Mizu 9512144 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Mizu 9512144 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Mizu Drift Handshower With Water Inlet Wall Bracket (3*)
Plumbing Socket Set
Wrench
Tools Required
Page 01
Installation Instructions
It is recommended that this product be installed by a qualified licensed plumber to AS/NZS 3500.
Tools Required
Main Body x1 Cover Plate x1 Handle x1
A B C D E F
Screw x2 Anchor x2 Allen Key x1
F
Allen Key x1
Main Body x1 Cover Plate x1 Handle x1 Screw x2 Anchor x2 Allen Key x1
A B C D E F
Wrench Plumbing Socket Set
Diagram
TBA
Number Part
MIZU SILK SHOWER MIXER - 9510746
Quantity Chrome Matte
Black
Brushed
Nickel
Brushed
Gun
Metal
1-3
4
5
6-8
9
Mixer Handle Set Complete 2265003
2265020
2265024
2265016
2265002
2265019
2265023
2265015
2265001
2265018
2265022
2265014
2265000
2265017
2265021
2265013
1
Concealed Wall Mixer Cap
Concealed Wall Mixer Cartridge Sleeve
Concealed Shower Mixer Plate Set
Allen Key 2.5mm
1
1
1
1
x
x
x
x
x
x
xxx
x
x
x
x
x
x
x
x
x
x
x
*Mizu Drift Handshower with Water Inlet Wall Bracket (3*)
*
*
ABCD
D
C
B
A
1
2
3
4
1
2
3
4
2
徿6
浾媨
憗0
Éè鏈¼Æ Íõ寢¹ 憇憉夐徴忇
У鏈¶Ô
Éó鏈ºË
±ê×¼»¯
逩袪屢踶釠蹅逷鳮D
Åú鏈×¼
Áã¼þÃû³Æǽ³ö»¨È÷²å×ùÌ××°
ͼֽ±àºÅ
徺巗殎曫憄穭C
²Ä鏈鏈ÁÏ 窌M °æ鏈鏈±¾ A
ÀíÂÛÖØÁ¿㝫㤥
ÀíÂÛ±íÃæ»ý㝧䤺]
»æͼµ¥Î» 䦎
±È鏈鏈Àý 忋3
µÚ鈴錢³;¹²鈴錢³
±ê¼Ç ÐÞ鏈¸ÄÄÚÈÝ Éè鏈¼Æ
»æͼÊÓ½Ç
ÈÕÆÚ
鏈鏈鏈鏈鏈鏈塹ØÒª³ß´ç
鏈鏈鏈鏈鏈槍îÖØÒª³ß´ç
δע³ß´ç¹«²î δע½Çȹ«²î
»ù±¾³ß´ç庽¼a¡Ü6 楍¼a¡Ü捸 捸£¼㶮Ü1憇 徾庽¼a¡Ü敄0 巕曏
¹«²îÖµ 巕1 巕2 巕3 巕5
ÐòºÅ Áã¼þ±àºÅ Áã¼þÃû³Æ²ÄÏ ÊýÁ¿ ±¸×¢
1 憇梬徾梲涋巘訷鈴媨䤺陊絸Òø²¹Ü²»¿ÉÉìËõ»¨È÷Èí¹Ü倣鄫ÏÖ¤)傿ÓÍ·´øOÐÍȦ)窌M 2
2 憈巗忂巪巣憓徺巗浽掋湼ý¹¦ÄÜËÜÁÏÊÖÎÕ»¨È÷(ºÚÉ«ÅçÆá)穭S 1
3敄巘奌朰曥巗怚1 蛦9 1
4ú㐯巘浽夐捸巗㬼 蛦9 1
5 踸巗捿奌朰徾巗巘㬻 蛦9 1
6 鳫巗梮巗巘㬻 蛦9 1
7 鳮巗敒巗帹1 蛦9 1
8 鳮巚巟巗帹2 蛦9 1
9 㙅巜巪夐捸巗怚2 蛦9 1
¥鳮巘徾夐捸巗怚2 蛦9 1
ǽÕÖ Ç½ÕÖ蛦9 1
Mixer must be installed to the requirements of AS/NZS 3500 by a qualified plumber. The mixers are
factory tested and sealed so as to give the best performance.
of 02
Mizu - Drift Handshower With Water Inlet Wall Bracket (3*)
of 02
Mizu - Drift Handshower With Water Inlet Wall Bracket (3*)
11
13
12
ŸIn a typical installation, the mixer is mounted on the timber/metal
noggin and secured with screws (not provided).
ŸShower Mixer Outlet (1) must always face up toward the shower.
Connect the mixer (1) to hot and cold water supply.
ŸPressure check all connections. Leaking joints are not covered by the
warranty.
Installation
Connect mixer (1) to hot and cold water supply (3).
Pressure check all connections.
Leaking joints are not covered by the warranty.
1
1
3
3
Note: This tap is suitable for high pressure applications
where both hot and cold water supply pressures are at
150kpa or above.
All connections must be checked for leaks and is the
responsibility of the installer to ensure a waterproof
seal has been achieved.
Flush out new pipework prior to connecting the
Handshower.
During installation protect the exposed finish surface
by using the plastic protective cover provided. Please
pay attention to the minimum/maximum depth.
Waterproofing and sealant materials are used to seal
against moisture or water penetration to ensure
integrity of the wall sheet lining structure. It must not
interfere with the removal of the protective cover and
installation of the mixer trim components. The
installing plumber is responsible for waterproofing
the shower mixer area penetrations as per AS3740.
Ø46
1
2
Waterproofing membrane (See installation Note 2)
Important: Waterproofing materials must not contact this surface.
Lining Board
‘O’-ring
Finished wall//tile face 50-60mm
G1/2" BSP INT
G1/2" BSP INT
Ø50 Tile Penetration
Outlet to bath,
basin or shower
1
2
Waterproofing membrane (See installation Note 2)
Important: Waterproofing materials must not contact this surface.
Lining Board
‘O’-ring
Finished wall//tile face 50-60mm
G1/2" BSP INT
G1/2" BSP INT
Ø50 Tile Penetration
Outlet to bath,
basin or shower
Page 02
1.
2.
1
Ø50 Tile Penetration
2
Important: Waterproofing/sealant materials must not contact 1 & 2.
Waterproofing membrane
Wall Sheet lining
Finished wall surface 52-77.5mm
G1/2" BSP INT
G1/2" BSP INT
Outlet to Shower,
Bath or Basin
‘O’-ring
52-77.5mm
Finished wall surface
1
2
52-77.5mm
Finished wall surface
G1/2" BSP INT
‘O’-ring
G1/2" BSP INT
Outlet to Shower,
Bath or Basin
Ø50 Tile Penetration
Wall Sheet lining
Waterproofing membrane
Important: Waterproofing/sealant
materials must not contact 1 & 2.
Important: Waterproofing/sealant
materials must not contact 1 & 2.
Waterproofing / sealant materials must be clear of the
protective cover (2) and the surface it protects (1) to
allow for removal of the protective cover and mixer
trim set for fit off.
1.
2.
3.
4.
5.
*If retrofitting, unscrew your old shower anti-clockwise to remove.
Clean the exposed threaded water supply and bind clockwise
with thread sealing tape
NOTE: Ensure that male-threaded water supply is no longer than
18±2mm off the finished wall
Fit elbow hose connection (1-8,13,14) to the wall (Hand-tighten
only) ensure the sealing o-ring (12) is tight against the finished
wall.
Ensure that the elbow hose connection is vertical so that the hose
hangs straight down.
Connect the hose (9,10) and handpiece (11) using the washers
supplied (Hand-tighten only).
ŸNOTE: Ensure that the male connection thread is no longer than 18±2mm off the finished wall.
ŸSlide cover Plate (13) opening through the wall Elbow rear (1).
ŸHand-tighten wall Elbow (1) to wall connection thread, ensuring that the hose connection faces downward.
ŸConnect the Hose (9) and Handpiece (11) using the washers supplied (Hand-tighten only).
1
2
We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by
any improper treatment is not covered by the product warranty. Refer to Warranty Conditions
Plumbers, please ensure a copy of the installation
instruction is left with the end user for future reference.
Published 29/11/2022
8
1
14
2
3
4
6
5
7
9
10
ŸIf retrofitting, remove older shower and clean exposed thread
ŸApply a thread sealant.
ŸIf retrofitting, unscrew your old shower anti-clockwise to remove.
ŸClean the exposed threaded water supply and bind clockwise with thread sealing tape.
NOTE: Ensure that male-threaded water supply is no longer than 18±2mm off the finished wall.
ŸFit Elbow Hose Connection (1-8,13,14) to the wall (Hand-tighten only) ensure the Sealing O-Ring (12) is tight
against the finished wall.
ŸEnsure that the Elbow Hose Connection (1-8,13,14) is vertical so that the Hose (9,10) hangs straight down.
ŸConnect the Hose (9,10) and Handpiece (11) using the washers supplied (Hand-tighten only).
This Handshower is suitable for high pressure
Storage Tank and Continuous Flow applications with
a minimum operating pressure of 150kPa and
maximum 500kPa.
Not suitable for Gravity Feed Hot Water Unit
applications.
Maximum hot Temperature 60°C, minimum 1°C.
· NOTE: Ensure that the male connection thread is no longer than 18±2mm off the finished wall.
· Slide cover Plate (13) opening through the wall Elbow rear (1).
· Hand-tighten wall Elbow (1) to wall connection thread, ensuring that the hose connection faces downward.
· Connect the Hose (9) and Handpiece (11) using the washers supplied (Hand-tighten only).
/