ICP DAS USA MQ-7252M User manual

Type
User manual

This manual is also suitable for

IndustrialComputer Products
Data Acquisition Systems
WrittenbyLiamLin
EditedbySunnyChiu
MQ7200M Series
User Manual
Ve r sio n 1.0.0, Aug. 2016
MQ7200MUserManual,version1.0.0I
Warranty
AllproductsmanufacturedbyICPDASareunderwarrantyregardingdefectivematerials
foraperiodofoneyear,beginningfromthedateofdeliverytotheoriginalpurchaser.
Warning
ICPDASassumesnoliabilityforanydamageresultingfromtheuseofthisproduct.ICP
DASreservestherighttochangethismanualatanytimewithoutnotice.The
informationfurnishedbyICPDASisbelievedtobeaccurateandreliable.However,no
responsibilityisassumedbyICPDASforitsuse,norforanyinfringementsofpatentsor
otherrightsofthirdpartiesresultingfromitsuse.
Copyright
Copyright©2016byICPDASCO.,LTD.Allrightsarereserved.
Trademarks
Namesareusedforidentificationpurposeonlyandmayberegisteredtrademarksof
theirrespectivecompanies.
ContactUS
Ifyouhaveanyproblems,pleasefeelfreetocontactus.
Youcancountonusforaquickresponse.
Email:[email protected]
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0II
TableofContents
1. Introduction ............................................................................................1
1.1. Features ...........................................................................................................2
1.2. Overview..........................................................................................................5
1.3. Dimensions(Unit:mm)....................................................................................6
2. HardwareInformation.............................................................................7
2.1. MQ7244M ......................................................................................................7
2.2. MQ7251M ......................................................................................................9
2.3. MQ7252M ....................................................................................................10
2.4. MQ7 253M ....................................................................................................12
2.5. MQ7 255M ....................................................................................................13
3. GettingStarted......................................................................................15
3.1. CablingPowerandNetwork ..........................................................................16
3.2. InstallingtheMiniOS7Utility .........................................................................17
3.3. ConfiguringNetworkSettings ........................................................................17
3.4. EnablingtheAdobeFlashPlayerinYourBrowser..........................................21
3.5. LoggingintoWebInterface...........................................................................22
4. Configuration ........................................................................................24
4.1. BasicSettings .................................................................................................25
4.2. I/OSettings ....................................................................................................28
4.3. MQTT .............................................................................................................30
5. WebHMI ...............................................................................................38
6. MiniOS7UtilityTools .............................................................................41
6.1. EstablishingaConnection ..............................................................................41
6.2. ExchangingtheProtocol(TCP/IPtoUDP).......................................................44
6.3. UpdatingtheMQ7200MOS .........................................................................46
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0III
6.4. UpdatingtheMQ7200MFirmware ..............................................................49
7. FAQ .......................................................................................................52
7.1. HowtopublishI/OstatusmessagetoanMQTTbroker?............................... 52
7.2. HowtosubscribeI/OstatusonaMQ7200M?..............................................54
7.3. HowtocontrolDOchannelonaMQ7200M? ...............................................56
7.4. HowtorestoreMQ7200Mtodefaultsettings? ............................................58
Troubleshooting............................................................................................59
RevisionHistory ............................................................................................60
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:1
1. Introduction
TheMQ7200MseriesisawebbasedEthernetI/Omoduleequippedwithabuiltinwebserverallows
the user to configure module and control/monitor the status of digital I/O by simply using a regular
webbrowser.
SupportforMQTTprotocolmakesiteasytoconnectsensorstoInternetofThings(IoT)systemviathe
MQ7200Mseriesmodule.Userscansimplyandeffectivelycontrol/monitorremotesensorswithMQTT
clienttoolsonthePC/NBormobiledevices.
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:2
1.1. Features
The MQ7200M module off ers the most comprehensive configuration focused on meeting specific
application requirements. The following details the features designed to simplify installation,
configurationandapplication.
SupportforMQTTProtocol
MQTT stands for Message Queuing Telemetry Transport. It is a machinetomachine
(M2M)/"Internet of Things" connectivity protocol with extremely lightweight publish/subscribe
messagingtransport.Itisusefulformobileapplicationsbecauseofitssmallsize,lowpowerusage,
minimizeddatapack ets,andefficientdistributionofinformationtooneormanyreceivers.
BuiltinI/O
VariousI/OcomponentsaremixedwithmultiplechannelsinasingleI/Omodule,whichprovides
themostcosteffectiveI/OusageandenhancesperformanceoftheI/Ooperations.
DaisyChainEthernetCabling
TheMQ7200MSerieshasabuiltintwoportEthernetswitchtoimplementdaisychaintopology.
Thecablingismucheasierandtotalcostsofcableandswitcharesignificantlyreduced.
LANBypass
LANBypassfeatureguaranteestheEthernet
communication.Itwillautomaticallyactive
tocontinuethenetworktrafficifanyoneof
theMQ7200Mloosesitspower.
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:3
DualWatchdog
The Dual Watchdog is consists of a Module Watchdog and a Communication Watchdog. The
actionsofdigitaloutputarealsoassociatedtotheDualWatchdog.
ModuleWatchdogisabuiltinhardwarecircuittomonitortheoperationofthemoduleandwill
reset the CPU if a failure occurs in the hardware or the software. Then the Poweron Value of
digitaloutputwillbeloaded.
Communication Watchdog is a software function to monitor the communication between the
MQTTbrokerandtheMQ7200M.WhentheMQ7200MisdisconnectedfromtheMQTTbroker
for a while, the watchdog forces the digital output to predefined Safe Value to prevent
unpredictabledamageoftheconnecteddevices.
PoweronValueandSafeValue
PoweronvalueandSafeValuearedesignedtoimprovesystemsafety:
PoweronValue:ThePoweronValueisloadedintothedigitaloutputwhenthemoduleis
poweredonorresetbyModuleWatchdog.
SafeValue:WhentheCommunicationWatchdogisenabledandaCommunicationWatchdog
timeoutoccurs,the“safevalueisloadedintothedigitaloutput.

HighlyReliableUnderHarshEnvironment
WideOperatingTemperatureRange:‐25~+75°C
StorageTemperature:‐30~+80°C
Humidity10~90%RH(Noncondensing)
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:4
ResetButton
Theresetbuttonisusedtorestoreallsettingstofactorydefaults.
ItisveryusefulespeciallywhenyouforgettheIPaddresstoaccesstheMQ7200M
module.
ResetButton
Pressingandholdingtheresetbuttonforatlease3secondswillrestorethemoduletoitsfactory
defaults.Formoreinformation,seesection“7.4.HowtorestoreMQ7200Mtodefaultsettings?”.
LEDindicat orsforDIOstatus
TheLEDindicatorsareusedtoindicate
thestatusofdigitalI/OontheMQ7200M.
Twopairofpowerinputpins
TheMQ7200Mhas4pinsastwopairsfor
powerinputtoeasethewiring.
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:5
1.2. Overview
Connector2
I/O Indictors
LEDIndictors
Connector1
E2Port
E1Port
ResetButton
Model Label Status Description
RUN Flashing Theunitisturnedonandready.
On AlinkhasbeenestablishedontheE1port.
Off NolinkisestablishedontheE1port.
E1
Flashing DataistransferringviatheE1port.
On AlinkhasbeenestablishedontheE2port.
Off NolinkisestablishedontheE2port.
E2
Flashing DataistransferringviatheE2port.
LED
Indicators
I/O
Indictors
TheexactdesignandfunctionalitydependsontheI/Otypesonthemodule.
Connector1
Connector2
Theexactdesignandfunctionalitydependsonthemodulespecifications.
ResetButton Pressingandholdingtheresetbuttonforatleast3secondscanresetthemodule.
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:6
1.3. Dimensions(Unit:mm)
LeftSideView
TopView
Front View
BottomView
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:7
2. HardwareInformation
2.1. MQ7244M
I/OSpecifications
DigitalInput
Channels 8
Contact WetCont act
Sink/Source(NPN/PNP) Sink/Source
OnVoltageLevel +10V
DC
~+50V
DC
OffVoltageLevel +4V
DC
max.
InputImpedance 10KΩ
OvervoltageProtection 70V
DC
DigitalOutput
Channels 8
Type IsolatedOpenCollector
Sink/Source(NPN/PNP) Sink
Max.LoadCurrent
650mA/Channelat25°C
DirectDrivePowerRelayModule
LoadVoltage +3.5V
DC
~+50V
DC
OvervoltageProtection 60V
DC
OverloadProtection 1.4A
ShortcircuitProtection Yes
PoweronValue Yes,Configurable
SafeValue Yes,Configurable
PinAssignments
WireConnections
DigitalInput Readbackas1 Readbackas0
+10~+50V
DC
Openor<4V
DC
Sink
+10~+50V
DC
Openor<4V
DC
Source
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:8
DigitalOutput
ONState
Readbackas1
OFFState
Readbackas0
DriveRelay
ResistanceLoad
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:9
2.2. MQ7251M
I/OSpecifications
DigitalInput
Channels 16
Contact WetCont act
Sink/Source(NPN/PNP) Sink/Source
OnVoltageLevel +10V
DC
~+50V
DC
OffVoltageLevel +4V
DC
max.
InputImpedance 10KΩ
OvervoltageProtection 70V
D
PinAssignments
WireConnections
DigitalInput Readbackas1 Readbackas0
+10~+50V
DC
Openor<4V
DC
Sink
+10~+50V
DC
Openor<4V
DC
Source
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:10
2.3. MQ7252M
I/OSpecifications
DigitalInput
Channels 8
Contact WetCont act
Sink/Source(NPN/PNP) Sink/Source
OnVoltageLevel +10V
DC
~+50V
DC
OffVoltageLevel +4V
DC
max.
InputImpedance 10KΩ
OvervoltageProtection 70V
DC
DigitalOutput
Channels 8
Type IsolatedOpenCollector
Sink/Source(NPN/PNP) Source
Max.LoadCurrent 650mA/Channelat25°C
LoadVoltage +10V
DC
~+40V
DC
OvervoltageProtection 47V
DC
OverloadProtection‐
ShortcircuitProtection Yes
PoweronValue Yes,Configurable
SafeValue Yes,Configurable
PinAssignments
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:11
WireConnections
DigitalInput Readbackas1 Readbackas0
+10~+50V
DC
Openor<4V
DC
Sink
+10~+50V
DC
Openor<4V
DC
Source
DigitalOutput
ONState
Readbackas1
OFFState
Readbackas0
Source
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:12
2.4. MQ7253M
I/OSpecifications
DigitalInput
Channels 16
Contact DryContact
Sink/Source(NPN/PNP) Source
OnVoltageLevel ClosetoGND
OffVoltageLevel Open
OvervoltageProtection‐
EffectiveDistance 500MMax.
PinAssignments
WireConnections
DigitalInput
ONState
Readbackas1
OFFState
Readbackas0
DryContact
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:13
2.5. MQ7255M
I/OSpecifications
PinAssignments
WireConnections
DigitalInput Readbackas1 Readbackas0
+10~+50V
DC
Openor<4V
DC
WetContact(Sink)
+10~+50V
DC
Openor<4V
DC
WetContact
(Source)
DigitalInput
Channels 8
Contact DryandWetContact
Sink/Source(NPN/PNP)
Dry:Source
Wet:Sink/Source
OnVoltageLevel +10V
DC
~+50V
DC
WetCont act
OffVoltageLevel +4V
DC
max.
OnVoltageLevel ClosetoGND
DryContact
OffVoltageLevel Open
InputImpedance 10KΩ
OvervoltageProtection +70V
DC
DigitalOutput
Channels 8
Type IsolatedOpenCollector
Sink/Source(NPN/PNP) Source
Max.LoadCurrent 650mA/channelat25°C
LoadVoltage +10V
DC
~+40V
DC
OvervoltageProtection 47V
DC
OverloadProtection‐
ShortcircuitProtection Yes
PoweronValue Yes,Configurable
SafeValue Yes,Configurable
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:14
DigitalInput
ONState
Readbackas1
OFFState
Readbackas0
DryContact
DigitalOutput
ONState
Readbackas1
OFFState
Readbackas0
Source
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:15
3. GettingStarted
IfyouarenewtoMQ7200Mmodule,startwiththischapterasitincludesaguidedtourthatprovidesa
basicoverviewofhowtoinstall,configureandusethemodule.
WhatsintheBOX?
Beforestartinganytask,pleasecheckthepackagecontents.Ifanyofthefollowingitemsareeither
missingordamaged,contactyourdealerordistributor.
MQ7200MModuleQuickStartGuide
TechnicalSupport
z MQ7200MUserManual

http://ftp.icpdas.com/pub/cd/mq7200m/document
z MQ7200MWebsite
http://www.icpdas.com/root/product/solutions/remote_io/mqtt_io/
mq7200m_introduction.html
z ICPDASWebsite

http://www.icpdas.com/
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
MQ7200MUserManual,version1.0.0Page:16
3.1. CablingPowerandNetwork
Step1
ConnectthecomputertotheEthernetPortviatheHuborSwitch.
Step2
Connectthepositiveofthepowersupplytotheterminalmarked“(R)+Vs”.
Connectthenegativeofthepowersupplytotheterminalmarked“(B)GND”.
Host PC
Power Supply
+12 to +48 V
DC
Hub/Switch
Copyright©2016ICPDASCO.,LTD.AllRightsReserved.Email:[email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

ICP DAS USA MQ-7252M User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI