Drive 13008, Deluxe, Deluxe Tilt-Top Overbed Table Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Drive 13008 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1. Remove contents from packaging and lay top board
upside down on flat surface with Mounting Tube (5)
facing upward. See Fig. 2.
2. Take the Column Assembly (2) and place Trip Lever (3)
on top of Trip Rod and secure with Bolt and Nut (4)
See Fig. 1.
3. Remove Triangle Knob (16) and Spacer (17) and
remove Inner tube (6) from Outer tube (18). See Fig. 3.
4. Insert Outer tube (18) on Column Assembly through
Mounting Tube (5) on table top. Then insert Inner
tube (6) through Mounting Tube (5). See Fig. 4.
5. Replace Triangle Knob (16) and Spacer (17) and
secure by tightening the knob.
Assembly Instructions
Drive Medical
TILT TOP TABLE - 13008
6. Install two Casters With Lock (8) into Base (7) which
connects to Column Assembly (2). Install two
Non-Locking Casters (9) into base opposite Column
Assembly (2). See Fig. 5.
7. Install two Bolt Sleeves (10) into upside down Base (7)
and then position two Bolts (12) through Bolt Plate
(11) and into Bolt Sleeves (10). Position Base (7) over
Column Assembly (2) and thread bolts into boom of
Column Assembly (2) and tighten using 16mm wrench.
See Fig. 6.
8. Turn the table upright and stand on casters.
9. CAUTION: This step must be completed last to
prevent damage to the spring loaded mechanism.
Remove the Black Screw (13) in the Column Assembly
(2) collar labeled “Remove for Assembly” and replace
it with the Chrome Screw (14) contained in hardware
package. Do not remove Chrome Screw labeled “Do
Not Remove”. See Fig. 7 and Fig. 8.
FIG. 2
5
1
FIG. 1
4
3
2
FIG. 4
17
16
6
18
2
FIG. 7
Remove 13
FIG. 8
Insert 14
WARNING
FOR SAFETY – DO NOT REMOVE BLACK SCREW (13) ON COL-
UMN ASSEMBLY (2) UNTIL THE TABLE IS FULLY ASSEMBLED AND
STANDING IN UPRIGHT POSITION. AFTER REMOVING BLACK
SCREW, REPLACE WITH CHROME SCREW (14) INCLUDED IN
HARDWARE PACKAGE.
THE BOTTOM CHROME SCREW WITH THE “DO NOT REMOVE”
LABELSHOULDNEVERBEREMOVEDASITWILLDAMAGETHE
UNITANDVOIDYOURWARRANTY
12
11
2
FIG. 6
10
1
7
8
9
FIG. 5
Column end of base
with 2 holes
7
FIG. 3
2
18
17
6
16
Lifetime Limited Warranty
Your Drive branded product is warrantied to be free of
defects in materials and workmanship for the lifetime of
the product for the original consumer purchaser.
This device was built to exacting standards and care-
fully inspected prior to shipment. This Lifetime Limited
Warranty is an expression of our confidence in the materi-
als and workmanship of our products and our assurance to
the consumer of years of dependable service.
This warranty does not cover device failure due to owner
misuse or negligence, or normal wear and tear. The war-
ranty does not extend to non-durable components, such as
rubber accessories, casters, and grips, which are subject to
normal wear and need periodic replacement.
If you have a question about your Drive device or this war-
ranty, please contact an authorized Drive dealer.
© 2014 Medical Depot, Inc. All rights reserved.
Drive is a trademark of Medical Depot, Inc.
Port Washington N.Y. 11050 USA Made in China
Assembly Precautions
This Overbed Table utilizes a high-tension spring loaded mech-
anism to raise the table, DO NOT remove #13 Black Screw and
replace with #14 Chrome Screw until table is fully assembled.
DO NOT over tighten bolts, screws or use power tools when
assembling this product.
Important Warnings
Please follow all instructions and warnings to avoid hazardous
situations that can result in property damage and/or patient/
resident/staff/caregiver injury and/or death.
Inspect the product for damage and loose hardware before each
use. DO NOT use the product if it appears to be damaged or
unstable and DO NOT modify the product in any way.
Intended Use
This product is designed for use as a movable patient/resident
table top surface for reading, eating, or keeping small personal
items such as glasses, telephone, or books within easy reach.
This product is designed for indoor use ONLY within close prox-
imity of skilled caregivers. It is not designed to hold electrical
items (such as televisions, computer monitors, coffee pots, etc.)
and should not be used near open flames and excessive heat.
Maximum weight limitation for this product is 50 lbs (22 kg.);
weight should be evenly distributed over the table top surface
while at the lowest usable height to help maintain a stable con-
dition.
DO NOT overload the product as that could result in breakage,
as well as damage to property and/or serious injury.
Use ONLY as directed for its intended use. This product should
NOT be used: as a sleep surface; as a walker or mobility aid to
assist a person in walking, siing down or standing up; to prevent
or brace a person’s fall; or to help transport persons or items.
Parts List
1. Table Top
2. Column Assembly
3. Trip Lever
4. / - 20 x 2 /” Bolt & Nut
(1 each)
5. Mounting Tube
(Top to Column Assembly)
6. Inner Tube
7. Base
8. Casters with Lock (2 ea)
9. Casters without Lock (2 ea)
10. Bolt Sleeves (2 each)
11. Bolt Plate
12. / - 15 x 2” Bolts (2 each)
13. Black Screw
14. Chrome Screw (to
replace #13 black screw)
15. Trip Rod /” x 20 /”
(inside Column Assembly)
16. Triangle Knob
17. Spacer
18. Outer Tube
1. To raise top to desired height, apply light pressure
upward at any point under table.
2. To lower, squeeze trip lever (3) up towards top and
push down at column to desired height. Do not put
pressure on tabletop end that is opposite the column.
Column assembly will lock upon release of trip lever.
3. To tilt, turn Triangle Knob (16) counter-clockwise to
loosen. Set to desired angle and then turn knob (16)
clockwise to tighten.
Operating Instructions
11
10
12
4
14
4
3
HARDWARE
16
17
3
18
13
14
2
7
8
12
11
10
9
6
4
5
1
/