MINISPLIT : CASSETTE SPECIFICATIONS
MODELS
Capacities
Noise Level
System Operation Control
Dimensions
Net Weight
Piping
The Nominal Cooling Capacity is based on :
- Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Piping length : 5m
The Nominal Heating Capacity is based on :
- Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5m
Compressor
Refrigerant
Power Consumption
Running Current
Indoor Air Flow
Indoor
Unit
Cooling
Indoor
Outdoor
Indoor
Outdoor
Size
Indoor/Outdoor
Connection Type
Heating
Type
25
Btu/h
kW
kcal/h
Btu/h
kW
kcal/h
V/Ph/Hz
Ph
220-240/1/50 or 380-415/3/50
1
3.4
16.4
3
3.3
6.8
3
4.77
8.9
3
5.6
11.2
1,260
39/42/44
58
1,800
39/42/44
60
2,100
42/44/48
63
H (mm)
W (mm)
D (mm)
290/696
710/850
710/287
36
68
290/900
710/850
710/285
36
85
340/1,142
810/850
810/285
42
90
340/1,142
810/1,060
810/345
44
109
Suction
Liquid
5/8"
3/8"
5/8"
3/8"
3/4"
3/8"
3/4"
3/8"
35 45
Reciprocating
55
25
24,000
7.0
6,060
25,600
7.5
6,465
35
32,000
9.4
8,080
32,500
9.5
8,207
45
42,000
12.3
10,606
42,800
12.5
10,808
55
52,000
15.2
13,131
52,800
15.5
13,333
Outdoor
Unit
MKC-MKH
MOC-MOH
R-22
Wired or Wireless Control with LCD Display
Flare and Nuts
BE-MK0101-05035T73000-002
dBA
kgs
4 CM.
Panel Thickness
Low Profile Turbo fan Air filter 4 Way Air flowWireless/Wired Control
Power Supply
kW
A
m
3
/h
PRODUCT:
• Four way air flow system
• Quiet Turbo fan
• Easily detachable grill for cleaning
• Air filter
1
2.8
13.0
3
2.7
5.4
1,260
39/42/44
57
Split System Air Conditioners
Ceiling Cassette
cools the biggest and most important buildings.
Gets chosen for the most critical refrigeration projects.
Creates the most comfortable homes.
Sponsors the most watched sporting events.
CONTROL:
Wired or wireless versions available
5 Operation modes
(Cool/Heat/Auto/Dry/Fan)
Sleep mode and independent
on - off Timers
3 speed fan control
Room temperature setting
Filter cleaning indicator
LCD display with clock
Auto restart memory
Diagnostic function with
LED indicators
CONDENSING UNITS:
Quiet operation with sound insulating blanket
and rubber mounting on compressor
High efficiency compressor
Built-in drain pipe connector
for condensate