Metrologic MS 1690 Focus Series is an area-imaging barcode scanner capable of capturing 1D and 2D barcodes omnidirectionally, even if the code is damaged or poorly printed. It can decode a wide variety of barcodes, including Data Matrix, QR Code, MaxiCode, Aztec, Postal Codes, and more. With multiple configurable modes and features such as presentation mode, continuous scan mode, linear illumination aiming, and software handshaking, the MS 1690 Focus Series is suitable for various applications in retail, healthcare, transportation, and manufacturing.

Metrologic MS 1690 Focus Series is an area-imaging barcode scanner capable of capturing 1D and 2D barcodes omnidirectionally, even if the code is damaged or poorly printed. It can decode a wide variety of barcodes, including Data Matrix, QR Code, MaxiCode, Aztec, Postal Codes, and more. With multiple configurable modes and features such as presentation mode, continuous scan mode, linear illumination aiming, and software handshaking, the MS 1690 Focus Series is suitable for various applications in retail, healthcare, transportation, and manufacturing.

METROLOGIC INSTRUMENTS, INC.
MS1690 Focus
Area Imaging Bar Code Scanner
Supplemental Configuration Guide
Copyright
© 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this
work may be reproduced, transmitted, or stored in any form or by any means
without prior written consent, except by reviewer, who may quote brief
passages in a review, or provided for in the Copyright Act of 1976.
Products and brand names mentioned in this document are trademarks of
their respective companies.
ii
TABLE OF CONTENTS
Scanner Operation
Presentation and Trigger Modes........................................................................1
Presentation Mode .........................................................................................1
Multi-Try Trigger Mode ...................................................................................1
Continuous Trigger Mode ...............................................................................1
Single Trigger Mode .......................................................................................2
Omnidirectional and/or Linear Scanner Modes..................................................3
Linear Illumination Aiming ..................................................................................5
Data Output ........................................................................................................5
Same Symbol Timeouts .....................................................................................6
Code Types and Decode Rules
Data Matrix .........................................................................................................7
QR Code ............................................................................................................ 8
MaxiCode ...........................................................................................................8
Aztec ..................................................................................................................9
Postal .................................................................................................................9
RS232
Software Handshaking .....................................................................................13
Interfaces
Additional Interfaces.........................................................................................14
Office Locations and Contact Information............................................................17
1
SCANNER OPERATION
Presentation and Trigger Modes
The MS1690 has four configurable modes for scanning: the presentation mode,
the multi-try trigger Mode, the continuous trigger mode and the single-trigger
mode. These modes can be configured separately for in-stand and out-of-stand
scanner operation.
Presentation Mode
Out-of-Stand
* Presentation Mode
In-Stand
³418304
³420204
* Multi-Try Trigger Mode
Out-of-Stand
Multi-Try Trigger Mode
In-Stand
³418324
³420224
Continuous Trigger Mode
Out-of-Stand
Continuous Trigger Mode
In-Stand
³418354
³420254
* Factory Default Configuration
2
SCANNER OPERATION
Presentation and Trigger Modes
Single Trigger Mode
Out-of-Stand
Single Trigger Mode
In-Stand
³418344
³420244
Set In-Stand Mode to Match
Out-of Stand Mode
³4202154
* Factory Default Configuration
3
SCANNER OPERATION
Omnidirectional and/or Linear Scanner Modes
The MS1690 can be configured to operate as an omnidirectional scanner, or a
linear scanner, or a combination of both. The scanner can be configured to
these modes separately for trigger and presentation operations.
When configured to operate as an omnidirectional scanner, all 1D and 2D
barcodes are scanned omnidirectionally (except Code 128 scanner configuration
labels, which have to be linearly aligned for successful scanning).
When configured to operate as a linear scanner, the 1D barcodes have to be
linearly aligned for successful scanning while the 2D barcodes cannot be
scanned.
When configured to operate as both the linear and omnidirectional scanner, the
1D barcodes have to be linearly aligned for successful scanning while the 2D
barcodes are scanned omnidirectionally.
By default, the scanner is configured to omnidirectional scanning for trigger and
presentation operations.
Enable Linear Only
in Trigger Operations
Disable Linear Only
in Trigger Operations
³120213
³120203
Enable 1D Linear Only
in Trigger Operations
Disable 1D Linear Only
in Trigger Operations
³120212
³120202
4
SCANNER OPERATION
Omnidirectional and/or Linear Scanner Modes
Enable Linear Only
in Presentation Operations
Disable Linear Only
in Presentation Operations
³120211
³120201
Enable 1D Linear Only
in Presentation Operations
Disable 1D Linear Only
in Presentation Operations
³120210
³120200
5
SCANNER OPERATION
Linear Illumination Aiming
The MS1690 can be configured to use the linear illumination as an aiming
means, separately for trigger and presentation operations.
* Enable Aiming in
Trigger Operations
Disable Aiming in
Trigger Operations
³124000
³124010
Enable Aiming in
Presentation Operations
* Disable Aiming in
Presentation Operations
³124011
³124001
Data Output
The MS1690 can be configured to have the data output disabled.
* Enable Data Output Disable Data Output
³121205
³121215
* Factory Default Configuration
6
SCANNER OPERATION
Same Symbol Timeouts
Retain Same Symbol
Timeout on Trigger
* Reset Same Symbol
Timeout on Trigger
³120013
The same-symbol
timeout is not
restarted when the
trigger is pulled.
³120003
The same-symbol
timeout is restarted
when the trigger is
pulled.
* Factory Default Configuration
7
CODE TYPES AND DECODE RULES
Data Matrix
Enable Normal
Color Data Matrix Decoding
Enable Inverse
Color Data Matrix Decoding
³200522
³200512
Enable Normal and Inverse
Color Data Matrix Decoding
* Disable
Data Matrix Decoder
³200532
³200502
Enable Rectangular
Data Matrix Symbol
Decoding
* Disable Rectangular
Data Matrix Symbol
Decoding
³100511
³100501
* Factory Default Configuration
8
CODE TYPES AND DECODE RULES
QR Code
Enable Normal
Video QR Code
Enable Inverse
Video QR Code
³200612
³200622
Enable Normal and Inverse
QR Code
* Disable QR Code
³200632
³200602
MaxiCode
Enable MaxiCode * Disable MaxiCode
³100614
³100604
* Factory Default Configuration
9
CODE TYPES AND DECODE RULES
Aztec
Enable Normal
Video Aztec Decoding
* Disable Normal
Video Aztec Decoding
³100610
³100600
Enable Inverse
Video Aztec Decoding
* Disable Inverse
Video Aztec Decoding
³100611
³100601
Postal
Enable
Australia Post
* Disable
Australia Post
³126217
³126207
* Factory Default Configuration
10
CODE TYPES AND DECODE RULES
Postal
Enable Japan Post * Disable Japan Post
³126216
³126206
Enable KIX Code * Disable KIX Code
³126215
³126205
Enable
PLANET Code
* Disable
PLANET Code
³126214
³126204
* Factory Default Configuration
11
CODE TYPES AND DECODE RULES
Postal
Enable
POSTNET Code
* Disable
POSTNET Post
³126213
³126203
Enable B & B’
Fielded POSTNET
* Disable B & B’
Fielded POSTNET
³126212
³126202
Enable
UPU Decoding
* Disable
UPU Decoding
³126211
³126201
* Factory Default Configuration
12
CODE TYPES AND DECODE RULES
Postal
Enable
Royal Mail 4 Code
* Disable
Royal Mail 4 Code
³126210
³126200
* Factory Default Configuration
13
RS232
Software Handshaking
Enable
]V Handshaking
Disable
]V Handshaking
³125210
An “]V” response from
the host indicates
reception of scanner data.
³125200
14
INTERFACES
Additional Interfaces
Enable Beeper
ON/OFF Commands
* Disable Beeper
ON/OFF Commands
³125211
Enables beeper on/off
commands with internal
USB and IBM interfaces.
³125201
3
rd
Generation
IBM 46xx Defaults
³999952
For this feature to
function properly, scan
IBM Reserved Code #2
after scanning the 3
rd
Generation IBM 46xx
Default bar code.
IBM Reserved Code #2
³317210
Scan IBM Reserve bar
code above after
scanning the 3
rd
Generation IBM 46xx
Default bar code.
15
INTERFACES
Additional Interfaces
IBM 46xx-SIOC RS485 Interface
Send 30H for Last Block
Label Identifier 4680
* Send 00 for Last Block
Label Identifier 4680
³117215
For PDF
codes only.
³117205
For PDF
codes only.
IBM-OEM USB Interface
Send 30H for Last Block
Label Identifier USB
* Send 00 for Last Block
Label Identifier USB
³116300
For PDF
codes only.
³116310
For PDF
codes only.
16
INTERFACES
Additional Interfaces
Full Speed USB
Keyboard Interface
³999940
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Metrologic MS 1690 Focus Series Supplemental Configuration Manual

Type
Supplemental Configuration Manual

Metrologic MS 1690 Focus Series is an area-imaging barcode scanner capable of capturing 1D and 2D barcodes omnidirectionally, even if the code is damaged or poorly printed. It can decode a wide variety of barcodes, including Data Matrix, QR Code, MaxiCode, Aztec, Postal Codes, and more. With multiple configurable modes and features such as presentation mode, continuous scan mode, linear illumination aiming, and software handshaking, the MS 1690 Focus Series is suitable for various applications in retail, healthcare, transportation, and manufacturing.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI