The Gen IV controller has the ability to
communicate over the Chrysler PFCS protocol
over Ethernet or one of the serial ports. Once the
controller is connected to the desired network,
several parameters are used to congure its
behavior on the PFCS network.
From the main menu, select Controller.
Select Protocols.
Then select PFCS.
Server IP Address:
The IP address of
the PFCS server.
If the server is on
another sub-net,
verication of the
gateway in the
Ethernet settings
is required. This
parameter is not
used for a serial
connection to
PFCS.
Server Port
Number: The
TCP port server
is listening for a
new connection.
Parameter is not
used for a serial
connection to
PFCS.
Acknowledge
Time Out (sec): Amount of time controller will wait
for an acknowledge from the PFCS server.
Number of Retries: Number of times controller will
retry a message if not answered by the PFCS server.
Reconnect Time Out (sec): Amount of times
controller waits before attempting to re-connect
to PFCS server.
Connection Inactivity Time (sec): Amount of time
controller waits before sending a “keep alive”
message.
Auto Machine ID: When boxed is checked,
controller will request a machine ID from PFCS.
When box is not checked, controller will use the
programmed one from each parameter set.
Gen IV Controller
PFCS Instructions
QUALITY • INNOVATION • SERVICE LIT-MAN177_PFCS
07-07-22
©2022 AIMCO
CORPORATE HEADQUARTERS
10000 SE Pine Street
Portland, Oregon 97216
Phone: (503) 254–6600
Toll Free: 1-800-852-1368
AIMCO CORPORATION DE MEXICO SA DE CV
Ave. Cristobal Colon 14529
Chihuahua, Chihuahua. 31125
Mexico
Phone: (01-614) 380-1010
  • Page 1 1

AcraDyne iEC4EGV Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI