2-2
PRODUCT DATA SHEET
2.2 Indoor Units Data
2.2.1 FLO 9 DCI Specifications
Model Indoor Unit / Type FLO 9 DCI / Wall Mounted
Installation Method FLARE
Fan Motor Output W 20
Power Supply V/Ph/Hz 220-240 / 1/ 50
INDOOR
Fan Type & Quantity Crossflow *1
Airflow
(2)
Cooling / Heating
H/M/L m
3
/hr 530/570 430/460 330/350
Sound Power Level
(3)
Cooling / Heating
L - H dB (A) 39-50 / 39-51
Sound Pressure Level
(4)
Cooling / Heating
L - H dB (A) 26-38 / 26-39
Condensate Drain Tube I.D. mm 16
Dimensions W/H/D mm 810 285 202
Weight kg 11
Package Dimensions W/H/D mm 885 360 285
Stacking Height Units 7
Heating Elements kW N/A
Moisture Removal L/hr 1
2.2.2 WFLO 12 DCI Specifications
Model Indoor Unit / Type WFLO 12 DCI / Wall Mounted
Installation Method FLARE
Fan Motor Output W 20
Power Supply V/Ph/Hz 220-240 / 1/ 50
INDOOR
Fan Type & Quantity Crossflow *1
Airflow
(2)
Cooling / Heating
H/M/L m
3
/hr 550/580 450/480 350/370
Sound Power Level
(3)
Cooling / Heating
L - H dB (A) 39-52 / 39-52
Sound Pressure Level
(4)
Cooling / Heating
L - H dB (A) 26-39 / 26-40
Condensate Drain Tube I.D. mm 16
Dimensions W/H/D mm 810 285 202
Weight kg 11
Package Dimensions W/H/D mm 885 360 285
Stacking Height Units 7
Heating Elements kW N/A
Moisture Removal L/hr 1.5
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.