1. Safety & Environmental Information
Keep flam mable m aterials away from the installation (such as curtains). A lot of energy is transferred into heat. The installation
should be such that the amount of air flow required for safe operation of the equipment is n ot compromised. Proper ventilation must
be provided.
ESD and LE Ds:
LED components us ed in R -Series LE D sheets are E SD (Electro-Static D ischarge) sensitive. To p revent the pos sibility of des troying
LED components do not touch either in operation or while switched off.
Risk of electric shock / Risk of fire:
To protect against risk of fi re caused by overloading of power c ables, each power source cable should be p rotected by a type D
circuit breaker r ated 16 A / 250 VAC (20 A / 250 VA C in the USA and C anada).
For the 200–240 VA C range up to three PSUs can be c onnected to one circuit at the sam e time. For the 100–130 VA C range up to
two P SUs can be connected to one circuit at the s ame time.
Disconnect device:
The socket outlets supp lying one or m ore R-Series products shall be installed near the equipment and be easily accessible, or a
readily accessible general disconnect device must be incorporated in the fixed wiring.
Unplug / disconnect all mains input connections to remove all power from the R -Series products.
The disconnect device sh all simultaneously interrupt all poles of the AC mains supply, ex cept for the ea rthing conductor. This shall
be installed near the equipment and be easily accessible.
This equipment M US T b e earthed:
In order to pro tect against r isk of e lectric shock, the installation should b e
properly grounded ac cording to local regulations. Defeating
the purpose of the gr ounding type plug will expose you to the risk of electric shock.
Power system:
It is recommended to use a TN-S power distribution system (a pow er distribution system with a separate neutral and grounding
conductor) in order to avoid large ground current loops due to voltage differences in the neutral conductor. The total electrical
installation should be protected by an appropriately rated disconnect switch, circuit breakers, over voltage protector and Ground Fault
Current Interrupters. The installation shall be done ac cording to the local electrical installation codes. In Europe s pecial attention
should be given to HD 60364, Harmon ization Document for electrical installation of buildings. In Germ any VDE 0100 should be
adhered to. In A meric a, special attention should b e given to the National Electrical Code, ANSI/NFPA 70.
Data cables:
The data cables provided with this system have special properties for safety. They are not user serviceable. If the data cables are
damaged, replace them only with new ones. Never try to repair a data cab
le. Per requirements of the N ational Electrical Code® in
the USA , the length of a data cable must not exceed 100 m (328 feet). Avoid exposure of data c ables to accidental contact with
lightning or power conductors.
Only use data cables provided by Barco. The diameter of the cables provided b y B arco is chosen to fit the co nnection box. Only
these cables c an guarantee the water tightness of the system.
Mains co rds:
The power cords delivered w ith this system have special properties for safety; they are not u ser serviceable. If the power cords a re
damaged, replace them only with new ones. Never try to repair a power cord.
LED s :
The LED s used on the R-series s heets are fragile. Never push with a hard or sharp object onto the lens of the LE D as this may
cause damage to the LED. The maximum allowed load upon the lens of the LE D is 300 gram/LED, but only a force perpendicular to
the s creen surface is allowed. Be careful when installing a shader upon the R-series sheet. Shaders fit in one of tw o directions and
the orientation sh ould be verified before pushing into final position. Use your bare fingers ( not nails) to press the shader over the
LEDs. Use your finger nails to press upon the framework of the shader between the LEDs (not upon the LEDs ) to pus h the shader
in its final position.
Do not hot plug:
Do not hot plug any cables. Damage to the connector pins may occur. Re sulting dam age is not covered under warranty.
Base surface:
The R-Series LED sheets cannot be directly installed on the wall. An electrically grounded aluminium back plate must be
installed between that wall and the LED sheets.
To e nsure a correct thermal expansion (CTE) and electromagnetic c ompatibility (EM C), Barco provides a solution with Reynobond®
panels, a specific foam tape and various installation brackets. These optional parts are a dded externally to the certified R-series
product.
When not using this Barco verifie d solution the following needs to be taken into account:
• Only install base surfaces consisting of noncombustible material or self-extinguishing material.
• Make sure the LED sheets a re not ac cessible for non-qualified personnel.
• Makesuretoprovidesufficient extra mechanical safeties (e.g. safety cables) according to local regulations.
Loosening
4
R5906040 R-SERIES 16/02/2017