Interlogix 1038 Series Installation guide

Type
Installation guide
1038-N
1038 Series
Surface Mount with Wire Leads
Gap Distance Closed Loop
1" 1038
Color
White, Mahogany Brown
Quantity
10
100% TESTED
GE Magnetic Contacts
UL Specifications
Part Loop Electrical Gap
Number Type Configuration Distance
*
1038 Closed N.O. 1"
*
Gap Specifications are nominal and may vary
±
20%. Gap Specifications are for switch to make.
Break distance is approximately 1.1 to 1.5 times make.
WARNING: Each electrical rating is an individual maximum and cannot be exceeded!
**
FORM A (1038)
Voltage: 100 V AC/DC max
Current: 0.5 A max
Power: 7.5 W max
1038 Series
Surface Mount with Wire Leads
Installation Instructions
1. Clean mounting surfaces with alcohol pad (included).
2. Align and attach mounting plates for the switch and magnet using tape or screws (included).
Wire may be routed on either end or through the top of the switch housing cutouts.
3. Strip loop wire and connect the leads to the alarm loop.
4. Place switch and magnet covers over the center of the mounting plates and slide either left or
right until the cover snaps in place.
1038696 Rev A 07/02
www.GE-InterlogixSecurity.com 2266 Second Street North
North St. Paul, MN 55109
Phone: 651-777-2690
USA & Canada: 800-777-5485
Technical Service: 800-777-2624
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
Faxback: 800-483-2495
GE Interlogix
2.26"
(5.74cm)
.38"
(0.95cm)
.40"
(1.00cm)
1.63"
(4.13cm)
Made in Taiwan