ONE HOLE DECK MOUNTED LAVATORY FAUCET
INSTALLATION GUIDELINES
TECHNICAL DETAILS:
DETAIL SPECIFICATION
DRAIN DEPTH 3/8” [10mm] MINIMUM - 2” [51mm] MAXIMUM
DRAIN HOLE DIAMETER ø1-1/2” [38mm]
DRAIN STYLE PUSH-TOUCH
INLET CONNECTION 3/8” COMPRESSION CONNECTOR HOSES †
SPOUT REACH 5-1/4” [133mm]
WATER PRESSURE 20psi [1.5 bar] MINIMUM - 85psi [6.0 bar] MAXIMUM
WATER PRESSURE RECOMMENDED 45psi [3.0 bar]
For INTERNATIONAL USE ONLY, two UNUK08 9/16”-24 UNEF MALE x 3/8” FEMALE BSPP
ADAPTERS and RUBBER WASHERS are provided.
IMPORTANT:
¾To ensure this product is installed properly, you must read and
follow these guidelines.
¾The owner/user of this product must keep this information for
future reference.
¾This product must be installed by a professional licensed
contractor.
¾Be sure your installation conforms to all federal, state, and local
codes. In the State of Massachusetts, all installations must comply
with the rules and regulations set forth within 248 CMR.
¾Inspect this product to ensure you have all the parts required for
proper installation.
¾This product is sold partially assembled but shown fully
disassembled for illustrative and service purposes only.
¾Flushing the SUPPLY VALVES (sold separately) prior to installing
the LAVATORY FAUCET is recommended. Flushing can prevent
damage to the CARTRIDGE and other internal components.
¾Use only a strap wrench or protected/smooth-jaw wrench on any
finished surface.
¾The use of certain plumber’s putty may stain stone or tile surfaces.
¾If further assistance is required, please contact Product Support
at 1-800-927-2120 Monday through Friday, 8am – 6pm EST.
¾Refer to the separate Service Parts Documents for available
replacement parts.
STYLES
HLS401 [SHOWN] HLS402 CLS411 [SHOWN]
CLS414 CLS415
HENRY OR HENRY CHRONOS ONE HOLE LAVATORY FAUCET
WITH HANDLE
90°
7F==9@E
45°
7F==
4@=5
4=:4<
[OFF]
HANDLE
'(°
>:I65
4=:4<
HANDLE OPERATION:
¾This product is equipped with a PROGRESSIVE MIXING CARTRIDGE which incorporates tactile
feedback.
The user will feel slight haptic bumps as they operate the HANDLE.
These bumps indicate when the CARTRIDGE is at full cold and warm water temperatures.
¾The HANDLE rotates a 1/4 turn counterclockwise through cold, warm, and hot water
temperatures as shown above.
MOUNTINGMOUNTING
SURFACESURFACE
#-&/)"
[''mm]
MAX DECK
THICKNESS
Ø 1-3/8"
[35mm]
FITTINGS
HOLE
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 2 OF 5 | UPDATED ON 11.23.2022
ONE HOLE DECK MOUNTED LAVATORY FAUCET
INSTALLATION GUIDELINES
1. Remove the BARREL NUT, METAL WASHER, and
RUBBER WASHER from the THREADED ROD.
NOTE: Do NOT remove the THREADED ROD or
FOAM WASHER beneath the ESCUTCHEON.
2. Thread and securely tighten the SUPPLY HOSES
onto the SUPPLY TUBES on the SPOUT.
NOTE: The HOSES are M10 x 3/8” COMPRESSION
CONNECTOR HOSES and the TUBES are marked
BLUE for cold and RED for hot.
3. Insert the SUPPLY HOSES through the hole on the
mounting surface making sure the FOAM WASHER
provided is beneath the ESCUTCHEON.
4. Slide the RUBBER and METAL WASHERS back
onto the THREADED ROD then thread and securely
tighten the BARREL NUT onto the ROD.
NOTE: Ensure the WASHERS fit properly around
the TUBES and HOSES.
5. Unthread and remove the RING ADAPTER from
the SPOUT, then thread the ADAPTER onto the
GLAND COVER until snug.
6. With the HANDLE held horizontally thread the
RING ADAPTER into the SPOUT until snug.
"COLD"
SUPPLY TUBE
"HOT"
SUPPLY TUBE
SUPPLY
HOSE
SUPPLY
HOSE
[BLUE LABEL]
[RED LABEL]
SUPPLY
HOSE
MOUNTING
SURFACE
FOAM WASHER
ESCUTCHEON†
SPOUT
A FOAM WASHER for the
ESCUTCHEON is provided. If
desired, a bead of caulk or clear
silicone may be applied where
the ESCUTCHEON contacts the
mounting surface.
METAL WASHER
RUBBER WASHER
BARREL NUT
THREADED ROD
SUPPLY
HOSE
SPOUT
CARTRIDGE
STEM
RING
ADAPTER
HANDLE
GLAND
COVER
SPOUT
CARTRIDGE
STEM
GLAND COVER
RING
ADAPTER
HANDLE
RUBBER WASHER
METAL WASHER BARREL NUT
[M8 THREAD]
THREADED ROD
FOAM WASHER
[DO NOT REMOVE]
[DO NOT REMOVE] [M8 THREAD]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 3 OF 5 | UPDATED ON 11.23.2022
ONE HOLE DECK MOUNTED LAVATORY FAUCET
INSTALLATION GUIDELINES
7. Remove the AERATOR from the SPOUT using the
AERATOR KEY provided.
8. Unthread and remove the NUT, TAILPIECE, and
GASKET from the LOWER DRAIN BODY.
9. Remove the DRAIN STOPPER from the DRAIN
FLANGE then unthread the SCREW from the
LOWER DRAIN BODY.
NOTE: Do NOT remove or discard the LOWER
DRAIN GASKET.
10. Set the DRAIN FLANGE into the LAVATORY (sold
separately) using putty or a clear silicone.
11. Insert the SCREW provided into the FLANGE then
thread and securely tighten the SCREW into the
LOWER DRAIN BODY making sure the LOWER
DRAIN GASKET makes a full seal on the underside
of the LAVATORY.
12. Re-install the DRAIN STOPPER and TAILPIECE
using the GASKET and NUT provided.
NUT
TAILPIECE
GASKET
LOWER DRAIN
BODY
SPOUT
AERATOR
AERATOR
KEY
LOWER DRAIN
GASKET
LOWER DRAIN
BODY
UPPER DRAIN
GASKET
[CAN BE
DISCARDED]
DRAIN FLANGE
SCREW
DRAIN
STOPPER
LAVATORY
[SOLD SEPARATELY]
DRAIN
FLANGE *
* USE PUTTY OR A
CLEAR ADHESIVE
SILICONE LOWER DRAIN BODY
LOWER DRAIN GASKET
DRAIN
FLANGE
SCREW
NUT
TAILPIECE
GASKET
LOWER DRAIN
BODY
DRAIN
STOPPER
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 4 OF 5 | UPDATED ON 11.23.2022
ONE HOLE DECK MOUNTED LAVATORY FAUCET
INSTALLATION GUIDELINES
18. Re-install the AERATOR using the tool provided.
13. Make final P-TRAP (sold separately) connections. 14. Connect the SUPPLY HOSES to the SUPPLY
VALVES (sold separately).
NOTE: The HOSES are connected to SUPPLY
TUBES that are marked BLUE for cold and RED for
HOT.
FOR INTERNATIONAL INSTALLATIONS ONLY:
15. Using the RUBBER WASHERS provided, thread
and securely tighten the BSPP ADAPTERS onto the
SUPPLY VALVES then thread and securely tighten
the SUPPLY HOSES onto the ADAPTERS.
16. Turn on the water supply and operate the HANDLE
to flush out the supply lines. Inspect all connections
for leaks then close the DRAIN to ensure it
functions properly.
NOTE: The HANDLE will rotate counterclockwise
a 1/4 turn through cold, warm, and hot water
temperatures.
17. Close the HANDLE then open the DRAIN to drain
the water.
SUPPLY VALVE
[SOLD SEPARATELY]
SUPPLY HOSE
RUBBER
WASHER
BSPP
ADAPTER
1. CLOSE HANDLE
2. OPEN
DRAIN
SPOUT
AERATOR
AERATOR
KEY
1. TURN ON WATER
SUPPLY AND
OPERATE HANDLE
2. CLOSE
DRAIN
3. CHECK FOR LEAKS
SUPPLY VALVE
[SOLD SEPARATELY]
SUPPLY HOSE
P-TRAP
[SOLD SEPARATELY]
TAILPIECE
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 5 OF 5 | UPDATED ON 11.23.2022
CARTRIDGE
STEM
SPOUT
GLAND COVER
RING ADAPTER
HANDLE
CARTRIDGE
RETAINING
COLLAR
[22mm HEX]
[TOWARD SPOUT]
[COLD
INLET]
[HOT
INLET]
SERVICING THE CARTRIDGE:
1. Unthread the RING ADAPTER along with the
GLAND COVER from the SPOUT then pull the
HANDLE off.
2. Unthread and remove the RETAINING COLLAR
then pull the CARTRIDGE out.
NOTE: Replacing the RETAINING COLLAR requires
a torque of 11 ft-lb [15N•m]. Exceeding this torque
will damage the CARTRIDGE.
ONE HOLE DECK MOUNTED LAVATORY FAUCET
SERVICE GUIDELINES
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

WaterWorks CLS411 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI