Installation
10│Page
1. Temperature Remote Controller: 9007666005
(TK‐RE02)
The Temperature Remote Controller
has two functions. It allows the
output temperature from the water
heater to be adjusted within the
range of 99 °F to 167 °F, and it also
works as a diagnostic tool that will
give a concise error code whenever
there is a problem with the unit.
The temperature
options are 99°F, 100°F, 102°F, 104°F, 106°F, 108°F,
109°F,111°F,113°F,115°F,117°F,122°F,131°F,140°F,
158°F,and167°F.See the trouble shooting sectionfor
informationonpossibleerrorcodes.
2. Temperature Remote Controller: 9007603005
(TM‐RE30)
The Temperature Remote Controller
has two functions. It allows the
output temperature from the water
heater to be adjusted within the
range of 99 °F to 185 °F, and it also
works as a diagnostic tool that will
giveaconciseerrorcodewheneverthereisaproblem
withtheunit.
Thetemperatureoptionsare99°F,100°F,
102°F,104°F,106°F,108°F,110°F,111°F,113°F,115°F,
117°F, 122°F, 131°F, 140°F, 149°F, 158°F, 167°F, 176°F
and 185°F. See the trouble shooting section for
informationonpossibleerrorcodes.
3.BackflowPreventer:9007678005(TK‐BF01)
The Backflow preventer prevents the
backflow of air through the exhaust
vent.Thishelpspreventharmfulexhaust
gasesfromenteringthehome,aswellas
helpingtopreventtheunitfromfreezing
inareaswherecoldaircanbeblown or
drawnintotheexhaustsystem.Installthisventdamper
in
accordancewiththeinstallationinstructionsandany
applicablecodes.
4.Direct‐Vent ConversionKit:9007667005
(TK‐TV10)
Thiskitcanbeusedtoconvert
thewaterheaterfroma
standardventsystemtoa
direct‐vent(orsealed
combustion)system.Install
thisconversionkitin
accordancewiththe
installationinstructionsand
anyapplicablecodes.
5.PipeCovers:9007670005(TK‐PC01)and
9007671005(TK‐PCJr2)
The pipe cover protects the plumbing
pipes to the water heater from
unexpected adjustments.This pipe
cover is fixed to the bottom of the
water heater, which hides the
plumbing and improves the visual
aspects of the whole installation for
thewaterheater.
6. Recessbox:9007674005(TK‐RB02)
TheRecessboxwillallowfor“clean”
installations.Thewaterheaterfitsinside
therecessbox,whichhidesandprotects
thewholewaterheaterandplumbing.
TheRecessboxwillfitin‐betweenmost
wallstuds.
7.T‐VentWallThimblewithTermination:9007608005(TK‐KPWL4)and9007609005(TK‐KPWH4)
Theseterm in ation s are usedwhenventingoutthrough thewalland are
compatiblewith theT‐Ventpipesystem.
Theseterm inationsarespecialstainlesssteelventsforgasappliancesandare
ULlistedasCategoryII,IIIand IV.Therear etwotyp es of termination s:the
Louverterminat ionandtheHo od
termination .Fo rdifferentwallthi cknesses,
thereare tworangesoflengthsavailable(refertotheventingbrochurefor
details).
Installtheseventt er min ationsinaccordancewithth ei r installation
instructionsand anyapplicablelocalcodes.
8.Direct‐VentConcentricTermination:9007680005(TK‐KPCT43 )
Usedwhenterminatingdirect‐vent(sealed‐combustion)systems,withdirect‐
ventmodelsthatrequirea3”intakeanda4”exhaust.Thisconcentric
terminationprovidestheconvenienceofonlyhavingtomakeonepenetration
throughasidewallinsteadoftwoseparatepenetrationsfortheintakeand
exhaustpiping.Theterminationincludes
abirdscreen,restrictingsmallanimals,
pests,andforeignobjectsfromenteringintotheventsystem.Thissidewall
terminationisavailableinthreedifferentsizes,tocoverallrangesofwall
thicknesses.
Direct‐ventConcentricTermination
Part# Coveringwallthickness
9007680005(TK‐KPCT43‐1) 3.9”
7.1”
9007772005(TK‐KPCT43‐2) 6.9”
10.1”
9007773005(TK‐KPCT43‐3) 9.8”
13.0”
Louver
Termination
9007608005
(TK‐KPWL4)
Hood
Termination
9007609005
(TK‐KPWH4)