Takagi 510 Outdoor (T-D2-OS) Installation Manual And Owner's Manual

Type
Installation Manual And Owner's Manual

This manual is also suitable for

Do not store or use gasoline or other
flammablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
WHATTODOIFYOUSMELLGAS
Donottrytolightanyappliance.
Do not touch any electric switch, do not
useanyphonein
yourbuilding.
Immediately callyourgassupplierfroma
neighbor's phone. Follow the gas
supplier'sinstructions.
Ifyoucannotreachyourgassupplier, call
thefiredepartment.
Installation and service must be performed
byaqualifiedinstaller,serviceagencyorthe
gassupplier.
TAKAGI
FEATURING
ENDLESSHOTWATER
ONDEMANDUSAGE
COMPACT,SPACESAVING
ENERGYCONSERVATION
COMPUTERIZEDSAFETY
NOPILOTLIGHT
EASYLINKSYSTEM(OnlyTD2IN&TD2OS)
GasTanklessWaterHeater
Suitablefor p otablewaterheatingandspaceheating
*
*Pleaserefertolocalcodesforspaceheatingcompliance.
Ifyouhaveanyquestions,please
callorwriteto:
5Whatney
Irvine,CA92618
TollFree:18888825244
OnDemandWaterHeater
InstallationManualandOwner’sGuide
Model
TKJr2INTKJr2OS
TK4INTK4OS
TD2INTD2OS
WARNING
Iftheinformationinthese
instructionsisnotfollowed
exactly,afireorexplosion
mayresultcausing
propertydamage,personalinjuryordeath.
“ANSIZ21.10.3”
and“CSA4.3”
OnlyTD2models
Contents
2Page
CONTENTS

SPECIFICATIONS…………………………………………………………………………………………..………………………...
INTRODUCTION…………………………………………………………………………………………………..………………….
SAFETYGUIDELINES…………….………………………………………………………………………………………..………..
INSTALLATION………………………………………………………………………………………………..…………………..….
General………………………………………………………………………………………………………………………..…..…
Clearances……………………………………………………………………… ……………………………………………………
IncludedAccessories…………….………………………………………………………………………………………..…..
OptionalItems……………………………………………………………………………………………………………………..
HighAltitudeInstallations……………………………………………………………………………………………………
.
VentingInstructions…………………………………………………………………………………………………………….
.
GasSupplyandGasPipeSizing………......................................................................................…
WaterConnections……………..…………………………………………………………………………………………….…
ElectricalConnections……………………………………………………………………..…………………………….......
RemoteControllerConnections.……..……………………………………………………………………………….…
PumpControlMode(OnlyTD2IN&TD2OS)………………………….……………………………….………
EasyLinkSystem(OnlyTD2IN&TD2OS)…….……………………...…………………………………..…....
APPLICATIONS...………………………………………………………………………………………………………………………
INITIALOPERATION..………………………………………………………………………………………………………….……
OPERATINGSAFETY…………………………………………………………………………………………………………………
NORMALOPERATION…………………………………………………………………………………………………………..…
General………..……….………….…………………………………………………………………………………………………
TemperatureSettings.…….……..……………………………………………………………………………………………
Flow…………………………………………………………………………………………………………………………………….
FreezeProtectionSystem…….…………………………………………………………………………………………..…
MaintenanceandService………………………………………………………………………………………………….…
UnitDrainingandFilterCleaning…………………………………………………………………………………………
TROUBLESHOOTING……..……………………………………………………………………………………………………..…
General………..……….………….…………………………………………………………………………………………………
ErrorCodes.…………………….…..………………………………………………………………………………………………
COMPONENTSDIAGRAM……………………………………………………………………………………………………..…
PARTSLIST………………….………………………………………………………………………………………………..…………
OUTPUTTEMPERATURECHART…………………………………………………………………………………………...…
PRODUCTREGISTRATIONANDLIMITEDWARRANTY…………....…………………………………………….…
3
4
5
6
6
8
8
9
11
12
17
20
21
22
23
24
28
30
31
33
33
33
35
35
36
36
37
37
39
42
46
48
50
InstallationManual
Owne
r
’sGuide
Specifications
3Page
SPECIFICATIONS
Model TKJr2IN TKJr2OS TK4IN TK4OS TD2IN TD2OS
NaturalGasInput
(OperatingRange)
Min:19,500Btu/h
Max:140,000Btu/h
Min:11,000Btu/h
Max:190,000Btu/h
Min:11,000Btu/h
Max:199,000Btu/h
PropaneInput
(OperatingRange)
Min:19,500Btu/h
Max:140,000Btu/h
Min:11,000Btu/h
Max:190,000Btu/h
Min:11,000Btu/h
Max:199,000Btu/h
GasConnection ¾”NPT
WaterConnections
¾”NPT
WaterPressure 15‐150psi*
NaturalGas
InletPressure
Min.5.0”WC
Max.10.5”WC
Propane
InletPressure
Min.8.0”WC
Max.14.0”WC
Manifold
Pressure**
Natural 2.0”WC 2.5”WC 2.0”WC 2.5”WC 2.0”WC 2.5”WC
Propane 2.5”WC 3.1”WC 3.7”WC 4.0”WC 3.7”WC 4.5”WC
Weight 28.7lbs. 34.6lbs.
Dimensions
H20.5”xW13.8”xD6.7”
H20.5”xW13.8”xD8.5”
Ignition ElectricIgnition
Electric
Supply 120VAC/60Hz
Consumption
Operation
73.1W/0.61A 87.6W/0.73A 89.8W/0.75A
Standby 6.2W/0.05A 6.2W/0.05A 6.2W/0.05A
Freeze
Protection
111W/0.93A 111W/0.93A 111W/0.93A
*40psioraboveisrecommendedformaximumflow.
**TheManifoldPressureisthefactorysettingandgenerallyshouldnotneedadjustment.
NOTE:
Checktheratingplatetoensurethisproductmatchesyourspecifications.
InaccordancewithANSIZ21.10.3,COemissiondoesnotexceed400PPMfor
normalinput.
Themanufacturerreservestherighttodiscontinue,orchangeatanytime,
specificationsordesignswithoutnoticeandwithoutincurringobligations
.
I
I
I
n
n
n
s
s
s
t
t
t
a
a
a
l
l
l
l
l
l
a
a
a
t
t
t
i
i
o
o
o
n
n
n
M
M
M
a
a
a
n
n
n
u
u
u
a
a
a
l
l
l
Introduction
4Page
INTRODUCTION
*Thisdiagram
illustratestankless
waterheaterdesign
conceptsonlyand
doesnotaccurately
representtothewater
heater’sphysical
description.
This manual provides information necessary for the installation, operation, and
maintenanceofthewaterheater.
Themodeldescriptionislistedontheratingplatewhichisattachedtothefrontpanel
ofthewaterheater.
Pleasereadallinstallationinstructionscompletelybeforeinstallingthisproduct.
If you have any problems or questions regarding this equipment, consult with the
manufactureroritslocalrepresentative.
Thisequipmentisanondemand,tanklesswaterheaterdesignedtoefficientlysupply
endlesshotwaterforyourneeds.
Theprinciplebehindtanklesswaterheatersissimple:
1. Ahotwatertapisturnedon.
2. Waterenterstheheater.
3. Thewaterflowsensordetectsthewaterflow.
4. Thecomputerinitia testhefanmotorandsendsasignaltotheignitertocreateanignition
spark.
5. Thegasignitesandflames
appearwithintheburnerchamber.
6. Watercirculatesthroughtheheatexchangerandthengetshot.
7. Usingthermistorstomeasuretemperaturesthroughoutthewaterheater,thecomputer
modulatesthegasandwatervalvestoensureproperoutputwatertemperature.
8. Whentheta
p
isturnedoff
,
theunitshutsdown.
The TKJr2IN, TK4IN, & TD2IN are to be only installed indoor (directvent
convertible).TheTKJr2OS,TK4OS,&TD2OSaretobeonlyinstalledoutdoor.
SafetyGuidelines
5Page
Watertemperaturesover125°F (52
°
C) cancausesevereburnsinstantlyordeath
fromscalding. The water temperatureisset at 122°F (50°C) from the factory to
minimizeanyscaldingrisk.Beforebathingorshoweringalwayscheckthewater
temperature.
Do notstoreorusegasolineorotherfl ammables,vapors,orliquidsinthevicinity
ofthisappliance.
Do not reverse the water and/or gas connections as this will damage the gas
valves and can cause severe injury or death. Follow the diagram on p. 20 when
installingyourwaterheater.
Do notusethisapplianceifanyparthasbeenincontactwithorbeenimmersed
in water. Immediately call a licensed plumber, a licensed gas fitter, or a
professionalservicetechniciantoinspectand/orservicetheunitifnecessary.
Do not disco nnect the electrical supply if the ambient temperature will drop
belowfreezing.TheFreezePreventionSystemonlyworksiftheunithaselectrical
power.Thew a rrantywillnotbecoverediftheheatexchangerisdamageddueto
freezing.RefertothesectionontheFreezePreventionSystemon
p.35formore
information.
SAFETYGUIDELINES
SAFETYDEFINITIONS
Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,willresultin
deathorseriousinjury.
Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,couldresult
indeathorseriousinjury.
Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,couldresult
inminorormoderateinjury.
GENERAL
1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the
NationalFuelGasCode:ANSIZ223.1/NFPA54intheUSAorCAN/CSAB149.1NaturalGas,Propane
InstallationCodeinCanada.
2. Properlygroundtheunit inaccordance withall localcodes or
intheabsenceoflocalcodes,with
the National Electrical Codes:ANSI/NFPA70 in the USA or CSA standard C22.1CanadaElectrical
CodePart1inCanada.
3. Carefullyplanwhereyouintendtoinstallthewaterheater.Pleaseensure:
Yourwaterheaterwillhaveenoughcombustibleairand
properventilation.
Locateyourheaterwherewaterleakagewillnotdamagesurroundingareas(pleaserefer
top.7).
4. ChecktheratingplateforthecorrectGASTYPE,GASPRESSURE,WATERPRESSUREandELECTRIC
RATING.
*If this unit does not match your requirements, do not install and consult with the
manufacturer.
5. Ifany problem should occur, turn off all hot water taps and turn off the gas. Then call a trained
technicianortheGasCompanyorthemanufacturer.
WARNING
CAUTION
DANGER
WARNING
Installation
6Page
INSTALLATION
GENERAL
1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the
National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the USA or CAN/CSA B149.1 Natural Gas,
PropaneInstallationCodeinCanada.
2. Allgaswaterheatersrequirecarefulandcorrectinstallationto
ensuresafeandefficient
operation.Thismanualmustbefollowedexactly.Readthe“SafetyGuidelines”section.
3. Themanifoldgaspressureispresetatthefactory.Itiscomputercontrolledandshouldnot
needadjustment.
4. Maintainproperspaceforservicing.Installtheunitsothatitcanbeconnected
orremoved
easily.RefertotheClearancesSectiononp.8forproperclearances.
5. Thewaterheatermustbeinstalledinalocationwheretheproperamountofcombustibleair
willbeavailabletoitatalltimeswithoutobstructions.
6. Theelectricalconnectionrequiresameansofdisconnection, toterminatepowertothewater
heaterforservicingandsafetypurposes.
7. Donotinstalltheunitwheretheexhaustventispointingintoanyopeninginabuildingorwhere
thenoisemaydisturbyourneighbors.Makesuretheventterminationmeetstherequired
distancebylocalcodefromanydoorwayoropeningtopreventexhaustfromenteringabuilding
(refer
top.15).
8. Particlesfromflour,aerosols,andothercontaminantsmayclogtheairventorreducethe
functionsoftherotatingfanandcauseimproperburningofthegas.Regularlyensurethatthe
areaaroundtheunitisdust‐ordebrisfree;regularmaintenanceisrecommendedforthese
typesofenvironment.
9. Ifyouwillbeinstallingthewaterheaterinacontaminatedareawithahighlevelofdust,sand,
flour,aerosolsorothercontaminants/chemicals,theycanbecomeairborneandenterandbuild
upwithinthefanandburnercausingdamagetothewaterheater.
10. FortheTKJr2IN,TK4IN,andTD2INmodels:
Theseunitsmaybeconv ertedtoadirectvent(sealedcombustion)appliancebyinstalling a
directventconversionkit(PartNo. TKTV10)whichwillbringinallrequiredcombustibleair
from outside the building.When
installing the TKTV10 conversion kit, please follow all
instructionsincludedwiththekit.
Ifthewaterheaterisusedasadirectventappliance, theunitrequiresa3”combustibleair
supply pipe. Theintakepipe mustbesealed airtight. Air supply pipe can bemadeof ABS,
PVC, galvanized steel, corrugated aluminum, corrugated stainless steel or Category III
stainlesssteel.
Terminatingtheventingthroughasidewallisrecommendedforthedirectventsystem.
Runningtheexhaustventandtheintakepipeparallelisrecommended.
Terminating the exhaust and intake on the same wall / surface
is recommended.
Terminating in the same pressure zone allows for pressure balancing, which prevents
nuisanceshutdowns.
11. ForTKJr2OS,TK4OS,&TD2OS:
Tobeinstalledoutdoorsandonlyinareaswithmild,temperateclimates.
Installation
7Page
Installation and service must be performed by a qualified installer (for
example, a licensed plumber or gas fitter), otherwise the warranty will be
void.
Theinstaller(licensedprofessional)is responsibleforthecorrec tinstallation
of the water heater and for compliance with all national, state/provincial,
andlocalcodes.
Themanufacturerdoesnotrecommendinstallingthewaterheaterinapitor
locationwheregasandwatercanaccumulate.
Do nothavetheventterminalpointingtowardanyoperatingwindow,door,or
openingintoabuilding.
Do not install next to any source of airborne debris, such as a clothes dryer,
that can cause debris to be trapped inside the combustion chamber, unless
thesystemisdirectvented.
The manufacturer does not recommend installing the water heater in an
atticduetosafetyissues.Ifyouinstallthewaterheaterinanattic:
Makesuretheunitwillhaveenoughcombustionairandproperventilation.
Keep the area around the water heater clean. When dust collects on the
flamesensor,thewaterheaterwillshutdownonanerrorcode.
If the above conditions cannot be met, use the direct vent conversion kit
TKTV10.
Placetheunitforeasyaccessforserviceandmaintenance.
A drain pan, or other means of protection against water damage, is
re
q
uiredtobeinstalledunderthewaterheaterincaseofleaks.
Thewarrantywillnotcoverdamagecausedbywaterquality.
Onlypotablewaterorpotablewater/glycolmixturescanbeusedwiththis
water heater.Do not introduce pool or spa water, or any chemically
treatedwaterintothewaterheater.
Water hardness levels must not exceed 7 grains per gallon (120 ppm) for
single family domestic applications or more than 4 grains per gallon (70
ppm) for all other types of applications.Water hardness leads to scale
formation and may affect/damage the water heater.Hard water scaling
mustbeavoidedor
controlledbyproperwatertreatment.
WaterpHlevelsmustbebetween6.5and8.5
Wellwatermustbetreated.
Do notinstalltheunitwherewater,debris,orflammablevaporsmaygetinto
theflueterminal.
The manufacturer recommends using the direct vent kit when the water
heater is inst alled ina beauty salon. Somechemicalsusedinabeauty salon
mayaffecttheflamesensor.Waterheatermaynotworkproperly.
Although the water heater is designed to operate with minimal sound, the
manufacturerdoesnotrecommendinstallingtheunitonawalladjacenttoa
bedroom,oraroomthatisintendedforquietstudyormeditation,etc.
Locateyourheaterclosetoadrainwherewaterleaka gewillnotdodamageto
surrounding areas.As with any water heating appliance, the potential for
leakageatsome timein thelifeoftheproductdoesexist.Themanufacturer
willnot beresponsibleforanywaterdamagethatmay occur.
Ifyouinstall a
drain pan under the unit, ensure that it will not restrict the combustion air
flow.
CAUTION
WARNING
Installation
8Page
CLEARANCES
Model Top Bottom Front Back Sides
TKJr2IN* 12” 12” 24” 1” 2
TKJr2OS 36” 12” 24” 1” 2
Model Top Bottom Front Back Sides
TK4IN* 12” 12” 24” 1” 2
TK4OS 36” 12” 24” 1” 2
Model Top Bottom Front Back Sides
TD2IN* 12” 12” 24” 1” 2
TD2OS 36” 12” 24” 1” 2
*Standardindoorinstallations&directventindoorinstallationshavethesameclearances.
INCLUDEDACCESSORIES
Checkthattheseitemsbelowareincludedwiththewaterheater.
1. Installation Manual &
Owner’sGuide
2.
ProductRegistrationCard
3.CommunicationCable
(OnlyTD2IN&TD2OSmodels)
Qty:1
Qty:1
Qty:1
Bottom
Side
Top
Side
Front
Back
Maintain all clearances around
thewaterheater.
Installation
9Page
OPTIONALITEMS
Model TKJr2IN TKJr2OS TK4IN TK4OS TD2IN TD2OS
TKRE02
TMRE30
TKBF01
TKTV10
TKPC01
TKPCJr2
TKRB02
TKKPWL4
TKKPWH4
TKKPCT43
1.TemperatureRemoteController:TKRE02
The Temperature Remote
Controllerhastwofunctions.It
allowstheoutputtemperature
from the water heater to be
adjusted within the range of
99 °F to 167 °F, and it also
worksasa diagnostic tool that will give a concise
error code whenever
there is a problem with the
unit. The temperature options are 99°F, 100°F,
102°F, 104°F, 106°F, 108°F, 109°F, 111°F, 113°F,
115°F, 117°F, 122°F, 131°F, 140°F, 158°F, and
167°F. See the trouble shooting section for
informationonpossibleerrorcodes.
2.TemperatureRemoteController:TMRE30
The Temperature Remote
Controller has
two functions. It
allows the output temperature
from the water heater to be
adjustedwithin therangeof99
°Fto185°F,anditalsoworksas
adiagnostictoolthatwillgiveaconciseerrorcode
whenever there is a problem with the unit. The
temperature options are
99°F, 100°F, 102°F,
104°F, 106°F, 108°F, 110°F, 111°F, 113°F, 115°F,
117°F, 122°F, 131°F, 140°F, 149°F, 158°F, 167°F,
176°Fand185°F.Seethetroubleshootingsection
forinformationonpossibleerrorcodes.
3.BackflowPreventer:TKBF01
The Backflow preventer prevents
the backflow of air through the
exhaust vent. This helps prevent
harmful exhaustgases from
entering the home, as well as
helpingtopreventtheunitfromfreezing inareas
where cold air can be blown or drawn into the
exhaust system.
Install this vent damper in
accordance with the installation instructions and
anyapplicablecodes.
4.DirectVentConversionKit:TKTV10
Thiskitcanbeusedto
convertthewater
heaterfroma
standardventsystem
toadirectvent(or
sealedcombustion)
system.Installthis
conversionkitinaccordancewiththeinstallation
instructionsandanyapplicablecodes.
Installation
10Page
5.PipeCovers:TKPC01andTKPCJr2
The pipe cover protects the
plumbingpipestothewaterheater
fromunexpected adjustments.
This pipe cover is fixed to the
bottom of the water heater, which
hides the plumbing and improves
the visual aspects of the whole
installationforthewater
heater.
6. Recessbox:TKRB02
TheRecessboxwillallowfor
“clean”installations.Thewater
heaterfitsinsidetherecessbox,
whichhidesandprotectsthe
wholewaterheaterandplumbing.
TheRecessboxwillfitinbetween
mostwallstuds.
7.TVentWallThimblewithTermination:TKKPWL4andTKKPWH4
Theseterminationsareusedwhenventingoutthroughthewall
andarecompatiblewiththeTVentpipesystem.
Theseterminationsarespecialstainlessstee lventsforgas
appliancesandareULlistedasCategoryII,II IandIV.Thereare
twotypesofterminations:theLouverterminationandtheHood
termination.Fordifferentwallthicknesses,therearetworanges
oflength savailable(refertotheTVentbrochurefordetails).
Installtheseventterminat ionsinaccordancewiththeir
installationinstructi on sandanyapplicable localcodes.
8.DirectVentConcentricTermination:TKKPCT43
Usedwhenterminatingdirectvent(sealedcombustion)systems,
withdirectventmodelsthatrequirea3”intakeand a4”exhaust.
Thisconcentricterminationprovidestheconvenienceofonly
havingtomakeonepenetrationthroughasidewallinsteadoftwo
separatepenetrationsfortheintakeandexhaustpiping.The
terminationincludes
abirdscreen,restrictingsmallanimals,
pests,andforeignobjectsfromenteringintotheventsystem.
Thissidewallterminationisavailableinthreedifferentsizes,to
coverallrangesofwallthicknesses.
DirectventConcentricTermination
Part# Coveringwallthickness
TKKPCT431 3.9”7.1”
TKKPCT432 6.9”10.1”
TKKPCT433 9.8”13.0”
Louver
Termination
TKKPWL4
Hood
Termination
TKKPWH4
Installation
11Page
DONOTadjustanydipswitchesontherightbankfortheTD2IN/OS
models.
Thedarksquaresindicatethedirectionthedipswitchesshouldbesetto.
Dipswitches
HIGHALTITUDEINSTALLATIONS
Checktheelevationwhereyourwaterheaterisinstalled.Setdipswitchesshowninthetablebelow
dependingonthealtitude.
Altitude
0to2,000ft
(DEFAULT)
2,000to4,000ft
4,000to6,000ft Over6,000ft
SwitchNo.3 OFF
ON
OFF
Consult
our Technical
Services
Department
at1888‐
8825244
SwitchNo.4 OFF
OFF
ON
Altitude
0to2,000ft
(DEFAULT)
2,000to4,000ft
4,000to6,000ft Over6,000ft
SwitchNo.4 OFF
ON
OFF
Consult
our Technical
Services
Department
at1888‐
8825244
SwitchNo.5 OFF
OFF
ON
TKJr2IN/OS&TK4IN/OS
TD2IN/OS(Leftbankofdipswitches)
TKJr2IN
/
OS&TK4IN
/
OSCom
p
uterboard
WARNING
TD2IN
/
OSCom
p
uterboard
Leftbankofdipswitches
O
F
F
O
N
1
2
3
4
5
6
7
8
O
F
F
O
N
1
2
3
4
5
6
7
8
O
F
F
O
N
1
2
3
4
5
6
7
8
O
F
F
O
N
1
2
3
4
5
6
O
F
F
O
N
1
2
3
4
5
6
O
F
F
O
N
1
2
3
4
5
6
Installation
12Page
Improperventingofthisappliancecanresultinexcessivelevelsofcarbon
monoxidewhichcanresultinseverepersonalinjuryordeath.
Improperinstallationcancausenauseaorasphyxiation,severeinjuryordeathfrom
carbonmonoxideandfluegasespoisoning.Improperinstallationwillvoidproduct
warranty.
Wheninstallingtheventsystem,allapplicablenationalandlocalcodesmustbe
followed.Ifyouinstallthimbles,firestopsorotherprotectivedevicesandthey
penetrateanycombustibleornoncombustibleconstruction,besuretofollowall
applicablenationalandlocalcodes.
VENTINGINSTRUCTIONS
General
Thewaterheatermustbe vented inaccordancewith thesection“Ventingof Equipment" ofthelatest
editionoftheNationalFuelGasCode:ANSIZ223.1/NFPA54intheUnitedStatesand/orSection7ofthe
CAN/CSA B149.1 Natural Gas and Propane Installation Code in Canada, as well
as applicable local
buildingcodes.
The manufacturer recommends the “TVent” line manufactured by TAKAGI (Refer to “TVent”
brochure for details). However, the following are also UL listed manufacturers: ProTech Systems Inc.
(FasNSeal),FlexLInc.,ZFlexInc.(ZVentIII),MetalFabInc.,andHeatFabInc.(SafTVent).
Generalrulesforventingwaterheatersare:
Placethewaterheaterascloseaspossibletotheventterminator.
Thevent coll arofthewaterheatermustbefasteneddirectlytoanunobstructedventpipe.
Donotweldtheventpipetothewaterheater’sventcollar.
Donotcuttheventcollaroftheunit.
Theventmustbeeasily removablefromthetopofthewaterheaterfornormalserviceand
inspectionoftheunit.
Thewaterheaterventmustnotbeconnectedtoanyothergasapplianceorventstack.
Avoid
usinganoversizedventpipeorusingextremelylongrunsofthepipe.
Forrooftopventing, araincaporotherformofterminationthatpreventsrainwater from
enteringintothewaterheatermustbeinstalled.
Donotcommonventorconnectanyventfromotherappliances
tothewaterheatervent.
Generalrulesforventterminations:
Avoidlocatingthewaterheaterventterminatornearanyairintakedevices.Thesefanscan
pick uptheexhaust flue productsfromthe water heater andreturnthemto thebuilding.
Thiscancreateahealthhazard.
Locate the vent terminator so that
it cannot be blocked by any de bris, at any time. Most
codesrequir e thattheterminatorbe atleast12inchesabovegrade,butthe installermay
determineifitshouldbehigherdependingonthejobsitecondi tionandapplicablecodes.
A propersidewall terminatorisrecommendedwhen
thewa ter heaterisventedthrough a
sidewall.
Regarding the clearances fromtheexhaustterm inatortotheairinlet or opening, refer to
thenextfewpages.
CAUTION
DANGER
Installation
13Page
Exhaustventing‐
(FortheTKJr2IN,TK4IN,&TD2INmodels)
ThisisaCategoryIIIapplianceandmustbeventedaccordingly.Theventsystemmustbesealedairtight.
Allseamsandjointswithoutgasketsmustbesealedwithhighheatresistantsilicone sealantorULlisted
aluminumadhesivetapehavingaminimumtemperatureratingof350°F.Forbestresults,a
ventsystem
shouldbeasshortandstraightaspossible.
ThiswaterheaterisaCategoryIIIapplianceandmustbeventedaccordinglywithany4”vent
approvedforusewithCategoryIIIorSpecialBHtypegasvent.
Followtheventpipemanufacturer’sinstructionswheninstallingthe
ventpipe.
Donotcommonventthisappliancewithanyotherventedappliance(Donotterminatevent
into a chimney.If the vent must go through the chimney, the vent must run all the way
throughthechimneywithCategoryIIIapprovedorSpecialBHventpipe).
When
the horizontal vent run exceeds 5 ft., support the vent run at 3 ft. intervals with
overheadhangars.
Themaximumlengthofexhaustventpiping mustnotexceed50ft.(deducting5 ft.foreach
elbowusedintheventingsystem).Donotusemorethan5elbows.
Diameter Max.No.ofElbow Max.Vertical&Horizontal(Total)VentLength
4” 5 50ft.
*Foreachelbowadded,deduct5ft.frommax.Ventlength.
No.ofElbows Max.VerticalorHorizontalLength
0 50ft.
1 45ft.
2 40ft.
5 25ft.
VentingIllustrations‐
(FortheTKJr2IN,TK4IN,&TD2INmodels)
HorizontalInstallationDiagram
VerticalInstallationDiagram
SidewallVent
Terminator
Wall
BackflowPreventer*
VerticalCondensationDrain**
Fordetailsoftheoptionalitems,refertothe InstallationmanualforeachOptionalitem.
Roof
VerticalCondensation
Drain**
RoofFlashing
RainCap
BackflowPreventer*
Installation
14Page
*BackflowPreventer(Recommendedforfreezingweatherconditions:36
°
F andbelow)
**VerticalCondensationDrainmustbeinstalledaccordancewithlocalcodes.
HorizontalInstallationDiagram
WithDirectVentConcentric
Termination
HorizontalInstallationDiagram
(Withdirectventing)
VerticalInstallationDiagram
(Withdirectventing)
Thewaterheater
Intakeportof
DirectVent
ConversionKit
InstallationDiagramofDirectVent
ConversionKitwithwaterheater
Wall
Directvent
Concentric
Termination
PlateofDirectVentConversionKit
Seethepicturebelowfordetailedconnection
instructionstotheDirectVentConversionKit.
VerticalCondensationDrain**
Backflow
Preventer*
Wall
Sidewall
Vent
Terminator
RoofFlashing
Vertical
Condensation
Drain**
Backflow
Preventer*
RainCap
Roof
Firestop
Installation
15Page
Ventterminationclearances‐

Canada U.S.A
Directventand
otherthanDirect
Vent
Directvent OtherthanDirectVent
A
Clearanceabovegrade,veranda,porch,deck,
orbalcony.
1foot 1foot 1foot
B
Clearancetowindowordoorthatmaybe
opened.
3feet 1foot
4feetfrombeloworside
opening.1footfrom
aboveopening.
C
Clearancetopermanentlyclosedwindow * * *
D
Verticalclearancetoventilatedsoffitlocated
abovetheventterminatorwithinahorizontal
distanceof2feet(61cm)fromthecenterline
oftheterminator.
* * *
E
Clearancetounventilatedsoffit * * *
F
Clearancetooutsidecorner * * *
G
Clearancetoinsidecorner * * *
H
Clearancetoeachsideof centerlineextended
abovemeter/regulatorassembly
3feet * *
I
Clearancetoserviceregulatorventoutlet. 3feet * *
J
Clearancetononmechanicalairsupplyinlet
tobuildingorthecombustionairinlettoany
otherapplication.
3feet 1foot
4feetfrombeloworside
opening.1footfrom
aboveopening.
K
Clearancetomechanicalairsupplyinlet. 6feet 3feet 3feet
L
Clearanceabovepavedsidewalkorpaved
drivewaylocatedonpublicproperty.
7feet * 7feet
M
Clearanceunderveranda,porchdeck,or
balcony.
1foot * *
*ForclearancesnotspecifiedinANSIZ223.1/NFPA54orCAN/CSAB149.1,pleaseuseclearancesinaccordancewith
localinstallationcodesandtherequirementsofthegassupplier.
Installation
16Page
Pleasefollowalllocalandnationalcodesinregardstoproperterminationclea rances.
Intheabsenceofsuchcodes,thefollowingclearancescanbeusedasguidelines.Local
codessupersedetheseguidelines.
Forsidewallterminations
Exhausttermination
1ft.
1ft.
2ft.
Inside
corner
Formultiplesidewallexhaust
terminations(e.g.multiunit
systems),anexhausttermination
mustbeatleast1ft.awayfrom
anotherexhaustterminati on.An
exhaustterminationmustalsobe
atleast2ft.awayfromaninside
corner(iftheadjacentwallisless
than2ft.oflength,theminimum
requireddistanceawayfromthe
insidecornerwillbeequaltothe
lengthofthatadjacentwall).
Fordirectventsidewall
terminationsthatusetwo
separatepenetrationsforthe
intakeandexhaust,distance
theintakeandexhaust
terminationsatleast3ft.away
fromeachother,nomatterthe
orientation.
Formultipleunit,directventsidewall
terminationsthatcombinetheintake
andexhaustintoasinglepenetration,
spaceeachdirectventterminationat
least1ft.awayfromeachother,no
mattertheorientation.Adirectvent
terminationmustalsobeatleast2ft.
awayfromaninsidecorner(if
the
adjacentwallislessthan2ft.of
length,theminimumrequired
distanceawayfromtheinsidecorner
willbeequaltothelengthofthat
adjacentwall).
Formultipleunitrooftopterminations(whetherforstandardindooror
directventinstallations)spaceallexhaustandintaketerminationsin
accordance
withlocalcodes.Anexhaustterminationmustbespacedfrom
awallorsurfaceinaccordancewithlocalcodesaswell.Intheabsenceof
suchacode,anexhaustterminationmustbeahorizontaldistanceofat
least2ft.awayfromawallorsurface.
A:Inaccordancewith
localcodes
Forrooftopterminations
Airintake
Exhaust termination
A
A
A
A
A
2ft.
Airintake
Exhaust
termination
Exhaustand/ordirectvent
sidewallterminationsshould
beatleast2ft.awayfroman
oppositesurface/wall.Do
notplacethetermina tion
directlyinfrontofan
openingintoabuilding.
2ft.
Exhaust
termination
Airsupplyinlet
3ft.
3ft.
3ft.
Directventtermination
1ft.
1ft.
Inside
corner
2ft.
CAUTION
Installation
17Page
Sizethegaspipeappropriatelytosupplythenecessaryvolumeofgasrequiredfor
thewaterheaterusingANSI233.1/NFPA54intheUSAorCAN/CSAB149.1inCanada
orlocalcodes.Otherwise,flowcapabilitiesandoutputtemperatureswillbelimited.
Checkthatthetypeofgasmatchestheratingplatefirst.
Ensure that any and all gas regulators used are operating properly and
providing gas pressures within the specified range shown below. Excess gas
inletpressuremaycauseseriousaccidents.
Conversion of this unit from natural gas to propane or vise versa will void all
warranty. Contact your local distributor to get the correct unit for your gas
type.The manufacturer is not liable for any property and/or personal
damageresultingfromgasconversions.
GASSUPPLYANDGASPIPESIZING
General‐
Theminimumandmaximuminletgaspressuresare:
Gastype Inletgaspressure
NaturalGas Min.5.0”WCMax.10.5”WC
Propane Min.8.0”WCMax.14.0”WC
Gas pressure above this specified range for the water heater and/or insufficient gas volume will
adversely affect performance.These pressures are measured when the water heater is in full
operation.
Inlet gas pressure must not exceed the above maximum values; gas pressure above the specified
rangewillcausedangerous
operatingconditionsanddamagetotheunit.
Until testing of the main gas line supply pressure is completed, ensure the gas line to the water
heaterisdisconnectedtoavoidanydamagetothewaterheater.
Gasconnections‐
1. Installamanualgasshutoffvalvebetweenthewaterheaterandthegassupplyline.
2. When the gas connections are completed, it is necessary to perform a gas leak test (see below)
eitherbyapplyingsoapywatertoallgasfittingsandobservingfor bubblesor byusing
a gasleak
detectiondevice.
Thewaterheater anditsindividualshutoff valvemustbe disconnected fromthe gassupply
pipingsystemduringanypressuretestingofthatsystemattestpressures inexcessof1/2psi
(3.5kPa).
Thewaterheatermustbeisolatedfromthegassupplypipingsystembyclosingitsindividual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressuresequaltoorlessthan1/2psi(3.5kPa).
3. Alwayspurgethegaslineofanydebrisand/orwater
beforeconnectingtothegasinlet.
WARNING
NOTICE
Installation
18Page
NaturalGasSupplyPiping‐
MaximumDeliveryCapacityofCubicFeetofGasperHourofIPSPipeCarryingNaturalGasof0.60SpecificGravity
BasedonPressureDropof0.5”WC
BasedonEnergyContentof1,000BTU/CubicFt.:Thewaterheaterrequires140CubicFt./hrfortheTKJr2IN/OS,
190CubicFt./hrfortheTK4IN/OS,and199CubicFt./hrfortheTD2IN/OS.
Unit:CubicFeetperHour
PipeSize LengthinFeet
Inches 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’ 125’ 150’ 200’
¾” 363 249 200 171 152 138 127 118 111 104 93 84 72
1” 684 470 377 323 286 259 239 222 208 197 174 158 135
1¼” 1,404 965 775 663 588 532 490 456 428 404 358 324 278
1½” 2,103 1,445 1,161 993 880 798 734 683 641 605 536 486 416
2” 4,050 2,784 2,235 1,913 1,696 1,536 1,413 1,315 1,234 1,165 1,033 936 801
Propane(LP)SupplyPiping‐
MaximumCapacityofPropane(LP)Basedon11”WCsupplypressureata0.5”WCpressuredrop
Unit:kBTUperHour
PipeSize
LengthinFeet
Inches
10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’ 125’ 150’ 200’
¾” 567 393 315 267 237 217 196 185 173 162 146 132 112
1” 1,071 732 590 504 448 409 378 346 322 307 275 252 213
1¼”2,205 1,496 1,212 1,039 913 834 771 724 677 630 567 511 440
1½” 3,307 2,299 1,858 1,559 1,417 1,275 1,181 1,086 1,023 976 866 787 675
2” 6,221 4,331 3,465 2,992 2,646 2,394 2,205 2,047 1,921 1,811 1,606 1,496 1,260
Formoreinformation,pleaseseethebelow.
BasedonEnergyContentof1,000BTU/CubicFt:
Divideeachappliance’sBTUrequirementby1,000BTUtoget
theappliancesCubicFt.requirement.
Takeintoaccountthedistancetheapplianceisfromthegas
meter,lookintheabovegascharttoproperlysizetheline.
Forsectionsofthegaslinesupplyinggastomorethanone
appliance(Ex:PointAtoPointB),addupthecubicft.
requirementsoftheappliancesthatarebeingsuppliedbythat
section,andsizetothefarthestappliance.
ForExample:ThesectionfromAtoBsuppliesgastothe
furnace,range,anddryer.AddinguptheBTUrequirements
anddividingby1,000yieldsacubicft.requirementof220
cubicft.ofgas.Thefarthestapplianceistherange,whichis50
ft.awayfromthemeter.Lookingattheabovechart,and
underthecolumnof50ft.,SectionAtoBneedstobe 1”in
ordertosupply220cubicft.
10’Length
1”PipeSize
C
GasSizingExample
(NaturalGas)
10’Length
3/4”PipeSize
15’Length
1/2”PipeSize
10’Length
1/2”PipeSize
Furnace
120,000BTU
Water
Heater
199,000BTU
5’Length
11/4”PipeSize
Range
65,000BTU
10’Length
3/4”PipeSize
Dryer
35,000BTU
15’Length
1”PipeSize
5’Length
11/4”PipeSize
GasMeter
B
A
Installation
19Page
1. Turnoffallelectricpowertothewaterheaterifserviceistobeperformed.
2. Turnthemanualgasvalvelocatedontheoutsideoftheunitclockwise3to
theoffposition.
Measuringinletgaspressure‐
Thewaterheatercannotperformproperlywithoutsufficientinletgaspressure.Belowareinstructions
onhowtochecktheinletgaspressure.THISISONLYTOBEDONEBYALICENSEDPROFESSIONAL.
1. Shutoffthemanualgasvalveonthesupplygasline.
2. Removethescrewforthe
pressureportlocatedon
thegasinletofthewaterheatershowninthe
diagramtotheright.
3. Connectthemanometertothepressureport.
4. Reopenthemanualgasvalve.Checktoseethat
therearenogasleaks.Opensomeofthefixtures
thatusethehighest
flowratetoturnonthewater
heater.
5. Checktheinletgaspressure.Whenthewaterheater
isonmaximumburn,themanometershouldread
from5.0”to10.5”WCforNaturalgas,from8.0”to
14.0”WCforPropane.
Pressureport
Installation
20Page
Do not use this water heater if any part has been submersed under water.
Immediatelycallalicensedprofessionaltoinspectthewaterheatertoreplace
anydamagedparts.
Donot reversethehot outletandcold inletconnectionstothe waterheater.
Thiswillnotproperlyactivatethewaterheater.
WATERCONNECTIONS
Allpipes,pipefittings,valvesandothercomponents,includingsolderingmaterials,mustbesuitablefor
potablewatersystems.
1. Amanual shutoffvalvemust be installed on the coldwaterinlet to the water heater between
themainwatersupplylineandthewaterheater.
2. In addition, a manual
shut off valve is also
recommended on the hot water outlet of the
unit. If the water heater is installed within, or
subjected to, a closed loop water system, a
thermalexpansiontankmustbeinstalled.
3. Before installing the water heater, flush the
water line to remove all debris,
and after
installation is complete, purge the air from the
line.Failuretodosomaycausedamagetothe
heater.
4. Thereis a wiremeshfilterwithinthe coldinlet
to trap debris from entering your heater. This
willneedtobecleanedperiodicallytomaintain
optimumflow.
Pressurereliefvalve‐
Thewaterheaterhas a hightemperature shutoff switch built inas astandard safetyfeature(calleda
HiLimitswitch)thereforea“pressureonly”reliefvalveisrequired.
Thisunitdoesnotcomewithanapprovedpressurereliefvalve.
Anapprovedpressurereliefvalvemustbeinstalled
onthehotwateroutlet.
ThepressurereliefvalvemustconformtoANSIZ21.22orCAN14.4andinstallationmustfollow
localcode.
The discharg e capacity must be at least 140,000 BTU/h for the TKJr2IN/OS, 190,000 BTU/h for
theTK4IN/OS,and199,000BTU/h
fortheTD2IN/OS.
Thepressurereliefvalveneedstoberatedforamaximumof150psi.
The dischargepipingfor thepressurereliefvalve mustbedirected sothatthehot watercannot
splashonanyoneoronnearbyequipment.
Attach the discharge tube to
the pressure relief valve and run the end of the tube to within 6"
from the floor. This discharge tube must allow free and complete drainage without any
restrictions.
Ifthepressurereliefvalve installedonthewaterheaterdischargesperiodically,thismaybedue
toadefectivethermal
expansiontankordefectivepressurereliefvalve.
Thepressurereliefvalvemustbemanuallyoperatedperiodicallytocheckforcorrectoperation.
Novalvemustbepla cedbetweenthereliefvalveandthewaterheater.
Pressure
ReliefValve
Hot
outle
t
Cold
inle
t
Gas
inle
t
AsCloseas
Possible
CAUTION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Takagi 510 Outdoor (T-D2-OS) Installation Manual And Owner's Manual

Type
Installation Manual And Owner's Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI