5W SOLAR PANEL
41144
SET UP AND OPERATING INSTRUCTIONS
Distributed exclusively by Harbor Freight Tools
®
.
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our website at: http://www.harborfreight.com
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Copyright
©
2008 by Harbor Freight Tools
®
. All rights reserved. No portion of this manual or any artwork
contained herein may be reproduced in any shape or form without the express written consent of
Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein. Tools required for
assembly and service may not be included.
For technical questions or replacement parts, please call 1-800-444-3353.
SKU 41144 For technical questions, please call 1-800-444-3353. Page 2
CAUTION
Read Rules for Safe Operation and
Instructions Carefully.
SAVE THESE
INSTRUCTIONS.
Safety Symbols
In this manual, on the labeling,
and all other information provid-
ed with this product:
This is the safety alert
symbol. It is used to alert
you to potential personal
injury hazards. Obey all
safety messages that
follow this symbol to avoid
possible injury or death.
DANGER indicates
a hazardous
situation which, if not
avoided, will result in death or
serious injury.
WARNING
indicates a
hazardous situation which, if
not avoided, could result in
death or serious injury.
CAUTION, used
with the safety
alert symbol, indicates a
hazardous situation which, if
not avoided, could result in
minor or moderate injury.
NOTICE is used to
address practices
not related to personal injury.
CAUTION, without
the safety alert
symbol, is used to address
practices not related to
personal injury.
Additional Safety Instructions
Maintain labels and nameplates on 1.
the tool. If unreadable or missing,
contact Harbor Freight Tools for a
replacement.
Do not run Power Cord under car-2.
peting. Do not cover cord with throw
rugs, runners or similar coverings. Ar-
range cord away from trafc area and
where it will not be tripped over.
Use only in dry environments. Do not 3.
use in bathrooms, laundry area, near
sinks or other sources of water.
This product is not a toy. Keep it out 4.
of reach of children.
WARNING: Handling cord on this 5.
product will expose you to lead,
a chemical known to the State of
California to cause cancer, and birth
defects or other reproductive harm.
Wash hands after handling. (Califor-
nia Health & Safety Code § 25249.5,
et seq.)
The warnings, precautions, and in-6.
structions discussed in this instruction
manual cannot cover all conditions
and situations that may occur. It must
be understood by operator that com-
mon sense and caution are factors
which cannot be built into this prod-
uct, but must be supplied by operator.
This product is not water-proof, so 7.
keep out of the rain.
SKU 41144 For technical questions, please call 1-800-444-3353. Page 3
SPECIFICATIONS
Materials
-Amorphous Cells
-Anti-reflective
High Transparency
Tempered Glass
-Foil Backing
Finish
Anodized Aluminum
Alloy Frame
Panel Dimensions 12"W x 18"L x 1"H
Cell Dimensions
5" square cells
arranged in 4 by 9 cell
grid
Peak Voltage 5 watts
Nominal Voltage 12 VDC
Cable w/MC Connector 2
Weight 3.45 lb.
UNPACKING
When unpacking, make sure that the
item is intact and undamaged. If any parts
are missing or broken, please call Harbor
Freight Tools at the number shown on the
cover of this manual as soon as possible.
Save This Manual
Keep this manual for the safety warn-
ings and precautions, assembly, operat-
ing, inspection, maintenance and cleaning
procedures. Write the product’s serial
number in the back of the manual near the
assembly diagram (or month and year of
purchase if product has no number). Keep
this manual and the receipt in a safe and
dry place for future reference.
REV 09e
SKU 41144 For technical questions, please call 1-800-444-3353. Page 4
MOUNTING
Read the ENTIRE RULES FOR
SAFE OPERATION section at
the beginning of this manual
including all text under
subheadings therein before set
up or use of this product.
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION OR ELECTRIC
SHOCK:
Before assembly, cleaning or
adjustment, make sure the
switch is turned off, the cord
is unplugged, and the unit has
cooled.
Note: For additional information regarding
parts listed, refer to Assembly Dia-
gram at back of manual.
Mount on a wall.
Attach sheet metal brackets securely 1.
to adjustable braces in the back of
the framing with the eight supplied
bolts (two per bracket) through the
counter-sunk holes. (See Fig. 1.)
Once brackets are in place, place the 2.
Panel onto the mounting surface and
mark where the screws will go.
Note: Verify that installation surface has
no hidden utility lines before drilling or
driving screws.
Drill the mounting holes with the 3.
proper size drill bit.
Plug the white plastic cable plug into 4.
the connection on the back of the
panel.
WARNING: Handling the cord on this
product will expose you to lead,
a chemical known to the State of
California to cause cancer, and birth
defects or other reproductive harm.
Fig. 1
Sheet Metal
Mounting Plate
(3)
SKU 41144 For technical questions, please call 1-800-444-3353. Page 5
Wash hands after handling. (Califor-
nia Health & Safety Code § 25249.5,
et seq.)
It is advisable to clamp the cable a.
end clamps onto a non-conductive
material such as plastic or wood to
keep them from touching.
With the help of an assistant (if nec-5.
essary) to hold the Panel steady and
in place, drive the supplied screws
through the smaller mounting holes
and into the holes drilled into the
mounting surface.
The solar panel is now ready to be at-6.
tached to a battery for recharging.
Mount on horizontal surface
The Solar Panel (1) can be placed 1.
at on the ground or oor, or placed
at an angle using the two supplied
threaded Mounting Stand Rods (6).
(See Fig. 2.)
Although it is not necessary, the a.
cable plug can be plugged into the
electrical connection with the clamps
attached to non-conductive material.
Placing at an angle enables the panel 2.
to make most efcient use of sunlight.
The Mounting Stand Rods (6) thread a.
into two bolts built into the back of
the frame at the opposite end from
the connector.
The Mounting Stand Rods can be 3.
moved closer to the center of the
frame to give a greater angle if de-
sired.
With the panel placed at the desired 4.
location, the cable clamps can now
be attached to the proper battery
terminals.
Fig. 2
Mounting Stand Rods (6)
SKU 41144 For technical questions, please call 1-800-444-3353. Page 6
OPERATION
Read the ENTIRE RULES FOR
SAFE OPERATION section at
the beginning of this manual
including all text under
subheadings therein before set
up or use of this product.
Being careful about the proper polar-1.
ity, plug the cable clamps onto the
corresponding terminals on the bat-
teries.
INSPECTION AND
MAINTENANCE
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION OR ELECTRIC
SHOCK:
Before Solar Panel inspection
or maintenance, make sure
the Solar Panel’s cord is
unplugged, and the unit has
cooled completely.
TO PREVENT SERIOUS
INJURY FROM APPLIANCE
FAILURE:
Do not use damaged Solar
Panels. If abnormal noise or
vibration occurs, have the
problem corrected before
further use.
Periodically inspect the general 1.
condition of the Solar Panel. Check
for broken glass, damaged electrical
wiring or any other condition which
may affect its safe operation
Do not use Solar Panels that are 2.
damaged in any way.
Do not leave the Panel unattended 3.
and attached to any appliance, light
or motor which may cause injury or
damage if it operates without supervi-
sion.
Keep the Solar Panel clean. Wipe it 4.
occasionally with a damp cloth using
mild detergent. Do not use abrasive
cleaners. Dirt on the glass will reduce
the capacity of the panel to receive
sunlight.
SKU 41144 For technical questions, please call 1-800-444-3353. Page 7
PARTS LIST AND ASSEMBLY DIAGRAM
Part Description Qty.
1
Solar Panel 1
2
12' Cable w/Battery Clamps 1
3
Sheet Metal Mounting Plates
(see Fig. 1).
4
4
1/2" Screws 4
Part Description Qty.
5
Mounting Bolts 8
6
Mounting Stand Rods (see
Fig. 2).
2
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES
ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED
TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS
OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT
ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED
TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF
HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT
OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Record Product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and are not available individually as
replacement parts.
Battery Clamps
Aluminum Frame
Cable Plug
Cable (2)
Solar Panel (1)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Chicago Electric 41144 Set Up And Operating Instructions Manual

Type
Set Up And Operating Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI