A.O. Smith ATI-310-P Technical Documents

  • Hello! I am an AI chatbot trained to assist you with the A.O. Smith ATI-310-P Technical Documents. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!





‐Do not store or use gasoline or other
flammablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
‐WHATTODOIFYOUSMELLGAS
ο‚· Donottrytolightanyappliance.
ο‚· Do not touch any electric switch, do not
useanyphonein
yourbuilding.
ο‚· Immediatelycallyourgassupplierfroma
neighbor's phone. Follow the gas
supplier'sinstructions.
ο‚· Ifyoucannotreachyourgassupplier,call
thefiredepartment.
‐Installation and service must be performed
byaqualifiedinstaller,serviceagencyorthe
gassupplier.






FEATURING
ο‚· ENDLESSHOTWATER
ο‚· ONDEMANDUSAGE
ο‚· COMPACT,SPACESAVING
ο‚· ENERGYCONSERVATION
ο‚· COMPUTERIZEDSAFETY
ο‚· NOPILOTLIGHT
ο‚· EASY‐LINKSYSTEM
510(T‐D2)modelsonly
GasTanklessWaterHeater
Suitableforpotablewater heating andspace‐hea ting
*
*Pleaserefertolocalcodesforspace‐heatingcompliance.
Ifyouhaveanyquestions,please
callorwriteto:
500TennesseeWaltzParkway
AshlandCity,TN37015
TollFree:1‐ 877‐737‐2840
On‐DemandWaterHeater
InstallationManualandOwner’sGuide
Models
・
110Indoor(T‐KJr2‐IN)
・
110Outdoor(T‐KJr2‐OS)
・
310Indoor(T‐K4‐IN)
・
310Outdoor(T‐K4‐OS)
・
510Indoor(T‐D2‐IN)
・
510Outdoor(T‐D2‐OS)
WARNING
Iftheinformationinthese
instructionsisnotfollowed
exactly,afireorexplosion
mayresultcausing
propertydamage,personalinjuryordeath.
ANSI Z21.10.3 andCSA4.3
510(T‐D2)models
only
Contents
2β”‚Page
CONTENTS



































SPECIFICATIONS…………………………………………………………………………………………..………………………...
INTRODUCTION…………………………………………………………………………………………………..………………….
SAFETYGUIDELINES…………….………………………………………………………………………………………..………..
INSTALLATION………………………………………………………………………………………………..…………………..….
General………………………………………………………………………………………………………………………..…..…
WarningforInstallations……………………………………………………………………………………………………
…
Clearances……………………………………………………………………………………………………………………………
IncludedAccessories…………….………………………………………………………………………………………..…..
OptionalItems……………………………………………………………………………………………………………………..
High‐AltitudeInstallations……………………………………………………………………………………………………
.
VentingInstructions…………………………………………………………………………………………………………….
.
GasSupplyandGasPipeSizing………......................................................................................…
WaterConnections……………..…………………………………………………………………………………………….…
ElectricalConnections……………………………………………………………………..…………………………….......
RemoteControllerConnections……..………………………………………………………………………………….
…
PumpControlConnections…………………………………………..………..………..…………………………………
…
Easy‐LinkSystem...…………………………....…………………………………………………………………………..…...
APPLICATIONS...………………………………………………………………………………………………………………………
INITIALOPERATION..………………………………………………………………………………………………………….……




OPERATINGSAFETY…………………………………………………………………………………………………………………
NORMALOPERATION…………………………………………………………………………………………………………..…
General………..……….………….…………………………………………………………………………………………………
TemperatureSettings.…….……..……………………………………………………………………………………………
Flow…………………………………………………………………………………………………………………………………….
FreezeProtectionSystem…….…………………………………………………………………………………………..…
MaintenanceandService………………………………………………………………………………………………….…
UnitDrainingandFilterCleaning…………………………………………………………………………………………
TROUBLESHOOTING……..……………………………………………………………………………………………………..…
General………..……….………….…………………………………………………………………………………………………
ErrorCodes.…………………….…..………………………………………………………………………………………………
COMPONENTSDIAGRAM……………………………………………………………………………………………………..…
PARTSLIST………………….………………………………………………………………………………………………..…………
OUTPUTTEMPERATURECHART…………………………………………………………………………………………...…
LIMITEDWARRANTY…………………………………………………………....…………………………………………….….

3
4
5
6
6
8
9
9
9
11
12
17
20
21
22
23
24
28
30




31
33
33
33
35
35
36
36
37
37
39
42
46
49
51



InstallationManual
Owner’sGuide
Specifications
3β”‚Page

SPECIFICATIONS
Model
110
Indoor
(T‐KJr2‐IN)
110
Outdoor
(T‐KJr2‐OS)
310
Indoor

(T‐K4‐IN)
310
Outdoor
(T‐K4‐OS)
510
Indoor
(T‐D2‐IN)
510
Outdoor
(T‐D2‐OS)
NaturalGasInput
(OperatingRange)
Min:19,500Btu/h
Max:140,000Btu/h
Min:11,000Btu/h
Max:190,000Btu/h
Min:11,000Btu/h
Max:199,000Btu/h
PropaneInput
(OperatingRange)
Min:19,500Btu/h
Max:140,000Btu/h
Min:11,000Btu/h
Max:190,000Btu/h
Min:11,000Btu/h
Max:199,000Btu/h
GasConnection ¾”NPT
WaterConnections
¾”NPT
WaterPressure 15‐150psi*
NaturalGas
InletPressure
Min.5.0”WC
Max.10.5”WC
Propane
InletPressure
Min.8.0”WC
Max.14.0”WC
Manifold
Pressure**
Natural 2.0”WC 2.5”WC 2.0”WC 2.5”WC 2.0”WC 2.5”WC
Propane 2.5”WC 3.1”WC 3.7”WC 4.0”WC 3.7”WC 4.5”WC
Weight 33lbs. 38lbs. 39lbs.
Dimensions
H20.5”xW13. 8”xD6.7”
H20.5”xW13.8”xD8.5”
Ignition ElectricIgnition
Electric
Supply 120VAC/60Hz
Consumption
Operation
73.1W/0.61A 87.6W/0.73A 89.8W/0.75A
Standby 6.2W/0.05A 6.2W/0.05A 6.2W/0.05A
Freeze‐
Protection
111W/0.93A 111W/0.93A 111W/0.93A
*40psioraboveisrecommendedformaximumflow.
**TheManifoldPressureisthefactorysettingandgenerallyshouldnotneedadjustment.
NOTE:
ο‚· Checktheratingplatetoensurethisproductmatchesyourspecifications.
ο‚· InaccordancewithANSIZ21.10.3,COemissiondoesnotexceed400PPMfor
normalinput.
ο‚· Themanufacturerreservestherighttodiscontinue,orchangeatanytime,
specificationsordesignswithoutnoticeandwithoutincurringobligations
.
I
I
I
n
n
n
s
s
s
a
a
a
l
l
l
l
l
l
a
a
a
i
i
i
o
o
o
n
n
n
M
M
M
a
a
a
n
n
n
u
u
u
a
a
a
l
l
l


Introduction
4β”‚Page
INTRODUCTION
*Thisdiagram
illustratestankless
waterheaterdesign
conceptsonlyand
doesnotaccurately
representtothewater
heater’sphysical
description.
ο‚· This manual provides information necessary for the installation, operation, and
maintenanceofthewaterheater.
ο‚· Themodeldescriptionislistedontheratingplatewhichisattachedtothefrontpanel
ofthewaterheater.
ο‚· Pleasereadallinstallationinstructionscompletelybeforeinstallingthisproduct.
ο‚· If you have any problems or questions regarding this equipment, consult with the
manufactureroritslocalrepresentative.
ο‚· Thisequipmentisanon‐demand,tanklesswaterheaterdesignedtoefficientlysupply
endlesshotwaterforyourneeds.
ο‚· Theprinciplebehindtanklesswaterheatersissimple:













1. Ahotwatertapisturnedon.
2. Waterenterstheheater.
3. Thewaterflowsensordetectsthewaterflow.
4. Thecomputerinitiatesthefanmoto randsendsasignaltotheignitertocreateanignition
spark.
5. Thegasignitesandflamesappear
withintheburnerchamber.
6. Watercirculatesthroughtheheatexchangerandthengetshot.
7. Usingthermistorstomeasuretemperaturesthroughoutthewaterheater,thecomputer
modulatesthegasandwatervalvestoensureproperoutputwatertemperature.
8. Whenthetapisturnedoff,theunitshutsdown.
ο‚· The 110 Indoor(T‐KJr2‐IN), 310 Indoor(T‐K4‐IN)and 510 Indoor(T‐D2‐IN) models are
tobeonlyinstalledindoor(direct‐ventconvertible).The110Outdoor(T‐KJr2‐OS),310
Outdoor(T‐K4‐OS)and510Outdoor(T‐D2‐OS)modelsaretobeonlyinstalledoutdoor.
SafetyGuidelines
5β”‚Page



ο‚· Watertemperaturesover125Β°F (52
Β°
C) cancausesevereburnsinstantlyordeath
from scalding. The watertemperature isset at 122Β°F (50Β°C)fromthe factory to
minimizeanyscaldingrisk.Beforebathingorshoweringalwayscheckthewater
temperature.
ο‚· Donotstoreorusegasolineorotherflammables,vapors,orliquidsinthevicinity
ofthisappliance.
ο‚· Do not reverse the water and/or gas connections as this will damage the gas
valvesand can cause severe injury ordeath.Followthediagramon p.20when
installingyourwaterheater.
ο‚· Donotusethisapplianceifanyparthasbeenincontactwithorbeenimmersed
in water. Immediately call a licensed plumber, a licensed gas fitter, or a
professionalservicetechniciantoinspectand/orservicetheunitifnecessary.
ο‚· Do not disconnect the electrical supply if the ambient temperature will drop
belowfreezing.TheFreezePreventionSystemonlyworksiftheunithaselectrical
power.Thewarrantywillnotbecoverediftheheatexchangerisdamageddueto
freezing.RefertothesectionontheFreezePreventionSystemon
p.35formore
information.
SAFETYGUIDELINES

SAFETYDEFINITIONS
Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,willresultin
deathorseriousinjury.
Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,couldresult
indeathorseriousinjury.
Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,couldresult
inminorormoderateinjury.
GENERAL
1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the
NationalFuelGasCode:ANSIZ223.1/N FPA54intheUSAorCAN/CSAB149.1NaturalGas,Propane
InstallationCodeinCanada.
2. Properlygroundtheunitinaccordancewithalllocalcodesor
intheabsenceoflocalcodes,with
theNationalElectrical Codes:ANSI/NFPA 70in the USA orCSAstandard C22.1 Canada Electrical
CodePart1inCanada.
3. Carefullyplanwhereyouintendtoinstallthewaterhe ater.Pleaseensure:
ο‚· Yourwaterheaterwillhaveenoughcombustibleairand
properventilation.
ο‚· Locateyourheaterwherewaterleakagewillnotdamagesurround ingareas(pleaserefer
top.7).
4. ChecktheratingplateforthecorrectGASTYPE,GASPRESSURE,WATERPRESSUREandELECTRIC
RATING.
*Ifthisunitdoesnotmatchyourrequirements,donotinstallandcon sultwiththe
manufacturer.
5. Ifany problemshould occur, turnoffall hot water tapsand turnoffthe gas.Then call a trained
technicianortheGasCompanyorthemanufacturer.
WARNING
CAUTION
DANGER
WARNING
Installation
6β”‚Page
INSTALLATION
GENERAL

1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the
National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the USA or CAN/C SA B149.1 Natural Gas,
PropaneInstallationCodeinCanada.

2. Allgaswaterheatersrequirecarefulandcorrectinstallationto
ensuresafeandefficient
operation.Thismanualmustbefollowedexactly.Readtheξ€ƒβ€œSafetyGuidelines”se ction.

3. Themanifoldgaspre s sureispresetatthefactory.Itiscomputercontrolledandshouldnot
needadjustment.

4. Maintainproperspaceforservicing.Installtheunitsothatitcanbe
connectedorremo ved
easily.RefertotheClearancesSectiononp.9forproperclearances.


5. Thewaterheatermustbeinstalledinalocationwheretheproperamountofcombustibleair
willbeavailabletoitatalltimeswithoutobstructions.

6. Theelectricalconnectionrequiresameansofdisconnection,toterminatepowertothewater
heaterforservicingandsafetypurposes.


7. Donotinstalltheunitwheretheexhaustventispointingintoanyopeninginabuildingorwhere
thenoisemaydisturbyourneighbors.Makesuretheventterminationmeetstherequired
distancebylocalcodefromanydoorwayoropeningtopreventexhaustfromenteringabuilding
(refer
top.15).

8. Particlesfromflour,aerosols,andothercontaminantsmayclogtheairventorreducethe
functionsoftherotatingfanandcauseimproperburningofthegas.Regularlyensurethatthe
areaaroundtheunitisdust‐ordebris‐free;regularmaintenanceisrecommendedforthese

typesofenvironment.

9. Ifyouwillbein stallingthewaterheaterinacontaminatedareawithahighlevelofdust,sand,
flour,aerosolsorothercontaminants/chemicals,theycanbecomeairborneandenterandbuild
upwithinthefanandburnercausingdamagetothewaterheater.


10. Forthe110Indoor(T‐KJr2‐IN),310Indoor(T‐K4‐IN)and510Indoor(T‐D2‐IN)models:
ο‚· Theseunitsmaybeconvertedtoadire ct‐vent(sealedcombustion)appliancebyinstallinga
direct‐vent conversion kit Part No. 9007667005 (TK‐TV10) which will bring in all required

combustible air fromoutside thebuilding.When installingthe direct‐vent conversion kit,
pleasefollowallinstructionsincludedwiththekit.
ο‚· Ifthewaterheaterisusedasadirect‐ventappliance,theunitrequiresa3”combustibleair
supply pipe. Theintakepipe mustbesealed airtight.Air
supply pipecan be made of ABS,
PVC, galvanized steel, corrugated aluminum, corrugated stainless steel or Category III
stainlesssteel.
ο‚· Terminatingtheventingthroughasidewallisrecommendedforthedirect‐ventsystem.
ο‚· Runningtheexhaustventandtheintakepipeparallelisrecommended.
ο‚· Terminating the exhaust and
 intake on the same wall / surface is recommended.
Terminating in the same pressure zone allows for pressure balancing, which prevents
nuisanceshutdowns.

11. Forthe110Outdoor(T‐KJr2‐OS),310Outdoor(T‐K4‐OS)and510Outdoor(T‐D2‐OS)models:
ο‚· Tobeinstalledoutdoorsandonlyinareaswithmild,temperateclimates.
Installation
7β”‚Page
ο‚· Installation and service must be performed by a qualified installer (for
example, a licensed plumber or gas fitter), otherwise the warranty will be
void.
ο‚· The installer(licensedprofessional)isresponsibleforthecorrectinstallation
of the water heater and for compliance with all national, state/provincial,
andlocalcodes.
ο‚· The manufacturerdoesnotrecommendinstallingthewaterheaterin apitor
locationwheregasandwatercanaccumulate.
ο‚· Donothavetheventterminalpointingtowardanyoperatingwindow,door,or
openingintoabuilding.
ο‚· Do not install next to any source ofairborne debris, such as a clothes dryer,
that can cause debris to be trapped inside the combustion chamber, unless
thesystemisdirect‐vented.
ο‚· The  manufacturer does not recommend installing the water heater in an
atticduetosafetyissues.Ifyouinstallthewaterheaterinanattic:

ο‚· Makesuretheunitwillhaveenoughcombustionairandproperventilation.
ο‚· Keep the area around the water heater clean. When dust collects on the
flamesensor,thewaterheaterwillshutdownonanerrorcode.

ο‚· If the above conditions cannot be met, use the direct vent  conversion kit
PartNo.9007667005(TK‐TV10).

ο‚· Placetheunitforeasyaccessforserviceandmaintenance.
ο‚· A drain pan, or other means of protection against water damage, is
re
q
uiredtobeinstalledunderthewaterheaterincaseofleaks.
ο‚· The warrantywillnotcoverdamagecausedbywaterquality.
ο‚· Onlypotablewaterorpotablewater/glycolmixturescanbeusedwiththis
water heater.Do not introduce pool or spa water, or any chemically
treatedwaterintothewaterheater.
ο‚· Water hardness levels must not exceed 7 grains per gallon (120 ppm) for
single family domestic applications or more than 4 grains per gallon (70
ppm) for all other types of applications.Water hard ness leads to scale
formation and may affect/damage the water heater.Hard water scaling 
mustbeavoidedor
controlledbyproperwatertreatment.
ο‚· WaterpHlevelsmustbebetween6.5and8.5
ο‚· Wellwatermustbetreated.
ο‚· Donotinstalltheunitwherewater,debris,orflammablevaporsmaygetinto
theflueterminal.
ο‚· The  manufacturer recommends using the direct vent kit when the water
heateris installed in abeauty salon. Some chemicalsusedin a beautysalon
mayaffecttheflamesensor.Waterheatermaynotworkproperly.
ο‚· Although the water heater is designed to operate with minimal sound, the
manufacturerdoesnotrecommendinstallingtheunitonawalladjacenttoa
bedroom,oraroomthatisintendedforquietstudyormeditation,etc.
ο‚· Locateyourheaterclosetoadrainwherewaterleakagewillnotdodamageto
surrounding areas.As with any  water heating appliance, the potential for
leakageatsometimein thelifeoftheproductdoesexist.Themanufacturer
willnotberesponsibleforanywaterdamagethatmayoccur.
Ifyou installa
drain pan under the unit, ensure that it will not restrict the combustion  air
flow.




CAUTION
WARNING
Installation
8β”‚Page

WARNINGFORINSTALLATIONS
FORYOURSAFETY,READBEFOREINSTALLATION:
Do not install the heater where water, debris or
flammablevaporsmaygetintotheflueterminal.
This may cause damage to the heater and void
thewarranty.


Do not have the vent terminal pointing toward
any opening into a building. Do not locate your
heater in a pit or
location where gas and water
canaccumulate.




Donotinstallthiswaterheaterunderan
overhanglessthan3feetfromitstoporeaves.
Theareaunderanoverhangmustbeopento
threesides.(Outdoormodelsonly)

Do not install the water heater vent terminator
within1ft.intheUSAofanyairintake
orbuilding
opening, and within 3 ft. in Canada of any air
intake or building opening. (Outdoor models
only)(Refertop.15)


Donotinstallnexttoadryeroranysourceof
airbornedebristhatcanbetrappedinsidethe
combustionchamber,unlessthesystemisdirect
vented.
Prohibited
Prohibited
FORYOURSAFETY,READBEFOREINSTALLATION:
3ft.
Installation
9β”‚Page

CLEARANCES








Model Top Bottom Front Back Sides
110Indoor*(T‐KJr2‐IN)* 12” 12” 24” 1” 2ξ€ƒβ€œξ€ƒ
110Outdoor(T‐KJr2‐OS) 36” 12” 24” 1” 2ξ€ƒβ€œξ€ƒ

Model Top Bottom Front Back Sides
310Indoor*(T‐K4‐IN)* 12” 12” 24” 1” 2ξ€ƒβ€œξ€ƒ
310Outdoor(T‐K4‐OS) 36” 12” 24” 1” 2ξ€ƒβ€œξ€ƒ

Model Top Bottom Front Back Sides
510Indoor*(T‐D2‐IN)* 12” 12” 24” 1” 2ξ€ƒβ€œξ€ƒ
510Outdoor(T‐D2‐OS) 36” 12” 24” 1” 2ξ€ƒβ€œξ€ƒ
*Standardindoorinstallationsanddirect‐ventindoorinstallationshavethesameclearances.
INCLUDEDACCESSORIES
Checkthattheseitemsbelowareincludedwiththewaterheater.
1. InstallationManualand
Owner’sGuide

2.
TemperatureRemoteController
3.CommunicationCable
510(T‐D2)modelsonly


OPTIONALITEMS
Model
110Indoor
(T‐KJr2‐IN)
110Outdoor
(T‐KJr2‐OS)
310Indoor
(T‐K4‐IN)
310Outdoor
(T‐K4‐OS)
510Indoor
(T‐D2‐IN)
510Outdoor
(T‐D2‐OS)
9007666005
(TK‐RE02)
βœ”ξ€ƒ βœ”ξ€ƒ βœ”ξ€ƒ βœ”ξ€ƒ
 
9007603005
(TM‐RE30)
   
βœ”ξ€ƒ βœ”ξ€ƒ
9007678005
(TK‐BF01)
βœ”ξ€ƒ

βœ”ξ€ƒ

βœ”ξ€ƒ

9007667005
(TK‐TV10)
βœ”ξ€ƒ

βœ”ξ€ƒ

βœ”ξ€ƒ

9007670005
(TK‐PC01)
 
βœ”ξ€ƒ βœ”ξ€ƒ βœ”ξ€ƒ βœ”ξ€ƒ
9007671005
(TK‐PCJr2)
βœ”ξ€ƒ βœ”ξ€ƒ
   
9007674005
(TK‐RB02)

βœ”ξ€ƒ

βœ”ξ€ƒ

βœ”ξ€ƒ
9007608005
(TK‐KPWL4)
9007609005
(TK‐KPWH4)
βœ”ξ€ƒ

βœ”ξ€ƒ

βœ”ξ€ƒ

9007680005
(TK‐KPCT43)
βœ”ξ€ƒ

βœ”ξ€ƒ

βœ”ξ€ƒ

Qty:1
Qty:1
Maintain all clearances around
thewaterheater.
Bottom
Side
Top
Side
Front
Back
Seethetablebelow.
Qty:1
or
Installation
10β”‚Page
1. Temperature Remote Controller: 9007666005
(TK‐RE02)
The Temperature Remote Controller
has two functions. It allows the
output temperature from the water
heater to be adjusted within the
range of 99 Β°F to 167 Β°F, and it also
works as a diagnostic tool that will
give a concise error code whenever
there is a  problem with the unit.
 The temperature
options are 99Β°F, 100Β°F, 102Β°F, 104Β°F, 106Β°F, 108Β°F,
109Β°F,111Β°F,113Β°F,115Β°F,117Β°F,122Β°F,131Β°F,140Β°F,
158Β°F,and167Β°F.See the trouble shooting sectionfor
informationonpossibleerrorcodes.
2. Temperature Remote Controller: 9007603005
(TM‐RE30)
The Temperature Remote Controller
has two functions. It allows the
output temperature from the water
heater to be adjusted within the
range of 99 Β°F to 185 Β°F, and it also
works as a diagnostic tool that will
giveaconciseerrorcodewheneverthereisaproblem
withtheunit.
Thetemperatureoptionsare99Β°F,100Β°F,
102Β°F,104Β°F,106Β°F,108Β°F,110Β°F,111Β°F,113Β°F,115Β°F,
117Β°F, 122Β°F, 131Β°F, 140Β°F, 149Β°F, 158Β°F, 167Β°F, 176Β°F
and 185Β°F. See the trouble shooting section for
informationonpossibleerrorcodes.
3.BackflowPreventer:9007678005(TK‐BF01)
The Backflow preventer prevents the
backflow of air through the exhaust
vent.Thishelpspreventharmfulexhaust
gasesfromenteringthehome,aswellas
helpingtopreventtheunitfromfreezing
inareaswherecoldaircanbeblown or
drawnintotheexhaustsystem.Installthisventdamper
in
accordancewiththeinstallationinstructionsandany
applicablecodes.
4.Direct‐Vent ConversionKit:9007667005
(TK‐TV10)
Thiskitcanbeusedtoconvert
thewaterheaterfroma
standardventsystemtoa
direct‐vent(orsealed
combustion)system.Install
thisconversionkitin
accordancewiththe
installationinstructionsand
anyapplicablecodes.
5.PipeCovers:9007670005(TK‐PC01)and
9007671005(TK‐PCJr2)
The pipe cover protects the plumbing
pipes to the water heater from
unexpected adjustments.This pipe
cover is fixed to the bottom of the
water heater, which hides the
plumbing and improves the visual
aspects of the whole installation for
thewaterheater.
6. Recessbox:9007674005(TK‐RB02)
TheRecessboxwillallowforξ€ƒβ€œclean”
installations.Thewaterheaterfitsinside
therecessbox,whichhidesandprotects
thewholewaterheaterandplumbing.
TheRecessboxwillfitin‐betweenmost
wallstuds.
7.T‐VentWallThimblewithTermination:9007608005(TK‐KPWL4)and9007609005(TK‐KPWH4)
Theseterm in ation s are usedwhenventingoutthrough thewalland are
compatiblewith theT‐Ventpipesystem.
Theseterm inationsarespecialstainlesssteelventsforgasappliancesandare
ULlistedasCategoryII,IIIand IV.Therear etwotyp es of termination s:the
Louverterminat ionandtheHo od
termination .Fo rdifferentwallthi cknesses, 
thereare tworangesoflengthsavailable(refertotheventingbrochurefor
details).
Installtheseventt er min ationsinaccordancewithth ei r installation
instructionsand anyapplicablelocalcodes.

8.Direct‐VentConcentricTermination:9007680005(TK‐KPCT43 )
Usedwhenterminatingdirect‐vent(sealed‐combustion)systems,withdirect‐
ventmodelsthatrequirea3”intakeanda4”exhaust.Thisconcentric
terminationprovidestheconvenienceofonlyhavingtomakeonepenetration
throughasidewallinsteadoftwoseparatepenetrationsfortheintakeand
exhaustpiping.Theterminationincludes
abirdscreen,restrictingsmallanimals,
pests,andforeignobjectsfromenteringintotheventsystem.Thissidewall
terminationisavailableinthreedifferentsizes,tocoverallrangesofwall
thicknesses.
Direct‐ventConcentricTermination
Part# Coveringwallthickness
9007680005(TK‐KPCT43‐1) 3.9”
–
7.1”
9007772005(TK‐KPCT43‐2) 6.9”
–
10.1”
9007773005(TK‐KPCT43‐3) 9.8”
–
13.0”
Louver
Termination
9007608005
(TK‐KPWL4)
Hood
Termination
9007609005
(TK‐KPWH4)
Installation
11β”‚Page
ο‚· DONOTadjustanydipswitchesontherightbankforthe510(T‐D2)models.
ο‚· Thedarksquaresindicatethedirectionthedipswitchesshouldbesetto.
Dipswitches
HIGH‐ALTITUDEINSTALLATIONS

Checktheelevationwhereyourwaterheaterisinstalled.Setdipswitchesshowninthetablebelow
dependingonthealtitude.



Altitude
0to2,000ft
(DEFAULT)
2,000to4,000ft
4,000to6,000ft Over6,000ft
SwitchNo.3 OFF
ON
OFF
Consult
our Technical
Services
Department
at1‐877‐
737‐2840
SwitchNo.4 OFF
OFF
ON

Altitude
0to2,000ft
(DEFAULT)
2,000to4,000ft
4,000to6,000ft Over6,000ft
SwitchNo.4 OFF
ON
OFF
Consult
our Technical
Services
Department
at1‐877‐
737‐2840
SwitchNo.5 OFF
OFF
ON
110(T‐KJr2)and310(T‐K4)models
510(T‐D2)models(Leftbankofdipswitches)
110(T‐KJr2)and310(T‐K4)models
Computerboard
WARNING
510
(
T‐D2
)
modelsCom
p
uterboard
Leftbankofdipswitches
O
F
F
O
N
1
2
3
4
5
6
7
8
O
F
F
O
N
1
2
3
4
5
6
7
8
O
F
F
O
N
1
2
3
4
5
6
7
8
O
F
F
O
N
1
2
3
4
5
6
O
F
F
O
N
1
2
3
4
5
6
O
F
F
O
N
1
2
3
4
5
6
Installation
12β”‚Page
Improperventingofthisappliancecanresultinexcessivelevelsofcarbon
monoxidewhichcanresultinseverepersonalinjuryordeath.

Improperinstallationcancausenauseaorasphyxiation,severeinjuryordeathfrom
carbonmonoxideandfluegasespoisoning.Improperinstallationwillvoidproduct
warranty.

Wheninstallingtheventsystem,allapplicablenationalandlocalcodesmustbe
followed.Ifyouinstallthimbles,firestopsorotherprotectivedevicesandthey
penetrateanycombustibleornoncombustibleconstruction,besuretofollowall
applicablenationalandlocalcodes.

VENTINGINSTRUCTIONS
‐General‐
Thewaterheatermustbeventedinaccordance withthesectionξ€ƒβ€œVentingofEquipment"ofthelatest
editionoftheNationalFuelGasCod e : ANSIZ223.1/NFPA54intheUnitedStatesand/orSection7ofthe
CAN/CSA B149.1 Natural Gas and Propane Installation Code in
Canada, as well as applicable local
buildingcodes.

The manufacturer recommends the β€œT‐Vent” line manufactured by TAKAGI (Refer to β€œT‐Vent”
brochure for det ails). However, the  following are also UL listed manufacturers: ProTech Syste ms  Inc.
(FasNSeal),Flex‐LInc.,Z‐FlexInc.(Z‐VentIII),Metal‐FabInc.,andHeat‐FabInc.(Saf‐TVent) .


Generalrulesforventingwaterheatersare:
ο‚· Placethewaterheaterascloseaspossibletotheventterminator.
ο‚· Theventcollarofthewaterheatermustbefasteneddirectlytoanunobstructedventpipe.
ο‚· Donotweldtheventpipetothewaterheater’sventcollar.
ο‚· Donotcuttheventcollaroftheunit.
ο‚· Theventmustbeeasilyremovablefromthetopofthewaterheaterfornormalserviceand
inspectionoftheunit.
ο‚· Thewaterheaterventmustnotbeconnectedtoanyothergasapplianceorventstack.
ο‚· Avoid
usinganoversizedventpipeorusingextremelylongrunsofthepipe.
ο‚· Forrooftopventing,araincaporotherformofterminationthatpreventsrainwaterfrom
enteringintothewaterheatermustbeinstalled.
ο‚· Donotcommonventorconnectanyventfromotherappliances
tothewaterheatervent.

Generalrulesforventterminations:
ο‚· Avoidlocatingthewaterheaterventterminatornearanyairintakedevices.Thesefanscan
pickupthe exhaust flueproducts fromthewater heater andreturnthem to the building.
Thiscancreateahealthhazard.
ο‚· Locate the vent terminator so that
 it cannot be blocked by any debris, at any time. Most
codesrequirethattheterminatorbeatleast12inchesabove grade,buttheinstallermay
determineifitshouldbehigherdependingonthejobsiteconditionandapplicablecodes.
ο‚· Apropersidewall terminatoris recommendedwhen
thewaterheaterisventedthrougha
sidewall.
ο‚· Regardingtheclearancesfrom the exhaustterminator tothe airinlet or opening, referto
thenextfewpages.
CAUTION
DANGER
Installation
13β”‚Page
‐Exhaustventing‐
Forthe110Indoor(T‐KJr2‐IN),310Indoor(T‐K4‐IN)and510Indoor
(T‐D2‐IN)models

ThisisaCategoryIIIapplianceandmustbeventedaccordingly.Theventsystemmustbesealedairtight.
AllseamsandjointswithoutgasketsmustbesealedwithhighheatresistantsiliconesealantorULlisted
aluminumadhesivetapehavingaminimumtemperatureratingof350Β°F.Forbestresults,a
vent system
shouldbeasshortandstraightaspossible.
ο‚· ThiswaterheaterisaCategoryIIIapplianceandmustbeventedaccordinglywithany4”vent
approvedforusewithCategoryIIIorSpecialBHtypegasvent .
ο‚· Followtheventpipemanufacturer’sinstructionswheninstallingthe
ventpipe.
ο‚· Donotcommonventthisappliancewithanyotherventedappliance(Donotterminatevent
into a chimney.If the vent must go through the chimney, the vent must run all the way
throughthechimneywithCategoryIIIapprovedorSpecialBHventpipe).
ο‚· When
the horizontal vent run  exceeds 5 ft., support the vent run at 3 ft. intervals with
overheadhangars.
ο‚· The maximumlengthofexhaust ventpipingmustnotexceed50ft.(deducting5ft.foreach
elbowusedintheventingsystem).Donotusemorethan5elbows.
Diameter Max.No.ofElbow Max.VerticalandHorizontal(Total)VentLength
4” 5 50ft.
*Foreachelbowadded,deduct5ft.frommax.Ventlength.
No.ofElbows Max.VerticalorHorizontalLength
0 50ft.
1 45ft.
2 40ft.
5 25ft.
‐VentingIllustrations‐
Forthe110Indoor(T‐KJr2‐IN),310Indoor(T‐K4‐IN)and510Indoor
(T‐D2‐IN)models

HorizontalInstallationDiagram
VerticalInstallationDiagram
SidewallVent
Terminator
Wall
BackflowPreventer*
VerticalCondensationDrain**
Fordetailsoftheoptionalitems,refertothe InstallationmanualforeachOptionalitem.
Roo
f
VerticalCondensation
Drain**
RoofFlashing
RainCap
BackflowPreventer*
Installation
14β”‚Page

*BackflowPreventer (Recommendedforfreezingweatherconditions:36
Β°
F andbelow)
**VerticalCondensationDrainmustbeinstalledaccordancewithlocalcodes.
HorizontalInstallationDiagram
WithDirect‐VentConcentric
Termination
HorizontalInstallationDiagram
(Withdirect‐venting)
VerticalInstallationDiagram
(Withdirect‐venting)
Thewaterheater
Intakeportof
Direct‐Vent
ConversionKit

InstallationDiagramofDirect‐Vent
ConversionKitwithwaterheater
Wall
Direct‐vent
Concentric
Termination
PlateofDirect‐VentConversionKit

Seethepicturebelowfordetailedconnection
instructionstotheDirect‐VentConversionKit.
VerticalCondensationDrain**

Backflow
Preventer*
Wall
Sidewall
Vent
Terminator
RoofFlashing
Vertical
Condensation
Drain**
Backflow
Preventer*
RainCap
Roo
f
Firestop
Installation
15β”‚Page

‐Ventterminationclearances‐


Canada U.S.A
Directventand
otherthanDirect
Vent
Directvent OtherthanDirectVent
A
Clearanceabovegrade,veranda,porch,deck,
orbalcony.
1foot 1foot 1foot
B
Clearancetowindowordoorthatmaybe
opened.
3feet 1foot
4feetfrombeloworside
opening.1footfrom
aboveopening.
C Clearancetopermanentlyclosedwindow * * *
D
Verticalclearancetoventilatedsoffitlocated
abovetheventterminatorwithinahorizontal
distanceof2feet(61cm)fromthecenterline
oftheterminator.
* * *
E Clearancetounventilatedsoffit * * *
F Clearancetooutsidecorner * * *
G Clearancetoinsidecorner * * *
H
Clearancetoeachsideofcenterlineextended
abovemeter/regulatorassembly
3feet * *
I Clearancetoserviceregulatorventoutlet. 3feet * *
J
Clearancetonon‐mechanicalairsupplyinlet
tobuildingorthecombustionairinlettoany
otherapplication.
3feet 1foot
4feetfrombeloworside
opening.1footfrom
aboveopening.
K Clearancetomechanicalairsupplyinlet. 6feet 3feet 3feet
L
Clearanceabovepavedsidewalkorpaved
drivewaylocatedonpublicproperty.
7feet * 7feet
M
Clearanceunderveranda,porchdeck,or
balcony.
1foot * *
*ForclearancesnotspecifiedinANSIZ223.1/NFPA54orCAN/CSA‐B149.1,pleaseuseclearancesinaccordancewith
localinstallationcodesandtherequirementsofthegassupplier.
Installation
16β”‚Page
Pleasefollowalllocalandnationalcodesinregardstoproperterminationclearances.
Intheabsenceofsuchcodes,thefollowingclearancescanbeusedasguidelines.Local
codessupersedetheseguidelines.



Forsidewallterminations

Exhausttermination
1ft.
1ft.
2ft.
Inside
corner
Formultiplesidewallexhaust
terminations(e.g.multi‐unit
systems),anexhausttermination
mustbeatleast1ft.awayfrom
anotherexhausttermination.An
exhaustterminationmustalsobe
atleast2ft.awayfromaninside
corner(iftheadjacentwallisless
than2ft.oflength,theminimum

requireddistanceawayfromthe
insidecornerwillbeequaltothe
lengthofthatadjacentwall).
Fordirect‐ventsidewall
terminationsthatusetwo
separatepenetrationsforthe
intakeandexhaust,distance
theintakeandexhaust
terminationsatleast3ft.away
fromeachother,nomatterthe
orientation.
Formultiple‐unit,direct‐ventsidewall
terminationsthatcombinetheintake
andexhaustintoasinglepenetration,
spaceeachdirect‐ventterminationat
least1ft.awayfromeachother,no
mattertheorientation.Adirect‐vent
terminationmustalsobeatleast2ft.
awayfromaninsidecorner(if
the
adjacentwallislessthan2ft.of
length,theminimumrequired
distanceawayfromtheinsidecorner
willbeequaltothelengthofthat
adjacentwall).
Formultiple‐unitrooftopterminations(whetherforstandardindooror
direct‐ventinstallations)spaceallexhaustandintaketerminationsin
accordance
withlocalcodes.Anexhaustterminationmustbespacedfrom
awallorsurfaceinaccordance withlocalcodes aswell.Intheabsenceof
suchacode,anexhaustterminationmustbeahorizontaldistanceofat
least2ft.awayfromawallorsurface.
A:Inaccordancewith
localcodes
Forrooftopterminations

Airintake
Exhausttermination
A
A
A
A
A
2ft.
Airintake
Exhaust
termination
Exhaustand/ordirect‐vent
sidewallterminationsshould
beatleast2ft.awayfroman
oppositesurface/wall.Do
notplacethetermination
directlyinfrontofan
openingintoabuilding.
2ft.
Exhaust
termination
Airsupplyinlet
3ft.
3ft.
3ft.
Directventtermination
1ft.
1ft.
Inside
corner
2ft.
CAUTION
Installation
17β”‚Page
Sizethegaspipeappropriatelytosupplythenecessaryvolumeofgasrequiredfor
thewaterheaterusingANSI233.1/NFPA54intheUSAorCAN/CSAB149.1inCanada
orlocalcodes.Otherwise,flowcapabilitiesandoutputtemperatureswillbelimited.
ο‚· Checkthatthetypeofgasmatchestheratingplatefirst.
ο‚· Ensure that any and all gas regulators used are operating properly and
providing gas pressures within the specified range shown be low. Excess gas
inletpressuremaycauseseriousaccidents.
ο‚· Conversion of thisunit from naturalgas to propane orvise versa will void all
warranty. Contact your local distributor to get the correct unit for your gas
type.The manufacturer is not liable for any property and/or personal
damageresultingfromgasconversions.

GASSUPPLYANDGASPIPESIZING
‐General‐

ο‚· Theminimumandmaximuminletgaspressuresare:
Gastype Inletgaspressure
NaturalGas Min.5.0”WC–Max.10.5”WC
Propane Min.8.0”WC–Max.14.0”WC
ο‚· Gas pressure above this specified range for the water heater and/or insufficient gas volume will
adversely affect performance.These pressures are measured when the water heater is in full
operation.
ο‚· Inlet gas pressuremust not exceedthe above maximumvalues; gas pressureabove the specified
rangewillcausedangerous
operatingconditionsanddamagetotheunit.
ο‚· Until testing of the main gas line supply pressure is completed, ensure the gas line to the water
heaterisdisconnectedtoavoidanydamagetothewaterheater.



‐Gasconnections‐
1. Installamanualgasshut‐offvalvebetweenthewaterheaterandthegassupplyline.
2. When the gas connections are completed, it is necessary to perform a gas leak test (see below)
eitherbyapplyingsoapywatertoallgasfittingsandobserving for bubblesorbyusing
agasleak
detectiondevice.
ο‚· Thewaterheater anditsindividualshutoff valve mustbedisconnectedfromthegassupply
pipingsystemduringanypressuretestingofthatsystemattestpressuresinexcessof1/2psi
(3.5kPa).
ο‚· Thewaterheatermustbeisolatedfromthegassupplypipingsystembyclosingitsindividual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressuresequaltoorlessthan1/2psi(3.5kPa).
3. Alwayspurgethegaslineofanydebrisand/orwater
beforeconnectingtothegasinlet.






WARNING
NOTICE
Installation
18β”‚Page


‐NaturalGasSupplyPiping‐
MaximumDeliveryCapacityofCubicFeetofGasperHourofIPSPipeCarryingNaturalGasof0.60SpecificGravity
BasedonPressureDropof0.5”WC

BasedonEnergyContentof1,000BTU/CubicFt.:Thewaterheaterrequires140CubicFt./hrforthe110(T‐KJr2)
models,190CubicFt./hrforthe310(T‐K4)models,and199CubicFt./hrforthe510(T‐D2)models.
Unit:CubicFeetperHour
PipeSize Length
Diameter 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’ 125’ 150’ 200’
¾” 363 249 200 171 152 138 127 118 111 104 93 84 72
1” 684 470 377 323 286 259 239 222 208 197 174 158 135
1¼” 1,404 965 775 663 588 532 490 456 428 404 358 324 278
1½” 2,103 1,445 1,161 993 880 798 734 683 641 605 536 486 416
2” 4,050 2,784 2,235 1,913 1,696 1,536 1,413 1,315 1,234 1,165 1,033 936 801
‐Propane(LP)SupplyPiping‐
MaximumCapacityofPropane(LP)Basedon11”WCsupplypressureata0.5”WCpressuredrop
Unit:kBTUperHour
PipeSize
Length
Diameter
10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’ 125’ 150’ 200’
¾” 567 393 315 267 237 217 196 185 173 162 146 132 112
1” 1,071 732 590 504 448 409 378 346 322 307 275 252 213
1¼” 2,205 1,496 1,212 1,039 913 834 771 724 677 630 567 511 440
1½” 3,307 2,299 1,858 1,559 1,417 1,275 1,181 1,086 1,023 976 866 787 675
2” 6,221 4,331 3,465 2,992 2,646 2,394 2,205 2,047 1,921 1,811 1,606 1,496 1,260
Formoreinformation,pleaseseethebelow.






BasedonEnergyContentof1,000BTU/CubicFt:

Divideeachappliance’sBTUrequirementby1,000BTUtoget
theappliancesCubicFt.requirement.

Takeintoaccountthedistancetheapplianceisfromthegas
meter,lookintheabovegascharttoproperlysizetheline.

Forsectionsofthegasline
supplyinggastomorethanone
appliance(Ex:PointAtoPointB),addupthecubicft.
requirementsoftheappliancesthatarebeingsuppliedbythat
section,andsizetothefarthestappliance.

ForExample:ThesectionfromAtoBsuppliesgastothe
furnace,range,anddryer.
AddinguptheBTUrequirements
anddividingby1,000yieldsacubicft.requirementof220
cubicft.ofgas.Thefarthestapplianceistherange,whichis50
ft.awayfromthemeter.Lookingattheabovechart,and
underthecolumnof50ft.,SectionAtoBneeds
tobe1”in
ordertosupply220cubicft.
10’Length
1”PipeSize
C
GasSizingExample
(NaturalGas)
10’Length
3/4”PipeSize
15’Length
1/2”PipeSize
10’Length
1/2”PipeSize
Furnace
120,000BTU
Water
Heater
199,000BTU
5’Length
1‐1/4”PipeSize
Range
65,000BTU
10’Length
3/4”PipeSize
Dryer
35,000BTU
15’Length
1”PipeSize
5’Length
1‐1/4”PipeSize
GasMeter
B
A
Installation
19β”‚Page
1. Turnoffallelectricpowertothewaterheaterifserviceistobeperformed.
2. Turnthemanualgasvalvelocatedontheoutsideoftheunitclockwiseto
theoffposition.

‐Measuringinletgaspressure‐







Thewaterheatercannotperformproperlywithoutsufficientinletgaspressure.Belowareinstructions
onhowtochecktheinletgaspressure.THISISONLYTOBEDONEBYALICENSEDPROFESSIONAL.

1. Shutoffthemanualgasvalveonthesupplygasline.
2. Removethescrewforthe
pressureportlocatedon
thegasinletofthewaterheatershowninthe
diagramtotheright.
3. Connectthemanometertothepressureport.
4. Re‐openthemanualgasvalve.Checktoseethat
therearenogasleaks.Opensomeofthefixtures
thatusethehighest
flowratetoturnonthewater
heater.
5. Checktheinletgaspressure.Whenthewaterheater
isonmaximumburn,themanometershouldread
from5.0”to10.5”WCforNaturalgas,from8.0”to
14.0”WCforPropane.





Pressureport
Installation
20β”‚Page
ο‚· Do not use this water heater if any part has been submersed under water.
Immediatelycallalicensedprofessionaltoinspectthewaterhe atertoreplace
anydamagedparts.
ο‚· Donotreverse thehotoutletandcold inletconnections tothewaterheater.
Thiswillnotproperlyactivatethewaterheater.
WATERCONNECTIONS
Allpipes,pipefittings,valvesandothercomponents,includingsolderingmaterials,mustbesuitablefor
potablewatersystems.
1. A  manualshutoff valvemust be installedon the cold waterinlet to thewaterheaterbetween
themainwatersupplylineandthewaterheater.
2. In addition, a manual
 shut off valve is also
recommended on the hot water outlet of the
unit. If the water heater is installed within, or
subjected to, a closed loop water system, a
thermalexpansiontankmustbeinstalled.
3. Before installing the water heater, flush the
water line to remove all debris,
and after
installation is complete, purge the air fromthe
line.Failuretodosomaycausedamagetothe
heater.
4. The re is awiremesh filterwithinthecold inlet
to trap debris from entering your heater. This
willneedtobecleanedperiodicallytomaintain
optimumflow.
‐Pressurereliefvalve‐
Thewaterheaterhasahigh‐temperatureshutoffswitchbuiltinas a standard safety feature(calleda
Hi‐Limitswitch)thereforeaξ€ƒβ€œpressureonly”reliefvalveisrequired.
ο‚· Thisunitdoesnotcomewithanapprovedpressurereliefvalve.
ο‚· Anapprovedpressurereliefvalvemustbeinstalled
onthehotwateroutlet.
ο‚· ThepressurereliefvalvemustconformtoANSIZ21.22orCAN1‐4.4andinstallationmustfollow
localcode.
ο‚· The discharge capacity must be at least 140,000 BTU/h for the 110 (T‐KJr2) models, 190,000
BTU/hforthe310(T‐K4)models,and
199,000BTU/hforthe510(T‐D2)models.
ο‚· Thepressurereliefvalveneedstoberatedforamaximumof150psi.
ο‚· Thedischargepipingforthepressurereliefvalvemustbedirectedsothatthehotwatercannot
splashonanyoneoronnearbyequipment.
ο‚· Attach the
 discharge tube to the pressure relief valve and run the end of the tube to within 6"
from the floor. This discharge tube must allow free and  complete drainage without any
restrictions.
ο‚· Ifthepressurereliefvalveinstalledonthewaterheaterdischargesperiodically,thismaybedue
to
adefectivethermalexpansiontankordefectivepressurereliefvalve.
ο‚· Thepressurereliefvalvemustbemanuallyoperatedperiodicallytocheckforcorrectoperation.
ο‚· Novalvemustbeplacedbetweenthereliefvalveandthewaterheater.
Pressure
ReliefValve
Hot
outlet
Cold
inlet
Gas
inlet
AsCloseas
Possible
CAUTION
/