Sanela SLP 32RB Mounting instructions

  • Hello! I've reviewed the mounting instructions for the SANELA SLP 32RB and SLP 33RB automatic urinal radar flushing systems. This document details the system's functions, including adjustable flushing and using times and automatic flushing after 6 hours of non-use. I'm ready to answer any questions you have about installation or usage!
  • What is the minimum use time before the flush activates?
    What is the adjustable range for the flushing time?
    What is the adjustable range for the using time?
    What happens after 6 hours of non-use?
    When does the electronics switch on?
ISO 9001:2000
150 mm
80 mm
AA alkaline
AA alkaline
AA alkaline
AA alkaline
SLP 32RB - Code Nr. 11327, SLP 33RB - Code Nr. 11337
Supplied equipment
Installation
6
4
min 150 mm
8
1
2
3
75
length of
vertical plumbing
1 - water inlet to the urinal
2 - electronics with radar senzor
3 - outlet fiting with sealing
4 - waste outlet Ø 50 mm
5 - box with bateries
6 - urinal
7 - waste siphon
8 - electromagnetic valve
Ø 50 mm
waste
outlet
Ø = 14 Ø = 14
150
150
water inlet
SLP 32RB = 200
SLP 33RB = 240
SLP 32RB = 420
SLP 33RB = 375
SLP 32RB = 180
SLP 33RB = 215
SLP 32RB = 585
SLP 33RB = 660
1
Mounting instructions
Automatic urinal radar flushing system SLP 32RB, SLP 33RB
Function
minimum use time 10 sec. after 6 hours non use
Properties
flushing time 0,5 - 15,5 sec using time 6 - 15 sec
Recommended accessories
SLD 04 Remote control for the parameters adjustment
AC
EG
B
D
F
H
19
17 mm
9
A
10 sek
150 mm
150 mm
B
2
A
B
D
3/4“
C
E
H
F
I
G
3
A
7
8
4
5
A
B
C
B
C
A
6
10
_+
AA alkaline
AA alkaline
AA alkaline
AA alkaline
_
+
ATTENTION !
!! !!
4 pcs alkaline batteries AA 2700 mAh
( Battery life approx. 2 years at 4000 uses monthly )
Electronics is switched on 15 minutes after the insertion of batteries.
One flush starts automatic immediate after that.
TEST
10 sek
!! !!
Electronics is switched on 15 minutes after
the insertion of batteries. One automatic flush
starts immediate after that.
BEEP
20 min.
Service
It is recommend to check up the sifter of electromagnetic valve once a year, because of there is a possibility that valve could be fouled up.
Checking of tightening of screw conections and connectors contact surfaces is also recommend once a year.
All stainless steel components should be cleaned only by water soap and soft rag. It is strictly forbidden to use aggressive and abrasive
cleansers!
Producer assures that this product has declaration of conforminty in accordance with the regulation 73/023/EEC and 89/336/EEC.
/