ESAB Arc 201i A33 Caddy User manual

Type
User manual

This manual is also suitable for

Caddy®
Service manual
0740 800 185 GB 20181205
Valid for: serial no. 803-, 828-, 927-, 747-, 840-xxx-xxxx
Arc 151i A33        
Arc 201i A33
TABLE OF CONTENTS
0740 800 185 © ESAB AB 2018
READ THIS FIRST.................................................................................... 4
INTRODUCTION....................................................................................... 5
WIRING DIAGRAM................................................................................... 6
Component description ......................................................................... 6
Arc 151i A33, valid for serial no. 803-, 828 and 927-xxx-xxxx ............ 8
Arc 151i A33, valid for serial no. 747 and 840-xxx-xxxx ..................... 10
Arc 201i A33, valid for serial no. 803-, 828 and 927-xxx-xxxx ............ 12
Arc 201i A33, valid for serial no. 747 and 840-xxx-xxxx ..................... 14
TECHNICAL DATA ................................................................................... 16
Valid for serial no. 803-, 828-, 927-xxx-xxxx......................................... 16
Valid for serial no. 747-, 840-xxx-xxxx .................................................. 17
DESCRIPTION OF OPERATION.............................................................. 19
1 MMC module ........................................................................................ 19
2AP1 Power supply board ..................................................................... 19
2AP1:1 Interference suppressor circuit ................................................ 20
2AP1:2 Primary circuit.......................................................................... 21
2AP1:3 Secondary circuit ..................................................................... 22
2AP1 Component positions.................................................................. 23
15AP1 Power board................................................................................ 26
Charging circuit .................................................................................... 27
Power factor corrector (PFC)................................................................ 27
Gate driver stages ................................................................................ 27
Switching circuit.................................................................................... 27
Supply to 2AP1..................................................................................... 28
15AP1 Component positions................................................................ 28
15AP2 Secondary board ........................................................................ 28
15AP2 Component positions................................................................ 29
20AP1 Control board.............................................................................. 29
20AP1:1 Power supply ......................................................................... 30
20AP1:2 Control panel interface circuits .............................................. 31
20AP1:3 Remote control input ............................................................. 31
20AP1:4 Pulse width modulator ........................................................... 32
20AP1:5 Temperature monitoring......................................................... 32
20AP1:6 Shunt and current control amplifier........................................ 33
20AP1:7 Arc voltage feedback ............................................................. 33
20AP1:8 TIG functions ......................................................................... 34
20AP1:9 Welding process control ........................................................ 34
20AP1:10 Power-up starting sequence................................................ 35
20AP1 Component positions................................................................ 36
FAULT CODES ......................................................................................... 38
TABLE OF CONTENTS
0740 800 185 © ESAB AB 2018
SERVICE INSTRUCTIONS....................................................................... 39
What is ESD? .......................................................................................... 39
Service aid .............................................................................................. 39
Checking the semiconductor module of 15AP1 .................................. 41
Checking rectifier and freewheel diodes ............................................. 42
Checking the gate pulses ...................................................................... 43
Soft starting ............................................................................................ 45
Mounting components on the heat sink............................................... 47
SPARE PARTS ......................................................................................... 49
Rights reserved to alter specifications without notice.
READ THIS FIRST
0740 800 185
- 4 -
© ESAB AB 2018
READ THIS FIRST
Maintenance and repair work must be performed by an experienced person, and electrical
work only by a trained electrician. Use only recommended replacement parts.
This service manual is intended for use by technicians with electrical/electronic training for
help in connection with fault-tracing and repair.
Use the wiring diagram as a form of index for the description of operation. The circuit boards
are divided into numbered blocks, which are described individually in more detail in the
description of operation. Component names in the wiring diagram are listed in the
component description.
Use the spare parts list as a guide to where the components are located in the equipment.
The spare parts list is published as a separate document, see the "SPARE PARTS" chapter
in this manual.
This manual contains details of design changes that have been made up to and including
November 2017.
The manual is valid for:
Arc 151i A33 with serial no. 803-xxx-xxxx, 828-xxx-xxxx, 927-xxx-xxxx, 747-xxx-xxxx
and 840-xxx-xxxx
Arc 201i A33 with serial no. 803-xxx-xxxx, 828-xxx-xxxx, 927-xxx-xxxx, 747-xxx-xxxx
and 840-xxx-xxxx
The Arc 151i and Arc 201i are designed and tested in accordance with international
and European standards IEC/EN 60974. On completion of service or repair work, it is
the responsibility of the person(s) performing the work to ensure that the product still
complies with the requirements of the above standard.
INTRODUCTION
0740 800 185
- 5 -
© ESAB AB 2018
INTRODUCTION
Design structure of the power source
Block diagram of the Arc 151i and Arc 201i
The power source is transistor-controlled, operating on the inverter principle. It consists of a
number of function modules, as shown in the block diagram above. Each module has a
module number, which is included as the first part of the name/identification of components in
the module.
The modules have the following main functions:
1 MMC module
Control panel and display board.
2 Mains module
Mains switch, mains interference suppressor and power supply board.
15 Power module
This module is a single forward converter, operating at a switching frequency of 65 kHz.
All power semiconductors are built into modules.
20 Processor board module (controller module)
This is the controller board, 20AP1, that monitors and controls the power source. The micro
processor of the board comprises the welding data unit.
WIRING DIAGRAM
0740 800 185
- 6 -
© ESAB AB 2018
WIRING DIAGRAM
The power source is based on a number of function modules. These are described in the
component descriptions on the following pages. Wire numbers and component names in the
wiring diagram show to which module each component belongs.
Circuit boards within each module have names such as 15AP1 - 15AP99.
15 = module association, 1-69
AP = circuit board
1 = individual identification number, 0-99
Components within modules are named in a similar way.
Component description
1 MMC module: control panel and display board, see "1 MMC module", page19.
2 Mains module.
2AP1 Power supply board, see "2AP1 Power supply board", page19.
2L1-2L9 Ferrite ring cores.
2QF1 Mains switch.
2XS1 Flat pin sockets. Important: to obtain a proper electric connection, the complete
cord set must be replaced if the sockets have to be replaced.
15 Power module.
15AP1 Power board, see "15AP1 Power board", page26.
15AP2 Secondary board, see "15AP2 Secondary board", page28.
15C1 Smoothing capacitor, 1000 uF.
15D1 Diode module with rectifier and freewheel diodes.
15EV1 Fan.
15L1 Inductor.
15L2 PFC Inductor (Power Factor Corrector)
15RS1 Shunt. 60 mV at 100 A.
15ST1 Thermal switch, fitted in the winding of main transformer 15TM1. See "20AP1:5
Temperature monitoring", page32.
15ST2 Thermal switch, fitted on the heat sink. See "20AP1:5 Temperature monitoring",
page32.
15TM1 Main transformer.
20AP1 Controller circuit board. See "20AP1 Control board", page29.
20L1 Ferrite ring core.
WIRING DIAGRAM
0740 800 185
- 7 -
© ESAB AB 2018
CAUTION!
STATIC ELECTRICITY can damage circuit boards and
electronic components.
Observe precautions for handling electrostatic
sensitive devices.
Use proper static-proof bags and boxes.
WIRING DIAGRAM
0740 800 185
- 8 -
© ESAB AB 2018
Arc 151i A33, valid for serial no. 803-, 828 and 927-xxx-xxxx
WIRING DIAGRAM
0740 800 185
- 9 -
© ESAB AB 2018
WIRING DIAGRAM
0740 800 185
- 10 -
© ESAB AB 2018
Arc 151i A33, valid for serial no. 747 and 840-xxx-xxxx
WIRING DIAGRAM
0740 800 185
- 11 -
© ESAB AB 2018
WIRING DIAGRAM
0740 800 185
- 12 -
© ESAB AB 2018
Arc 201i A33, valid for serial no. 803-, 828 and 927-xxx-xxxx
WIRING DIAGRAM
0740 800 185
- 13 -
© ESAB AB 2018
WIRING DIAGRAM
0740 800 185
- 14 -
© ESAB AB 2018
Arc 201i A33, valid for serial no. 747 and 840-xxx-xxxx
WIRING DIAGRAM
0740 800 185
- 15 -
© ESAB AB 2018
TECHNICAL DATA
0740 800 185
- 16 -
© ESAB AB 2018
TECHNICAL DATA
Valid for serial no. 803-, 828-, 927-xxx-xxxx
Arc 151i Arc 201i
Mains voltage 230 V, 1 ~ 50/60 Hz 230 V, 1 ~ 50/60 Hz
Primary current
I
max
TIG 13.8 A 24.1 A
I
max
MMA 21.3 A 24.9 A
Mains supply Z
max
0.35 ohm Z
max
0.30 ohm
No-load power 30 W 30 W
Voltage/current range, MMA
A31 8 A /20 V - 150 A /26 V -
A33 4 A /20 V - 150 A /26 V 4 A /20 V - 170 A /26.8 V
Voltage/current range TIG 3 - 150 A 3 - 220 A
Permissible load at MMA
25% duty cycle 150 A / 26.0 V 170 A / 26.8 V
60% duty cycle 100 A / 24.0 V 130 A / 25.2 V
100% duty cycle 90 A / 23.6 V 110 A / 24.4 V
Permissible load at TIG
20% duty cycle - 220 A / 18.8 V
25% duty cycle 150 A / 16.0 V -
60% duty cycle 120 A / 14.8 V 150 A / 16.0 V
100% duty cycle 110 A / 14.4 V 110 A / 15.6 V
Power factor at maximum
current
0.99 0.99
Efficiency at maximum current 80% 81%
Open-circuit voltage
A31 without VRD function
1)
58 - 72 V -
A33 VRD function deactivated
2)
55 - 60 V 55 - 60 V
VRD function activated
2)
< 35 V < 35 V
Operating temperature -10 °C - +40 °C -10 °C - +40 °C
Transportation temperature -20 °C - +55 °C -20 °C - +55 °C
Constant A-weighted sound
pressure
< 70 dB < 70 dB
Dimensions, l x b x h 418 x 188 x 208 mm 418 x 188 x 208 mm
Weight
with A31 7.9 kg -
with A33 8.1 kg 8.3 kg
Enclosure class IP 23 IP 23
Application class
TECHNICAL DATA
0740 800 185
- 17 -
© ESAB AB 2018
Valid for serial no. 747-, 840-xxx-xxxx
Arc 151i Arc 201i
Mains voltage 230 V, 1 ~ 50/60 Hz 230 V, 1 ~ 50/60 Hz
Primary current:
I
max
TIG 13.8 A 24.1 A
I
max
MMA 21.3 A 24.9 A
No-load power 30 W 32 W
Voltage/current range, MMA:
A31 8 A / 20 V - 150 A / 26 V -
A33 4 A / 20 V - 150 A / 26 V 4 A / 20 V - 170 A / 26.8 V
Voltage/current range TIG 3A / 10V - 150 A / 16V 3A / 10V - 220A / 18V
Permissible load at MMA:
25% duty cycle 150 A / 26.0 V 170 A / 26.8 V
60% duty cycle 100 A / 24.0 V 130 A / 25.2 V
100% duty cycle 90 A / 23.6 V 110 A / 24.4 V
Permissible load at TIG:
20% duty cycle - 220 A / 18.8 V
25% duty cycle 150 A / 16.0 V -
60% duty cycle 120 A / 14.8 V 150 A / 16.0 V
100% duty cycle 110 A / 14.4 V 110 A / 14.4 V
Power factor at maximum current 0.99 0.99
Efficiency at maximum current 80% 81%
Open-circuit voltage:
A31 without VRD function
1)
58 - 72 V -
A33 VRD function deactivated
2)
56 V 56 V
VRD function activated
2)
23 V 22 V
Operating temperature -10 °C - +40 °C -10 °C - +40 °C
Transportation temperature -20 °C - +55 °C -20 °C - +55 °C
Constant A-weighted sound
pressure
< 70 dB < 70 dB
Dimensions (l × b × h) 418 × 188 × 208 mm 418 × 188 × 208 mm
Weight:
with A31 7.9 kg -
with A33 8.1 kg 8.3 kg
Enclosure class IP 23 IP 23
Application class
1) Valid for power sources without VRD specification on the rating plate.
2) Valid for power sources with VRD specification on the rating plate. The VRD function is
explained in the instruction manual for the control panel.
Mains supply, Z
max
TECHNICAL DATA
0740 800 185
- 18 -
© ESAB AB 2018
Maximum permissible line impedance of the network in accordance with IEC 61000-3-11.
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40°C/104°F, or below.
Enclosure class
The IP code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked IP23 is intended for indoor and outdoor use.
Application class
The symbol indicates that the power source is designed for use in areas with increased
electrical hazard.
DESCRIPTION OF OPERATION
0740 800 185
- 19 -
© ESAB AB 2018
DESCRIPTION OF OPERATION
This description of operation describes the function of circuit boards and other components in
the equipment. It is divided into sections, numbered to correspond to the circuit board
numbers and divisions into function blocks.
1 MMC module
The MMC module consists of an operator's control panel and a display board.
The control panel is used for setting and displaying welding data. The welding data are
stored by the control board of the power source.
The control panel is described in separate instruction and service manuals.
A33 intended for MMA- and DC TIG welding without pulsing.
Pushbuttons are used for parameter selection and a knob for parameter settings.
2AP1 Power supply board
The power supply board filters the mains voltage and generates internal supply voltages for
the equipment.
There are several different versions of the power supply board. The difference between the
versions can be seen in section "2AP1 Component positions", page23.
DESCRIPTION OF OPERATION
0740 800 185
- 20 -
© ESAB AB 2018
2AP1:1 Interference suppressor circuit
WARNING!
Dangerous voltage - mains voltage
The mains voltage is filtered by the power supply board. Power board 15AP1 rectifies the
mains voltage.
Serial no. 803-, 828-, 927-xxx-xxxx
Serial no. 747-, 840-xxx-xxxx
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

ESAB Arc 201i A33 Caddy User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI