RAB CD34FA is a high-quality, affordable, well-designed, and energy-efficient LED lighting fixture suitable for wet locations and various mounting options. It features adjustable output distribution and color temperature, allowing you to customize the lighting to your specific needs. The fixture is easy to install, with clear instructions provided, and it comes with a gasket for wet locations and a cord clamp for pendant cord or pole mount applications.

RAB CD34FA is a high-quality, affordable, well-designed, and energy-efficient LED lighting fixture suitable for wet locations and various mounting options. It features adjustable output distribution and color temperature, allowing you to customize the lighting to your specific needs. The fixture is easy to install, with clear instructions provided, and it comes with a gasket for wet locations and a cord clamp for pendant cord or pole mount applications.

INSTRUCTIONS
CYLINDER INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and
end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
CD34FA3W-10-508-XX CD34FA4W-20-508-XX CD34FA6W-36-708-XX
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required
for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING:
• Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
• Fixture is suitable for wet location.
• Fixture must be mounted a minimum of 4 feet above ground level.
WALL MOUNT WHAT’S IN THE BOX
Junction Box
Adaptor Plate
WALL MOUNT INSTALLATION
1. Remove (2) M4*8 Screws on two sides and separate Junction
Box Adaptor Plate from the Fixture. (Fig. 1)
(2) M4*8 Screws
Fig: 1
WALL MOUNT INSTALLATION (cont’d)
2. Stick Gasket and fix Junction Box Adaptor Plate with (2) M4*30
Tapping Screws on the wall. (Fig. 2)
(Warning: The mark ”UP” direction must be installed upside.)
Fig: 2
3. Connect the wires with (3) P3 Wire Nuts according to Wiring
Diagram. (Fig. 3) (Fig. 31)
Fig: 3
Important: For wet locations, Gasket must be used.
CD34FA4SP-20-509-XX CD34FA6SP-30-709-XX
Gasket (3) P3 Wire NutsFixture
(2) M4*30
Tapping Screws
Wall Mount
Ceiling Mount
(3) P3 Wire Nuts
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and
end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
INSTRUCTIONS
CYLINDER INSTALLATION
CEILING MOUNT INSTALLATION
4. Mount back the Fixture on Junction Box Adaptor Plate with
(2) M4*8 Screws tightly. (Fig. 4)
Fig: 4
5. Unscrew Plug A to adjust the output distribution selectable and
CCT (Default: Output distribution selectable-Full; CCT-3000K).
When set down, screw back Plug A. (Fig. 5)
Fig: 5
WALL MOUNT INSTALLATION (cont’d)
6. Unscrew Plug B to turn ON/OFF Photocell (Default: Photocell-
OFF). When set down, screw back Plug B. (Fig. 6)
Fig: 6
Fig: 8
(2) M4*30
Tapping Screws
3. UnscrewPlug Ato adjust the CCT (Default-3000K). When set
down, screw backPlug A. (Fig. 9)
Fig: 9
Fig: 10
4. FixCanopyback to the Fixture. (Fig. 10)
F
1. Unscrew Junction Box Adaptor Plate and Canopy off the
Fixture counterclockwise. Remove Screw A from Canopy and
separate Junction Box Adaptor Plate and Canopy. (Fig. 7)
Fig: 7
Screw A
Junction Box
Adaptor Plate
Canopy
Fixture
CEILING MOUNT WHAT’S IN THE BOX
Important: For wet locations, caulk the seam between the fixture
and ceiling.
3K-3000K
4K-4000K
5K-5000K
Plug A
Cord Clamp with
Screw C
Thread
LockFixture
(2) M4*30
Tapping Screws
OFF
ON
Plug B Plug A
27K
30K
35K
40K
50K
Screw C
2. Fix Junction Box Adaptor Plate into junction box with (2) M4*30
Tapping Screws. (Fig. 8)
(3) P3 Wire Nuts (2) P2 Wire Nuts
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and
end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
INSTRUCTIONS
CYLINDER INSTALLATION
PENDANT CORD/ PENDANT POLE MOUNT (cont’d)
CEILING MOUNT INSTALLATION (cont’d)
PENDANT CORD/ PENDANT POLE MOUNT
Fig: 17
(2) M4*30
Tapping Screws
Fig: 18
5. Connect Tether Cable on Canopy to Tether Slot in Junction Box
Adaptor Plate. (Fig. 18)
Screw A
Junction Box
Adaptor Plate
Canopy
Fixture
1. Unscrew Junction Box Adaptor Plate and Canopy off the
Fixture counterclockwise. Remove Screw A from Canopy and
separate Junction Box Adaptor Plate and Canopy. (Fig. 14)
Fig: 14
Important: For wet locations, caulk the seam between the fixture
and ceiling.
Plug A
27K
30K
35K
40K
50K
Fig: 15
2. PassThread Lockthrough theCordand tighten it securely.
(Fig. 15)
Fig: 16
3. UnscrewPlug Ato adjust the CCT (Default-3000K). When set
down, screw backPlug A. (Fig. 16)
Cord
Thread Lock
Thread Lock
Tether
Slot
Tether
Cable
Fig: 12
6. Connect the wires with (3) P3 Wire Nuts and (2) P2 Wire Nuts
according to Wiring Diagram. (2) P2 Wire Nuts are for dimming
wires. (Fig. 12) (Fig. 32)
Fig: 11
5. Connect Tether Cable on Canopy to Tether Slot in Junction Box
Adaptor Plate. (Fig. 11)
Tether
Slot
Tether
Cable
7. Align the holes onCanopyandJunction Box Adaptor Plateto
fixCanopyback toJunction Box Adaptor Platecounterclockwise
and tighten them withScrew A. (Fig. 13)
Fig: 13
Screw A
4. Fix Junction Box Adaptor Plate into junction box with (2) M4*30
Tapping Screws. (Fig. 17)
(3) P3 Wire Nuts
(2) P2 Wire Nuts
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and
end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
INSTRUCTIONS
CYLINDER INSTALLATION
CORD TO POLE CONVERSION
PENDANT CORD/ PENDANT POLE MOUNT (cont’d)
3. ThreadCordontoHollow Studand tighten them securely. (Fig. 24)
Fig: 24
Fig: 21
8. FixCanopyback toJunction Box Adaptor Plateand tighten
them withScrew A. (Fig. 21)
Screw A Hollow Stud
Note: Please refer to RAB CD34STEM-X. Poles are sold separately.
1. Remove Cord ClampwithScrew C, Canopy, Tether Cablewith
Screw B, Junction Box Adaptor PlatewithScrew A Discard
Thread Lock. (Fig. 22)
Fig: 22
2. InsertCordthroughPole section. ScrewPolesection toFixture.
Add up to 3 morePolesections as required. Each pole section is
12” long. A minimum of 6 inches will be needed for connecting to
the power supply wires located in the junction box. (Fig. 23)
Fig: 23
Pole
Screw A
Screw B
Canopy
Junction Box
Adaptor Plate
Cord Clamp
with Screw C
Cord
Thread Lock
Tether Cable
Fig: 20
7. Connect the wires with (3) P3 Wire Nuts and (2) P2 Wire Nuts
according to Wiring Diagram. (2) P2 Wire Nuts are for dimming
wires.(Fig. 20) (Fig. 32)
Fig: 19
6. Pass Cord Clamp through the Cord. AdjustCordlength according
to requirement and tightenCord Clamp with Screw C.
A minimum of 6 inches will be needed for connecting to the
power supply wires located in the junction box.
Cord Clamp
Screw C
(3) P3 Wire Nuts
(2) P2 Wire Nuts
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and
end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
INSTRUCTIONS
CYLINDER INSTALLATION
Fig: 27
(2) M4*30
Tapping Screws
(L) Black
(N) White
(G) Yellow/Green
LED
FIXTURE
LED
FIXTURE
(L) Black
(N) White
(G) Yellow/Green
Dim+ Purple
Dim- Pink
0-10V
Dimming
WIRING DIAGRAM
Fig: 31
Fig: 32
CORD TO POLE CONVERSION (cont’d)
Note: These instructions do not cover all details or variations in equipment nor do they
provide for every possible situation during installation, operation or maintenance.
Fig: 30
9. FixCanopyback toJunction Box Adaptor Plateand tighten
them withScrew A. (Fig. 30)
Fig: 29
8. Connect the wires with (3) P3 Wire Nuts and (2) P2 Wire Nuts
according to Wiring Diagram. (2) P2 Wire Nuts are for dimming
wires. (Fig. 29) (Fig. 32)
Screw A
5. Unscrew M10 Outside Hexagonal Hollow Nut to Canopy and fix
Canopy to Pole through M10 Outside Hexagonal Hollow Nut.
(Fig. 26)
Fig: 26
6. Fix Junction Box Adaptor Plate into junction box with (2) M4*30
Tapping Screws. (Fig. 27)
Fig: 28
6. Connect Tether Cable on Canopy to Tether Slot in Junction Box
Adaptor Plate. (Fig. 28)
Tether
Slot
Tether
Cable
Fig: 25
4. UnscrewPlug Ato adjust the CCT (Default-3000K). When set
down, screw backPlug A. (Fig. 25)
Plug A
27K
30K
35K
40K
50K
M10 Outside
Hexagonal
Hollow Nut
CORD TO POLE CONVERSION (cont’d)
(3) P3 Wire Nuts
(2) P2 Wire Nuts
CD34FA-IN 0822
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly - sales@rablighting.com
Free Lighting Layouts
Answered online or by request
© 2022 RAB LIGHTING Inc.
Cranbury, New Jersey 08512 USA
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and
end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
INSTRUCTIONS
CYLINDER INSTALLATION
CD34FA4SP-20-509-XX
CD34FA6SP-30-709-XX
Ceiling Mount
6''
150mm
7''
172mm
9''
224mm 8''
192mm
3'' 87mm
4''
104mm
Ø5''
127mm
5''
124mm
12''
297mm
Ø3 3/8''
85mm
Ø2 9/16''
65mm
4 1/2''
115mm
4 1/2''
115mm
153mm
Ø6”
22mm
7/8''
22mm
7/8''
CD34FA3W-10-508-XXCD34FA4W-20-508-XX
Wall Mount
Wall Mount
10''
259mm
5''
130mm
4 1/2''
115mm
8''
194mm
153mm
Ø6”
CD34FA6W-36-708-XX
DIMMENSIONAL DRAWINGS
CAUTION: Be sure xture temperature is cool enough to touch.
Do not clean or maintain while xture is energized.
CLEANING & MAINTENANCE
1. Do not open fixture to clean the LED. Do not touch the LED.
2. Do not touch reflector.
3. Do not clean any fixture surface with wood-base cleaning
material such as paper towels or tissues.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer to
wiring directions.
2. Is the fixture grounded properly?
DIMMENSIONAL DRAWINGS (cont’d)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

RAB CD34FA Operating instructions

Type
Operating instructions

RAB CD34FA is a high-quality, affordable, well-designed, and energy-efficient LED lighting fixture suitable for wet locations and various mounting options. It features adjustable output distribution and color temperature, allowing you to customize the lighting to your specific needs. The fixture is easy to install, with clear instructions provided, and it comes with a gasket for wet locations and a cord clamp for pendant cord or pole mount applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI