CAME LUXO, PLACO Installation guide

Type
Installation guide

CAME LUXO, PLACO is a high-quality video entry kit that provides a secure and convenient way to communicate with visitors at your door. The kit includes a video terminal, a power supply, and a variety of accessories that allow you to customize the system to meet your specific needs.

The video terminal features a 7-inch TFT LCD display that provides clear and detailed images of visitors. The terminal also has a built-in microphone and speaker, so you can communicate with visitors hands-free.

The power supply provides the video terminal with the power it needs to operate. The power supply can be connected to either a 16-18 VAC or a 230 VAC power source.

CAME LUXO, PLACO is a high-quality video entry kit that provides a secure and convenient way to communicate with visitors at your door. The kit includes a video terminal, a power supply, and a variety of accessories that allow you to customize the system to meet your specific needs.

The video terminal features a 7-inch TFT LCD display that provides clear and detailed images of visitors. The terminal also has a built-in microphone and speaker, so you can communicate with visitors hands-free.

The power supply provides the video terminal with the power it needs to operate. The power supply can be connected to either a 16-18 VAC or a 230 VAC power source.

10
11
7
2
+
001DC011AC
001DC002AC
001DC011AC
001DC01LUXO
001CS2PLCO
INSTALLATION MANUAL
001CK0016FR
001CK0017FR
EN
English
FA00963-EN
VIDEO ENTRY KIT
2
1
a
212
161
29
60
83,5
83,5
B
A
C
Page 2 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
General Notes
• Read the instructions carefully before beginning the installation and carry
out the actions as specied by the manufacturer.
The installation, programming, commissioning and maintenance of the
product must only be carried out by qualied technicians, properly trained
in compliance with the regulations in force, including health and safety
measures and the disposal of packaging.
The installer must ensure that the information for the user, where there is
any, is provided and delivered.
• Before carrying out any cleaning or maintenance operation, disconnect the
devices from the power supply.
The equipment must only be used for the purpose for which it was
expressly designed.
The manufacturer declines all liability for any damage as a result of impro-
per, incorrect or unreasonable use.
This product complies with the relevant directives in force.
Decommissioning and disposal. Dispose of the packaging and the device
at the end of its life cycle responsibly, in compliance with the laws in force
in the country where the product is used. The recyclable components are
marked with a symbol and the material's ID marker.
The data and information shown in this manual are to be considered as
subject to change at any time and without the need for any advance warning.
Measurements, unless otherwise indicated, are in millimetres.
001DC01LUXO
Wall-mounted installation
Unfasten the equipment from the metal support by letting it run smoothly
along it after you have pressed the plastic catch A.
Fix the metal support to the round Ø 60 mm back-box Ba or the rectan-
gular 503 back-box BB using the screws provided and paying
attention to the (TOP) direction indication. The box must be installed at
an appropriate height for the user. Avoid tightening the screws too much.
Once the connections are made, hook the video terminal onto the metal
support CD.To unhook the unit from the metal support press the plastic
catch and lift the terminal E.
For recessed installation refer to the recessing kit manual.
D
F
G
H
I
LOCAL
BUS
LOCAL
BUS
CL.RES
M/S
LOCAL
SW1 SW3
SW4
M1
BUS
CL.RES CL.RES CL.RES
001DC006AC
1 2 3
MASTER SLAVE
M/S M/S
1
E
Page 3 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Technical Features
Type
001DC01LUXO
Power supply by BUS (VDC)
15÷20
Consumption (mA max)
410
Consumption in stand by (mA)
<1
Local power supply (VDC)
16÷18
Consumption (mA max)
370
Consumption of single LED (mA)
(panic, disabling ring)
1
Storage temperature (°C)
-25 ÷ +70
Operating temperature (°C)
0 ÷ +35
IP Rating
20
Video standard
PAL/NTSC
Display colour TFT LCD (pollici)
7
Features
Terminal board Fa
+Local power supply
BBUS line input
+Doorbell
AL Alarm Input
Selection of source of power supply (BUS/LOCAL) G
Separate power supply
Power supply by BUS
Selection of last receiver on the line (CL.RES) H
Master/slave selection (M/S) I
In the event of a call, the caller’s picture is displayed only on those receivers
congured as “MASTER”s.
Page 4 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Setting melodies
All the programming stages described below must be carried out in sequence:
1- Going into Programming.
Press button 5 times in 5 secs.
A short beep conrms that you have entered programming mode.
2- Programming the melody associated with a call from the entry panel.
To listen to the melodies in sequence, press key .
To select the melody and exit programming, press key .
To select the melody and continue with programming, press key .
3- Programming the melody associated with a call from the front door.
To listen to the melodies in sequence, press key .
To select the melody and exit programming, press key .
To select the melody and continue with programming, press key .
4- Programming the number of rings for the call.
Press key as many times as you want it to ring (from 1 to 6 rings). Three seconds after the last press of the key the call selected for the chosen number of
rings will be played back.
To exit programming, press key .
See the entry panel documentation for call programming.
A
43,5
45
7,5 57
70
106
A
B
64,5
70
145
43,5
45
7,5 57
M2M1
+
a
Page 5 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
001DC002AC
Installation
The power supplier must ALWAYS be installed horizontally. The device can be
installed on a DIN rail (EN 50022) in an appropriate electric panel.
NOTE. Proper ventilation is required if the power supplier is installed in a
metal container.
Technical features
Type
001DC002AC
Power supply [V AC] 230
Max current demand [A AC] 0,2
Max energy dissipation [W] 10
Nominal power supply [V DC] 18
Nominal current demand [A DC] 1 for 1’
Nominal current demand [A DC] 0.5 for 3’
Storage temperature [°C] -25 ÷ +70
Operating temperature [°C]
0 ÷ +35
IP Rating [IP] 30
Features A
Terminal board a
~Mains
~
Terminal board
+Power supply 18 VDC (*)
(*) The appliance is electronically protected against overloads and short
circuits.
48,5 mm
21 mm
60 mm
85,5 mm
69,5 mm
A
10
11
7
2
+
001DC011AC
a
Page 6 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
001DC011AC
Device description A
The 001DC011AC AC/DC converter is device designed for the installation
of audio receivers and video receivers coupled with a compatible gate
automatism equipped with an accessory output.
With just 4 wires that connect the gate with the audio receiver/video receiver
kit, the device not only supplies the kit but it also allows you to operate the
gate. Command 2-7 is executed by a clean contact (relay).
Technical features
Type 001DC011AC
Minimum input voltage (V AC) 20
Maximum input voltage (V AC) 25
Output voltage (V DC) 18
Output current (A) 1
Maximum operating relative humidity without
condensation 95
Storage temperature (°C) -25 ÷ +70
Operating temperature (°C) -15 ÷ +50
Features of terminals 2 - 7
Control voltage: 12V - 12.5 mA
Maximum switching voltage: 50 V AC or 75 V DC
Maximum switching power: 60VA - 24W
Function of terminals
18V DC supply output
+
2Opening command output towards gate
7
10 Power supply input 20÷25V AC
11
Opening command input from entry panel
A
C
500 mm
1080 mm
77¡
94¡
800 mm
500 mm
163,5 mm
43,5 mm
500 mm
1080 mm
77¡
94¡
800 mm
500 mm
163,5 mm
43,5 mm
135
99 30
3.5
6.5
243
207
135
99 30
3.5
6.5
243
207
B
D
Page 7 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
H= 165 cm
(RECOMMENDED
HEIGHT)
Recessed Installation (optional)
Install the recessed box at the desired height considering the position of
the lens of the camera C, but in advance, run the hose with the system
conductors through one of the breaking points F a.
001CS2PLCO
Wall Mounting
With the allen wrench unscrew the blocking screws and remove the plate
A. Fix the given plugs and screw the entry panel B at the desired height
considering the position of the lens of the camera C.
Run the hose with the system conductors B.
Extract the plastic terminal cover and wire the connections D.
Once all the connections have been made, re-insert the terminal covers.
For the installation of the accessories refer to the chapter “Button module in-
stallation”. Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming”. Install the front plate A.
G
I
F
1
2
A
B
a
E
J
H
Page 8 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
During installation of the recessed box it is possible to avoid any deforma-
tion by using the provided spacer F . With the allen wrench unscrew
the blocking screws and remove the entry panel plate A. Introduce the
cable connections in the special hole B and x the entry panel on the
frame as shown in gure G; extract the plastic terminal cover and wire
the connections D.
Once the connections have been made and re-insert the terminal covers.
For the installation of the accessories refer to the chapter “Button module
installation”.
Perform the programming and adjustment operations of the entry panel as
described to the chapter “Programming. Install the front plate A.
Button module installation
Insert the button module as highlighted H paying special attention to the
top to bottom orientation J.
Remove the glass and write the user names I, paying special attention to
the orientation of the glass J.
K
a
M1
BOUT
M2
SW3
PROG RESET
LED PROG
M1
BOUT
M2
SW3
PROG RESET
PROG
a
L
Page 9 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Technical features
Type 001CS2PLCO
Power supply [V AC] 16-18
Consumption [mA] 250
Consumption in stand by [mA] 100
Storage temperature [°C] -25 ÷ +70
Operating temperature [°C) -15 ÷ +50
IP Rating [IP] 54
Standard video
PAL/NTSC
Resolution [pixel] 680x512
Minimum lighting [LUX] 1
Features L
Terminal board a
BOUT Riser
+Power supply 16-18 VDC
Terminal board
Earth
Door lock release button (NA)
Solenoid lock
12 V 1 A max
PROG key and PROG LED
Programming key and LED (see 'Programming' paragraph).
The PROG LED can take on the following states:
O
On
Slow ashing
Quick ashing
Adjustments
loudspeaker audio
microphone audio
Solenoid lock 1-10 s. (default 1 s)
Personalized labels, dimensions
53x33x0,3 mm53x13x0,3 mm
Accessories K
001DC00EGMA11 single button a,
001DC00PLACO01 Wall roof ,
Recessed box 001DC00PLCO03 ,
Recessed frame 001DC00PLACO02 .
M1
BOUT
M2
SW3
PROG
RESET
PROG
M2M1
+
VLS/300
B
B
NO
C
+
001DC002AC
001DC005AC
M
SW3
PROG RESET
PROG
SW3
PROG RESET
PROG
>3’
<6’
a
SW3
PROG RESET
PROG
M1
BOUT
PROG
M2
M1
BOUT
PROG
M2
A
beep
Page 10 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Programming the call keys. Press the door lock release and AUX2 buttons. On the entry
panel, press the call key to associate with the internal extension : an acoustic signal will conrm
that the setting was stored. Hang up the receiver again. Repeating the same operations for the other
extensions.
Accessing programming. Press the PROG button a for at least 3 seconds and release it (within 6
seconds) as soon as the PROG LED comes on and the backlighting on the buttons ashes as shown in
gure . If the PROG LED does not come on, this shows a fault. Check the connections and go back
to programming.
Programming button type. Press the rst button on the entry panel in the position marked /A
until the backlit LEDS stop ashing and remain lit.
Programming
The kit is pre-congured to manage a single call originating from a single entry panel. One or more receivers answering the same call can be added, by
following the below “Call button programming procedure.
Initial programming
Connection example M
SW3
PROG RESET
PROG
<1’
SW3
PROG RESET
PROG
SW3
PROG RESET
PROG
<1’
M1
BOUT
PROG
M2
SW3
PROG RESET
PROG
>3’
<6’
SW3
PROG RESET
PROG
>3’
<6’
a
beep
SW3
PROG RESET
PROG
M1
BOUT
PROG
M2
Page 11 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Exiting programming. Briey press the PROG button : the PROG LED goes o. N.B. If no action is
performed, the procedure will automatically end after 30 minutes.
Programming button type. At the “Programming Call Buttons” stage, press the PROG button for at
least 3 seconds and release it (within 6 seconds) as soon as the PROG LED comes on and the backlighting
on the buttons ashes as shown in gure , entring the “Programming button type” procedure.
Press the rst button on the entry panel in the position marked until the backlit LEDS stop ashing
and remain lit.
At the end, to exit programming, briey press the PROG button : the PROG LED goes o. If no action
is performed, the procedure will automatically end after 30 minutes.
Programming the call keys. Press the door lock release and AUX2 buttons. On the entry
panel, press the call key to associate with the internal extension : an acoustic signal will conrm
that the setting was stored. Hang up the receiver again. Repeating the same operations for the other
extensions.
Accessing programming. Press the PROG button a for at least 3 seconds and release it (within 6
seconds) as soon as the PROG LED ashes and the backlighting on the buttons comes on as shown in
gure . If the PROG LED does not come on, this shows a fault. Check the connections and go back
to programming.
Reprogramming procedure
Exiting programming. Briey press the PROG button: the PROG LED goes o.
N.B. If no action is performed, the procedure will automatically end after 30 minutes.
SW3
PROG RESET
PROG
>8’
<11’
a
SW3
PROG RESET
PROG
M1
BOUT
SW3
PROG RESET
PROG
M2
3 beep
<1’
M1
BOUT
SW3
PROG
RESET
PROG
M2
M1
BOUT
SW3
PROG
RESET
PROG
M2
a
Page 12 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
To deactivate the intercom function, you simply have to disconnect the SW3 jumper a; by doing this,
programming of the intercom system is also inhibited.
To re-activate this same function, simply re-insert the SW3 jumper .
Disabling the intercom function
With the jumper SW3 connected, press the PROG button for at least 8 seconds and release it (within
11 seconds) a as soon as the PROG LED ashes and the backlighting on the buttons comes on as
shown in gure .
To enable the intercom function, go to the internal extension that you want to program and press the
call button to be used to intercom call it: an acoustic signal will conrm the programming . Continue
by repeating the same operations for all the other internal extensions to be included in the intercom
group. At the end, briey press the PROG button .
N.B. If no action is performed, the procedure will automatically end after 30 minutes.
yOnce an internal extension has been included in an intercom group through the assignment of
a call button, it can no longer be excluded from the group. If you want to change the call button
for an internal extension that is already programmed as intercommunicating
or add new internal extensions to the group, simply repeat the sequence of steps described for
“Programming an intercom group”.
Programming an intercom group
y Programming of the intercom group must only take place AFTER assigning a call button to all the extensions.
a
a
 
001CS2PLCO
+
BOUT
-
-
-
M1
+
M2
M2
A
001DC01LUXO
CL.RESM/S
001DC002AC
+
BOUT
-
+
-
M1
LOCAL
BUS
001CS2PLCO
+
BOUT
-
-
-
M2
+
M2
M1
001DC002AC
A
001DC01LUXO
CL.RESM/S
+
BOUT
-
+
-
M1
LOCAL
BUS
001DC01LUXO
CL.RESM/S
+
BOUT
-
+
-
M1
LOCAL
BUS
001DC01LUXO
CL.RESM/S
+
BOUT
-
+
-
M1
LOCAL
BUS
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
Page 13 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Connection examples
001CS2PLCO
2
12
OUT
SW2
SW4
SW3
001DC006AC
34
IN
SW0
+
BOUT
-
M1
001DC002AC
A
+
M2
-
-
M2
1
001DC01LUXO
CL.RESM/S
12
001DC01LUXO
CL.RESM/S
+
BOUT
-
+
-
M1
LOCAL
BUS
2001DC01LUXO
CL.RESM/S
+
BOUT
-
+
-
M1
LOCAL
BUS
+
BOUT
-
+
-
M1
LOCAL
BUS
1
001DC01LUXO
CL.RESM/S
+
BOUT
-
+
-
M1
LOCAL
BUS
+
BOUT
-
M1
-
-
M2
+
-
-
11
10
7
2
2
7
10
11
001DC01LUXO
CL.RESM/S
+
BOUT
-
+
-
M1
LOCAL
BUS
001CS2PLC0001DC011AC
CAME GATE
10
11
7
2
+
001DC011AC
Page 14 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Lb
La
N° Master N° Slave
001DC006AC
Lc
001CS2PLCO
001DC002AC
001DC011AC
Page 15 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Distances
VCM/1D VCM/2D UTP/CAT 5 2x2,5mm2
La+Lb ≤100 m ≤30 m
Lc ≤25 m ≤60 m
L1, L2, L3 ≤100 m
L1+L2+ L3 ≤300 m
La+Lb+L1(L2, L3) ≤150 m
La+Lb+L1+L2+L3 ≤600 m
VCM/1D UTP CAT5
N° Master 1 1
N° Slave 7 1
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 16 - Manual FA00963-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME LUXO, PLACO Installation guide

Type
Installation guide

CAME LUXO, PLACO is a high-quality video entry kit that provides a secure and convenient way to communicate with visitors at your door. The kit includes a video terminal, a power supply, and a variety of accessories that allow you to customize the system to meet your specific needs.

The video terminal features a 7-inch TFT LCD display that provides clear and detailed images of visitors. The terminal also has a built-in microphone and speaker, so you can communicate with visitors hands-free.

The power supply provides the video terminal with the power it needs to operate. The power supply can be connected to either a 16-18 VAC or a 230 VAC power source.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI