Datalogic DS8100A User manual

Category
Bar code readers
Type
User manual
DS8100A
Reference Manual
DS8100A
REFERENCE MANUAL
DATALOGIC S.p.A.
Via Candini 2
40012 - Lippo d
Bologna - Italy
i Calderara di Reno
DS8100A Reference Manual
Ed.: 07/2006
ALL RIGHTS RESERVED
atalogic reserves the right to make modifications or improvements without prior notification.
D
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for
ncidental or consequential damages resulting from the use of this material. i
Product names mentioned herein are for identification purposes only and may be trademarks and or
egistered trademarks of their respective companies. r
Datalogic S.p.A. 2005 - 2006 ©
19/07/06
CONTENTS
REFERENCES .............................................................................................................v
Reference Documentation ............................................................................................ v
Services and Support ................................................................................................... v
COMPLIANCE.............................................................................................................vi
Electrical Safety........................................................................................................... vi
Laser Safety................................................................................................................. vi
Power Supply...............................................................................................................vii
WEEE Compliance ......................................................................................................vii
GENERAL VIEW .......................................................................................................viii
GUIDE TO INSTALLATION ........................................................................................ xi
Point-to-Point Installation............................................................................................. xi
Master/Slave Lonworks Installation .............................................................................xii
1 INTRODUCTION ..........................................................................................................1
1.1 Product Description ......................................................................................................1
1.2 Applications ..................................................................................................................1
1.3 Model Description.........................................................................................................3
1.3.1 Oscillating Mirror Models ..............................................................................................3
1.4 Indicators ......................................................................................................................4
1.5 Accessories ..................................................................................................................5
2 INSTALLATION ...........................................................................................................6
2.1 Package Contents ........................................................................................................6
2.2 Mechanical Mounting....................................................................................................7
2.2.1 Mounting the Scanner...................................................................................................7
2.2.2 Mounting the Scanner with Accessories.......................................................................8
2.3 Electrical Connections ................................................................................................10
2.3.1 Main/Aux. Serial Interface and I/O Connector ............................................................11
Main Interface.............................................................................................................12
Auxiliary Interface .......................................................................................................14
Inputs..........................................................................................................................14
Outputs .......................................................................................................................17
2.3.2 Lonworks Input/Output Connector..............................................................................18
Network Termination................................................................................................... 19
Lonworks Interface .....................................................................................................20
2.3.3 Ethernet Connector.....................................................................................................22
Ethernet Interface .......................................................................................................23
2.3.4 Power Supply.............................................................................................................. 23
2.4 User Interface .............................................................................................................24
2.5 Positioning the Scanner..............................................................................................24
2.6 Typical Layouts...........................................................................................................26
2.6.1 Point-to-Point..............................................................................................................27
2.6.2 Pass Through .............................................................................................................28
2.6.3 RS232 Master/Slave...................................................................................................29
2.6.4 Multiplexer ..................................................................................................................31
2.6.5 Local Lonworks Network.............................................................................................32
Small Synchronized Network......................................................................................33
iii
Large Synchronized Network......................................................................................35
Redundant System .....................................................................................................37
Multidata Network.......................................................................................................38
2.6.6 Fieldbus Network........................................................................................................39
2.7 Keypad and Display....................................................................................................40
2.7.1 Internal Net .................................................................................................................40
2.7.2 Test Mode...................................................................................................................40
3 SOFTWARE CONFIGURATION................................................................................41
3.1 Genius™ Installation...................................................................................................41
3.2 Guide to Rapid Configuration .....................................................................................41
3.2.1 Wizard for Quick Reader Setup..................................................................................41
Test Operating Mode..................................................................................................42
On Line Operating Mode ............................................................................................43
Automatic Operating Mode.........................................................................................43
3.2.2 Genius™ Network Setup Through Master..................................................................44
Net-Autoset.................................................................................................................46
Express Network Setup ..............................................................................................46
Network Wizard ..........................................................................................................47
3.2.3 Alternative Slave Address Assignment.......................................................................49
3.3 Advanced Genius™ Configuration .............................................................................49
3.4 Parameter Default Values...........................................................................................50
4 READING FEATURES...............................................................................................53
4.1 Advanced Code Reconstruction (ACR™ 4)................................................................53
4.1.1 Tilt Angle for Advanced Code Reconstruction ............................................................ 53
4.2 PackTrack™ ...............................................................................................................54
4.2.1 PackTrack™ Calibration for DS8100A .......................................................................56
4.2.2 PackTrack™ Calibration for DS8100A Oscillating Mirror Models...............................58
4.3 Performance ...............................................................................................................58
4.3.1 Reading Conditions ....................................................................................................58
4.4 Reading Diagrams ......................................................................................................60
5 MAINTENANCE ......................................................................................................... 70
5.1 Cleaning......................................................................................................................70
5.2 Automatic Scanner Replacement (ASR) ....................................................................70
5.2.1 ASR Network Configuration........................................................................................70
5.2.2 Scanner Replacement Procedure...............................................................................71
6 TROUBLESHOOTING ............................................................................................... 72
7 TECHNICAL FEATURES...........................................................................................75
GLOSSARY................................................................................................................ 77
INDEX......................................................................................................................... 80
iv
REFERENCES
REFERENCE DOCUMENTATION
The documentation related to the DS8100A management is listed below:
C-BOX100 Installation Manual
PWR series power supply unit Installation Manuals
PWO power supply unit Installation Manual
GFC-80 90° deflecting mirror
GFC-800 90° deg. mirror close distance
SC6000 Controller Reference Manual
Document about the Ethernet connectivity
Help On-Line in PDF format
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on
to www.datalogic.com and click on the
links indicated for further information including:
PRODUCTS
Search through the links to arrive at your product page where you can download specific
Manuals and Software & Utilities
SERVICES & SUPPORT
Datalogic ServicesWarranty Extensions and Maintenance Agreements
Authorised Repair Centres
CONTACT US
E-mail form and listing of Datalogic Subsidiaries
v
COMPLIANCE
ELECTRICAL SAFETY
This product conforms to the applicable requirements contained in the European Standard for
electrical safety EN-60950 at the date of manufacture.
WARNING
This symbol refers to operations that must be performed by qualified
personnel only. Example: opening the device.
WARNING
make sure the power cable is
disconnected to avoid electric shock.
This symbol refers to operations where there is danger of electrical
shock. Before opening the device
LASER SAFETY
The following information is
authorities and refers to the c
provided to comply with the rules imposed by international
orrect use of the DS8100A scanner.
though staring directly at the laser
at the date of manufacture. The reader is classified as a Class 2 laser
here is a safety device which allows the laser to be switched on only if the motor is rotating
bove the threshold for its correct scanning speed.
Standard Regulations
This scanner utilizes up to 4 low-power laser diodes. Al
beam momentarily causes no known biological damage, avoid staring at the beam as one
would with any very strong light source, such as the sun.
Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such
as mirrors, etc.
This product conforms to the applicable requirements of both EN60825-1 and
CDRH 21 CFR1040
product according to EN60825-1 regulations and as a Class II laser product according to
CDRH regulations.
T
a
WARNING
Use of controls or adjustments or performance of procedures other than those
specified herein may result in exposure to hazardous visible laser light.
The laser light is visible to the human eye and is emitted from the window on the side of the
scanner (Figure A).
vi
Warning labels indicating exposure to laser light and the device classification are applied
onto the body of the scanner (Figure A):
AVOID EXPOSURE
LASER LIGHT IS EMITTED
FROM THIS APERTURE
CAUTION-CLASS 3B
LASER LIGHT
WHEN OPEN
AVOID
EXPOSURE TO BEAM
Model No. Amp.
Serial No.
DATALOGIC S.P.A. Via Candini, 2
40012 Calderara di Reno - Bologna - Italy
Manufactured Volt
This product conforms to the applicable requirements
of 21CFR1040 at the date of manufacture.
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAXIMUM OUTPUT RADIATION 1 mW
EMITTED WAVELENGTH 630~680 nm
TO EN 60825-1:2001
Warning and Device Class Labels
Disconnect the power supply when opening the device during maintenance or installation to
avoid exposure to hazardous laser light.
The laser diodes used in this device are classified as Class 3B laser products according to EN
60825-1 regulations and as Class IIIb laser products according to CDRH regulations. As it is
not possible to apply a classification label on the laser diodes used in this device, the
following label is reproduced here:
LASER LIGHT
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
MAXIMUM OUTPUT RADIATION 30 mW
EMITTED WAVELENGTH 630~680 nm
TO EN 60825-1 (2001)
Laser Diode Class Label
Any violation of the optic parts in particular can cause radiation up to the maximum level of
the laser diode (30 mW at 630~680 nm).
POWER SUPPLY
- This scanner is intended to be supplied by either a UL Listed power supply marked 'Class
2' or 'LPS', output rated 20 – 30 V dc , minimum 1.5 A or by a UL Listed computer with
LPS outputs.
- This scanner must be supplied by a Class II Power Supply Unit conforming to the
EN 60950 safety regulation.
WEEE COMPLIANCE
vii
GENERAL VIEW
DS8100A
5
1
2
8
3 4
6
7
Figure A – DS8100A
Laser Beam Output Window
Laser Safety Label
Product Label
Warning and Device Class Label
1
2
3
4
Connector Panel
Display
Service Access Cap
5
6
7
Mounting Holes
8
viii
DS8100A
Figure B – DS8100A Oscillating Mirror Version
Laser Beam Output Window
1
Laser Safety Label
2
Figure C – Display and Keypad Panel
1
7
1
2 3
4 5 6
2
Programming Keypad
Power On LED (Green)
Phase On LED
(
Yellow
)
Encoder LED (Yellow)
1
2
3
4
TX Data LED (Green)
Network LED (Red)
LCD Display
5
6
7
ix
1
3
2
Figure D – Connector Panel for Standard Models
Serial interface and I/O 26-pin connector
3
Lonworks 17-pin male connector
1
2
Lonworks 17-pin female connector
1
Figure E – Connector Panel for Ethernet Mo
2
4
3
dels
Lonworks 17-pin male connector
Lonworks 17-pin female connector
Harting RJ industrial connector
1
2
4
Serial interface and I/O 26-pin connector
3
x
GUIDE TO INSTALLATION
OINT-TO-POINT INSTALLATION P
he following can be used as a checklist to verify all the necessary steps to completT e
) e beginning of this manual.
par. 2.2 and position it at the
3)
Point-to-Point, Pass Through, RS232 Master/Slave, Fieldbus. See sub-
85 Full
For further
4) Configure the DS8100A scanner by installing and running the Genius™ configuration
installation of the DS8100A scanner.
Read all information in the section “Safety Regulations” at th1
2) Correctly mount the scanner according to the information in
correct reading distance as shown in par. 2.5 and par. 4.4.
Make electrical connections to your DS8100A scanner by:
a) Connecting the DS8100A scanner to the C-BOX 100 by means of one of the
CAB-601X cables provided as accessory (see par. 1.5).
b) Providing correct and complete system cabling through the C-BOX 100 according to
the signals necessary for the layout of your application (trigger, inputs, outputs).
Layout:
paragraphs under 2.6 for reference.
Cabling: Power, Main Serial Interface – RS232, RS485 Half Duplex, RS4
Duplex, 20 mA Current Loop, Auxiliary Interface, Inputs, Outputs, etc -.
details, see all sub-paragraphs under par. 2.3.
program from the CD-ROM provided. The main steps are:
Select the codes to be read
Set-up the communication parameters
When PackTrack™ is required, perform PackTrack™ calibration
Define data formatting parameters
NOTE
in Genius™.
Fine tuning of the scanner position for barcode reading can be
accomplished by performing a test through the SPY configuration tool
5) xi
The installation is now complete.
E t the configuration program and run your application.
xi
MASTER/SLAVE LONWORKS INSTALLATION
installation of the DS8100A scanner in a Master/Slave Lonworks network.
t the beginning of this manual.
) Correctly mount the scanner according to the information in par. 2.2 and position it at the
own in par. 2.5 and par. 4.4.
3) Make electrical connections to your DS8100A scanner by:
a) Connecting the DS8100A
Master
The following can be used as a checklist to verify all the steps necessary to complete
1) Read all information in the section “Safety Regulations” a
2
correct reading distance as sh
scanner to the C-BOX 100 by means of one of the
CAB-601X cables provided as accessory (see par. 1.5).
b) Correctly terminating the DS8100A Master reader according to the information given
under “Local Lonworks Network” in par. 2.3.2 and par. 2.6.5.
c) Completing the system wiring adding as many slave scanners as required by your
system layout (refer to par. 2.6.5).
d) Correctly providing bus return to the last DS8100A Slave reader of the network
according to the information given under “Local Lonworks Network” in par. 2.3.2 and
par. 2.6.5.
4) Install and run the Genius™ configuration program from the CD-ROM provided.
Configure the Local Lonworks Network using one of the procedures given below:
a) Configure the entire network through the Master as described in par. 3.2.2;
b) Configure the Master as described in par. 3.2.2 and locally define each slave scanner
address as described in par. 3.2.3.
c) Define each scanner, master and slaves (with their addresses), by using the scanner
keypad according to the information given in par. 2.7.1.
5) Configure the Master scanner through the Genius™ program. The main steps are:
Select the codes to be read
Set-up the communication parameters
When PackTrack™ is required, perform PackTrack™ calibration, see par. 4.2.1.
Define data formatting parameters
6) Configure each Slave scanner through the Master scanner using Genius™. The main
steps are:
Select the codes to be read
When PackTrack™ is required, perform PackTrack™ calibration, see par. 4.2.1.
NOTE
Fine tuning of the scanner position for barcode reading can be
accomplished by performing a test through the SPY configuration tool
in Genius™.
xii
7) Send the configuration to the Master.
8) Optionally, perform the ASR Network Configuration procedure for system backup
purposes (see par. 5.2.1).
9) Exit the configuration program and run your application.
The installation is now complete.
xiii
xiv
INTRODUCTION
1
1 INTRODUCTION
1.1 PRODUCT DESCRIPTION
The DS8100A scanner is a barcode reader complete with decoder designed to provide an
innovative and high performance solution in omnidirectional reading applications by
combining the following advanced technologies with Datalogic solid experience in the
material handling sector.
Some of the main features of DS8100A are listed below:
scanning speed 1000 scans/sec.
reads all popular codes.
supply voltage from 20 to 30 Vdc.
test mode to verify the reading features and exact positioning of the scanner without the
need for external tools.
programmable in 5 different operating modes to suit the most various barcode reading
system requirements.
light source: solid state laser diodes; the light emitted has a wave length between
630~680 nm. For laser safety precautions refer to the “Safety precautions” section at the
beginning of this manual.
1.2 APPLICATIONS
The DS8100A barcode reader is specifically designed for industrial applications and for all
cases requiring high reading performance such as:
code reconstruction
reading of codes covered by plastic film
reading of codes with a wide depth of field
reading of high resolution codes positioned at long distances from the reader
code reading on fast moving objects.
DS8100A is designed for both single-reader layouts and multi-reader layouts. For typical
layouts see paragraph 2.6
1
DS8100A
1
Feature
Benefit
ACR™
Advanced Code Reconstruction technology
allows the reading of low aspect ratio labels
placed anywhere on a parcel and enhances the
readability of poorly printed or damaged codes.
CD SQUARE™
CD SQUARE™ provides useful information on
label position and object shape elaborated during
the barcode reading phase. This innovative
technology identifies the area in which the code is
located and measures the code distance from the
scanner.
PACKTRACK™
PackTrack™ is a Datalogic patented parcel
tracking system which improves the reading
features in omnidirectional stations. In particular,
PackTrack™ manages 6-sided reading systems
when it is impossible to detect the real position of
the code on the parcel, thus overcoming the need
for external accessories essential in traditional
tracking systems.
ASTRA™
Automatically SwiTched Reading Area™ is the
new Datalogic technology based on a multi-laser
architecture and a fixed mounted optic system
which concentrates the multiple laser emissions in
a single laser beam. As each laser emitter is
focused on a specific range of the reading area, a
sophisticated electronic controller selects the best
focused laser emitter with respect to the code to
read. This allows the reading of medium-high
density codes in a large reading area on very fast
conveyors.
Flexibility
The high frequency laser diode modulation
system guarantees complete immunity to ambient
light and allows installation of the DS8100A in any
working area.
Reading parcels on conveyors
As a result of the ASTRA™ multiple laser
technology, DS8100A gives a great real time DOF
even on high speed conveyors. Furthermore,
DS8100A implements the Packtrack™
functionality which leads to an increase of the
plant production as a result of the augmented
system throughput.
Master working as a
Multiplexer on high speed
Lonworks bus
Great competitiveness of the offer, since the cost
of an external multiplexer is saved;
High data transfer on an industrial, reliable bus
running at 1.25 Mbit/sec.
Genius™ Configurator SW
Reduced learning time, with an easy wizard
approach;
Multilanguage platform;
All the configuration parameters stored in the
scanner;
Not dependent on the Physical interface.
2
INTRODUCTION
1
1.3 MODEL DESCRIPTION
The DS8100A scanner is available in versions that differ depending on the interface
connection, the optical resolution and on the optic version:
DS8100A - X X X X
O
p
tic Version:
0 = Linea
r
O
p
tical Resolution:
0 = Low resolution
1 = Medium resolution
Communication Type:
0 = Standa
r
d version
1 = Ethernet version
2 = High resolution
3 = Very High resolution
5 = Oscillating mirror
Laser Number:
2 = Double lase
r
3 = Tri
p
le lase
r
1.3.1 Oscillating Mirror Models
Oscillating mirror models are used when coverage of a large reading area is required, mainly
in picket fence applications.
The oscillating mirror is placed in front of the reading aperture of the DS8100A scanner to
deflect the laser beam. As the mirror moves, this sweeping function of the laser beam allows
the coverage of a larger area to locate the barcodes. The code can also be reconstructed as
the beam sweeps over it.
The aperture angle is symmetrical and the scan line perpendicular to the scanner is at 0° as
shown in the figure below.
+25°
-25°
F - Oscillating Mirro rence Angle
By configuring the oscillating speed up to the max value of 19 Hz, raster emulation can
Hz Max. Aperture
igure 1 r Refe
imum
be performed for reading fast moving objects.
0-5 50°
6-10 30°
11-15 20°
16-19 10°
3
DS8100A
1
By limiting
NOTE
the raster width to the minimum necessary, the number of
scans on the reading surface is increased.
The oscillating mirror is completely controlled by software commands and therefore avoids
s of the software configuration parameters see
e Genius™ Help On Line.
1 T
T A h D
T rs h l
)
(yellow) Indicates the external presence sensor is active.
N
ive.
TX DATA
(green) Indicates data transmission both on the main and on the auxiliary
interface.
NETWORK
(red) Indicates the Lonworks network is functioning correctly. This LED is
normally ON.
These LEDs are always OFF when the DS8100A works as Slave.
complex mechanical calibrations. For detail
th
.4 INDICA ORS
he DS8100
he indicato
as five LE
ave the fo
s on the rear panel.
lowing functions:
POWER ON
(green Indicates the scanner is turned on.
PHASE ON *
E CODER *
(yellow) Indicates the external encoder signal is act
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97

Datalogic DS8100A User manual

Category
Bar code readers
Type
User manual

Ask a question and I''ll find the answer in the document