CASH PBE-3
ADJUSTING SCREW REPAIR KIT INSTALLATION INSTRUCTIONS
Before installation, these instructions must be fully read and understood.
WARNING
Failure to follow these directions could lead to
bodily injury or death.
CAUTION
Remove the Valve from the system and place the
valve in the recommended test fixture to achieve
proper set point. See Figure 1.
Be certain all liquid is removed from the vessel,
and the pressure is vented to 0 psig before
removing Valve from the system.
TOOLS NEEDED:
• 1/2”,3/4”,&7/8”Open-EndWrenches
• Pressuregaugescapableofproviding
adequateresolutionforValvesetpressure
adjustment.
ADJUSTING SCREW INSTALLATION
INSTRUCTIONS
1. Removeallpressurefromsystemandvent
pressureto0psig.DisconnectPBE-3from
system.
2. InstallPBE-3ValveAssemblyinatest
fixture,pertheschematicinFigure1.Using
1/2”wrench,unscrewtheoldAdjusting
Screwwhileusingthe3/4”wrenchtokeep
theBushingfromturning.
3. ThreadthenewAdjustingScrewintothe
Bushinguntilyoufeelresistance.
IMPORTANT
Apply an inlet pressure to the Valve that is only
10psig above the desired set pressure. Use
gaseous Nitrogen or dry air only!
4. Usingthe1/2”wrench,turntheAdjusting
Screwclock-wiseuntilthedesiredset
pressureisindicatedontheOutletPressure
Gauge.TheBushingmayneedtobekept
fromturningbysecuringwiththe3/4”
wrench.
5. IftheOutletPressureGaugedoesnot
correspondwithwhatisindicatedon
theSleeveontheAdjustingScrew,then
theBushingwillhavetobeadjustedin
conjunctionwiththeAdjustingScrewsothat
theyarecalibratedwiththegauge.
IMPORTANT
Do not unscrew the Bushing too far out of the
Spring Chamber. If this happens, the spring
force will eject the assembly out of the valve with
great velocity possibly injuring the operator or a
bystander. Please see Figure 1 for distance limit.
6. Ventoutletpressuretoatmosphereacouple
timesusingtheShut-offValvetoensure
thattheOutletPressureGaugecomesback
tothedesiredoutletpressure.Oncedesired
setpressureandcalibrationisachieved,
removeallpressurefromthetestfixture
anddisassembletheValvefromthefixture.
TightenLockNut.
7. ThePBE-3Valveisnowreadytobeplumbed
backintothesystem.
Emerson.com/FinalControl ©2018Emerson.Allrightsreserved. VCIOM-10777-EN 18/11