CAME PERLA, PLACO Installation guide

Type
Installation guide
001CS2PLC0 001CS2BNC0
001DC002AC
M2M1
+
VIDEO ENTRY KIT
001CK0002
INSTALLATION MANUAL
EN
English
FA00956-EN
135
99 30
3.5
6.5
243
207
135
99 30
3.5
6.5
243
207
Page 2 - Manual FA00956-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
General warnings
On opening the pack
Read the instructions carefully before starting installation and proceed as specified by the manufacturer;
After removing the packaging, check the condition of the unit;
The packaging items (plastic bags, polystyrene foam etc.) must not be handled by children as they may be dangerous;
General installation instructions
• Installation, programming, commissioning and maintenance of the product must only be performed by qualified technicians who have been properly trained in
compliance with current standards, including health and safety regulations;
Operate in sufficiently lit areas that are conducive to health and use tools, utensils and equipment that are in good working order;
The device must be installed in accordance with the IP degree indicated in the technical features;
If present, do not obstruct the openings or ventilation/heat dispersing holes;
Wiring the devices
The electrical system must comply with current standards in the country of installation;
Before connecting the units, check that the indications on the plate correspond with those of the mains;
Protect units powered with mains voltage using a single pole mains switch with contact separation of at least 3 mm;
Wires belonging to cables that are not used must be insulated.
To prevent accidental contact, tighten the mains connection cables and those for the very low voltage signals separately.
Weld the joints and the ends of the wires to prevent malfunctions caused by wire oxidation;
Installation completed
When installation is completed, always check for correct operation of the unit and the system as a whole;
The installer must check that the information required by the user is present and handed over;
Maintenance
Before performing any cleaning or maintenance operation, disconnect the power supply to the device. If the units are mains-powered, disconnect the power using
the switch upstream from the units;
In the case of device failure or malfunction, disconnect it from the power supply and do not tamper with it;
Should the unit be in need of repair, contact only a technical support centre authorised by the manufacturer and always use spare parts provided by CAME S.p.A.
The units must only be used for the purpose for which they were explicitly designed.
Failure to follow the instructions provided above may compromise the unit’s safety.
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
DISPOSAL
Do not litter the environment with packing material: make sure it is disposed of according to the regulations in force in the country where the product is used.
When the equipment reaches the end of its life cycle, take measures to ensure it is not discarded in the environment.
The equipment must be disposed of in compliance with the regulations in force, recycling its component parts wherever possible.
Components that qualify as recyclable waste feature the relevant symbol and the material’s abbreviation.
ADDITIONAL NOTES - SPECIAL VERSIONS FOR THE HEARING-IMPAIRED
The devices feature an induction loop system compatible with hearing aids in the T position (ETS 300381, EN 60118).
Important!
For all other information and technical features of the devices, refer to the instructions enclosed with the product.
Video entry control
Power supply
Video entry phone
Allen wrench
2 plugs and
2 screws with washer
Packaging contents
ACCESSORIES (can be purchased separately)
Dimensions
001DC00EGMA11 Single button
001DC00EGMA12 Single button and
double height
001DC00EGMA13 Double button
LTP Wall roof 001DC00PLACO03 Recessed box
001DC00PLACO02 Recessed frame
1
2
1
2
Ð +
AL B
M/S
CL.RES
1
2 3 4
7
6
5
Page 3 - Manual FA00956-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Installation
Remove the unit from the metal support by sliding it after pressing the plastic button (figure 1).
Fasten the metal support to the round built-in box of Ø 60 mm (figure 2) or to the rectangular box 503 (figure
3-4) using the provided screws and observing the UP indication .
The box must be fitted at a suitable height in relation to the installer. Avoid excessive tightening of the screws.
Once the connections have been made, attach the video terminal to the metal support (figure 5-6).
To release the unit from the metal support, press the plastic hook and lift the terminal (figure 7).
M1
AL Alarm input (1)
+
Doorbell
BBUS line input (not polarised)
(1) Function only accessible if the system features
1 porter station
Technical features
Power supply from BUS: 15-20 VDC
Absorption: 200 mA max (<1 mA stand-by)
Single LED absorption (panic, Ring disabled):
1 mA
Dimensions: 170x145x30.9 mm
Storage temperature: -25 °C +70 °C
Operating temperature: 0 °C +35 °C
IP degree: IP 20
Standard video: PAL/NTSC
Display: LCD TFT colour 3.5”
Terminal boards
001CS2BNC0
43,5
45
7,5 57
70
106
A
B
64,5
70
145
A
B
500 mm
1080 mm
77¡
94¡
800 mm
500 mm
163,5 mm
43,5 mm
H= 165 cm
(HAUTEUR
CONSEILLƒ)
500 mm
1080 mm
77¡
94¡
800 mm
500 mm
163,5 mm
43,5 mm
M2M1
+
1
1
2
5
6
3
4
Page 4 - Manual FA00956-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
1
Power supply: 230 VAC 50-60 Hz
Current absorbed Imax
200 mA
AC
AC
Power dissipated: 10 W max
Rated power supply: 18 VDC 1 A-0.5 A 1’/3’
Dimensions: 4 DIN
Storage temperature: -25 °C + 70 °C
Operating temperature: 0 °C +35 °C
IP degree: IP 30
Wall mounting
With the Allen wrench, unscrew the blocking screws and remove the plate (figure 1). Fix the given plugs and
screw the entry panel (figure 2-) at the desired height considering the position of the lens of the camera
(figure 3).
Run the sheath with the system conductors as shown in figure 2. Extract the plastic terminal cover and wire
the connections (figure 4).
Once all the connections have been made, re-insert the terminal covers. Install the front plate (figure 1).
Recessed installation
Install the recessed box at the desired height considering the position of the lens of the camera (figure 3), but
in advance, run the hose with the system conductors through one of the breaking points (figure 5 point A).
During installation of the recessed box it is possible to avoid any deformation by using the provided spacer
(figure 5 point B).
With the Allen wrench, unscrew the blocking screws and remove the entry panel plate (figure 1).
Introduce the cable connections in the special hole (figure 2) and fix the entry panel on the frame as shown in
figure 6; extract the plastic terminal cover and wire the connections (figure 4). Once all the connections have
been made, re-insert the terminal covers.
Install the front plate (figure 1).
Installation
The power supply must ALWAYS be installed vertically.
The unit can be installed on a DIN guide (EN 50022) in a special electrical panel.
For the overall dimensions, see fig. 1.
Provide sufficient ventilation if the power supply is installed in a container.
Terminal boards
M1
~230 V mains
~
M2
+18 VDC power supply (*)
(*) The unit is protected against overloads and
short circuits.
H= 165 cm
(RECOMMENDED
HEIGHT)
001DC002AC
001CS2PLC0
001DC002AC
001CS2PLC0
M1
BOUT
M2
SW3
PROG
RESET
PROG
M2M1
+
001DC005AC
B
B
NO
C
+
NO
C
M1
BOUT
M2
SW3
PROG RESET
PROG
001DC002AC
c
f
d
g
b
h
a
X 5
beep
i
X 5
beep
e
Page 5 - Manual FA00956-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Technical features
Entry panel
Power supply: 16-18 VDC
Absorption: 250 mA max (100 mA stand-by)
Dimensions: 99x207x30 mm
Storage temperature: -25 °C +70 °C
Operating temperature: -15 °C +50 °C
IP degree: IP 54
Video camera
Standard video: PAL/NTSC
Resolution: 680x512 pixels
Minimum lighting: 1 LUX
OPTIONAL:
Bus module
2 auxiliary exits
Relay 1
Relay 2
Terminal board
M1
BOUT Bus
+Power supply
16-18 VDC
M2
Earth
Door release
button (NO)
Electric lock
12 V 1 A max
Functions of the terminal boards
Adjustments
speak audio
microphone audio
electric lock 1-10 s. default 1 s
1- Going into Programming.
Press button 5 times in 5 secs a.
A short beep confirms that you have entered programming mode.
2- Programming the melody associated with a call from the entry panel.
To listen to the melodies in sequence, press key b.
To select the melody and exit programming, press key c.
To select the melody and continue with programming, press key d.
3- Programming the melody associated with a call from the front door.
To listen to the melodies in sequence, press key e.
To select the melody and exit programming, press key f.
To select the melody and continue with programming, press key g.
4- Programming the number of rings for the call.
Press key h as many times as you want it to ring (from 1 to 6 rings). Three seconds after the last press of the
key the call selected for the chosen number of rings will be played back.
To exit programming, press key i.
See the entry panel documentation for call programming.
Setting melodies
All the programming stages described below must be carried out in sequence:
CL.RES CL.RES CL.RES
1 2 3
001DC006AC
MASTER SLAVE
M/S M/S
001DC002AC
2
2
2
001DC002AC
2
N° Slave
Lb
La
Lc
N° Master
001DC006AC
001DC002AC
AB
Page 6 - Manual FA00956-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Distances
Connection examples
MAX N°
MASTERS
MAX N°
SLAVES
2x1 mm22 3
UTP/CAT5 1 2
Distances
2x1 mm2UTP/CAT 5 2x2.5
mm2
La+Lb ≤100 m ≤100 m
Lc ≤25 m ≤60 m
Bus end resistance jumper: Master/slave selection jumper
If multiple monitors are
called in parallel, they
will all ring, but the
video will only be acti-
vated in the receivers
configured as Masters
100 m max
2x1 mm2
001DC002AC
A
+
M2
1.1
001CS2BNC0
M1
AL
B
+
CL RES M/S
1.3001CS2BNC0
M1
AL
B
+
CL RES M/S
1.2
001CS2BNC0
M1
AL
B
+
CL RES M/S
Automatisme
CAME
Relais
12Vcc
2
7
230 V
001CS2PLC0
-
-
+
BOUT
-
M1
M2
001CS2PLC0
Automatisme
CAME
Relais
12Vcc
+
BOUT
-
-
-
+
M2
001DC002AC
A
230 V
CL RES M/S
M1
AL
B
+
001CS2BNC0
M2
M1
2
7
A
B
Page 7 - Manual FA00956-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 8 - Manual FA00956-EN - vers. 1 - 11/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

CAME PERLA, PLACO Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI