ThermoFisher Scientific Q33230 User guide

Type
User guide

ThermoFisher Scientific Q33230 Qubit 1X dsDNA HS Assay Kit empowers life science researchers with accurate and rapid DNA quantification for various applications. It quantifies DNA samples from 200 pg/µL to 1000 ng/µL in just two minutes, enabling quick and efficient downstream analysis.

ThermoFisher Scientific Q33230 Qubit 1X dsDNA HS Assay Kit empowers life science researchers with accurate and rapid DNA quantification for various applications. It quantifies DNA samples from 200 pg/µL to 1000 ng/µL in just two minutes, enabling quick and efficient downstream analysis.

QUICK REFERENCEQUICK REFERENCE Qubit Assays
For Research Use Only. Not for use in diagnostic procedures.
Pub. No. MAN 0017210
Rev. C.0
QUICK REFERENCE
Qubit Assays
1. Set up two assay tubes for the standards (three for
the protein or RNA IQ assay) and one assay tube for
each sample.
2. Prepare the Qubit working solution by diluting the
Qubit reagent 1:200 in Qubit buer. Prepare 200 μL of
working solution for each standard and sample.
3. Prepare the assay tubes* according to the table below.
Standard assay tubes User sample assay tubes
Working solution (from step 2) 190 μL 180 –199 μL
Standard (from kit) 10 μL
User sample 1–20 μL
Total Volume in each assay tube 200 μL 200 μL
Qubit 1X dsDNA assays (Cat. Nos. Q33230, Q33231, Q33265, Q33266) are supplied with a ready-to-use working solution, and do not require preparation.
* Use only thin-wall, clear 0.5 mL PCR tubes. Acceptable tubes include Qubit assay tubes (set of 500, Cat. No. Q32856).
General Qubit Assay Protocol
4. Vortex all tubes for 2–3 seconds.
5. Incubate the tubes for 2 minutes at room temperature
(15 minutes for the Qubit protein assay).
6. Insert the tubes in the Qubit Fluorometer and take
readings. For detailed instructions, refer to the Qubit
Fluorometer manual.
Standards from kit
User samples
Qubit
buffer
Qubit reagent
Ensure all reagents are
at room temperature
Qubit
working solution
1 × n μL*
199 × n μL*
* where n = number of standards plus number of samples
190 μL
180-199 μL
Final Qubit volume tube is 200 μL
Final Qubit tube volume is 200 μL
1-20 μL 1-20 μL 1-20 μL
10 μL 10 μL
1. Set up two assay tubes for the standards, one assay tube
for a buer blank and one assay tube for each sample.
2. Prepare assay tubes according to the table below. Adding
solutions in the following order to the assay tubes: (1)
Standards/Sample/Sample Buer, (2) Protein BR Assay
Buer, (3) Protein BR Assay Reagent.
3. Vortex for 5-7 seconds immediately after addition of
Protein BR Assay Reagent.
4. Incubate tubes for 10 minutes at room temperature.
5. Insert the tubes in the Qubit Fluorometer and take
readings. For detailed instructions, refer to the Qubit
Fluorometer manual.
For Research Use Only. Not for use in diagnostic procedures. © 2021 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are
the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. 12 March 2021
Find out more at thermofisher.com/qubit
Limited Product Warranty
Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life
Technologies’ General Terms and Conditions of Sale found on Life Technologies’ website at www.
thermofisher.com/us/en/home/global/terms-and-conditions.html. If you have any questions, please
contact Life Technologies at www.thermofisher.com/support.
The information in this document is subject to change without notice.
DISCLAIMER: TO THE EXTENT ALLOWED BY LAW, THERMO FISHER SCIENTIFIC AND/OR ITS
AFFILIATE(S) WILL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR
CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING
YOUR USE OF IT.
Important Licensing Information: These products may be covered by one or more Limited Use Label
Licenses. By use of these products, you accept the terms and conditions of all applicable Limited Use
Label Licenses.
Manufacturer: Multiple Life Technologies Corporation manufacturing sites are responsible for
manufacturing the products associated with the workflow covered in this guide.
For Qubit Protein BR Assay only
Standard assay tubes Buffer blank User sample assay tubes
Standard (from kit) 20 µL - -
User sample buffer -10 or 20 µL -
User sample - - 10 or 20 µL
Protein BR Assay Buffer 150 µL 150 or 160 µL 150 or 160 µL
Protein BR Assay Reagent 30 µL 30 µL 30 µL
Total volume in each assay tube 200 µL 200 µL 200 µL
STD 1 STD 2 Sample Blank
Protein BR
Assay Buffer
Step 1: Prepare
assay tubes
Protein BR
Reagent
Add 10 or 20 µL Mix & vortex for 5 sec
Final volume is 200 µL
Add 30 µL
Add 150 or 160 µL
Step 2: Add Protein BR
Assay Buffer
Step 3: Add Protein
BR Reagent
Step 4: Incubate for
10 min at RT
Step 5:
Read samples