Textron HB10 / 49830 Dynapress Hydraulic Booster User manual

Type
User manual

This manual is also suitable for

OPERATION MANUAL
HB10 Dynapress
®
Hydraulic Booster
99933381 REV 4 © 2012 Greenlee Textron Inc. 12/12
Read and understand all of the instructions and
safety information in this manual before operating
or servicing this tool.
Register this product at www.greenlee.com
Español ............... 13
Français .............. 25
Deutsch .............. 37
Italiano ................ 49
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
2
Safety
Safety is essential in the use and maintenance of
Greenlee Utility tools and equipment. This instruction
manual and any markings on the tool provide informa-
tion for avoiding hazards and unsafe practices related to
the use of this tool. Observe all of the safety information
provided.
Purpose of this Manual
This instruction manual is intended to familiarize
all personnel with the safe operation and maintenance
procedures for the Greenlee Utility HB10 Dynapress
®
Hydraulic Booster.
Keep this manual available to all personnel.
Replacement manuals are available upon request
at no charge at www.greenlee.com.
Other Publications
Tool Owners/Users
Specications and Parts Manual:
Publication 99933390
SAE Standard J1273 (Hose and Hose Assemblies):
Publication 99930323
All specications are nominal and may change as design
improvements occur. Greenlee Textron Inc. shall not be liable for
damages resulting from misapplication or misuse of its products.
Dynapress
®
is a registered trademark of Greenlee Textron Inc.
KEEP THIS MANUAL
Table of Contents
Description .................................................................... 2
Purpose ......................................................................... 2
Important Safety Information ..................................... 3-5
Identication .................................................................. 6
Hoses and Fittings ........................................................ 7
Hose Connections ......................................................... 7
Typical Setup ................................................................. 7
Operation ....................................................................... 8
Maintenance .................................................................. 9
Troubleshooting ........................................................... 10
Accessories ................................................................. 11
Description
The Greenlee Utility HB10 Dynapress
®
Hydraulic
Booster is a piston-type accessory intended to allow the
use of a high pressure/low ow tool with a low pressure/
high ow hydraulic power source. Compatible with
either Open-Center or Closed-Center hydraulic systems,
the unit takes a hydraulic input of 69 to 152 bar (1000to
2200 psi) and produces a stable output of 700 bar
(10,000 psi).
The HB10 can be installed in existing two-hose type
hydraulic systems, and does not require a third hydrau-
lic line or separate reservoir. The compact and light-
weight design allows the unit to be easily carried and
used on the ground or in an aerial lift basket. Actuating
the high-pressure circuit of the Dynapress requires a
remote control valve, purchased separately. The instruc-
tions and illustrations in this manual reect using the
HB10 with either of the following Greenlee Utility remote
control valves:
PVA0021A (Single-Acting Control Valve)
PVA0022A (Double-Acting Control Valve)
The terms “unit” and “booster,” when used in this
manual, refer to the HB10. The term “tool” refers to the
device (cable cutter, crimping tool, etc) that is powered
by the HB10.
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
3
IMPORTANT SAFETY INFORMATION
SAFETY
ALERT
SYMBOL
This symbol is used to call your attention to hazards
or unsafe practices which could result in an injury or
property damage. The signal word, dened below,
indicates the severity of the hazard. The message
after the signal word provides information for pre-
venting or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result
in severe injury or death.
Hazards which, if not avoided, COULD result in
severe injury or death.
Hazards or unsafe practices which, if not avoided,
MAY result in injury or property damage.
Read and understand all of the
instructions and safety information
in this manual before operating or
servicing this tool.
Failure to observe this warning will
result in severe injury or death.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection can
result in serious eye injury from
ying debris or hydraulic oil.
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
4
Electric shock hazard:
This booster is not insulated. When
using this unit near energized elec-
trical lines:
• Use only certied non-conductive
hoses and proper personal protec-
tive equipment.
• Select and maintain the hydraulic
uid to meet the minimum dielec-
tric standards required by your
safety department.
Failure to observe this warning can
result in severe injury or death.
Skin injection hazard:
Oil under pressure easily punctures
skin causing serious injury, gan-
grene or death. If you are injured by
escaping oil, seek medical attention
immediately.
• Do not use ngers or hands to
check for leaks.
• Do not hold hose or couplers
while
the hydraulic system is
pressurized.
• Depressurize the hydraulic system
before servicing.
Booster may be hot during and after
operation. Allow unit to cool before
handling, or handle with heat-resis-
tant gloves.
Hot surfaces can cause severe
burns.
Do not exceed the maximum hydraulic ow, pressure
relief or back pressure listed in the Specications
and Parts manual.
Failure to observe this warning can result in severe
injury or death.
Do not disconnect booster, hoses, or ttings while
the power source is running or if the hydraulic uid
is hot. Hot hydraulic uid can cause serious burns.
Do not reverse hydraulic ow. Operation with
hydraulic ow reversed can cause a malfunction.
Connect the supply (pressure) hose and return (tank)
hose to the proper ports.
Failure to observe this warning can result in severe
injury or death.
• Inspect the hydraulic hoses and couplings every
operating day. Repair or replace if leakage, crack-
ing, wear, or damage is evident. Damaged hoses
or couplings can fail, resulting in injury or property
damage.
• Make sure all bystanders are clear of the work
area when handling, starting and operating tool.
Nearby personnel can be injured by ying or
falling debris or by ying parts in the event of a
malfunction.
Failure to observe these warnings can result in
severe injury or death.
IMPORTANT SAFETY INFORMATION
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
5
IMPORTANT SAFETY INFORMATION
Inspect unit before operating. Replace any worn,
damaged or missing components with Greenlee
Utility replacement parts. A damaged or improperly
assembled component can fail and strike nearby
personnel.
Failure to observe this precaution can result in
severe injury or death.
Use this tool for manufacturer’s intended purpose
only. Use other than that which is described in this
manual can result in injury or property damage.
Failure to observe this precaution can result in injury
or property damage.
Hydraulic oil can cause skin irritation.
• Handle the booster and hoses with care to prevent
skin contact with hydraulic oil.
• In case of accidental skin contact with hydraulic
oil, wash the affected area immediately to remove
the oil.
Failure to observe these precautions can result in
injury.
Emergency stop procedure:
1. Move the remote control valve’s lever to the
neutral position.
2. Move the ow lever on the hydraulic power
source to the OFF position.
Procedure for disconnecting hydraulic hoses, ttings
or components:
1. Move the ow lever on the hydraulic power
source to the OFF position.
2. Stop the power source.
3. Follow the sequence under Disconnecting
Hoses to prevent pressure buildup. In case
some pressure has built up, loosen hoses, t-
tings or components slowly.
Note: Keep decals clean and legible. Replace
decals when necessary—see the decals listed in the
Specifications and Parts manual.
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
6
Identification
1. Handle
2. Input Side Pressure Port
3. Input Side Tank Port
4. Unloading Valve
5. Output Side Tank Port
6. Output Side Pressure Port
Input Side
69 to 152 bar (1000 to 2200 psi)
Output Side
700 bar (10,000 psi)
HB10 Dynapress
®
Hydraulic Booster
1
2
3
4
5
6
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
7
Hoses and Fittings
Installation and Maintenance
See publication 99930323,
SAE J1273 (Hose and Hose Assemblies).
Replacement
See a Greenlee Utility catalog or Greenlee Utility
publication 99910322, Low Pressure Quick Couplers,
Adapters and Hoses.
Hose Connections
Connecting Hoses
Use this procedure to prevent pressure buildup in the
hydraulic circuit:
1. Move the ow lever on the hydraulic power source
to the OFF position.
2. Stop the hydraulic power source.
3. Connect high-pressure hoses to the high-pressure
ports as follows:
return (tank) hose: remote control valve to booster
supply (pressure) hose: remote control valve to
booster
*return (tank): remote control valve to tool
supply (pressure) hose: remote control valve to
tool
* This step applies to double-acting tool and control
valve only.
4. Connect the low-pressure hoses to the low-pressure
ports as follows:
return (tank) hose: booster to power source
supply (pressure) hose: power source to booster
Disconnecting Hoses
Use this procedure to prevent pressure buildup in the
hydraulic circuit:
1. Move the ow lever on the hydraulic power source
to the OFF position.
2. Stop the hydraulic power source.
3. Disconnect the hoses in reverse order of the con-
nection sequence.
4. Install dust caps to prevent contamination.
Typical Setup
Power Source
HB10 PVA0021A Single-Acting
Tool
Optional:
Tool connected to control valve
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
8
Operation
Electric shock hazard:
This booster is not insulated. When
using this unit near energized elec-
trical lines:
• Use only certied non-conductive
hoses and proper personal protec-
tive equipment.
• Select and maintain the hydraulic
uid to meet the minimum dielec-
tric standards required by your
safety department.
Failure to observe this warning can
result in severe injury or death.
Skin injection hazard:
Oil under pressure easily punctures
skin causing serious injury, gan-
grene or death. If you are injured by
escaping oil, seek medical attention
immediately.
• Do not use ngers or hands to
check for leaks.
• Do not hold hose or couplers
while
the hydraulic system is
pressurized.
• Depressurize the hydraulic system
before servicing.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection can
result in serious eye injury from
ying debris or hydraulic oil.
Read and understand all of the instructions and
safety information supplied with the tool.
Failure to observe this warning can result in severe
injury or death.
1. Start the hydraulic power source.
Note: Allow the power source to run for a few
minutes to warm the hydraulic fluid.
2. To actuate the tool, press down and hold the lever in
the ADVANCE position.
• When the pressure exceeds approximately
207bar (3000 psi), the operator may release the
control lever. The lever will remain in the
ADVANCE position.
• When the pressure reaches the relief setting of
the unloading valve – 700 bar (10,000 psi) – the
high pressure oil will dump back to tank and the
system pressure will drop to nearly zero. The
operator can then release the remote control lever
back to the neutral position.
3. To return or retract the ram, press down and hold
the lever in the RETRACT position.
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
9
Maintenance
Skin injection hazard:
Oil under pressure easily punctures
skin causing serious injury, gan-
grene or death. If you are injured by
escaping oil, seek medical attention
immediately.
• Do not use ngers or hands to
check for leaks.
• Do not hold hose or couplers
while
the hydraulic system is
pressurized.
• Depressurize the hydraulic system
before servicing.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection can
result in serious eye injury from
ying debris or hydraulic oil.
Notes:
(1) Keep all decals clean and legible. Replace decals
when necessary. See the Specifi–cations and Parts
manual for decal part numbers.
(2) When disposing of any components (hydraulic
hoses, hydraulic fluid, worn parts, etc.), do so in
accordance with federal, state and local laws or
ordinances.
Daily
1. Wipe all booster surfaces clean.
2. Inspect the hydraulic hoses and ttings for signs
of leaks, cracks, wear or damage. Replace if
necessary.
3. Install dust caps when the unit is disconnected.
Monthly
Perform a thorough inspection of the hydraulic hoses
and ttings as described in publication 99930323,
SAE J1273 (Hose and Hose Assemblies).
Periodically
Use a non-lled pressure gauge, like the Greenlee Utility
137779, to verify that the unloading valve relief pres-
sure is 700 bar (10,000 psi). Send the booster to an
authorized Greenlee Utility service center if adjustment
is necessary.
Annually
If required by your organization, have the tool inspected
by a Greenlee Utility Authorized Service Center.
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
10
Problem Probable Cause Probable Remedy
Booster does not operate. Improper power source. Verify that the power source meets the
specications. See the Specications
and Parts manual.
Hydraulic uid level low. Check the uid level. Check system for
leaks.
Incorrect hydraulic uid viscosity. Use hydraulic uid with the correct
viscosity. See the Specications and
Parts manual.
Booster operates slowly or
erratically.
Hydraulic uid cold. Allow uid to warm to the operating
temperature. Actuate the tool intermit-
tently to reduce the warming time.
Power source not adjusted correctly. Refer to the power source operator’s
manual. Set the ow and pressure to
correspond with the booster.
Hydraulic uid level low. Check the uid level. Check system for
leaks.
Air in the hydraulic system. See power source manufacturer’s
instructions for removing air from the
system.
Incorrect hydraulic uid viscosity. Use hydraulic uid with the correct
viscosity. See the Specications and
Parts manual.
Booster feels hot. Hydraulic uid level low. Check the uid level. Check for leaks.
Incorrect hydraulic uid viscosity. Use hydraulic uid with the correct
viscosity. See the Specications and
Parts manual.
Hydraulic uid dirty. See the power source owner’s manual
for procedure to replace hydraulic oil
and lter.
Troubleshooting
Before troubleshooting, determine whether the problem
is in the booster, the hoses, or the power source.
Substitute a booster, hoses, or power source known to
be in good working order to eliminate the item that is
not operating.
If the problem is in the booster, see the troubleshoot-
ing table in this manual. If the problem is in the power
source, see the troubleshooting section of the power
source instruction manual.
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
11
Accessories
5 6
2 3 4 8
7
1
Complete Hose Assemblies Rated at 700 bar (10,000 psi)
41107 50411074 6 ft (includes 1–7) ...................................1
41108 50411083 10 ft (includes 1–7) .................................1
Remote Control Valves
42948 50429481 Single-acting ..........................................1
42949 50429491 Double-acting .........................................1
Hoses Rated at 700 bar (10,000 psi)
1 41795 50417951 6 ft, 1/4 MNPT x 1/4 MNPT ....................1
1 41796 50417961 10 ft, 1/4 MNPT x 1/4 MNPT ..................1
Couplers and Fittings
2 41401 50414014 Coupler, 1/4 FNPT x 1/4 FNPT ...............2
3 41344 50413442 Adapter, 1/4 MNPT x 1/4 MNPT .............1
4 54169 51541690 Male coupler, 1/4 FNPT ..........................1
5 42096 50420961 Female coupler, 1/4 MPNT .....................1
41842 50418421 O-ring, .625 x .812 x .093–90D ..............1
6 41834 50418341 Dust cap .................................................1
7 41587 50415870 Ty-Rap ....................................................3
8 41830 50418301 Dust cap .................................................1
UPC No.
Key 78-3310- Part No. Description Qty
UPC No.
Key 78-3310- Part No. Description Qty
HB10 Dynapress
®
Hydraulic Booster
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
12
Reforzador Hidráulico Dynapress
®
HB10
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
24
Surpresseur hydraulique HB10 de Dynapress
®
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
35
Accessoires
5 6
2 3 4 8
7
1
Assemblages complets de tuyau à 700 bars (10000 psi)
41107 50411074 6 pieds (comprend 1–7) ..........................1
41108 50411083 10 pieds (comprend 1–7) ........................1
Soupapes de commande à distance
42948 50429481 Action simple ..........................................1
42949 50429491 Double action .........................................1
Tuyaux à 700 bars (10000 psi)
1 41795 50417951 6 pieds, 1/4 po M NPT
x 1/4 po M NPT ......................................1
1 41796 50417961 10 pieds, 1/4 po M NPT
x 1/4 po M NPT ......................................1
Raccords
2 41401 50414014 Raccord, 1/4 po F NPT
x 1/4 po F NPT .......................................2
3 41344 50413442 Adaptateur, 1/4 po M NPT
x 1/4 po M NPT ......................................1
4 54169 51541690 Raccord, Mâle, 1/4 po F NPT .................1
5 42096 50420961 Raccord, Femelle, 1/4 po M NPT ...........1
41842 50418421 Joint torique,
0,625 x 0,812 x 0,093 po–90D ...............1
6 41834 50418341 Capuchon protecteur .............................1
7 41587 50415870 Ty-Rap ....................................................3
8 41830 50418301 Capuchon protecteur .............................1
N
o
CUP
Leg. 78-3310- N
o
Ref Description Qté
N
o
CUP
Leg. 78-3310- N
o
Ref Description Qté
Voir le manuel d’instructions du fabricant de la source d’alimentation pour évacuer l’air
du système.
Surpresseur hydraulique HB10 de Dynapress
®
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
36
HB10 Dynapress
®
Hydraulikverstärker
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
48
USA 800-435-0786 Fax: 800-451-2632
815-397-7070 Fax: 815-397-1865
Canada 800-435-0786 Fax: 800-524-2853
International +1-815-397-7070 Fax: +1-815-397-9247
4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070
An ISO 9001 CompanyGreenlee Textron Inc. is a subsidiary of Textron Inc.
www.greenlee.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Textron HB10 / 49830 Dynapress Hydraulic Booster User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI