Cumberland POWERTRAK Owner's manual

  • Hello! I have reviewed the Cumberland PowerTrak Wiring Harness user manual. This document details the connection of a 9-conductor harness to a 3-wire controller, including specific wiring instructions, and connection details for control wires, and power supply. I'm ready to help with any questions you may have regarding this conversion process.
  • What should I do with the old wiring before connecting new?
    What control wires should I use for Farm Hand Controls?
    Which wires are for power supply?
Part #: 4801-0153 PowerTrak 3 Wire Conversion PowerTrak
CUMBERLAND Assumption, IL 62510 Phone 1-217-226-4421 Fax 1-217-226-4420
PowerTrak Wiring Harness
9 Conductor PowerTrak Connection to 3 Wire Controller
If you have a standard PowerTrak with a PCB-135A circuit board:
1. Disconnect the nine conductor wire, and limit switch and motor harness from the board.
2. Plug harness provided into motor, and limit switch harness.
3. Use Yellow(COM), Red(CLOSE), Brown(OPEN) control wires to go to Farm Hand Controls.
4. Use Green(GROUND), Black(HOT), White(Neutral) to supply 120V/240V power (depending on model) to the
PowerTrak.
5. Attach Label (Included) to inside of PowerTrak Door for future reference.
J3
12
11
10
9
8
7
6
5
1
2
3
4
J2
1
2
3
4
J1
9
8
7
6
5
4
3
2
1
J2
9
8
7
6
5
4
3
2
1
FAN-UPPER1
FAN-LOWER2
FAN-LOWER1
4 Pin from motor
12 Pin from limit switches
Blue
White
Red
FAN-UPPER2
Plug harness into 12 pin limit
switch connector.
110vac White
Com Yellow
110vac Black
Close Red
Open Brown
Ground
Power to Unit 110VAC
Control Wires to Controller
9 Pin from controller
/