings.
Press the Temp./Timer adjust button to adjust the
setting time to 0.0 at any time will cancel the
Auto Start/Stop function.
NOTE:
CHECK FILTER FEATURE:
Press Check
Filter button
DO THIS:
This feature is a reminder to clean the Air Filter for
more efficient operation. The LED(light) will illumi-
nate after 250 hours of operation. To reset after
cleaning the filter, press the Check Filter button and
the light will go off.
NOTE:
FOLLOW ME FEATURE:
(on some models)
Light flashing
NOTE:
To activate the Follow Me feature, point the remote
control towards the unit and press the Follow Me
button. The light on the unit control panel will pulse
to indicate it received the signal. It will continue to
send this signal until the feature is deactivated by
pressing the Follow Me button again. If the unit does
not receive the Follow Me signal during any 7 minutes
interval, the unit will beep to indicate the Follow Me
mode has ended. The display on the remote control
indicates the temperature at the remote ONLY.
The actual temperature can be displayed at the unit
by pressing the Fan Only mode. When in the Cool
mode, the unit display indicates the set temperature.
This feature can be activated from the remote
control ONLY. The remote control serves as a
remote thermostat allowing for the precise
temperature control at its location.
9
AIR CONDITIONER FEATURES
CLEAN
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
ON OFF
CLEAN
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
ON OFF
CLEAN
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
ON OFF
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
9
AIR CONDITIONER FEATURES (CONTINUED)
Additional things you should know
Now that you have mastered the operating procedure, here are more features in your control that
you should become familiar with.
The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on
quickly. This prevents overheating of the compressor and possible circuit breaker tripping.
The fan will continue to run during this time.
The control will maintain any set temperature within 2 F, between 60 F and 90 F degrees.
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.
To convert from one to the other, press and hold the UP and DOWN Temp/Timer buttons at the
same time, for 3 seconds.
Exhaust Control
This Exhaust Control allows the air conditioner to either circulate inside air (Closed) or exhaust
air to the outside (Open).
The Closed position is used when maximum cooling is desired. It may also be used for air re-
circulation without cooling when the air conditioner is set in any FAN position.
The Open position removes stale air from the room and exhausts it to the outside. Fresh air is
drawn in through normal passages in the home.
4-Way Louvers
The 4-Way air directional louvers allow you to
direct air flow up or down, left or right throughout
the room as needed. To adjust the air directional
louvers side-to-side, use the center handle as
you move it side-to-side.
10
Press the Clean Air button, the ion generator is
ener gized and will help to remove pollen and
impurities from the air, and trap them in the filter.
NOTE:
AIR CONDITIONER FEATURES
Press Check
Filter button
DO THIS:
CLEAN
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
ON OFF
EXHAUST
Closed
Open
MODE
ENERGY
SAVER
SLEEP
CLEAN
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
Auto
Cool
Dry
Fan
ON OFF
S
EXHAUST
Closed
Open
MODE
ENERGY
SAVER
SLEEP
CLEAN
UP
DOWN
FAN
ON/OFF
Follow me
CHECK
FILTER
TIMER
Auto Low Med
High
Auto
Cool
Dry
Fan
ON OFF
S
energized
compressor
F (1°C), between 6F (16°C) and 90°F (32°C) degress.
that
again
louvers side-to-side, use the lever until the desired
direction is obtained.
Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual
10
INSTALLATIONINSTRUCTIONS
ElectricalShockandPersonalInjuryHazard
10
NOTE: TheseinstructionsdescribeinstallationinatypicalwoodframedwindowwithawoodSLIDE
-BY sash,orinstallationinametalCASEMENT window.Modificationmaybenecessarywheninstalling
inwindowsmadedifferentlythanthoseshownintheseinstructions.
A highwidowaccessorykitisavailableforwindowheightsupto62(1575mm).
,
,
MeetingElectricalRequir ements
WARNING
!
Electricalgroundisrequiredonthisappliance.
DONOT groundtoagasline.
Ifcoldwaterpipeisinterruptedbyplastic,
non-metallicgaskets,orotherinsulating
materials,DONOT useforgrounding.
Checkwithaqualifiedelectricianifyouare
indoubtastowhethertheapplianceispro-
perlygrounded.
DONOT modifypowersupplycordplug.Ifit
doesnotfitoutlet,haveaproperoutlet
installedbyaqualifiedelectrician.
DONOT haveafuseintheneutralor
groundingcircuit. A fuseintheneutral,or
groundingcircuitcouldresultinanelectrical
shock.
DONOT u
seanextensioncordwiththis
appliance.
Failuretofollowtheseinstructionscouldresult
inelectricalshock,seriousinjury,ordeath.
Observealllocalgoverningcodes
andordinances.
Donot,underanycircumstances,
removethepowersupplycord
groundingprong.
NOTE:
Receptaclewiring
Electricalrequirements
Ifcodespermit,andaseparategrounding
wireisused;itisrecommendedthataqualified
electricandeterminethatthegroundingpathis
adequateandnotinterruptedbyplastic,non-
metallicgaskets,orotherinsulatingmaterials.
Receptaclewiringshouldbeaminimumof14
gauge.Usecopperwireonly.Itisyourresponsibility
toprovideproperandadequatereceptaclewiring,
installedbyaqualifiedelectrician.
A timedelayfuseortimedelaycircuitbreakeris
alsorequired. A separatecircuit,servingonlythis
appliance,MUST beprovided.
PreparingforInstallation
InstallationTips
Forwood-framecasementwindows:
Forbrickorcementbuildingconstruction:
ToolsRequired:
Itmaybenecessarytoconstructaframe,usingatleast
1-inchthickwood,witha15-1/2-inchwideopening.
Itmaybenecessarytoputawoodstoolstripunder
AC,formountingpurposes.
Flat-headscrewdriver
Phillips-headscrewdriver
Carpenterslevel
Tapemeasure
Finetoothsaw
Electricorhanddrill
`
Observe all national and local
governing codes and ordinances.
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
11
11
1.Makesureyouhaveallthenecessaryparts.
Installationkitcontents:
1.Platform(1)
2.Supportbrace(1)
3. Adjustmentbolt(1)
4.Hexflangenut-1/4(1)
5. Trackseal(1)
6.Sidechannelseal(1)
7.Foamsealstrip/Sashseal
8.Safetybracket(1)
9-11.Screw-2-1/2(2),or
Screw-1-3/4(2),or
Screw-1(2)
12.Screw-3/4(6)
13.Screw-3/4self-threading(7)
14.Windowlockingbracket(1)
15.Plasticwindowpanel(1)
16.Sidechannel(2)
17.Screw-3/8(6)
18.Panelframe/sealassembly(1)
NOTE: Usescalebelowtomeasurelength
ofyourscrews. Thescalewillcomeinhandy
whenseparatingscrewsforinstallation.
IdentifyScrews
ByLength
(25mm)
1
(44mm)
1 3 4
(63mm)
2 1 2
3 8
(10mm)
3 4
(19mm)
2.Chooseapropersizedwindow,asshownright.
NOTE:
15-12inchesminimumwidth
16-14inchesmaximumwidth(forcasement
windows)
21-14inchesminimumheight(withwindow
panelretainer)
20-516inchesminimumheight(windowpanel
retainerremoved)
39-716inchesmaximumheight
Heightmeasurementmustbeofaclearopening
abovemountingplatform.Insomecases,duetoavariety
ofstopandtrackarrangements,theabovedimensions
mayvaryslightly.Ifnecessary,installationcanbemade
byalternatingwindowjambs.(See AlternateWindowJamb
Applic
ations.)(continued)
1
2
1
4
5
16
7
16
9.
10.
11.
1/4 (1)
Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual
12
12
1
4
11
16
Windowtrack
Windowseal
Platformtab
Alternatescre wlocation
(dependingonthestooldepth)
sill.
sill depth)
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
13
13
Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual
14
14
Removethetwofrontretainingscrewsfrom
thefrontframe.
2.Gentlypullthefrontoutandliftuptorelease
itfromthecase.
1
3. Thenreleasethecouplerplugs.
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
15
3
4 or 1
3
4 or1
or
15
Firstreconnectthecouplerplugs,makethe
Exhaustcontrolpositionedthroughthefront
intheproperlocation. Thenreplacethe
retainingscrewsthatholdsthepanelinplace.
pushorpullthefrontpanellouvers.Donot
20.Toreplacethefront
Insert
Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual
16
16
glass panels must be removed before installation.
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
17
17
Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual
18
18
Removethetwofrontretainingscrewsfrom
thefrontframe.
2.Gentlypullthefrontoutandliftuptorelease
itfromthecase.
1
3. Thenreleasethecouplerplugs.
Firstreconnectthecouplerplugs,makethe
Exhaustcontrolpositionedthroughthefront
intheproperlocation. Thenreplacethe
retainingscrewsthatholdsthepanelinplace.
pushorpullthefrontpanellouvers.Donot
16.Toreplacethefront
CARE ANDCLEANING
Cleanyourairconditioneroccasionallytokeepitlookingnew. Besuretounplugtheunit
beforecleaningtopreventshockorfirehazards.
CAUTION
AirFilterCleaning
Theairfiltershouldbecheckedatleastoncea
monthtoseeifcleaningisnecessary. Trapped
particlesinthefiltercanbuildupandcausean
accumulationoffrostonthecoolingcoils.
Graspthefilterbythecenterandpullupandout.
Washthefilterusingliquiddishwashingdeter-
gentandwarmwater.Rinsefilterthoroughly.
Gentlyshakeexcesswaterfromthefilter.Be
surethefilteristhoroughlydrybeforereplacing.
Or,insteadofwashingyoumayvacuumthe
filterclean.
Neverusehotwaterover40 C(104 F) to
cleantheairfilter.Neverattempttooperatethe
unitwithouttheairfilter.
Besuretounplugtheairconditionertoprevent
shockorfirehazard. Thecabinetandfrontmay
bedustedwithanoil-freeclothorwashedwith
aclothdampenedinasolutionofwarmwater
andmildliquiddishwashingdetergent.Rinse
thoroughlyandwipedry.
Neveruseharshcleaners,waxorpolishonthe
cabinetfront.
Besuretowringexcesswaterfromtheclothbefore
wipingaroundthecontrols.Excesswaterinoraround
thecontrolsmaycausedamagetotheairconditioner.
Pluginairconditioner.
Ifyouplantostoretheairconditionerduringthewinter,
removeitcarefullyfromthewindowaccordingtothe
installationinstructions.Coveritwithplasticorreturnit
totheoriginalcarton.
Topreventrustorelectricalconnectionsfrombeing
damaged,storeairconditionerinanuprightpositionandin
adryplace.
Note:
CabinetCleaning
NOTE:
WinterStorage
19
Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc.
19
CARE ANDCLEANING
Cleanyourairconditioneroccasionallytokeepitlookingnew. Besuretounplugtheunit
beforecleaningtopreventchockorfirehazards.
CAUTION
AirFilterCleaning
Theairfiltershouldbecheckedatleastoncea
monthtoseeifcleaningisnecessary. Trapped
particlesinthefiltercanbuildupandcausean
accumulationoffrostonthecoolingcoils.
Removethefilterbyslidingoutfromtheright-
handside.
Washthefilterusingliquiddishwashingdeter-
gentandwarmwater.Rinsefilterthoroughly.
Gentlyshakeexcesswaterfromthefilter.Be
surethefilteristhoroughlydrybeforereplacing.
Or,insteadofwashingyoumayvacuumthe
filterclean.
Neverusehotwaterover40 C(104 F) to
cleantheairfilter.Neverattempttooperatethe
unitwithouttheairfilter.
Besuretounplugtheairconditionertoprevent
shockorfirehazard. Thecabinetandfrontmay
bedustedwithanoil-freeclothorwashedwith
aclothdampenedinasolutionofwarmwater
andmildliquiddishwashingdetergent.Rinse
thoroughlyandwipedry.
Neveruseharshcleaners,waxorpolishonthe
cabinetfront.
Besuretowringexcesswaterfromtheclothbefore
wipingaroundthecontrols.Excesswaterinoraround
thecontrolsmaycausedamagetotheairconditioner.
Pluginairconditioner.
Ifyouplantostoretheairconditionerduringthewinter,
removeitcarefullyfromthewindowaccordingtothe
installationinstructions.Coveritwithplasticorreturnit
totheoriginalcarton.
Note:
CabinetCleaning
WinterStorage
15
WARNING!
104°F (40°C)
shock
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

COMFORT-AIRE CD-121 Owner's manual

Category
Split-system air conditioners
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI